ATTACHMENT 2 Kim ing SCALE: 1"=2000' PROPERTY INFORMATION: (FOR SUBJECT PARCELS) FCP NUMBERS SPECIMAN (30" & GRATER) TREE REPLACEMENT MITIGATION REQUIREMENTS LEGEND DEVELOPER'S NAME: CONTACT PERSON OR OWNER: ADDRESS: PHONE AND EMAIL: SIGNATURE: Expiration NRI/FSD NUMBER FC1.1 GENERAL NOTES
LEGEND Rockville, MD 20852 7939 Norfolk Avenue, Suite 200, Bethesda, MD 20814 Kim ing Pine & Swallow DEVELOPER'S NAME: CONTACT PERSON OR OWNER: ADDRESS: PHONE AND EMAIL: SIGNATURE: Expiration FC1.2
Kim ing LEGEND MATCH LINE - SEE FC1.4 DEVELOPER'S NAME: CONTACT PERSON OR OWNER: ADDRESS: PHONE AND EMAIL: SIGNATURE: Expiration MATCH LINE - SEE FC1. 5 MATERIALS LEGEND FC1.3
7939 Norfolk Avenue, Suite 200, Bethesda, MD 20814 Kim ing Pine & Swallow LEGEND Rockville, MD 20852 DEVELOPER'S NAME: CONTACT PERSON OR OWNER: ADDRESS: PHONE AND EMAIL: SIGNATURE: Expiration FC1.4
LEGEND Rockville, MD 20852 Kim ing 7939 Norfolk Avenue, Suite 200, Bethesda, MD 20814 Pine & Swallow MATERIALS LEGEND DEVELOPER'S NAME: CONTACT PERSON OR OWNER: ADDRESS: PHONE AND EMAIL: SIGNATURE: Expiration 3/19/2015 FC1.5
SEQUENCE OF CONSTRUCTION TRUNK 2" MIN. CLOSED CELL FOAM ROPE OR STAP MAIN TRUNK OF TREE INSTALL A 2"x4" MIN. BOARD WITH FOAM TIED ON WORK SIDE OF TREE MACHINERY AND STOCKPILING PROHIBITED EXTEND STONE 6" BEYOND PAVING NATURAL GROUND 6" KBI FLEXI-PAVE HD2000 FLEXIBLE POROUS PAVING OR APPROVED EQUAL SEE SITE PLAN FOR WIDTH Kim ing MIN. 12 FIBER/NYLON ROPE OR STAPS. MIN. 3 PLACES OR AS DIRECTED BY THE ARBORIST 2" NOMINAL PAVING THICKNESS 6" COMPACTED #57 STONE BACKFILLED PLANTING SOIL GEOGRID GEOTEXTILE FABRIC EXISTING UNDISTURBED SOIL STEEL "T" BAR OR "U" CHANNEL POST 6" ATTACH THE SIGN TO POST WITH HEAVY-DUTY ZIPTIES TYP. 3 PLACES EXTEND GEOTEXTILE FABRIC 6" PAST THE TOP OF THE WOOD MULCH AND ATTACH TO THE WELDED WIRE MESH FENCE EVERY 24" O.C. TYP. 14 GAUGE 2" X 4" WELDED WIRE FENCE 1/3 HEIGHT OF STAKE ROOT PROTECTION ZONE AS SHOWN ON PLANS MIN. 15" Machinery, dumping or storage any materials prohibited. Violators are subject to fines as imposed by the Maryland Forest Conservation Act 1991 INSTALL ANCHOR POSTS TO A DEPTH OF NO LESS THAN 1/3 OF THE TOTAL HEIGHT OF POST UNDISTURBED GROUND 8 mm GEOTEXTILE INSTALLED BETWEEN THE UNDISTURBED GROUND AND MULCH 5' TALL HARD WOOD STAKE Do not work or place materials beyond this tree protection fence 12" MIN. THICK LAYER OF WOOD CHIP MULCH REPLENISHED AS NEEDED DURING THE CONSTRUCTION PERIOD 20 " MIN. SECURE GEOTEXTILE FABRIC WITH LANDSCAPE STAPLES EVERY 12-24" O.C. TYP. MIN. 11" METAL T-STAKES LOCATED 8-10' O.C. ADJACENT WORK AREA HIGHLY VISIBLE FLAGGING MAX. 10 FEET WELDED WIRE MESH FENCE FLEXI-PAVE ABOVE GRADE NOTES: 1. ATTACHMENT OF SIGNS TO TREES IS PROHIBITED. 2. SIGNS SHOULD BE PROPERLY MAINTAINED. 3. AVOID INJURY TO ROOTS WHEN PLACING POSTS FOR THE SIGNS. NOT TO SCALE DEVELOPER'S NAME: CONTACT PERSON OR OWNER: ADDRESS: PHONE AND EMAIL: SIGNATURE: Expiration HEIGHT AS DIRECTED BY THE ARBORIST Do Not Disturb Seedlings, Shrubs or Trees FOREST CONSERVATION DETAILS 2"x4" MIN. BOARD FC5.1
Kim ing DEVELOPER'S NAME: CONTACT PERSON OR OWNER: ADDRESS: PHONE AND EMAIL: SIGNATURE: 03/19/15 Expiration FOREST CONSERVATION DETAILS FC5.2