4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

Similar documents
4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

Service Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Service Facts. Split System Heat Pump 4A6H5019H-SF-1C-EN. August A6H5019H1000A

Split System Cooling Product & Performance Data

Product Data. Split System Heat Pump B-EN. February A6H6024H1000A

Product Data. Split System Cooling A. November 2013

Product Data. Split System Cooling D-EN. August 2016

Product Data. Split System Heat Pump D-EN. February 2016

Product Data. Split System Cooling H-EN. January 2017

Product Data. Split System Cooling E-EN. November 2016

Product Data. Split System Heat Pump A-EN. March 2016

3-11/ /8 4-5/16 6-5/8 5-7/8 1-9/16. Condensate drain connection 3/4 NPTI (Trap required) Electrical service access compartment panel

Product Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A

Product Data. Split System Heat Pump

Service Facts. Air Handler - Convertible Model: Series 2 Air Handlers ton GAT2A0B42S31SA GAT2A0C48S41SA GAT2A0C60S51SA WARNING: GAT2-SF-1B

Product Data Split System Cooling

Split System Cooling Product Data XB 1000

Product Data. Split System Heat Pump 4TWR4018G1000A 4TWR4024G1000A 4TWR4030G1000A 4TWR4036G1000A 4TWR4042G1000A 4TWR4048G1000A 4TWR4060G1000A

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Heat Pump Product Data

Split System Heat Pump Product Data

Split System Heat Pump Product Data

AMERICAN STANDARD 14 MODELS 4A7B E

Split System Heat Pump Product Data

Product catalog. Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4

Split System Cooling Product Data

SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product & Performance Data

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

Split System Heat Pump Product & Performance Data

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Split System Heat Pump Product Data

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

Modular Multi-position Air Handler

Split System Cooling Product Data

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

SPLIT SYSTEM HEAT PUMP 2, 3, 4 & 5 ton HERITAGE 20 MODELS 4A6Z0024, 036, 048, & 060A. with AccuLink and Charge Assist

Split System Heat Pump Product Data

Submittal. Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A-SUB-1A-EN. March WCY5024A1000A TAG:

Split System Cooling Product Data

Split System Cooling Product Data

Cooling/Heat Pump Convertible Air Handlers

Variable Speed Convertible Air Handler 5 Ton

Vertical Upflow Horizontal Left Air Handlers

Split System Cooling Product Data

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A

Product Data. Convertible Air Handlers 1 1/2 5Ton

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Cooling/Heat Pump Convertible Air Handlers

Commercial High-Efficiency Condensing Units

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Variable Speed Convertible Air Handler 2 1/2 Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton

36,000-62,000 BTUH Nominal Capacity

Variable Speed Convertible Air Handler 4 Ton

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

Cooling/Heat Pump Convertible Air Handlers

Commercial High-Efficiency Condensing Units

Product Data WCZ6036B through 4WCZ6060B Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

Service Facts WARNING: GAM5-SF-1D. Convertible Air Handlers ! WARNING

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

Hyperion TM Split Systems

Appendix J Noise Appendix

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

R4H4. Product Specifications

Product Data YCZ6036A through 4YCZ6060A Single Packaged Convertible Gas/Electric 16 SEER 3, 4 & 5 Ton, MBTU R-410A

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Modular Multi-position Air Handlers

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

Modular Multi-position Air Handlers

Corp L9 Revised HS27 SERIES UNITS SPECIFICATIONS. Model No. HS HS HS HS27-042

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

4YCC3048A3096A /3/ /

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Transcription:

Service Facts Split System Cooling 4TTB3048D1000B, 4TTB3060D1000B CAUTION IMPORTANT This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit. Please return to service information pack upon completion of work. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE CAPACITORS BEFORE SERVICING OUTDOOR UNIT 12 POWER CONNS. V/PH/HZ 3 MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. MAX. (AMPS) COMPRESSOR. USED -. SPEEDS VOLTS/PH/HZ R.L. AMPS 7 - L.R. AMPS FACTORY INSTALLED START COMPONENTS 8 INSULATION/SOUND BLANKET COMPRESSOR HEAT OUTDOOR FAN DIA. (IN.) -. USED TYPE DRIVE -. SPEEDS CFM @ 0.0 IN. W.G. 4. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS OUTDOOR COIL TYPE ROWS - F.P.I. FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT LBS. R-410A (O.D. UNIT) 5 FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS 6 LINE SIZE - IN. O.D. LIQ. 6 CHARGING SPECIFICATION SUBCOOLING DIMENSIONS CRATED (IN.) WEIGHT SHIPPING (LBS.) NET (LBS.) PRODUCT SPECIFICATIONS 4TTB3048D1000B 208/230/1/60 28 50 SCROLL 1-1 208/230/1/60 21.8-117 PROPELLER 27.5-1 DIRECT - 1 3969 1-1/5 835 200/230/1/60 0.93 SPINE FIN 1-24 19.07 3/8 6 LBS., 13 OZ. 7/8 3/8 10 F H X W X D 34.4 x 35.1 x 38.7 235 203 4TTB3060D1000B 208/230/1/60 35 60 SCROLL 1-1 208/230/1/60 26.8-134 PROPELLER 27.5-1 DIRECT - 1 4342 1-1/5 835 200/230/1/60 0.93 SPINE FIN 1-24 24.93 3/8 8 LBS., 0 OZ. 7/8 3/8 10 F H X W X D 42.4 x 35.1 x 38.7 261 226! 4TTB3-SF-3 UNIT CONTAINS R-410A REFRIGERANT! R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS REQUIRED. FAILURE TO USE PROPER SERVICE TOOLS MAY RESULT IN EQUIPMENT DAMAGE OR PERSONAL INJURY. SERVICE USE ONLY R-410A REFRIGERANT AND APPROVED POE COMPRESSOR OIL. TUBING INFORMATION Tubing Sizes Tubing Suction Liquid Length 20 30 40 50 60 Tubing lengths in excess of sixty (60) feet see application software. Additional Refrigerant 3 oz. 9 oz. 16 oz. 22 oz. 28 oz. 1 Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program, which is based on AHRI standard 210/240. 2 Rated in accordance with AHRI standard 270. 3 Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses. 4 Standard Air Dry Coil Outdoor 5 This value approximate. For more precise value see unit nameplate. 6 Max. linear length 60 ft.; Max. lift - Suction 60 ft.; Max lift - Liquid 60 ft. For greater length consult refrigerant piping software Pub. No. 32-3312-0* (* denotes latest revision). 7 This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. 8 No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter.! CAUTION HOT SURFACE! DO T TOUCH TOP OF COMPRESSOR. May cause minor to severe burning.! CAUTION CONTAINS REFRIGERANT! SYSTEM CONTAINS OIL AND REFRIGERANT UNDER HIGH PRESSURE. RECOVER REFRIGERANT TO RELIEVE PRESSURE BEFORE OPENING SYSTEM. Failure to follow proper procedures can result in personal illness or injury or severe equipment damage.! WARNING THIS INFORMATION IS INTENDED FOR USE BY INDIVIDUALS POSSESSING ADEQUATE BACKGROUNDS OF ELECTRICAL AND MECHANICAL EXPERIENCE. ANY ATTEMPT TO REPAIR A CENTRAL AIR CONDITIONING PRODUCT MAY RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE. THE MANUFACTURER OR SELLER CANT BE RESPONSIBLE FOR THE INTERPRETATION OF THIS INFORMATION, R CAN IT ASSUME ANY LIABILITY IN CONNECTION WITH ITS USE. TICE: The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. 2011 Trane! CAUTION RECONNECT ALL GROUNDING DEVICES. ALL PARTS OF THIS PRODUCT CAPABLE OF CONDUCTING ELECTRICAL CURRENT ARE GROUNDED. IF GROUNDING WIRES, SCREWS, STRAPS, CLIPS, NUTS OR WASHERS USED TO COMPLETE A PATH TO GROUND ARE REMOVED FOR SERVICE, THEY MUST BE RETURNED TO THEIR ORIGINAL POSITION AND PROPERLY FASTENED. 07/11

