TRX MAINS CONNECTION DIAGRAM

Similar documents
ARROWHEAD ALARM PRODUCTS Ltd. 344b Rosedale Rd, Albany, Auckland. Ph Fax v1.0

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

Proudly Designed and Manufactured in New Zealand. By Arrowhead Alarm Products Ltd

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

2G & 3G GSM Door Contact Alarm

Sentry 4 Zone Alarm Panel User Manual

2G & 3G GSM Portable PIR Alarm

2G & 3G GSM Wireless Beam Alarm

Version 1.03 January-2002 USER S MANUAL

Destiny Destiny Owners Manual

Each reader connected to the Challenger LAN system is programmed as an Arming Station.

Wireless D.I.Y. Alarm Kit

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

ELT-KLED EliteSuite LED Keypad Installation Manual

Wireless Keypad GKP-S8M

Installation & Programming Guide

Addendum for STI-6406 with Dual Access Control

Quick Installation Manual LED 99-Zone Autodial Wireless Alarm System

Using Your. Security System With LED Keypad S5030, S5031, S5032

DSC PowerSeries NEO Quick Start Guide

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

Protégé Eclipse LED Keypad User Manual PRT-KLES

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

SECURITY SYSTEM NOTES

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Control/Communicator Installation Manual

Exit Stopper. STI-6400 Series

ECONX FIT OFF INSTRUCTIONS

LS800S Intruder Alarm System. Engineering Manual

Digiplex LED Keypads User s Manual

EVO192 v3.0 Fire and Burglary What s New


USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

status AW1 Plus WiFi Alarm System User Manual

GSM PROTECT ANTI-THEFT ALARM WITH GPS TRACKING & MOBILE PHONE ALERTS

BURGLAR ALARM PANEL BS-468

NETWORX TM. User manual NX-4

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

Exit Stopper. STI-6400 Series

Wireless Internal Siren System Installation Guide

SERENITY. Crow s Passion for Smart Residential Security.

Kwêbeam GSM/Interface/Repeater Module

MEGA WAY LCD 4-CHANNEL MOTORCYCLE ALARM SECURITY SYSTEM. Operation Manual MEGATRONIX CALIFORNIA, U.S.A. MEGA 3100 OPERATE 1

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

DESTINY OWNER S MANUAL

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

D3D Wi-Fi GSM Smart Alarm System -User Manual

GSM 3G AUTO DIALLER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

Summit 3208GLD USER MANUAL. Electronics Line

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Challenger Series Users Manual

abode Web app Functionality

ALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional:

USER'S OPERATING INSTRUCTIONS

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

REMOTE CONTROL FOR CHILLER MYCHILLER

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

NetworX NX-8V2. LED Keypad User Manual

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

Quick Programmer s Manual

NetworX Series NX-1500E LED Keypad

Easy-Stat. Wireless Programmable Room Thermostat Pt No

U ser's Guide PC6010

With Magictrl, you can control MatiGard anytime & anywhere via your smartphone, even without data network.

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

16 ( Ver: Installation & Programming Guide. Power Wave 16 Zone Control Communicator. Crow Electronic Engineering (Australia) Pty Ltd

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Transponder reader TECHNICAL SHEET (White) (Magnesium)

Ultra-8D. ControlPanel. Operators Manual. Advanced DigitalControls CP108-0M-V1

Owner s Manual. Part Number 33CS250-RC

Power Wave Zone Alarm Panel V8.5. Installation Manual

DESTINY 6100 SERIES SECURITY SYSTEM OWNER S MANUAL V1 12/01

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

FW-SIREN2EXT -8/9F FW-SIREN2CP -8/9F

Installation Manual Premier 412/816/832. Issue 10

Challenger10 Users Manual

DYGIZONE GJD910 Lighting Controller & Enunciator

Digiplex LED Keypads. User s Manual

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

"Pegaso" wireless alarm system D.I.Y. wireless kit

User s Information Guide R2A

General Purpose IO Technical Manual

GSM RFID VOICE Alarm System

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

TABLE OF CONTENTS TABLE OF CONTENTS 1

OWNER S MANUAL. Part Number P RF

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

Model 17A00 Expansion Enclosure

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

"Pegaso" wireless alarm system

TO ARM/DISARM ALARM The alarm is activated by pressing BUTTON 1 on the remote control transmitter once. The blinkers will flash once, and the

