NOTICE INVITING TENDERS FOR THE PURCHASE OF 1. FLASH CHROMATOGRAPHY 2. ION CHROMATOGRAPH 3. MICROWAVE MUFFLE FURNACE

Similar documents
Precision Temperature Control. Pulse Free Pump. Column Oven. Superb Performance Ion Chromatography. Leak Detector. Modular Flexibility

IC Professional Detector

ProStar 325 UV-Vis Detector

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

HPLC Column Ovens and Temperature Controllers

Equipment specifications (D6)

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Ref. No. RRSS/CH-18/ RIDF Dated : ii) Submission of e-tender: the tender shall be submitted on line within upto 6.00 pm.

Customised HPLC Systems for Highest Performance

Supply & Installation of Fire Protection System at STPI- Nashik. Tender No. STPI/P/PUR/07/14-15 Date Signature of Bidder

ISO-9001:2008 FURNACES CATALOG. Phone: Fax: Web:

Atomic Absorption Spectrophotometer AAS 2320D EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

BENEFITS. QUATERNARY HPLC SYSTEMS Quaternary and Other Gradients. The Complete Range of HPLC. Convenience of Maintenance. Systems Configuration

Technical specifications of FT-IR Spectrometer

Thermo Scientific Dionex Integrion HPIC System

Department of Biochemistry University of Lucknow Lucknow

detectors UltiMate 3000 Variable Wavelength Detectors

Nexera-i Specifications Prominence-i Specifications

Agricultural. drugs of abuse. Food & Beverage. Pesticides SOLID PHASE EXTRACTION. Inject. Wash Elute. Cartridges. Concentrate. Silica.

300 series HPLC autosamplers

RapidTrace + Automated SPE Workstation. Instruments. Accessories Racks Vial Adapters Test Tubes O-Rings Miscellaneous

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Furnaces. High Temperature Box Furnaces Deluxe Muffle Furnaces Economy Muffle Furnaces... 38

Chemtron Science Laboratories Pvt. Ltd.

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems

Specifications Wavelength Range: 190 nm to 800 nm continuous

LABOKLAV. Autoclaves Made in Germany

No.PRS/R39/2015 Date: 17 August 2015

INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE

Atomic Absorption Spectrometer

Perkin Elmer Clarus 500 Gas Chromatograph

SUPREME COURT OF INDIA ADMN. MATERIAL BRANCH NOTICE INVITING TENDER FOR COMPREHENSIVE ANNUAL MAINTENANCE CONTRACT FOR RE-FILLING OF FIRE EXTINGUISHERS

Common Features of DX-600 Modules

HITACHI CHROMASTER. Clarity Control Module. Code/Rev.: M173/70I Date: 6/23/2018

CALIDUS tm the Modular micro Gas Chromatograph

Subject: Tender for Comprehensive Annual Maintenance Contract (AMC) for CCTV System

The Intelligent Choice for Rapid, Accurate Microwave Moisture/Solids Analysis. Innovators in Microwave Technology. Chemicals & Coatings.

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

Driven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirapalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

ATOMIC ABSORPTION SPECTROMETER AAS 3500 EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

Supply and installation of a gas delivery unit for Hydrogen fluoride (HF) and a vertical furnace

BANK OF BARODA BIHAR REGIONAL OFFICE, 4 TH FLOOR, ANAND VIHAR, West Boring Canal Road, Patna TENDER NOTICE

DYE QUALITY CONTROL REFERENCE MATERIAL KIT

15900 HVAC INSTRUMENTATION AND CONTROLS

FIXED GAS ANALYZER (FGA)

Model KBWF 720 Growth chambers with light and humidity

FITOCLIMA 600 & 1200 STABILITY

BANK OF BARODA ZONAL OFFICE, MP & CG ZONE BHOPAL TENDER NOTICE

PTWS 120D USP/EP Tablet Dissolution Testing Instrument

FITOCLIMA 600 & 1200 STABILITY

* To be remitted only through DD/Banker Cheque, in favour of Bank of Baroda, payable at Bhopal.

