G.I. Procedures. Handbook

Similar documents
ON TRACK Reprocessing In-service / Competency for CF/PCF/GIF Endoscopes (EVIS, EXERA, EXERA II)

OLYMPUS AMERICA, INC. ENDOSCOPE GROUP TWO CORPORATE CENTER DRIVE MELVILLE, NEW YORK TEL (631) March 3, 2003

Attendance Sheet. (List each model reviewed during this session) Print Name Signature Title. Print Name Signature Title.

2015 Myco Industries, Inc Fax:

2. Push the drain connector into the disinfectant removal port until it clicks.

INSTRUCTIONS EVIS EXERA GASTROINTESTINAL VIDEOSCOPE

INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE

TBJ Model SPCS B Scope Pre-Cleaning Sink. Product Specification. Product Description

INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE

SERRES SUCTION BAG SYSTEM MANUAL

Caution: Federal U.S. law restricts this device to sale by or on the order of a physician.

Product Catalogue 2016

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

U S E R G U I D E. Home Respiratory Equipment Cleaning Guide. Health Information

Physician s order will specify the level of underwater seal, typically -10 to 20 centimetres (cm) and will identify if suction is to be applied.

EG-2990i, EG-2790i EG-1690K, EG-2490K EG-2790K, EG-2990K EG-3490K, EG-3890TK EG27-i10, EG29-i10

This policy has been adopted by UNC Health Care for its use in infection control. It is provided to you as information only. Infection Control Manual

BAXTER: FACTOR VII 600 IU (Plasma Derived)

DESCALING INSTRUCTIONS For Professional Machines:

INSTRUCTION MANUAL OF WATER DISPENSER ΜΟDEL: CLWD-19PW

Washroom. PURPOSE: To provide clean washrooms for staff, visitors and patients MATERIALS: 19-1

DRAFT. Module 4. Decontamination & Environmental Cleaning

CPAP Washbasin Manual

Administration of AMBISOME Using the GemStar Pump

Special Precautions Isolation Plan Environmental Services

INSTRUCTION MANUAL V8F145

The Professional Choice

VARIABLE RATE INFUSION PUMP

When you successfully complete the test, you will receive a certificate and a registered key ring. We look forward to hearing from you.

The Professional Choice

PASTEURIZED MILK CONTAINERS, CLOSURES AND PACKAGING IMS #22 (PMC) [Unless otherwise stated all tolerances are ±5%] 1. Laboratory Requirements

IQ/OQ Protocol Installation Qualification/ Operation Qualification

DESCALING INSTRUCTIONS for: CS220, CS200, CS100 Page 3 Cappucinatore CS20 Page 5 Gemini CS223 Page 6 Zenius ZN100 Page 7

LAB SAFETY FOR CUSTODIANS

USER MANUAL SPRAY GUN CLEANER - WATER BASED PAINTS UA400W CAUTION FOR WATER BORNE PAINTS ONLY

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

Home Choice cycler for Peritoneal Dialysis: Set up, Disconnect, & Disposal Updated 2015

Thorametrix TM Chest Drainage Systems

DESCALING INSTRUCTIONS For Professional/Out-of-Home Machines:

OPERATION MANUAL. (Cleaning, Disinfection and Storage) Endoscope ED-530XT

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

Requests for Daily Care and Maintenance

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

Syringe Pump. Syringe Pump. Product Model: ZD-50C6 Syringe Pump. ZD-50C6-H Syringe Pump

ASPIRE Laboratory Aspirator

The Memorial Souad Kafafi Medical Center Skills Competency Checklist

FACSCalibur Startup Procedures

THE COMPACT CENTRIFUGE: OPERATOR 1

User information. Cleaning/descaling and sanitizing

Connectors. Right Angled Y-Connectors, swivelling autoclavable up to 134 C, Material: PSU

Infection Control Manual Residential Care Part 3 Infection Control Standard IC9: Environmental

Caring for your Drain Tube at Home

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

FILLING & CLEANING GUIDE

Torrent irrigation pump Reorder No Operating and Maintenance Manual

Model # VWK-2 INSTRUCTION MANUAL

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

2001 Smith Eastern Corporation

WINDSHIELD REPAIR MANUAL SUPER CINCH

ENDOSCOPE REPROCESSOR OER-Pro Operation Manual

WATER/WASTE SYSTEM - SERVICING

Trouble Shooting and Help Guide TT / TTB 1840

SAMPLE MANUAL - INSTALLATION - FOR REFERENCE ONLY. ChemScan mini Analyzer. Parameter. Method #### Installation, Operation & Maintenance Manual