VAP304 PRO INSTALLATION & OPERATION MANUAL

COMPASS S3 S2 CALIBRATION

Elite Version. 8 Zone Control Communicator. Installation & Programming Guide. Proudly Designed and Manufactured in New Zealand

INSTRUCTION MANUAL FOR. Remote Control Car Alarm with Impact Sensor, Mini-Battery Backup Siren & Engine Immobiliser

Transcription:

TRX MAINS CONNECTION DIAGRAM Switch 230VAC 10A Neutral Out Phase Out TRX MAINS Phase In Neutral In LOAD 8A MAX. Specifications: Operating Voltage: 220-240VAC 50Hz Current Draw: 5mA Max. Switching Current: 8A Resistive Load, 6A Inductive Load. Frequency: 917.1-921.3 MHz Connection: 1 Neutral In 2 Phase Trigger Input 3 Phase In 4 Switched Phase Output, 8Amp Max. Manufactured by Arrowhead Alarm Products ltd. 344b Rosedale rd, Albany, Auckland, New Zealand Ph.09-414-0085 www.aap.co.nz Page 1

In Wall Installation FLUSH BOX TRX MAINS Page 2

Plastic Enclosure Installation TRX MAINS Optional Trigger Input Use Electrically Approved Plastic Enclosure Only *Do Not Mount TRX-MAINS in a Metal Enclosure. Suitable Enclosures: TB-AG-1010 (100 x 100mm) TB-AG-1115 (110 x 150mm) Page 3

High Current Contactor Wiring *Only use Contactors with 230VAC Coil and Contacts to suit switched load. Mounted inside plastic enclose TB-AG-1115 (110 x 150mm) Neutral In 230VAC Phase In TRX MAINS Optional Override Input Phase Out 230VAC Warning: The TRX Mains relay is not suitable for mounting in accessible locations. It must be installed within an enclosure providing suitable insulation, as shown above. Page 4

2-Way Light Switching Example Existing Wired Solution Switch 1 Switch 2 Neutral Out Phase Out TRX MAINS Phase In Neutral In LOAD 8A MAX. Page 5

TRX MAINS Programming Step 1 Option 1 Pairing to Transceiver using Magnet 1 Safely apply power to the TRX MAINS 2 Present & hold the Magnet next to the TRX MAINS (see diagram a). The TRX MAINS will start beeping as it searches for a device to pair with. 3- Now put the TRX TRANSCEIVER (connected to the ELITE S) into pairing mode, by pressing and holding the red button for 2 seconds (see diagram b). The blue pairing LED should start flashing. 4- The Beeping from TRX MAINS should then stop, indicating pairing is complete. The blue LED on the TRX TRANSCEIVER will stop flashing after 60 seconds, or press the red button to make it stop. diagram b -MAGNET ALIGNMENT- diagram a MAGNET Pairing Button Option 2 Pairing to Transceiver using IR Remote-10 1 Safely apply power to the TRX MAINS 2- Point the IR remote at the bottom of the TRX MAINS (see diagram c) and press P then E. The TRX MAINS will start beeping as it searches for a device to pair with. 3- Now put the TRX TRANSCEIVER (connected to the ELITE S) into pairing mode, by pressing and holding the red button for 2 seconds (see diagram b). The blue pairing LED should start flashing. 4- The Beeping from TRX MAINS should then stop, indicating pairing is complete. The blue LED on the TRX TRANSCEIVER will stop flashing after 60 seconds, or press the red button to make it stop. diagram c QR CODE LINK TO IR-REMOTE Page 6

