Installation and ZONES: Operation Manual. Model: ON STI-34108

Similar documents
Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

Exit Stopper. STI-6400 Series

Go Smart. Go Wireless.

Exit Stopper. STI-6400 Series

EPO STATION. EPO Station with push to activate, turn to reset button complete with a clear cover to help

Protective Cabinet STI-7534, STI-7535 and STI-7535AED

READ ME FIRST DIY WIRELESS ALERT. Driveway Alert Kit. Instruction Manual

Installer Guide smart connect

READ ME FIRST DIY WIRELESS ALERT. Gate Alert Kit. Instruction Manual

Home Doorway Alert Kit

Installer Guide smart connect

Addendum for STI-6406 with Dual Access Control

External Wireless Sounder

WM3000 WIRELESS MODULES

READ ME FIRST DIY WIRELESS ALERT. Add-on Alert Sensor. For Swann Wireless Alert systems. Instruction Manual

Long Range Radio Alarm Transmitter

Wireless Driveway and Intruder Alert

1126 Series Ceiling Mount PIR Motion Detector

NetworX NX-548E Receiver Installation Instructions

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216)

Wireless External Alarm

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

Installation Instructions

Long Range Radio Alarm Transmitter

WatchDog Wireless Crop Monitor Operation Manual

1125 PIR Motion Detector

INSTRUCTION MANUAL Z-WAVE DIMMER 12387

FEATURES AND SPECIFICATIONS

BBQ THERMOMETER DESCRIPTION OF PARTS. MODEL NO.: AW129/AWR129 Instruction Manual

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions

WIRELESS MULTI-ZONE DIGITAL THERMOMETER WITH RADIO CONTROLLED CLOCK. Model No (SF Version) Instruction Manual

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

RF2352A, HC2351AC (Discontinued), HC2352AC

INSTRUCTIONS FOR. Wireless Refrigerator Freezer Thermometer (#10378)

Getting Started with

Responder IV Wireless Bed Interface User s Guide

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

RONDISH DoorWatcher EASY INSTALL STRIP DOOR MONITOR

WIRELESS TEMPERATURE & HUMIDITY STATION INSTRUCTION MANUAL

EW 40 Wireless Fan Control

hc3 OWNER S MANUAL OMHC3US2016/07E

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

Room Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.

9000P Wireless Alarm Owner s Manual

Campers Alert TM Portable System Hunters Alert TM Portable System

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

Getting Started with

Thermometer model 02059

Wireless Home Appliance Timer Remote Control Kit

IDP-Zone-6 Six Zone Interface Module

Zigbee Smoke Sensor PSG03

HSD-200Z Z-Wave Motion Sensor

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

Digital Thermometer with Ice Alert and Clock

ENFORCER OWNER'S MANUAL. SLI 840 / SLI 840C (315 MHz) SLI / SLI 840C-4 ( MHz) Remote Controlled Keyless Entry System with Alarm

SC-6 Six Supervised Control Module

Wireless Weather Station. Table of Contents

Honeywell Temperature & Humidity Sensor with LCD

Table of Contents. What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide With Ring, you re Always home.

Wireless Weather Station

Control/Communicator Installation Manual

Model:T83646v2 Quick Setup Guide DC: WIRELESS WEATHER STATION

Badge Reader BR Installation Guidelines. Product Summary

CDMAEZ. CDMA Universal Alarm Communicator INSTALLATION & USER S GUIDE

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual

888 TWO WAY CAR ALARM SYSTEM USER S MANUAL

Weather Light Model: BAR210 / BAR210U / BAR210A USER MANUAL. EU-Declaration of Conformity...7 FCC Statement...7 Declaration of Conformity...

Ambient Weather WS-091-C Three Channel Display Wireless Thermometer (Console Only) User Manual

I NTEGRATED S ENSOR S UITE WITH F AN-ASPIRATED R ADIATION SHIELD ADDENDUM, REV B. For Vantage Pro and Vantage Pro Plus

Embedded Door Sensor. User's Manual. Model SS881ZB. For other language versions, please visit:

AdvisorOne Quick Operation Guide

Driveway Alarm INSTALLATION MANUAL.