Auto SPE-06Plus Solid Phase Extraction System. Reeko Instrument USA

FITOCLIMA 600 & 1200 PHARMA

CORRIGENDUM NO: 2 TO REQUEST FOR QUOTATION CRFQ NO E-Tender Ref. No: 9093

Relationship beyond banking

Temperature Sensors & Compression Seal Fittings

Thermo Scientific Rocket Evaporator. Revolutionary solvent evaporation complete laboratory workflow

F-900 Portable Ethylene Analyzer

Process Gas Chromatograph

Spark Holland introduces

MiniWAVE Microwave Digestion Made Easy

6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

Model KBWF 240 Growth chambers with light and humidity

Complete Gas Analysis

Recent Improvements in Process GC Instrumentation

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

MOTHER DAIRY A UNIT OF GUJARAT CO-OPERATIVE MILK MARKETING FEDERATION LIMITED PURCHASE ENQUIRY

Tovatech LLC Phone (973) Rutgers St, Maplewood, NJ 07040

NATIONAL BANKING GROUP WEST-1

Thermo Scientific Dionex UltiMate 3000 Fluorescence Detectors

for Drinking Water Systems

Q Trap LC/MS/MS TurboIonSpray Ion Source Manual. About This Manual... 1 Conventions Introduction... 3 Features... 4

PG 990 Atomic Absorption

940 Professional IC Vario

Infrared Moisture Balance (FD-800)

Accessories for WHA 3000P and WHA 3000V

Soil and Plant Methods List for Automated Ion Analyzers. Flow Injection Analysis

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

laboratory & sterilization technology

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

Summer Works Scheme 2010

Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100

Date of Start and downloading the tender 12 sep 2018

t. +44 (0) f. +44 (0) e. w.

WASTEWATER Online UV%Transmission Analyzer

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

STABILITY ICH. ICH Stability Tests

Silica, Phosphate, Hydrazine Analyzers Series 2140 Specifications

Gas Detection - GD -

Optimizing the Performance of the Agilent 1290 Infinity Evaporative Light Scattering Detector

Omniguard 4: Features

TENDER NOTICE FOR RATE CONTRACT FOR SUPPLY, INSTALLATION AND REFILLING OF FIRE EXTINGUISHERS AT BRANCHES / OFFICES IN NCR AND ADJOINING AREAS

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Chemistry Instrumental Analysis Lecture 29. Chem 4631

CCD and CID solid-state detectors

Transcription:

NOTICE INVITING TENDERS FOR THE PURCHASE OF 1. FLASH CHROMATOGRAPHY 2. ION CHROMATOGRAPH 3. MICROWAVE MUFFLE FURNACE ANNEXURE-I Sealed offers (rates and terms & conditions) alongwith detailed literature and specifications are invited from manufacturers/authorized distributors/dealers etc. for supply of Flash Chromatography, Ion Chromatograph and Microwave Muffle Furnace with following terms and conditions: 1. Tenders should be addressed to, Head of the Department, Department of Chemistry, Baba Saheb Ambdekar Road, New University Campus, University of Jammu, Jammu 180 006. 2. Delivery of goods should be FOR Jammu University Campus. 3. Rate should be valid upto 31 st March, 2012. 4. Sale tax/custom duty/excise/entry tax or any other tax, if any, should be clearly mentioned. 5. Concession to educational institutions, if any, should be clearly mentioned. 6. Products confirming to particular standards (ISO, ISI etc.) should be clearly mentioned. 7. In case any item is your proprietary product or if you are sole manufacturer / distributor of requisite item, a certificate to this effect should be enclosed. 8. In case company/firm is registered with DGS&D/any other Government organization/undertaking and contracts awarded; should be clearly mentioned. 9. It is at discretion of the competent authority to reject one/all tenders/part of tender without assigning any reason, thereof. 10. In case seller fails to complete in full, all deliveries of product in accordance with supply order; the seller shall be responsible for the liquidity damages. Thereafter the buyer, will have right to terminate supply order in the case of such delay beyond period mentioned by seller in the offer and buyer will have total discretion to buy product from the market/other supplier at the lowest rate. Page 1 of 7

