Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

Similar documents
1 General Description

Honeywell Durafit LED Retrofit Kit

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

MaxLite LED Round Pendant Highbay Series

Innovative Lighting R-Series Overhead LED Conversion Kits

Innovative Lighting R-Series Vertical Refrigeration

Universal Fan and Light Remote Control

Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits

Installation Instructions

MaxLite LED Vapor Tight Linear Fixture

Installation Instructions

Dioluce Products Installation Instructions

Cold Door 2 LED Retrofit Kit Lighting System

LED Flat Panel Retrofit

1 x4 Dimmable LED RetroFits

EMERGENCY POWERHUBB NODE INSTALLATION AND OPERATION GUIDE

Dimmable LED Retrofit Kit

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

MaxLite LED MICRO-T PANEL

Installation Instructions

INSTALLATION INSTRUCTIONS

FV-11VQL6. Thank you for purchasing this Panasonic product Back cover FV-15VQL6

programmable control model installation and setup guide M /11/ Hunter Fan Company

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

Innovative Lighting Smooth Light Recessed Luminaires

LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:

LED IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Please Keep This Manual For Future Reference REV.01

Unpacking Your Fan 2.

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

Installation Manual. Models 99168, 99169, 99170

Cold Deck Canopy and Shelf Lights and Retrofit Kit

BACKUP BATTERY INSTALLATION INSTRUCTIONS

WINDSOR FOREST HIGH SCHOOL HVAC REPLACEMENT ADDENDUM #2 SAVANNAH CHATHAM COUNTY PUBLIC SCHOOL SYSTEM FEBRUARY 18, 2016

SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400

Installation Instructions

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ

Cold Deck FIT. Canopy and Shelf Lights and Retrofit Kit. Installation Guide for General Information. Tools and Accessories Recommended

Optima ZigBee Thermostat

LED RETROFIT SOLUTIONS

SC-6 Six Supervised Control Module

LED Emergency Battery Backup

Installation Instructions

LED IMPORTANT SAFETY INSTRUCTIONS

640 Series Advanced Remote Vehicle Security System

LED RETROFIT CONVERSION KITS

CZ-6A Six Zone Interface Module

52 BERKSHIRE CEILING FAN

LED IMPORTANT SAFETY INSTRUCTIONS

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391

23-IN Electric Logset

Owner s Manual Compact Fluorescent Lunar Aqualight

LED IMPORTANT SAFETY INSTRUCTIONS

PIR Sensor. User s Guide

48 TAYLOR CEILING FAN

Turbo Stick Vac. OWNER S MANUAL Model EP V., 60Hz., 7.5 Amps.

Thermometer model 02059

52 CEILING FAN. Owner s Manual Models #50336, 50337

Owner s Manual. High Output T5 Lunar Aqualight. Aquarium Light Fixture. Featuring: Directional Lunar Blue LEDs

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

Hi-lume 3D Overview. Fluorescent Dimming Ballasts

INSTALLATION MANUAL. PP1 Ozone System Designed for use within pool skimmer

INSTALLATION INSTRUCTIONS WARNINGS AND INSTRUCTIONS FOR LUMINAIRES

nova extreme retrofit High Output T5 Lighting Kit

Bdl60u Fluorescent Emergency Ballast

MaxLite LED High Bay Fixtures

ESRB and ESRN Installation & Safety Instructions

ITEM # SAIL STREAM CEILING FAN MODEL #41695

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

ELECTRIC FIREPLACE OWNER S MANUAL

Caution: To maintain compliance with the RF exposure guidelines, place the unit at least 20cm from nearby persons.

