Installer's Guide. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE YCC-IG EB23D1-12

Similar documents
Installer's Guide. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE YCC-IG EB23D1-11

Installer's Guide. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE YCC-IG-4

Installer's Guide. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4YCZ6-IG-8-EN 18-EB28D1-8-EN

Installer's Guide. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES. 4TCY4024 through 4TCY4060

Installer s Guide CRS-2500 Single Packaged Two Stage Indirect-Direct Evaporative Cooler 2500 CFM (4250 CMH)

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

Installer's Guide. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 18-BB35-D1-14 4WCZ6-IG-14

80% and 95% furnace models feature aluminized steel heat exchangers to conduct heat quickly and increase durability.

INSTALLER S GUIDE WARNING: TWE-IN-2A 18-GE02D1-3. Convertible 1 ½ - 5 Ton Air Handlers WARNING HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

USER S INFORMATION MANUAL

HWX GAS BOILERS USER S INFORMATION MANUAL

EL195DFE SERIES GAS FURNACE WARNING

EL195UH SERIES GAS FURNACE WARNING

USER'S INFORMATION MANUAL

Bosch 80% AFUE Gas Furnace BGS80 Model

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

USER'S INFORMATION MANUAL

Fig. 1 - Unit PGD4, PGS4, WPG4

WARNING FIRE OR EXPLOSION HAZARD.

Owner s Information Manual

ML180UH SERIES GAS FURNACE WARNING WARNING

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Installer's Guide. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 18-EB25D1-15 TCC-IG-15

EL195UHE SERIES GAS FURNACE WARNING WARNING

G61MPV SERIES GAS FURNACE WARNING

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS)

WARNING FIRE OR EXPLOSION HAZARD.

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL

INSTALLATION OPERATION MAINTENANCE

EL296UHV SERIES GAS FURNACE WARNING WARNING

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

FGR. Installation, Operation and Startup Instruction Manual FOR FLUE GAS RECIRCULATION SYSTEM. FGR-8 through FGR-22 (25 HP to 1000 HP)

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS:

CINCINNATI, OH USA

Installer's Guide. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 18-EB25D1-1

SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE WARNING WARNING

Owner's Guide to Operating and Maintaining Your Gas/Electric Unit

INSTALLATION INSTRUCTIONS

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

USER S INFORMATION MANUAL SLP98UHV SERIES

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

12a. Replacement parts. GOLD CGs Gas-Fired Water Boiler Boiler Manual. Section assembly Base Jacket Trim Controls...

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

Installation / Operation. Applies to: Standard Power Vent Unit Heaters: Separated Combustion Unit Heaters:

User s Information Manual

GBX GAS BOILERS USER S INFORMATION MANUAL

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Combination Cooling/Gas Heat Package Units

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

PL Series Premier Indoor Plenum Coils

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

USER'S MANUAL PGE Single Package Rooftop

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.

NATURAL GAS CONVERSION KIT

Installer's Guide. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 18-EB25D1-12 TCC-IG-12

INSTALLER'S GUIDE MASONRY CHIMNEY VENT KIT WARNING: BAYVENT800B 18- CH23D2-05

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

OPERATING INSTRUCTIONS AND OWNER S MANUAL

Installation Instructions

ULTRA-MAX GAS RADIANT CHARBROILER. ULTRA-MAX GAS LAVA ROCK CHARBROILER MODELS 8024CBB, 8036CBB, 8048CBB, 8060CBB, and 8072CBB

Installation Guide. 5 Series VGC and VGSU Built-In Gas Cooktops

DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

SHILOH. ALSU24F1-2 Shown

STONE RIVER. The White Mountain Log Collection: LSU24SF-2 Shown

User's Information Manual Customer Property: Contains wiring and service information.

INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL

User's Infomation Manual

Installation Instructions Remote Blowers

*p * HWC4 Model THRU-THE-WALL UNIT INSTALLATION INSTRUCTIONS WARNING WARNING WARNING WARNING CAUTION CAUTION TABLE OF CONTENTS

*DD2B060A9V3VA *DD2B080A9V3VA *DD2C100A9V5VA *DD2D120A9V5VA

Installer's Guide. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 18-EB24D1-1

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Installation Instructions

C7 Series Split System Uncased Indoor Coils

The White Mountain Log Collection BIRCH

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

USER MANUAL Gas Countertop Charbroilers

Using it in an enclosed space can kill you.