11. An undertaking should be submitted by your concern that rates quoted in this offer are lowest/at par with rates quoted to other Govt./Semi-Govt. institution in the country and your concern/firm has not sold your product to any other organization in India at lowest price than the price quoted in this offer. It may kindly be noted that University of Jammu will not bear any cost/expenditure arising out of loss during transportation etc. Cost of equipment should include transportation charges and insurance charges upto FOR destination. 12. Tenders are invited under two bid system The supplier shall submit the tender in two envelopes. The first envelope (Technical Bid) shall contain all the documents mentioned below (a),(b),(c),(d) and sealed. (a) Income-Tax clearance certificate from the Income-Tax Officer concerned, certifying that the tenderer has cleared all the Income-Tax dues. (b) The names of the organizations and laboratories to which similar equipment have been supplied. (c) VAT Registration No. (d) Technical specifications offered by the supplier. The second envelope (Commercial Bid) shall contain the Schedule, in which the supplier shall register the rates of supply. The second envelope shall also, likewise, be sealed. Each page of the tender shall be signed in full and stamped with the seal by the supplier. Both the envelopes then should be put together, and shall be sealed in a third envelope which should be marked as, Quotation for Flash Chromatography, Ion Chromatograph and Microwave Muffle Furnace alongwith enquiry number and date. The Technical Bid shall be opened first in the presence of tenderers who would like to be present during tender opening session. The Technical Documents shall be opened in the office of the Head, Department of Chemistry, University of Jammu, in the Department of Chemistry, University of Jammu at 27 th May, 2011. Financial bids of only technically qualified tenderers shall be opened. If the Technical Bids are not in order or are deficient in some respect, the commercial bids in respect of such tenders shall not be opened and shall be returned back to the tenderer. The date and time of opening the Financial bids shall be announced immediately after opening all the Technical bids. Page 2 of 7

13. The delivery, installation and operational training of the instruments/equipment should be completed within 3 months from placing of the order in case of the imported equipment and within 2 months if the instrument/equipment is made in India. No extension shall be granted to the contractors/suppliers for the period of delivery, under any circumstances. 14. Best and final offer (Rates/Catalogues) alongwith requisite information should reach aforementioned address on or before 23 rd May, 2011, within working hours (09:30 am to 05:00 pm) of University of Jammu. In case of holiday on the last day, next working day will be taken into consideration. 15. Technical specifications of the required instruments/equipments/articles are given herein: PART-A SPECIFICATIONS FOR FLASH CHROMATOGRAPHY Automated Flash Chromatography System consisting of Gradient Pump, Column Holder, UV Detector and Fraction Collector as per following technical/operating specification. A : Gradient Pump Flow Rate Solvent Lines Sample loading B : Interface Columns Real-time method change facility Automated method creation Min- 1.0ml/min ; Max- 200ml/min Independent Four solvent, quatro-binary gradient capability wherein it should be possible to use all the four solvents in binary combination in a single run and should have the ability to add third co-solvent during a binary gradient. Provisions for Liquid loading on cartridge. Bulk media loading on the cartridge. System should have space- saving, touch screen controlled graphic user interface with Chromatogram storage, processing and retrieving facilities Suitable cartridge columns for sample from 100mg to 30g.Cartridge construction material should be USP Class VI compliant. Should be able to use cartridges as segmented cartridges. Should include Normal silica and C18 columns of all sizes. Change solvent composition, flow rate, fraction settings during purification and running condition. Facility to create accurate gradient methods based on entered TLC data. The software must have a gradient optimization feature which converts a linear gradient method to solventsaving step gradient method. Page 3 of 7

Cartridge and sample load List of column cartridges with maximum recommended recommendation features sample load under gradient elution Sample loss prevention Sample loss prevention feature and alarms C : Fraction Collector Broad fractions rack capacity to collect minimum 125 fractions & can be enhanced further if required. Ability to add and remove fractions racks during the run Detection Variable, dual-wavelength detector (200-400nm preferably with accuracy ±1nm). Collection Collect fractions using two user selected wavelengths Should be able to communicate (send and receive signals) with a third party detector (Evaporative light-scattering, RI etc.) and fractionate on the received signal PART-B SPECIFICATIONS FOR ION CHROMATOGRAPH 1. The instrument should be PC controlled & analysis of anions like floride, chloride, nitrate, phosphate, sulphate including arsenic and selenium speciation and cations like lithum, sodium, potassium, calcium, potassium including amines and transition metals like zinc, iron, etc. 2. The instrument should have a High Pressure Gradient Pump with selectable 0.001 to 10 ml /min flow rate with a flow reproducibility of ± 0.1%. 3. The Resolution of flow rate should be 0.001 ml, Pulsation lower than 1% and Pressure Range should be 0 5000 PSI. 4. The instrument should have a conductivity detector for analysis of anions and cations and detector should be microprocessor based with a therostated micro-flow cell conductivity block having an accuracy of 0.001 o C. 5. The temperature range of conductivity block should be 20 50 C and conductivity range should be 0-15000 µs/ cm. 6. The electronic noise should be < 0.1 ns/cm level. 7. The column Housing should be able to identify the columns and set the operating conditions for column operation. 8. The instrument should have a 6- port injector valve with fast response time and controlled through software. 9. IC columns for analyses of anions, cations, transition metals should be individually quoted with respective guard columns. The columns should have electronic chip to Page 4 of 7