Concert Breeze s Manual

Manual Feed Slot Opening. Wastebin. Credit Card Casters

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

OWNER S MANUAL & WARRANTY

Use and Care Manual. Flammable Material Storage Refrigerator LRBFS06W1HC

Lumination TM Volumetric Retrofit Kit

With Remote Control. English

MaxLite Polygon Linear LED Light

LED IMPORTANT SAFETY INSTRUCTIONS

52 BAYTOWNE CEILING FAN

ARUBA SUN SERIES - LIGHTING SYSTEM USER MANUAL

ITEM # , , PAWTUCKET CEILING FAN MODEL #40958, 40959, 40047

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL

IMPORTANT SAFETY INFORMATION:

MAXLITE RKT LED Retrofit Kit

Installation Instructions Lithonia Lighting Clean Room Troffer. Grid & Sheet Rock Installation, Maintenance

IMPORTANT SAFETY INFORMATION:

Hi-lume 3D Overview. Fluorescent Dimming Ballasts Hi-lume 3D Architectural Dimming

Instruction Manual. AcuRite Atlas Outdoor Device model 06059

2018 Commercial Lighting Retrofit Rebate Program

EcoSystem H-Series Ballasts

OPERATING MANUAL BIRD VERTICAL DISPLAY SYSTEMS

CEILING FAN LIGHT KIT

LIMITED LIFETIME WARRANTY

Transcription:

LED Tube Lamp (Linear Fluorescent Replacement) Retrofit Installation Instructions The product package includes the following components: 1. Integral LED Lamp (1 unit) 2. Fixture Warning Label (1 - self-adhesive) 3. Installation Instructions (1-6 pages) IMPORTANT SAFETY INSTRUCTIONS AND WARNINGS THIS PRODUCT SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST U.L. SAFETY, NEC AND/OR LOCAL AUTHORITY HAVING JURISDICTION. INSTALLATION SHALL BE PERFORMED BY A QUALIFIED ELECTRICIAN UNDERSTANDING THE CONSTRUCTION AND OPERATION OF THIS PRODUCT AND THE ELECTRICAL REQUIREMENTS INVOLVED. Risk of fire or electric shock: LED Retrofit Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit installation. Do not leave any other open holes in an enclosure of wiring or electrical components. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. Do not install in a raceway or a luminaire marked for through branch wiring. Risk of fire or electric shock: Use only on 120-277 VAC, 50/60Hz circuits. Installer shall verify operating voltage at the luminaries prior to installation. Risk of fire or electric shock: Install this kit only in the luminaires that have the construction features and dimensions shown below. 54105111 54105131 54105141 54130111 54130131 54130141 54108111 54108131 54108141 54108161 23.8'' x 5.71'' x 2.7'' 23.8'' x 11.34'' x 2.7'' 23.8'' x 16.54'' x 2.7'' 23.8'' x 20.7'' x 2.7'' 35.8'' x 5.71'' x 2.7'' 35.8'' x 11.34'' x 2.7'' 35.8'' x 16.54'' x 2.7'' 35.8'' x 20.7'' x 2.7'' 47.2" x 5.71" x 2.7" 47.2" x 11.34" x 2.7" 47.2" x 16.54" x 2.7" 47.2" x 20.7" x 2.7" Page 1 of 6

Suitable for damp or dry locations when used with UL Listed Type IC or Non-IC, recess mounted or surface mounted luminaires and suitable for use in totally enclosed luminaires. Risk of fire or electric shock: To prevent wiring damage or abrasion, protect wiring from exposed edges of sheet metal or other sharp objects that may be present in the fixture. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. To avoid potential fire or shock hazard, do not use this retrofit kit in luminaires employing shunted bi-pin lamp holders. Note: Shunted lamp holders are found only in fluorescent luminaires with Instant-Start ballasts. Instant-start ballasts can be identified by the words "Instant Start" or "I.S." marked on the ballast. For more information, contact ETi Solid State Lighting at (855) 384-7754 or www.etiled.us. Note: If the end user wants to use this retrofit kit in luminaires employing shunted bi-pin lamp holders, a qualified electrician must replace all shunted bi-pin lamp holders with bi-pin lamp holders. Installers should not disconnect existing wires from lamp holder terminals to make new connections at lamp holder terminals. Instead, installers should cut existing lamp holder leads away from the lamp holder and make new electrical connections to lamp holder lead wires by employing applicable connectors. Do not make modifications to or alter fixture housing, ballast enclosure or electrical components other than those required for proper installation. THIS RETROFIT ASSEMBLY IS AN APPROVED COMPONENT OF A LINEAR FLUORESCENT LUMINAIRE KIT WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR LOCAL AUTHORITIES HAVING JURISDICTION. Non-shunted fluorescent lamp holders within fixture shall be rewired to line voltage and will no longer operate the original fluorescent lamp. DO NOT USE WITH DIMMERS. THIS DEVICE IS NOT INTENDED FOR USE WITH EMERGENCY LIGHTING (BATTERY TYPE) SYSTEMS FOR FLUORESCENT LIGHTING PRODUCTS. 1. Electrical Characteristics (Typical value): Length 2ft (54105111, 54105131, 54105141) Voltage AC (V) 120-277 Current AC (ma) 150 Power (W) 9 PFC >0.9 Rated Frequency (Hz) 50/60 Page 2 of 6