Ambient Weather WS Channel Wireless Thermometer with Min/Max Display User Manual

Ambient Weather WS-16 8-Channel Wireless Thermometer with Min/Max Display User Manual

Digital Refrigerator/Freezer Thermometer model 00986

WIRELESS COLOR WEATHER STATION

Voice Module Installation Guide. For use with ProSYS 16, ProSYS 40, ProSYS 128

PRODUCT DIAGRAM PACKAGE CONTENTS

838 CAR ALARM SYSTEM USER S MANUAL

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Home & Yard Alert Long Range System Home & Yard Alert Extended Long Range System

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions

Model: T83653v2 Instruction manual DC: WIRELESS COLOR FORECAST STATION Mold Risk for Forecast Station & Indoor Remote Sensor Location

IMPORTANT SAFETY INSTRUCTIONS

Wireless ShatterPro Acoustic Sensor Installation Instructions

180 Degree Ceiling Mounted Occupancy Sensors

3226 Trunk Port FXO Doorphone

Pet Immune SAW PIR Motion Sensor

CAUTIONS ON INSTALLATION

English. FCC declaration. Electro Magnetic Compatibility (EMC) Warning. This device complies with part 15 of the FCC rules.

IN-OUT Thermometer with Cable Free Sensor and Clock

Ambient Weather RC-8365 ClearView Radio Controlled Projection Clock with Indoor and Outdoor Temperature User Manual

CR193-RG70E2(2)BGEU

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

WIRELESS COLOR WEATHER STATION

WIRELESS WEATHER STATION

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

Atomic Digital Wall Clock

WIRELESS COLOR FORECAST STATION

Transcription:

N.O. COM N.C. + 12 V - IN + 12 V - OUT 500 ma 300 ma PLUG IN ADAPTER 12 V 500mA Trigger Output 12 V 75mA N.O. COM N.C. + 12 V - IN + 12 V - OUT 500 ma 300 ma PLUG IN ADAPTER 12 V 500mA Trigger Output 12 V 75mA Installation and ZONES: Operation Manual LEFT BUTTON CALL STI 8-Channel RIGHT BUTTON RESTORE NO ZONE: Model: ON STI-34108 and OFF BUTTONS Thank you for purchasing this fine product. Your satisfaction is very important to us. Please read this manual carefully to get the most from your new product. HOW THE PRODUCT WORKS STI offers multiple wireless products designed to alert you of several different conditions. The STI 8-CHANNEL RECEIVER is a 433 MHz radio signal receiver that allows you to monitor up to 8 different STI devices at a single, convenient location. When placed in enroll mode, it allows you to select 1 of 8 different zones that will represent your STI device(s) best, and enrolls it when the monitor detects the STI device s wireless signal. The STI wireless device family uses a system that also ensures other devices (not from STI) are not enrolled or detected. There are no concerns of accidental enrollment, alerts or crosstalk. The RECEIVER allows you to choose which devices shall have a latching memory condition, when selected during enrollment. It also allows you to select turning on a siren, sounding a chime, triggering a normally open or normally closed switch or turning on an external 12 VDC output. The STI 8-CHANNEL RECEIVER also acts as a console repeater when paired with other STI 8-CHANNEL RECEIVERS to receive wireless transmissions in up to 4 other areas over long distances or around disruptive terrain. BEFORE YOU START Refer to this drawing to become familiar with all the parts. ANTENNAS PUSH BUTTON DIPSWITCH FUNCTIONS SWITCHES 1-8 PIEZO WIRE ROUTE OPTION 1 ZONE LEDs COVER SCREW FCC ID: TXL34108 MODEL #34108 IC: 6335A-34108 EMBOSSED INPUT AND OUTPUTS SAFETY TECHNOLOGY INTERNATIONAL WATERFORD, MI U.S.A. REDDITCH, WORCESTERSHIRE UK TRIGGERED OUTPUT PLUG 12V, 75mA PLUG IN ADAPTER 12V, 500mA SURFACE FEET (x4) (WALL MOUNTING HOLES) WIRE ROUTE OPTION 1 EMBOSSED INPUT AND OUTPUTS FORM C SWITCH OUTPUTS WIRE ROUTE OPTION 2 FORM SWITCH OUTPU 12V TERMINA 12V INPUTS TERMINALS 500mA 12V OUTPUTS TERMINALS 300mA FCC ID: TXL34108 MODEL #34108 IC: 6335A-34108 SAFETY TECHNOLOGY INTERNATIONAL WATERFORD, MI U.S.A. REDDITCH, WORCESTERSHIRE UK EMBOSSED INPUT AND OUTPUTS 1 TRIGGERED OUTPUT PLUG 12V, 75mA PLUG IN ADAPTER 12V, 500mA SURFACE FEET (x4) (WALL MOUNTING HOLES)