store data and history of column use. It should also be possible to record the number of injections and the working hours. 10. Suppresser should have high loading and high back-pressure tolerance with continuous regeneration Optional : 11. System should be able to take electrochemical detector at later stage. 12. Electrochemical detector: The Electrochemical Detector should be stand alone one and it should be possible to interface conductivity and electrochemical detector sequentially for monitoring ions in single run through both the detectors. Standard working electrodes like Glassy Carbon and others should be quoted. 13. Polarization Range should be 0.1nA to 10,000 na. 14. Suitable PC printer, UPS 2KVA, eluent filtration with vacuum pump and other accessories should be quoted. PART-C SPECIFICATIONS FOR MICROWAVE MUFFLE FURNACE A. Overview - The system shall consist of a microwave heating system, programmable temperature controller and integral compressed air driven exhaust system with no moving parts. Initial carbonization step on a Bunsen burner, hot plate or under a heat lamp should not be necessary. Results shall be comparable to standard methods and with complete safety. The system must be capable of accepting one of two Ashing Furnace inserts: 1. 5.0 Liter, 1000 C furnace insert which must be able to dry ash up to 15 samples of 25ml crucibles in a time frame of < 30 minutes with results comparable to standard methods and with complete safety. 2. 1.8 Liter, 1200 C furnace insert which must be able to dry ash up to 8 samples of 25ml crucibles in a time frame of < 30 minutes with results comparable to standard methods and with complete safety. 3. Sample containers with sample of any volume or mass that will physically fit into the furnace chamber may be ashed using a multistage ramping program to obtain proper volume reduction before the ignition point of the sample is reached. Page 5 of 7

B. Microwave Unit 1. The system shall have a power output of 1400 + 50 watts containing an ashing furnace insert that can be heated using microwave energy and operating temperature range of ± 1 C; from 0 C to 1200 C. This is required for rapid heat-up and testing flexibility. 2. System shall be equipped with three independent safety interlocks to prevent microwave leakage in compliance with US DHH Standard for Microwave Equipment (21 Code of Federal Regulations 1030.2.4). 3. System shall have an effective door protection device using a mechanical device to prevent damage to the outer door when the operator does not replace the interior furnace door. This device works even in the event of a power failure. 4. The system shall be equipped with an additional protection device consisting of an IR sensor to prevent damage to the outer door when the operator does not replace the interior furnace door. The IR sensor shall also act as over temperature protection to prevent damage to the system in the event the outside temperature of the insulated ashing furnace chamber exceeds safe limits. 5. System shall have an in-board NIST traceable temperature control system with capability to control the temperature ramp rate and the temperature dwell time for up to eight separate stages. Temperatures may be entered in 1 C increments. 6. System shall have a thermocouple calibration procedure incorporated into the control software to allow precise temperature calibration of the thermocouple to the instrument as required by good laboratory practices (GLP). 7. System shall have an adjustable, compressed air driven, built-in and interlocked safety exhaust system which contains no screens or moving parts and channels volatile material from the ashing furnace chamber that discharges at a rate of up to 3.7 cubic meters/minute (130 cubic feet/minute). 8. System shall have software that detects a thermocouple failure, stops the microwave source and signals the operator with an error message on the LCD display, preventing heat related damage. 9. System shall have two serial port connectors and one parallel port connector for use with user supplied external devices such as LIMS, balances, printers, or computers. This Page 6 of 7

permits expansion to meet future needs. The supplier must make available a complete Workstation as an option including a balance and printer with supporting software. Page 7 of 7