Standard Operating Manual

INSTRUCTION MANUAL. Endo-Jet 2000 (EJ-2) PAULDRACH medical GmbH Porschestrasse Garbsen GERMANY

M175 Sakamoto Suction Simulator

Maintenance Guide. Contents

PDS 2010 Parylene Coater SOP

ATOMLAB XENON TRAP MONITOR OPERATION AND INSTALLATION MANUAL FN: /12

Syclone Amalgam Separator Installation and operating guide

Laser Class 4 Laser Type Nd-YAG Laser Manufacturer New Wave Research Laser Model SoloII-30 PIV Laser Serial / Id # Serial number 16582

PERFORM Operating Document

BIOVAC 500 SMOKE EVACUATOR

Tube Feeding by Pump UHN. Information for patients and families. Read this book to learn:

STANDARD OPERATING PROCEDURE

ASSESSMENT REPORT ENDOZIME INSTRUSPONGE

Your. for Vivarium Supplies

NEOTeCHA Reactor Sampling Type PV

Effective Date: 0 8 / 1 0 / 1 7. Replaces: 08/11/16. Formulated:1997 SPECIAL (MEDICAL) WASTE MANAGEMENT

CER-1 / CER-2 (MV-1 / MV-2) (CLM-5001X / CLM-5002VX)

CleaningProtocol. Guidelines for Frontline Staff

PROFESSIONAL BREW DEVIL MICRO BREWERY INSTRUCTION MANUAL. Thank you for purchasing this Brew Devil Microbrewery system.

EQ-ROBO Programming : Cliff Check Robot

NBSeries Installation Operation & Maintenance

Flexible Nasopharyngoscope. Operator Manual. Manufactured by Henke-Sass, Wolf Distributed by Anthony Products, Inc.

Rigid Reusable & Single use Sigmoidoscopes, Anoscopes, and Accessories ENGLISH 1. Perform reprocessing immediately after each use.

Printed in U.S.A Rev. A 6/2005 0B

G45 FastTrack. Page 1 of 8

MO n : 12JMC rév A

CONSTANT SUCTION UNIT

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

AUC Cell Washer. User Manual

Across-the-Line SERIES MP300 Combined Manual and Automatic

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

Epson Stylus. Pro GS6000 QUICK REFERENCE GUIDE

St Elizabeth Health Care 2013 Cidex OPA GUIDELINES. Standardizing Cidex OPA Use For Direct Users

Thank you for choosing the Motif Duo Double Electric Breast Pump. Motif Duo Operation Manual

Fluid Management. On-Demand Summary Printouts Set-Up & Non Pulsatile Flow. For Use In GYN, Urology & Arthroscopy. 42 allenmedical.

Transcription:

G.I. Procedures Scope Culture Protocol Handbook Rev. September 2013 1 *Testing requires two individuals.

Step 1 Broth 1. Contact Memorial Hospital Epidemiology Laboratory two or three days before your scope testing. This is located on the 5 th floor or call 919-843-0867. 2. Order three broth containers per scope. 3. Bring cooler carrying container to keep broth containers cold. 4. Each container returned after testing should have 20 cc or more in order to be properly tested. 5. When testing is completed immediately deliver all specimens back to the Memorial Hospital Epidemiology Laboratory. Step 2 Supplies Needed 1. Two sterile SRI gowns. 2. Two pairs sterile gloves and bonnets. 3. One sterile cover or sterile gown. 4. Two 60 ml Catheter tip syringes. 5. Two 20 ml syringes. 6. Two alcohol 4x4 prep pads packages. 7. Two 3 piece sterile clear tubing. 8. Two sterile suction tubing packs. 9. Two sets of 3 small sterile containers and blank labels. 10. Two sets of 2 specimen traps and blank labels. 11. Two Olympus auxiliary tubing. 12. Two masks with eye shield. 13. Two sets of each red suction button, blue air and water button, black biopsy cap, if testing 180 s scopes water resistant caps (black cap). 14. New suction canister and tubing. 15. Choose two different types of scopes (GIF, PCF, CF etc ) to test. Rev. September 2013 2

Step 3 Scope Items All buttons and black cap need to be attached to scopes before you start culture testing. Wipe all buttons and button scope ports with an alcohol wipe. 1. Suction = Red 2. Air & Water = Blue 3. The Biopsy cap needs to be on the scope before you start the culture testing. Biopsy cap Attach the Biopsy Cap here 4. Water Resistant Caps (Black Cap) needs to be on the180 s and lower series scopes before you start the culture testing. Attach the Black Cap here *Note the 190 s scopes don t have a black cap. Rev. September 2013 3