SIREN SW4 SW5 TIME MIRROR # OFF OFF DISABLED 1 ON OFF 30 SEC 2 OFF ON 180 SEC 3 ON ON ON CONT 4 INSTALLATION GUIDE Surface Installation 1. Ensure mounting screws are removed. 2. Insert rubber feet (provided) into holes on bottom cover. 3. Route wires under the product. Wall Mounted Installation 1. Ensure rubber feet are removed. 2. Remove front cover screw. 3. Remove cover (be careful not to lose push button). 4. Mark mounting holes on wall using bottom cover as template. 5. Drill holes with 3/16 drill bit. 6. Insert wall anchors (provided). 7. Insert power cord and wires and route on the back. 8. Insert mounting screws (provided) into plastic washers (provided). 9. Insert mounting screws into PCB holes through back of cover. 10. Insert mounting screws into wall anchors and tighten. 11. Press fit push button onto the push button switch on the circuit board. 12. Insert top cover tabs into bottom cover slots. 13. Carefully close top cover ensuring the push button inserts into cover hole and antennas rest in the side cover grooves. 14. Insert front cover screw and tighten. 15. Plug in AC adaptor. 1 - MIRROR MASTER OFF/ON 2 - NORMAL/ENROLL 3 - AUTO RESTORE/LATCH 4 - SIREN TIME/MIRROR# 5 - SIREN TIME/MIRROR# 6 - CHIME OFF/ON 7 - NORMAL/DELETE 8 - MIRROR SLAVE OFF/ON If using for the first time or for enrollment adjustments, follow Zone Enrolling instructions. Otherwise, STI 8-CHANNEL RECEIVER should be fully functional. 19018 ANCHOR (4) PROVIDED MARK AND DRILL 3/16 DIAMETER HOLES (4) PLACES PUSH BUTTON SWITCH PUSH BUTTON 19081 FRONT COVER SCREW 19108 NYLON WASHER (4) PROVIDED 19039 SCREW (4) PROVIDED 2

COMPONENT DESCRIPTIONS (Top Side) Switches (1-8) - For reference, information is also written on the RECEIVER case (located under Zone ID list). 1 - MIRROR MASTER OFF/ON 2 - NORMAL/ENROLL 3 - AUTO RESTORE/LATCH 4 - SIREN TIME/MIRROR# 5 - SIREN TIME/MIRROR# 6 - CHIME OFF/ON 7 - NORMAL/DELETE 8 - MIRROR SLAVE OFF/ON SIREN SW4 SW5 TIME MIRROR # OFF OFF DISABLED 1 ON OFF 30 SEC 2 OFF ON 180 SEC 3 ON ON ON CONT 4 Switch # DESCRIPTION ON (Switch UP) OFF (Switch DOWN) SW1 MASTER RECEIVER SETTING ENABLED DISABLED (Only active when SW8 = ON) Switch on only for Mirror Master Switch off if not Mirror Master SW2 ENROLL DEVICES ENABLED DISABLED LED for zone number waiting to enroll blinks. Normal Operation Button used to change zone to be enrolled. SW3 ALARM LATCHING ENABLED DISABLED (Only active while LED turns on when triggered LED turns on when triggered SENSOR is being enrolled) Button press turns off siren LED flashes when restored LED turns off when restored Second button press turns off LED flashing SW4 RECEIVER # / SIREN TIME RECEIVER# (when SW8 = ON) SIREN TIME (when SW8 = OFF) and Note: Siren can turn off upon button press. SW5 ON = 1 (SW4)(SW5) 00 = Mirror #1 (SW4)(SW5) 00 = 0 Second (Silent) OFF = 0 10 = Mirror #2 10 = 30 Seconds 01 = Mirror #3 01 = 180 Seconds 11 = Mirror #4 11 = Continuously ON SW6 RECEIVER CHIME ENABLED DISABLED Chime sounds a double beep Chime does not sound when when device is triggered. device is triggered. SW7 DELETE DEVICES ENABLED DISABLED All LEDs turn red. LED blinks for zone to be Normal Operation deleted. Hold button for 5 seconds to delete. Hold button another 5 seconds to delete all. SW8 MIRROR MODE ENABLED DISABLED Enables Mirror Mode. Enables SW1. Disables Mirror Mode. Disables SW1. SW4/5 indicate RECEIVER#. SW4/5 indicate ALARM TIME. Turns on RECEIVER# (SW4/5) transmissions. Turns off mirrored transmissions. Push Button - Selects zone to enroll or delete, acknowledge latched alert (resets LED to GREEN), silences alarm. LEDs (1-8) - Each enrolled SENSOR or mirrored RECEIVER has an LED that indicates the current state of that zone from the top LED (Zone 1) down to the bottom LED (Zone 8). The zone states, in order of precedence, are: LED RED = zone alarm LED RED (flashing) = zone latched (zone was in alarm and returned to normal) LED AMBER = SENSOR trouble (battery or SENSOR tamper trouble detected) LED GREEN = zone normal LED off = zone not enrolled Sounder - Audio feedback for siren, chime/ beeps, zone enrollment and deletion. 3