INSTALLATION INSTRUCTIONS

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Viking Installation Guide

Installation Instructions Dual Fuel Ranges

PROPANE FORCED AIR. HEATER operation manual HL060F HL125F

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

USER S INFORMATION MANUAL

Service Instructions. DCG Gas Electric/DCC Cooling/DCH Heat Pumps Commercial Package Units with R-410A Refrigerant 3-6 Tons & Accessories

100% Safety Shutoff Control 40,000 BTUH Input Rating Constant Pilot Propane Gas

INSTALLATION, OPERATION, AND MAINTENANCE GUIDE

INSTALLATION & OPERATION MANUAL FOR Achiever Charbroilers

SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT

User s Manual & Operating Instructions

INSTALLATION INSTRUCTIONS

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater

Transcription:

Installer's Guide YCC-IG-12 18-EB23D1-12 Single Packaged Gas/Electric 13 SEER Convertible, 1½ - 5 Ton, 40-120 MBTU R-410A ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES IMPORTANT This Document is customer property. Please return to service information pack and give this Installer's Guide to the homeowner upon completion of work. 4YCC3018 through 4YCC3060 4YCX3018 through 4YCX3060 SAFETY HAZARD! This information is for use by individuals having adequate backgrounds of electrical and mechanical experience. Any attempt to repair a central air conditioning product may result in personal injury and/or property damage. The manufacturer or seller cannot be responsible for the interpretation of this information, nor can it assume any liability in connection with its use. HAZARDOUS GASSES! Exposure to fuel substances, or by-products of incomplete fuel combustion, is believed by the state of California to cause cancer, birth defects, or other reproductive harm. This warning complies with State of California law, Proposition 65. This product must be gas piped by a Licensed Plumber or Gas Fitter in the Commonwealth of Massachusetts. HAZARDOUS VOLTAGE, MOVING PARTS, AND GAS! Bodily injury can result from high voltage electrical components, fast moving fans, and combustible gas. For protection from these inherent hazards during installation and service, the electrical supply must be disconnected and the main gas valve must be turned off. If operating checks must be performed with the unit operating, it is the technicians responsibility to recognize these hazards and proceed safely. SAFETY HAZARD! Do not operate the unit without the evaporator fan or coil access panels in place. Reinstall the access panels after performing maintenance procedures on the fan. Operating the unit without the access panels properly installed may result in severe personal injury or death. : HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE CAPACITORS BEFORE SERVICING