Step 4 Scope Pre-procedure 1. Get two different scopes (GIF, PCF, CF etc ) that you want to test from the scope room (make sure not to choose from last testing). 2. Be sure you get the 3 scope buttons and water resistant cap (black cap) as well for each scope. 3. Make sure the red suction button goes on top (red circle around hole) and the blue air and water button (blue circle around hole) goes beneath it and place biopsy cap on scope. 4. Label your three specimen cups Air, Water and Auxiliary. 5. Label your Specimen Trap Suction only. 6. Label your specimen cups by recording all scope information on all specimen cups and Flexible Scope Testing log sheet. a. Date each specimen cup b. Initial each specimen cup c. Location: Memorial etc d. Model example: GIF, CF etc e. Scope Serial number f. Who cleaned the scope last 7. Suction canister and cover it with the sterile half sheet. 8. Place your first scope onto your sterile field drape. 9. Put on your Personal Protective Equipment (PPE). 10. Prepare this site by opening and placing all the items listed in Step 2, numbers 4 to 10 listed above onto your second sterile work area. 11. Place your tubing on your syringe. Rev. September 2013 4

Step 5 Scope Culture Testing First Culture the Air Channel 1. Place broth in the 60 ml syringe and attach syringe tubing to the silver suction nozzle (Figure 1). 2. Open appropriate specimen container. 3. Wipe all buttons and button scope ports with an alcohol wipe. 4. Wipe distal end of scope with an alcohol wipe and hold end over collection cup (Figure 2). 5. Push broth through silver suction nozzle while holding down on the red suction button (Figure 3). 6. Immediately close container and set aside. Scope Distal Section Figure 2 Figure 3 Broth Figure 1 Rev. September 2013 5

Step 6 Scope Culture Testing Second Culture the Water Channel 1. Place broth in the 60 ml syringe and attach syringe tubing to the silver suction nozzle (Figure 4). 2. Open appropriate specimen container. 3. Wipe distal end of scope with an alcohol wipe and hold end over collection cup (Figure 5). 4. Push broth through silver suction nozzle while holding down on both the red suction button and the blue air and water buttons (Figure 6). 5. Immediately close container and set aside. Serial Number Silver Suction Nozzle Figure 5 Figure 6 Broth Figure 4 Rev. September 2013 6

Step 7 Scope Culture Testing Third Culture the Auxiliary *Skip this Step 7 if you are testing a scope that does not have an Auxiliary scope port. 1. Attach Olympus auxiliary tubing to the auxiliary scope port (Figure 7). 2. Draw up 20ml syringe of broth. 3. Do NOT hold down any buttons. 4. Push the entire 20ml syringe of broth through the Olympus auxiliary tubing, followed by 2 to 3 times - loaded with just air. Hold distal end of the scope, allowing broth to empty into the specimen container (Figure 8). Figure 8 Figure 7 Broth Auxiliary Tubing Auxiliary Scope Port Rev. September 2013 7

Step 8 Scope Culture Testing Fourth Flushing the Scope 1. Remove all remaining fluid / broth from scope. a. Open suction tubing and place one end on the suction cap on the suction canister. b. Place other end of tubing on the silver suction nozzle of the scope in order to remove any fluid remaining in the scope. Step 9 Scope Culture Testing Fifth Culture the Suction 1. Then remove the suction tubing from the scope and put the tubing of mucous trap container on silver suction nozzle in order to collect broth once it s ran through the channel. 2. Then connect the previous end of the suction tubing onto the small port of the mucous trap container (Figure 9). 3. Wipe the distal end of the scope with an alcohol wipe and turn on the suction canister. Gently place the distal end into the container without touching the sides, and at the same time you are pushing the red suction button only. Be prepared to quickly disconnect the mucous trap container from the scope or the broth will continue to move into the suction canister. 4. Turn off the suction canister. Connect rubber tubing of the mucous trap to small port on the trap in order to make it a closed system. Rev. September 2013 8

Tubing From Canister To Mucous Trap Container Figure 9 Broth Container Mucous Trap Container Silver Suction Nozzle Rev. September 2013 9

No Interruptions Scope Testing Place this sign outside your testing facility. Rev. September 2013 10

Cliff Notes Step 5 Scope Culture Testing Step 7 Scope Culture Testing 1 st Culture the Air Channel 3 rd Culture the Auxiliary Hold down red suction button Do NOT hold down any buttons Step 6 Scope Culture Testing Step 9 Scope Culture Testing 2 nd Culture the Water Channel 5 th Culture the Suction Hold down both the red suction and Hold down the red suction button the blue air and water buttons If you have any questions please contact me at Daniel.keck@unch.unc.edu Rev. September 2013 11