COMPONENT DESCRIPTIONS (Bottom Side) Adapter Plug Input - Input connector 12VDC, 500mA, center positive adapter (provided). Triggered Output Plug (75mA) - 12VDC output connector. Activates with 12VDC, 75mA for 3 seconds when any zone is triggered. Designed for use with STI Lamp Controller (STI-30104 sold separately). Form C Switch Outputs (Dry Contacts) 30VDC, 1A Resistive N.O. - Normally open circuit to COM terminal. Closed to COM when alarm is triggered. COM - Common return between N.O. or N.C. N.C. - Normally closed circuit to COM terminal. Open to COM when alarm is triggered. When any zone has an alert signal received and the LED changes to continuous RED, a short circuit is made between the NO and COM, and an open circuit is made between NC and COM. As soon as ALL zones are not in alert mode and the LED is no longer continuous RED, an open circuit is made between NO and COM, and a short circuit is made between NC and COM. 12VDC Input (500mA) +12VDC - Positive voltage input. Power input circuit rated to 500mA current. -12VDC - Negative voltage input. The 12VDC input terminals allow the RECEIVER to be powered from an external 12VDC, 500mA rated power source. 12VDC Output (300mA) +12VDC - Positive output voltage. 300mA maximum output current. -12VDC - Negative output voltage. A continuous 12VDC output is produced only while sounder is activated. The 12VDC output terminals will turn on at the same time as the onboard sounder in siren mode or chime mode. NORMAL OPERATION The RECEIVER receives 433 MHz radio signals from numerous STI sensors enrolled to the RECEIVER. It provides feedback in the form of LED colors, onboard sounder annunciation, onboard sounder siren, switched on or off output terminals (Form C contacts), a 3 second 12 VDC @ 75mA max. output on the triggered output plug and 12 VDC output terminals powered at the same time as the onboard sounder. LED Operation The LED status with higher importance is emitted by the LED. The LED importance is as follows (highest to lowest): Red LED - Zone enrolled, Alert status Flashing Red LED - Zone enrolled, Latched and Non-Triggered status Amber LED - Zone enrolled, Tamper Alert and Non-Triggered status Green LED - Zone enrolled, Normal and Non-Triggered status LED OFF - Zone not enrolled Onboard Sounder Operation Siren Mode SW4 and SW5 (settings) The onboard speaker gives a 4 KHz @ 90dB sound for the SIREN TIME set by SW4 and SW5 when any zone s alert signal is received (see Component Descriptions for siren times). NOTE: Chime/Beep mode must be turned off, (SW6 OFF), for the siren mode to activate. Chime/Beep Mode (SW6 ON) The onboard speaker gives a double beep when any zone s alert signal is received. Chime/Beep mode overrides the siren mode. Sensor Operation A SENSOR sends a 433 MHz radio signal to the RECEIVER that will indicate one or more of the following: Alert triggered; restored to normal; sensor tampering; low battery; lost signal. 4