TRX MAINS Output Assignment Advance Output Mapping (requires IR Remote-10) The Default Assigned Output for the TRX MAINS is 8, to change this please follow the steps below: 1 Safely apply power to the TRX MAINS 2- Point the IR remote at the bottom of the TRX MAINS and press P followed by the Output you wish to Map it to (1-8) then E. The TRX MAINS should give a triple beep indicating this was successful. Note. It is not recommended to Map to Output 1 or 2 as they are for Sirens by default. 3- Make a note of this number here and on the TRX MAINS. Note. Multiple TRX MAINS can be paired to the same Output. *With an Output Assigned in to the TRX MAINS it s Trigger Input is not Directly linked to the Switched Output. If you wish the Trigger Input to activate the Switched Output you must program it into the Elite S Panel. Default 8 Programming Trigger Input to Switched Output Link with ESL Control Board The ESL v908.12c has pre assigned slots for the TRX Mains devices. If you have an Elite-S or Elite-S-Lite Control board v908.12b or older please use programming on page 8 Follow the list below for the Addresses that relate to the TRX Mains Output number assigned: 3 1 Learn State 1 (ON) to the first User slot P 18 E 90 E E (when beeping starts flick the switch connected to the TRX Mains On) 2 Learn State 2 (OFF) to the second User slot. if you have a momentary switch, skip this step P 18 E 91 E E (when beeping starts flick the switch connected to the TRX Mains Off) 3 Adjusting Output Reset Time, the default reset time is only 2 seconds. P 40 E 3 E 0 E (lights now will not automatically turn off) 5 1 Learn State 1 (ON) to the first User slot P 18 E 92 E E (when beeping starts flick the switch connected to the TRX Mains On) 2 Learn State 2 (OFF) to the second User slot. if you have a momentary switch, skip this step P 18 E 93 E E (when beeping starts flick the switch connected to the TRX Mains Off) 3 Adjusting Output Reset Time, the default reset time is only 2 seconds. P 40 E 5 E 0 E (lights now will not automatically turn off) 6 1 Learn State 1 (ON) to the first User slot P 18 E 94 E E (when beeping starts flick the switch connected to the TRX Mains On) 2 Learn State 2 (OFF) to the second User slot. if you have a momentary switch, skip this step P 18 E 95 E E (when beeping starts flick the switch connected to the TRX Mains Off) 3 Adjusting Output Reset Time, the default reset time is only 2 seconds. P 40 E 6 E 0 E (lights now will not automatically turn off) 7 1 Learn State 1 (ON) to the first User slot P 18 E 96 E E (when beeping starts flick the switch connected to the TRX Mains On) 2 Learn State 2 (OFF) to the second User slot. if you have a momentary switch, skip this step P 18 E 97 E E (when beeping starts flick the switch connected to the TRX Mains Off) 3 Adjusting Output Reset Time, the default reset time is only 2 seconds. P 40 E 7 E 0 E (lights now will not automatically turn off) 8 1 Learn State 1 (ON) to the first User slot P 18 E 98 E E (when beeping starts flick the switch connected to the TRX Mains On) 2 Learn State 2 (OFF) to the second User slot. if you have a momentary switch, skip this step P 18 E 99 E E (when beeping starts flick the switch connected to the TRX Mains Off) 3 Adjusting Output Reset Time, the default reset time is only 2 seconds. P 40 E 8 E 0 E (lights now will not automatically turn off) Page 7

Assigning Input Control with Elite-S & Elite-S-Lite PCB Choose 2 Spare User Slots from 21 to 100 and put them in where you see these boxes Don t Do this programming if you have an ESL-PCB v908.12c (use page 7 instead) Ua Ub 1 Learn State 1 to the first User slot P 18 E E (when beeping starts flick the switch connected to the TRX Mains On) Ua 2 Learn State 2 to the second User slot. if you have a momentary switch, skip this step and 8 to 11 P 18 E E (when beeping starts flick the switch connected to the TRX Mains Off) Ub 3 Set the User Assignment State 1 (by default all user slots Arm and Disarm, this needs to be changed) P 4 E E turn Off all options E Ua 4 Output Mapping for State 1 P 12 E E E Ua 5 Output On Command for State 1 P 13 E E E Ua 6 Output Off Command for State 1 P 14 E E E Ua 7 Output Permission P 34 E E turn On option 6 E Ub 8 Output Reset Time P 40 E E turn On option 6 E 9 Set the User Assignment P 4 E E turn Off all options E 10 Output Mapping for State 2 P 12 E E E Ub 11 Output On Command for State 2 P 13 E E E Ub 12 Output Off Command for State 2 P 14 E E E Ub Range Test Once you have learnt the Trigger Input into the panel, a range test is recommended P 200 E 14 E E now Activate the Trigger Input The User Slot it has been loaded into will flash up and a percentage. 100% full signal strength. Note. Repeat the process for each TRX MAINS device, If less than 30% consider relocating the TRX Transceiver to get better signal strength. Page 8