SCHEMATIC DIAGRAM SUBCOOLING CHARGING IN COOLING ABOVE 55 F OD AMBIENT The manufacturer has always recommended installing matched indoor and outdoor systems. All split systems are AHRI rated with only TXV indoor systems. The benefits of installing approved indoor and outdoor split systems are maximum efficiency, optimum performance and the best overall system reliability. The following charging methods are therefore prescribed for systems with indoor TXVs. 1. Subcooling (in the cooling mode) is the only recommended method of charging above 55 F ambient temperatures. 2. For best results the indoor temperature should be kept between 70 F to 80 F. Add system heat if needed. 3. At startup, or whenever charge is removed or added, the system must be operated for a minimum 20 minutes to stabilize before accurate measurements can be made. 4. Measure Liquid Line Temperature and Refrigerant Pressure at service valves. 5. Determine total refrigerant line length, and height (lift) if indoor section is above the condenser. 6. Determine the Design Subcool Charging Temperature from the unit nameplate. 7. Locate this value in the appropriate column of the Subcooling Charging Table. Locate your liquid line temperature in the left column of the table, and the intersecting liquid line pressure under your nameplate subcool value column. Add refrigerant to raise the pressure to match the table, or remove refrigerant to lower the pressure. Again, wait 20 minutes for the system conditions to stabilize before adjusting charge again. 8. When system is correctly charged, you can refer to System Pressure Tables (on page 7) to verify typical performance.

WIRING DIAGRAM 4 Ton Subcooling Charging Table REFRIGERANT LINE LIFT (FEET) SUBCOOL CHARGING CHART CORRECTIONS TABLE (FOR LINE LENGTH AND RISE) 60 50 40 30 25 Add 3º Add 6º Add 5º Add 4º Add 7º Add 6º Add 5º Add 3º 20 15 10 Add 1º Use Design Subcool Value (10º) Add 2º 0 10 20 25 30 40 60 80 TOTAL REFRIGERANT LINE LENGTH (FEET) 5 Ton Subcooling Charging Table REFRIGERANT LINE LIFT (FEET) SUBCOOL CHARGING CHART CORRECTIONS TABLE (FOR LINE LENGTH AND RISE) 60 50 40 30 25 20 15 10 Add 2º Add 1º Use Design Subcool Value (10º) Add 5º Add 4º Add 3º Add 2º Add 1º Add 6º Add 5º Add 4º Add 3º Add 2º Add 1º 0 10 20 25 30 40 60 80 TOTAL REFRIGERANT LINE LENGTH (FEET) LIQUID TEMP ( F) R-410A REFRIGERANT CHARGING CHART DESIGN SUBCOOLING ( F) 8 9 10 11 12 13 14 LIQUID GAGE PRESSURE (PSI) 55 179 182 185 188 191 195 198 60 195 198 201 204 208 211 215 65 211 215 218 222 225 229 232 70 229 232 236 240 243 247 251 75 247 251 255 259 263 267 271 80 267 271 275 279 283 287 291 85 287 291 296 300 304 309 313 90 309 313 318 322 327 331 336 95 331 336 341 346 351 355 360 100 355 360 365 370 376 381 386 105 381 386 391 396 402 407 413 110 407 413 418 424 429 435 441 115 435 441 446 452 458 464 470 120 464 470 476 482 488 495 501 125 495 501 507 514 520 527 533 Refer to Service Facts or Installer's Guide for charging method. From Dwg. D154557P01 Rev. 2

TROUBLESHOOTING Compressor fails to start Contactor check Is contactor energized? (contacts closed) Go To: Compressor won t run Check for 24 volts AC across contactor coil Is voltage present at contactor coil? Replace contactor Check control transformer and control fuse Is the control transformer and fuse good? Jumper R to Y low voltage terminals at thermostat sub base. Does the contactor energize? Replace the room thermostat Repair or replace transformer or fuse. Investigate cause for failure (possible short in field wiring) Repair or replace connecting wiring Single Pole Contactor (MS)* Double Pole Contactor (MS)* OUT T2 T1 T2 T1 OUT HIGH VOLTAGE Contactor Coil 24 VAC HIGH VOLTAGE IN L2 L1 L2 L1 IN *Refer to Wiring Diagram to determine if a single pole or double pole contactor is used.