Low Battery / Tamper Detection / Out of Range SENSOR Alerts If the battery is too weak, something has triggered a tamper alert signal from the SENSOR, or the SENSOR has been out of range between 12-24 hours, the zone LED will light AMBER to alert a need for attention to that device. ZONE ENROLLING AND DELETING PROCEDURES The STI 8-Channel is designed to receive ONLY wireless signals from products in the STI Alert Series (see back of the installation instructions). The RECEIVER allows you to enroll up to 8 devices into zones 1 thru 8. The RECEIVER will enroll from different SENSORS directly or by enrolling other mirrored RECEIVERS. The RECEIVER also enrolls up to eight keyfobs. When ENROLL mode is enabled (SW2 ON), the LEDs for any currently enrolled zones will turn RED to indicate these zones are not available. The LED will flash GREEN to indicate the available zone to be enrolled. Press the push button to change to a different zone to be enrolled. The next available zone will have the flashing GREEN LED. The RECEIVER will not allow enrollment into an occupied zone. The RECEIVER will not allow the same device to be enrolled into more than one zone. The RECEIVER will not enter ENROLL mode while it is in DELETE mode (i.e. DIP SW7 ON). Zone Latching Latching lets you know a zone alert was previously triggered but the alert has also been cleared. When a zone is in the latched status, the zone LED will flash RED. For example, when a door SENSOR has been opened and closed, the zone LED will flash RED to indicate the door was opened previously, but is no longer opened. The latching is released when the user presses the push button to indicate acknowledgement of the alert. When the latched status is released, the zone LED will change back to continuous GREEN. If the zone has another alert before the latched status is released, the LED will change to continuous RED in the alert state, and then back to flashing when the alert is cleared. A zone will have latching when SW3 is (ON) at the time of enrollment. If zone latching is not selected at the time of enrollment (SW3 OFF), the zone LED will change from continuous RED back to continuous GREEN when the alert has been cleared. Enrolling Sensors into Zones 1. Check that the module is not in DELETE mode (SW7 OFF). 2. If the zone should have latching set (SW3 ON). 3. Enable ENROLL mode set (SW2 ON). 4. Check that the zone flashing GREEN is correct, and note the zone(s) with RED LEDs. 5. Change the status of the SENSOR to be enrolled by triggering an alert on the SENSOR and return it to the non-triggered state (if done manually). 6. The RECEIVER will give a double beep and the zone LED will change to continuous RED. 7. Repeat steps 2-6 to enroll another SENSOR. 8. To exit ENROLL mode set (SW2 OFF). Sensor Installation Tip When first enrolling a SENSOR, set the latching on (SW3 ON), and bring the SENSOR to the RECEIVER location to enroll it before mounting the SENSOR. Then, mount the SENSOR at its intended location and trigger an alert on the SENSOR. Check the zone on the RECEIVER to see if it is continuous RED or flashing RED, which means it received the SENSOR S signal. Then, if latching is not desired, delete that zone (see Deleting Single Zones) and enroll the SENSOR again without latching (SW3 OFF), from the mounted location. 5