Safety Considerations IMPORTANT: Read this entire manual before beginning installation procedures. NOTICE Warning and Cautions appear at appropriate locations throughout this guide. Read these carefully. : INDICATES A POTENTIALLY HAZ- ARDOUS SITUATION WHICH, IF NOT AVOID- ED, COULD RESULT IN DEATH OR SERIOUS INJURY. CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices and where property-damage-only accidents could occur. PRECAUTIONARY MEASURES Avoid breathing fiberglass dust Use a NIOSH approved dust/mist respirator Avoid contact with the skin or eyes. Wear long-sleeved, loose fitting clothing, gloves, and eye protection. Wash clothes separately from other clothing, rinse washer thoroughly. Operations, such as sawing, blowing, tear-out, and spraying may generate fiber concentrations requiring additional respiratory protection. Use the appropriate NIOSH approved respirator in these situations. FIRST AID MEASURES Eye Contact: Flush eyes with water to remove dust. If symptoms persist, seek medical Skin Contact: This product contains fiberglass wool insulation! Fiberglass dust and ceramic fibers are believed by the state of California to cause cancer through inhalation. Glasswool fibers may also cause respiratory, skin, or eye irritation. attention. Wash affected area gently with soap and warm water after handling. CONTAINS REFRIGERANT! SYSTEM CONTAINS OIL AND REFRIGERANT UNDER HIGH PRESSURE. RECOVER REFRIGERANT TO RELIEVE PRESSURE BEFORE OPENING SYSTEM. Failure to follow proper procedures can result in personal illness or injury or severe equipment damage. Unit contains R-410A Refrigerant! R-410A operating pressure exceeds the limit of R-22. Proper service equipment is required. Failure to use proper service tools may result in equipment damage or personal injury. SERVICE Use only R-410A Refrigerant and approved POE compressor oil. Improper Unit Lift! Test lift unit approximately 24 inches to verify proper center of gravity lift point. To avoid dropping of unit, reposition lifting point if unit is not level. Failure to properly lift unit could result in death or serious injury or possible equipment or property-only damage. CAUTION RECONNECT ALL GROUNDING DEVICES. All parts of this product that are capable of conducting electrical current are grounded. If grounding wires, screws, straps, clips, nuts, or washers used to complete a path to ground are removed for service, they must be returned to their original position and properly fastened. CAUTION Hot Surface! Do Not touch top of compressor. May cause minor to severe burning. CAUTION Never use combustible cleaning fluids on any part of the furnace. EXPLOSION HAZARD! Propane gas is heavier than air and may collect in any low areas or confined spaces. In addition, odorant fade may make the gas undetectable except with a warning device. If the gas furnace is installed in a basement, an excavated areas or a confined space, it is strongly recommended to contact a gas supplier to install a gas detecting warning device in case of leak. The manufacturer of your furnace does not test any detectors and makes no representations regarding any brand or type of detector. Page 2 EXPLOSION HAZARD! To prevent an explosion or possible injury, death, and equipment damage, do not store combustible materials, gasoline, or other flammable vapors or liquids near the unit. IMPORTANT: Do not connect gas piping to the unit until a line pressure test has been completed. This unit should never be exposed to gas line pressure in excess of 14 inches water column (1/2 PSIG). The furnace and its equipment shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi. IMPORTANT: Wear appropriate gloves, arm sleeve protectors, and eye protection when servicing or maintaining this equipment.