Length 3ft (54130111, 54130131, 54130141) Voltage AC (V) 120-277 Current AC (ma) 300 Power (W) 14 PFC >0.9 Rated Frequency (Hz) 50/60 Length 4ft (54108111, 54108131, 54108141, 54108161, 54104431, 54104441) Voltage AC (V) 120-277 Current AC (ma) 350 Power (W) 18 PFC >0.9 Rated Frequency (Hz) 50/60 2. Installation DANGER -RISK OF ELECTRIC SHOCK-DISCONNECT POWER TO LIGHT FIXTURE BEFORE INSTALLATION OR REPLACEMENT. To replace fluorescent tube lamp with LED tube lamp, the wiring must be installed according to these instructions to ensure a complete and safe installation of the LED tube lamp. Note: LED Tube Lamp requires single end power only; wiring to one side of the fixture is sufficient. Ensure lamp end labeled POWER THIS END is installed to the live circuit. Page 3 of 6

1. Turn off the power to the light fixture at the breaker panel before installation or replacement. 2. If retrofitting an enclosed fixture open the diffuser from the light fixture. 3. Remove existing fluorescent lamps. Please dispose or recycle these items properly in accordance with local requirements as they contain mercury. 4. Open the wiring cover to expose the fluorescent ballast. Inductive ballast type Electronic ballast type Ballast with 2 lamps Ballast with 3 lamps 5. Cut the wires shown as the diagram below. Optional: Remove ballast and starter and dispose or recycle in accordance with local requirements. Inductive ballast type Electronic ballast type Page 4 of 6

Ballast with 2 lamps Ballast with 3 lamps 6. Make the new wire connection for new branch circuit wiring required and shown as in diagram below. The labeled end of LED Tube Lamp is the live, input powered end. The opposite end is electrically isolated and serves as means of mechanical support only. 7. Reinstall the ballast cover over the wiring channel. 8. IMPORTANT: Install the fixture warning label provided in a visible location after the LED Tube Lamp is installed, possibly on the wiring channel cover. Page 5 of 6

Imported by ETi Solid State Lighting, Inc. 26650 Renaissance PKWY, STE6 Cleveland, OH 44128 Made in China LIMITED WARRANTY: This product is warranted for a period of 5 years from the date or original purchase against defects in materials and workmanship. If this product should fail to operate due to defects in material or workmanship, simply call 1-216-468-0232 within 60 months of purchase. This product will be repaired or replaced, at ETi s option. This warranty is expressly limited to repair or replacement of product and liability for direct, incidental, or consequential damages is hereby expressly excluded. Some states do not allow exclusions of direct, incidental or consequential damages so the above limitation of exclusion may not apply to you. This warranty gives the consumer specific legal rights, which vary from state to state. WARRANTY IS VOID IF PRODUCT IS NOT USED FOR THE PURPOSE WHICH THIS PRODUCT IS MANUFACTURED. Page 6 of 6