Keyfob Operation An STI Keyfob can be used to remotely turn off and on the LEDs, sounder, and outputs on the STI 8-Channel and also act as a CALL or MANUAL ALERT button. While the STI 8-Channel ZONES: LEFT BUTTON is turned off, it will continue to monitor the sensor signals. CALL To use an STI keyfob, you can separately enroll the Left/Right buttons and ON/OFF buttons to the RIGHT BUTTON RESTORE receiver. To use a single STI keyfob with a Master + Mirror System, enroll the keyfob to NO ZONE: ON and OFF BUTTONS each receiver to be used in the system before adding the Mirrored receivers to the system. To use multiple keyfobs to independently control each receiver, enroll each keyfob to its respective receiver before adding the Mirrored receivers to the system. Enrolling Keyfob On/Off Buttons Keyfob ON/OFF buttons do not enroll into zones. The keyfob ON/OFF buttons will turn on and off all 8-Channel receiver outputs. Cycling these buttons remotely activates the push button. 1. Check that the module is not in DELETE mode (SW7 OFF). 2. Enable ENROLL mode set (SW2 ON). 3. Press either the ON or OFF button on the keyfob. 4. The RECEIVER will give a double beep. ON/OFF keyfob buttons will not be assigned to a zone LED. 5. Repeat steps 2-4 to enroll another keyfob. 6. To exit ENROLL mode set (SW2 OFF). NOTE: The RECEIVER will only operate with 8 keyfob Left/Right buttons enrolled into zones and 8 keyfob ON/OFF buttons enrolled into memory. If a ninth keyfob s ON/OFF button is enrolled, the keyfob s ON/OFF buttons enrolled first will be deleted. Enrolling Keyfob LEFT/RIGHT Buttons Keyfob LEFT/RIGHT buttons enroll into a zone. The keyfob LEFT button is a CALL or MANUAL ALERT button and the RIGHT button is a RESTORE. Follow the same steps for Enrolling Sensors into Zones and Deleting Single Zones for the Keyfob LEFT/ RIGHT buttons. Mirrored Operation The LEDs, the sounder, the siren time and the 12VDC output activation will duplicate the sensor settings enrolled on the master RECEIVER. If a sensor is enrolled to a mirrored RECEIVER instead of the master, a transmission from the master RECEIVER will override the mirrored RECEIVER S LED status. To use any STI keyfob with a master + mirror RECEIVER system, enroll keyfob to mirrored RECEIVER before adding the mirrored RECEIVER to a system. Enrolling Mirrored (multiple) s The LEDs, the sounder, the siren time and the 12VDC output activation will duplicate the sensor settings enrolled on the master RECEIVER. If LED latching is desired on the mirrored RECEIVER, this must be selected at the time of the mirrored RECEIVER S enrollment. NOTE: If a SENSOR is enrolled to a mirrored RECEIVER in error (instead of the master), a transmission from the master RECEIVER will override the mirrored RECEIVER S LED status. 1. Check that the module is not in DELETE mode (SW7 OFF). 2. Use SW4 and SW5 to select the mirror number 1-4 if not the master (see Component Descriptions). 3. Enrolling mirrored RECEIVERS is performed in sequential pairs: Pair Column A Column B 1 Master => 1 2 1 => 2 3 2 => 3 4 3 => 4 NOTE: All SENSORS are enrolled only to the master RECEIVER. The mirrored RECEIVERS copy the master RECEIVER S output (except latch settings) sequentially thru RECEIVERS 1-4. 4. Set SW1 and SW8 (ON) on the master RECEIVER. 5. Set SW8 (ON) on each mirrored RECEIVER. 6. Enable ENROLL mode, SW2 (ON), on the two RECEIVERS being paired together. 7. Press and release the Push Button on the Column A RECEIVER (above). The Column B receiver will give a double beep. 8. Press and release the Push Button on the Column B RECEIVER (above). The Column A RECEIVER will give a double beep. NOTE: If Column B RECEIVER was previously enrolled to Column A RECEIVER and was not deleted, the Column A RECEIVER will not double beep, but will work properly. 9. Disable ENROLL mode, SW2 (OFF), on both RECEIVERS. 10. Press and release the Push Button of the Column A RECEIVER (above). The LED s of the Column B RECEIVER will light in the same configuration. NOTE: Keyfobs must be enrolled into each master or mirror RECEIVER where it will be used. 6

Enrolling Sensors into Master + Mirror Systems (with or without latching) When using a master + mirror RECEIVER system, the latching feature is set independently on the master and/or mirror RECEIVERS. Latching on the master and/or mirrored RECEIVERS is only set for a zone at the time the SENSOR is enrolled into the master RECEIVER. You will need to set (SW2 ON) and (SW3 ON or OFF) for each RECEIVER at the time of SENSOR enrollment. 1. Check that each RECEIVER is not in DELETE mode (SW7 OFF). 2. Set desired latching on each system RECEIVER. A RECEIVER set to (SW3 ON) will have latching. The RECEIVER set to (SW3 OFF) will only indicate the zone status. 3. Set each RECEIVER to ENROLL mode, (SW2 ON), that will store the latch setting. 4. Check that the zone flashing GREEN on the master RECEIVER is correct, and note the zone(s) with RED LEDs. 5. Trigger an alert on the SENSOR being enrolled and return it to the restored state (if restore is triggered manually). 6. The RECEIVER will give a double beep and the zone LED will change to continuous RED. 7. Repeat steps 2-6 to enroll another SENSOR. 8. To exit ENROLL mode, set (SW2 OFF) on the master RECEIVER. 9. Set all master and/or mirror RECEIVERS (SW3 OFF). System Examples SINGLE SYSTEM Master Mirror #1 Mirror #2 Mirror #3 Mirror #4 - Last MULTLIPLE SYSTEMS Represents any STI 433 MHz sensor transmitting ONLY to a Master SYSTEM 1 SYSTEM 2 Master Mirror #1 Mirror #2 - Last Mirror #2 - Last Monitors Housed in a Central Office or Location Mirror #1 Master DELETING SINGLE ZONES (Sensors and Keyfobs) 1. Enter DELETE mode (SW7 ON). All enrolled zone LEDs will turn RED. The first zone to be deleted will have the LED flashing RED. 2. Press and release the push button to cycle the flashing LED through the zones until it reaches the zone to be deleted. 3. Press and hold the push button for 5 seconds to delete the zone with the flashing LED. The RECEIVER will give a single beep and the LED will turn off. Release the push button. DELETING ALL ZONES (Sensors, Mirrored s and Keyfobs) You must delete all zones in order to delete keyfobs and/or a mirrored RECEIVER. 1. Enter DELETE mode (SW7 ON). All enrolled zone LEDs will turn RED. The first zone to be deleted will have the LED flashing RED. 2. Press and hold the push button for 5 seconds. The RECEIVER will give a single beep and the flashing LED will turn off. Continue to hold the push button. 3. After the first zone is deleted and while still holding the push button, all other enrolled zones will flash for 5 seconds. The RECEIVER will give a double beep and all of the LEDs will turn off when those zones are deleted. 7