Contents Safety Considerations 2 Introduction 3 Step 1-Inspect Shipment 3 Step 2-Determine Unit Clearances 4 Step 3-Review Location and Recommendation Information 16 Step 4-Unit Installation 17 Install Flue Hood 17 Ground Level Installation 17 Rooftop Installation -- Curb Mounting 17 Covert Horizontal Airflow to Down Airflow 17 Install Full Perimeter Roof Mounting Curb 17 Lifting and Rigging 18 Placing the Unit on the Mounting Curb 18 Rooftop Installation -- Frame Mounting 19 Rooftop Installation -- No Curb/Frame 19 Ductwork Installation 22 Attaching Downflow Ductwork to Roof Curb 22 Attaching Downflow Ductwork to Roof Frame 22 Attaching Horizontal Ductwork to Unit 22 Condensate Drain Piping 22 Gas Piping Installation 23 Pipe Delivery Schedule (natural gas only) 23 Gas Pressure Set-up Precautions 23 Gas Supply Line Pressure (all fuels) 23 Verify Manifold Pressure 24 Input Check and Adjustment 24 High Altitude Installation 25 Air Filter Installation 25 Electrical Wiring 26 Electrical Connections 26 Electrical Power 26 Disconnect Switch 26 Over current Protection 26 Power Wiring 26 Control Wiring (Class II) 27 Thermostat Heat Anticipator 27 Field Wiring Diagram 27 Step 5-Unit Startup 27 Pre-start Quick Checklist 27 Starting the Unit in the Cooling Mode 29 Operating Pressures 29 Voltage Check 29 Cooling Shutdown 29 Starting the Unit in Gas Heating Mode 29 Final Installation Checklist 29 Sequence of Operation 30 Maintenance 30 Owner Maintenance 30 Service Maintenance 31 Cooling Season 31 Heating Season 31 Flue Hood and Combustion Blower Cleaning 31 Indoor Fan Motor Speed Tap Setting 32 Status LEDs 32 Introduction Installer s Guide Read this manual carefully before attempting to install, operate, or perform maintenance on this unit. Installation and maintenance should be performed by qualified service technicians only. Do NOT use this furnace for temporary heating of buildings under construction. As shipped from the factory, this unit is for use with natural gas only. It is listed by Underwriters Laboratory. An LPG conversion kit is available. A high altitude installation kit of additional orifice sizes is available. An extreme mounting kits for slab and curbs are also available. Packaged units are designed for outdoor mounting with a vertical condenser discharge. They can be located either at ground level or on a roof in accordance with local codes or National Fuel Gas Code (ANSI-Z223.1A) Latest Revision. Since these units are designed exclusively for outdoor operation, additional flue venting systems are not required. Each unit contains an operating charge of Refrigerant as shipped. Extreme mounting kits are available for slab (BAYEX- MK003A), utility curb (BAYEXMK002B), or curb (BAYEX- MK001A) mountings. The indoor fan motor speed adjustment is provided in the Maintenance section. This guide is organized as follows: Step 1-Inspect Shipment Step 2-Determine Unit Clearances Step 3-Review Location and Recommendation Information Step 4-Unit Installation Step 5-Unit Startup Sequence of Operation Maintenance Step 1 Inspect Shipment 1. Check for damage after the unit is unloaded. Report promptly to the carrier any damage found to the unit. Do not drop the unit. IMPORTANT: To prevent damage to the sides and top of the unit when hoisting, retain the top shipping skid on the unit or use spreader bars as shown on page 20. 2. Check the unit s nameplate to determine if the unit is correct for the intended application. The power supply must be adequate for the unit and all accessories. 3. Check to be sure the refrigerant charge has been retained during shipment. Remove the Compressor access panel to access the 1/4" flare pressure taps. 4. The Flue Hood is included with the unit's literature pack. 5. If this unit is being installed on a curb, verify that the correct curb is provided for the unit. 4YC*3018-036 use model BAYCURB050A. 4YC*3042-060 use model BAYCURB051A. 6. If the unit is being hoisted, accessory kit BAYLIFT002B is recommended. It includes a kit of four (4) lifting lugs and instructions. NOTE: If practical, install any internal accessories to the unit at the shop. Page 3

Step 2 Determine Unit Clearances Figures 1 through 12 show the unit critical dimensions. Figures 1 through 6 show the 4YCC3 clearances and Figures 7 through 12 show the 4YCX3 clearances. NOTE: The view labeled "Bottom Side" represents the base as viewed looking up from underneath the unit. Page 4 Figure 1. 4YCC3018 through 4YCC3036 (1 of 3)

Figure 2. 4YCC3018 through 4YCC3036 (2 of 3) Page 5

Page 6 Figure 3. 4YCC3018 through 4YCC3036 (3 of 3)

NOTE: The view labeled "Bottom Side" represents the base as viewed looking up from underneath the unit. Figure 4. 4YCC3042 through 4YCC3060 (1 of 3) Page 7

Page 8 Figure 5. 4YCC3042 through 4YCC3060 (2 of 3)

Figure 6. 4YCC3042 through 4YCC3060 (3 of 3) Page 9

NOTE: The view labeled "Bottom Side" represents the base as viewed looking up from underneath the unit. Page 10 Figure 7. 4YCX3018 through 4YCX3036 (1 of 3)

Figure 8. 4YCX3018 through 4YCX3036 (2 of 3) Page 11

Page 12 Figure 9. 4YCX3018 through 4YCX3036 (3 of 3)

NOTE: The view labeled "Bottom Side" represents the base as viewed looking up from underneath the unit. Figure 10. 4YCX3042 through 4YCX3060 (1 of 3) Page 13

Page 14 Figure 11. 4YCX3042 through 4YCX3060 (2 of 3)