TROUBLESHOOTING Compressor won t run Contactor is closed Check for high voltage to contactor Is high voltage present at T1 and T2? Check for open IOL (Internal Overload) Check resistance of C to S and C to R Check power supply from disconnect and/or breaker panel. Does the resistance check show an open circuit from C to S or C to R? Allow compressor time to cool and re-test Check for open windings. Does a resistance check show an open circuit between R and S? Replace the compressor Check for locked rotor Is voltage present at C to S and C to R with locked rotor amps on C? Check Start- Capacitor and Relay (if present) and Run Capacitor Check wiring to compressor C, S and R Do the start components and run capacitor check good? Replace the compressor Replace start components and/ or run capacitor

REFRIGERANT CIRCUIT 4TTB3048D Printed from C151867 REFRIGERANT CIRCUIT 4TTB3060D FIELD INSTALLED INTER-CONNECTING TUBING OUTDOOR SECTION OUTDOOR COIL INDOOR SECTION 1/4 FLARE PRESSURE TAP REFRIGERANT FLOW SUCTION LINE INDOOR COIL FIELD CONNECTION COMPRESSOR CHECK VALVE 1/4 FLARE PRESSURE TAP LIQUID LINE DRIER DISCHARGE LINE EXPANSION VALVE (OR FCCV) REFRIGERANT FLOW FIELD CONNECTION Printed from C151866

PRESSURE TABLES FOR 4TTB30**D1 4TXC****BC cooling with Thermal Expansion Valve Outdoor Temperature (Degree F) Outdoor Size & Coil OD ** 18 24 30 36 42 3 48 60 Coil **** A018 B025 B031 B036 C043 C049 D064 Liquid Pressure (PSIG) 115 490 495 495 495 505 110 455 460 465 460 475 105 435 440 435 435 450 100 405 410 405 405 420 95 380 380 380 380 390 901 355 355 355 4 350 365 85 330 335 330 330 340 80 310 310 305 305 320 75 285 290 290 285 295 70 270 270 255 265 280 65 250 250 245 245 255 60 230 230 230 230 235 Outdoor Size & Coil OD ** 18 24 30 36 42 3 48 60 Coil **** A018 B025 B031 B036 C043 C049 D064 Outdoor Temp. (Degree F) 110 100 90 1 80 70 60 Indoor Wet Bulb (Degree F) Suction Pressure (PSIG) 71 152 153 152 153 150 67 143 144 142 145 141 63 135 135 133 136 132 59 126 127 124 128 124 71 147 148 147 149 146 67 139 140 138 140 136 63 130 131 129 131 128 59 122 123 121 123 119 71 144 145 144 145 142 67 2 135 136 135 4 136 132 63 127 127 126 128 124 59 119 119 117 120 116 71 141 141 141 142 138 67 132 133 132 129 129 63 124 125 123 125 121 59 116 117 115 117 113 71 138 138 138 138 135 67 129 130 129 130 126 63 121 122 121 122 118 59 113 114 112 114 110 71 134 135 135 135 132 67 126 127 126 127 123 63 118 119 118 119 115 59 110 110 110 112 107 COOLING PERFORMANCE CAN BE CHECKED WHEN THE OUTDOOR TEMP IS ABOVE 65 DEG F. TO CHECK COOLING PERFORMANCE, SELECT THE PROPER INDOOR CFM, ALLOW PRESSURES TO STABILIZE. MEASURE INDOOR WET BULB TEMPERATURE, OUTDOOR TEMPERATURE, LIQUID AND SUCTION PRESSURES. ON THE TABLE LOCATE OUTDOOR TEMPERATURE (1); LOCATE INDOOR WET BULB (2); LOCATE MODEL OUTDOOR. (3); FIND INTERSECTION BETWEEN 1, 2, & 3 (4) FIND TARGET PRESSURE. EXAMPLE: (1) OUTDOOR TEMP. 90 F. (2) INDOOR WET BULB 67 F. (3) OD 4TTB3042 ACTUAL: (4) LIQUID PRESSURE IS 355 PSIG LIQUID PRESSURE SHOULD BE +/- 10 PSI OF CHART (5) SUCTION PRESSURE IS 135 PSIG SUCTION PRESSURE SHOULD BE +/- 3 PSIG OF CHART

The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. 07/11