IMPORTANT NOTICE This product has been tested and complies with the specifications for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used according to the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which is found by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna - Increase the separation between the equipment or devices - Connect the equipment to an outlet other than the receiver s - Consult a dealer or an experienced radio/tv technician for assistance Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Changes or modifications not expressly approved by Safety Technology International, Inc. could void your authority to operate this equipment. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. This product meets the applicable Industry Canada technical specifications. Le present materiel est conform aux specifications techniques applicables d Industrie Canada. Model: 34108 FCC ID: TXL34108 IC: 6335A-34108 This device is a wireless receiver intended for home and office use in all EU and EFTA member states. OPTIONAL LAMP CONTROLLER ACCESSORY The Lamp Controller will turn on a lamp any time your STI 8-CHANNEL RECEIVER is triggered. Never come home to a dark house again, and let others think you are home when you aren t. The Lamp Controller works with both the STI-34150 (battery) and the STI-34100 (solar) models. WARNINGS FOR INDOOR USE ONLY. Keep RECEIVER away from water and/or damp areas. When using lamp controller option, use ONLY 200 Watt or less incandescent lamps, and keep lamp away from bed coverings, curtains or other flammable materials as this may present a fire hazard. The lamp controller CANNOT be used with 3-prong grounded plugs. WARRANTY INFORMATION Safety Technology International, Inc. warrants to the original consumer/purchaser that this product shall be free of defects in material and workmanship under normal use and circumstances for a period of one (1) year from the original date of purchase. Electronic warranty form at www.sti-usa.com/wc14. ADDITIONAL WIRELESS ALERT SERIES PRODUCTS STI-34098 Single Channel Slave STI-6200WIR Wireless Fire Extinguisher Theft Stopper STI-34104 4-Channel STI-6200WIR4 Wireless Fire Extinguisher Theft Stopper w/ STI-V34104 4-Channel Voice STI-6400WIR Wireless Exit Stopper Door Alarm STI-34108 8-Channel STI-6400WIR4 Wireless Exit Stopper Door Alarm with STI-34188 8-Zone Relay Board STI-6517A Stopper Station Shield with Sound STI-34101 Solar Powered Driveway Monitor Sensor STI-6517B Stopper Station Shield with Sound and Transmitter STI-34151 Battery Powered Driveway Monitor Sensor STI-30104 Lamp Controller STI-34201 Wireless Mailbox Alert Sensor STI-30105 Extended Antenna STI-34301 Wireless Garage Sentry Sensor STI-34105 Voltamax 12VDC (500mA) Power Supply STI-34401 Wireless Universal Alert Sensor STI-34106 Keyfob STI-34501 Wireless Entry Alert Sensor STI-34109 Repeater STI-34601 Wireless Doorbell Button STI-34701 Indoor Wireless PIR STI-34751 Outdoor Wireless PIR 2306 Airport Rd Waterford, MI 48327 Phone: 248-673-9898 Fax: 248-673-1246 info@sti-usa.com www.sti-usa.com Safety Technology International (Europe) Ltd. Unit 49G Pipers Road Park Farm Industrial Estate Redditch Worcestershire B98 0HU England Tel: 44 (0) 1527 520 999 Fax: 44 (0) 1527 501 999 Freephone: 0800 085 1678 (UK only) E-mail: info@sti-europe.com Web: www.sti-europe.com Inst. Sht. 8-Channel Wireless DEC2012