Figure 12. 4YCX3042 through 4YCX3060 (3 of 3) Page 15

Step 3 Review Location and Recommendation Information NOTE: The unit is shipped for horizontal installation. NOTE: During heating operation, avoid supply air below 80 degrees F or return air below 50 degrees F to prevent flue gas condensation. Horizontal Airflow Units 1. Location of the unit must allow service clearance around it to ensure adequate serviceability, maximum capacity, and peak operating efficiency. 2. These units are designed for outdoor installation. They may be installed directly on a slab, wood flooring, or on Class A, B, or C roof covering material. The discharge air from the condenser fans must be unrestricted for a minimum of 3 feet above the unit. 3. The louvers above and below the flue hood in the side panel must have adequate clearance around the air opening into the combustion area. See Figure 2 on page 5 or Figure 4 on page 7. 4. Examine all flue product-carrying areas of the furnace, its vent system, and the main burner for safe operation. IMPORTANT: A minimum 0 clearance to combustible material shall be maintained on air outlet duct. 5. Exhaust vents or other sources of contaminated air must not be near the unit s air inlet if outside air is to be introduced as make-up air or a ventilation feature is to be used. Contamination from exhaust vents or chimneys may also foul the condenser causing degraded performance. 6. Check the handling facilities to ensure the safety of personnel and the unit(s). 7. The unit must be mounted level for proper drainage of water through the drain holes in the base pan. 8. The unit should not be exposed to direct roof water runoff. 9. Flexible duct connectors must be of a flame retardant material. All duct work outside of the structure must be insulated and weatherproofed in accordance with local codes. 10. Holes through exterior walls or roof must be sealed in accordance with local codes. 11. All fabricated outdoor ducts should be as short as possible. Clearances 1. The recommended clearances for single-unit installations are illustrated in Figures 1 to 12, pages 4-15. 2. Any reduction of the unit clearances indicated in these figures may result in condenser coil starvation or the recirculation of warm condenser air. Actual clearances, which appear to be inadequate should be reviewed with a local engineer. 3. See the unit s nameplate for the absolute minimum clearance between the unit and any combustible surfaces. Down Airflow Units 1. Location of the unit must allow service clearance around it to ensure adequate serviceability, maximum capacity, and peak operating efficiency. 2. Refer to the Installation section for instruction on converting the supply and return airflow covers to down airflow. 3. The field assembled Roof Mounting Curb (BAYCURB050A or BAYCURB051A) or a field fabricated curb should be in place before the unit is hoisted to the roof top. The Roof Mounting Curb (frame) must be installed on a flat, level section of the roof (maximum of 1/4" per foot pitch) and provide a level mounting surface for the unit. Also, be sure to provide sufficient height above the roof to prevent water from entering the unit. 4. Be sure the mounting curb spans structural members (trusses) of the roof, thereby providing sufficient support for the weight of the unit, the curb, the duct(s), and any factory or field installed accessories. 5. The unit must be mounted level for proper drainage of water through the drain holes in the base pan. 6. Be sure the hole in the structure for the ducts is large enough to accommodate the fabricated ducts and the insulation surrounding them. Flexible duct connectors must be of a flame retardant material. All duct work outside of the structure must be insulated and weatherproofed in accordance with local codes. 7. Holes through exterior walls or roof must be sealed in accordance with local codes. 8. These units are designed for outdoor installation. They may be installed directly on a slab, wood flooring, or on Class A, B, or C roof covering material. The discharge air from the condenser fans must be unrestricted for a minimum of 3 feet above the unit. 9. The louvers above and below the flue hood in the side panel must have adequate clearance around the air opening into the combustion area. 10. Examine all flue product-carrying areas of the furnace, its vent system, and the main burner for safe operation. IMPORTANT: A minimum 0 clearance to combustible material shall be maintained on air outlet duct. 11. Exhaust vents or other sources of contaminated air should not be near the unit s air inlet if outside air is to be introduced as make-up air or a ventilation feature is to be used. Contamination from exhaust vents or chimneys may also foul the condenser causing degraded performance. 12. Check the handling facilities to ensure the safety of personnel and the unit(s). Clearances 1. The recommended clearances for single-unit installations are illustrated in Figures 1 to 12, pages 4-15. 2. Any reduction of the unit clearances indicated in these figures may result in condenser coil starvation or the recirculation of warm condenser air. Actual clearances, which appear to be inadequate should be reviewed with a local engineer. 3. See the unit s nameplate for the absolute minimum clearance between the unit and any combustible surfaces. Page 16