Group Mode Programming If Group Mode has been selected, the TRX MAINS will turn On when Output 7 from the panel turns On and will turn Off when Output 8 from the panel turns On. This allow multiple TRX MAINS modules all set to Group Mode to turn off and on together from a panel request, such as: Arming/Disarming the alarm, Fire/Burglar alarm activation, Timer control. In Group Mode the Trigger Input is always directly linked to the Switched Output. A change in state of the Trigger Input will change the Switched Output state, regardless of what position the switch is in. Selecting Group Mode To set a TRX MAINS to Group Mode you must use the IR-Remote-10 1 Safely apply power to the TRX MAINS 2- Point the IR remote at the bottom of the TRX MAINS (see diagram c) and press P, 0 then E. The TRX MAINS will give a triple beep if accepted. Programming Options Lights Off when System is Armed P 47 E 1 E (turn 8 On) E Lights On when System is Disarmed P 49 E 1 E (turn 7 On) E Lights On when Fire Alarm Activates P 130 E (zone No. of smoke detector 1-16) E (turn 7 On) E (must be done for each 24-hour Fire zone) Lights On when Burglar Alarm Activates P 128 E (zone No. of detector 1-16) E (turn 7 On) E (must be done for each zone/detector) Lights On when Stay Burglar Alarm Activates P 129 E (zone No. of detector 1-16) E (turn 7 On) E (must be done for each zone/detector) Page 9

Heated Towel Rail Wiring To Heated Towel Rail 8A Max. Optional Override Input TRX MAINS Earth In Neutral In Phase In Mounted inside plastic enclose TB-AG-1010 (100 x 100mm) Warning: The TRX Mains relay is not suitable for mounting in accessible locations. It must be installed within an enclosure providing suitable insulation, as shown above. Page 10

Smart Features Automatic On/Off timer (Recommended for Heated Towel Rail) There are 8 different On/Off timers that can be set in the Elite-S series control panel. Before starting the Programming steps below make sure the TRX Mains has been paired to the TRX Transceiver (see page 6) and an Output number has been assigned (see page 7). 1 Set On Time 1. P 172 E 1 E (enter start time is 24hr format 0000-2359) E 2- Set Off Time 1. note Off time must be after On time. P 173 E 1 E (enter finish time is 24hr format 0000-2359) E 3- Set Timer 1 Days of Week. P 171 E 1 E (put in day active days 1-7, see table) E 4- Assign Timer 1 to an Output. P 44 E (enter output number ) E 1 E 5 Changing Reset Timer of Output. P 40 E E 0 E Need another On and Off sequence? Follow the steps below. 6 Set On Time 2. P 172 E 2 E (enter start time is 24hr format 0000-2359) E 7- Set Off Time 2. note Off time must be after On time. P 173 E 2 E (enter finish time is 24hr format 0000-2359) E 8- Set Timer 2 Days of Week. P 171 E 2 E (put in day active days 1-7, see table) E 9- Assign Timer 2 to an Output. P 44 E (enter output number) E 2 E No. Day 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday Automatic Turn Lights Off when System Arms Each Output (TRX MAINS) can be Selected to turn Off when the Alarm System is Armed. P 54 E 1 E E (each TRX Mains number can be turned on here) Note. Don t turn on 1 or 2 this will trigger the sirens Adjusting Lights On Exit Timer Once you have turned On the option above, you can choose to extend the Off delay time up to 25 seconds. This will give you an illuminated exit from the property before turning the lights Off. Each Output (TRX MAINS) can be adjusted individually. P 39 E E time in 10ths/second 1-255 E (250 25seconds) Note. Repeat the process for each TRX MAINS you wish to have this feature Fallback Feature If communication is lost to the TRX Transceiver, the TRX Mains will automatically Fallback and operating directly from it s Trigger Input. Page 11

Warning! This unit contains no user serviceable parts, it must be returned to the manufacture if it fails to operate or the cable is damaged. Install only as per manufactures instructions and/or in recommended enclosure. ARROWHEAD ALARM PRODUCTS Ltd. 344b Rosedale Rd, Albany, Auckland. Ph. 09 414 0085 Fax. 09 414 0088 www.aap.co.nz v1.01 Page 12