FIRE PREVENTION GUIDELINE

Similar documents
SAFETY. USE OF SAFETY CHECK LISTS A safety check for compliance with current regulations should be performed yearly.

Life Safety - Means of Egress/Exits NFPA 101

Residential Based Care Facility Guidelines

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal

Short-Term & Accessory Short-Term Rental Safety Certification

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

Family Foster Home Fire Safety Evaluation Checklist Instructions

FIRE PREVENTION STANDARDS

CHAPTER 7 ALTERATIONS LEVEL

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION GUIDELINE RESIDENTIAL CARE FACILITIES 2007 CBC/CFC (R-3.1)

Large Family Daycare Guideline

GENERAL GROUNDS. Inspector Name: Inspector Signature:

Residential Care Facilities

To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1.

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU TENANT IMPROVEMENT GROUP A FIRE PLAN REVIEW CHECKLIST

OCFEC Fire Marshal Summary Report

Rental Housing Inspection Guide

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

AUTOMATIC FIRE SPRINKLER SYSTEMS

FIRE PREVENTION EXHIBIT GUIDELINES

For additional information regarding R-3.1 residential care facilities please contact (951)

S000 SITE REVIEW APPR NO. FIRE CODE COMPLIANCE ITEM

Site Address: Bldg./Suite #: Departments Phone Date Approval Signature A) Planning COMMENTS:

APPLICATION FOR Large Family Day Care Permit

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

Common Fire Code Violation Checklist. Listed are some of the most commonly found fire code violations and should not be considered as all inclusive.

Denver Fire Department Fire Prevention Division

Section 8 Housing Choice Voucher Program. Housing Quality Standards (HQS) Inspection Checklist

DEPARTMENT OF CONSUMER AND INDUSTRY SERVICES DIVISION OF ADULT FOSTER CARE LICENSING ADULT FOSTER CARE FACILITIES

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST STANDPIPE SYSTEMS

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

City of Philadelphia

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

Residential Alcohol & Drug Rehabilitation Facilities

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

MULTI-LEVEL & COVERED BOOTH CONDITIONS

Residential-based Care Facility R-4 Guideline

INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

FIRE & LIFE SAFTEY STANDARD

Residential Large Family Daycare Facilities

Secondary Suites. Guidelines for the construction of Accessory Secondary Suites in the City of Abbotsford August

H BUTCH BROWNING FIRE MARSHAL BUILDING REHABILITATION

FIRE SAFETY REQUIREMENTS FOR PRE RESIDENTIAL BUILDINGS OF THREE OR MORE STORIES (DOROTHY MAE ORDINANCE - NO. 158,963)

City of Rehoboth Beach

FIRE SAFETY INSPECTION REPORT

C i t y o f G r o v e r B e a c h ADMINISTRATIVE SERVICES DEPARTMENT

Residential Care Facilities Requirements

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

BUILDING DIVISION. Multi-family Rental Inspection Program SELF-CERTIFICATION APPLICATION

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

HIGH-RISE RETROFIT ORDINANCES - NO and NO

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Clark County Department of Building & Fire Prevention 4701 West Russell Road, Las Vegas, NV (702) FAX (702)

Plan Review Check List Fire Alarm System

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

ADMINISTRATIVE ORDER # CERTIFICATES OF USE AND OCCUPANCY FOR EXISTING BUILDINGS

PRESENTERS OVERVIEW COMMUNITY WORKSHOP OVERVIEW OF THE 2010 EDITION OF THE CALIFORNIA BUILDING STANDARDS CODE AND LOCAL AMENDMENTS

New School Construction: Safe School Opening. OAR and IOR Joint Training February 17, 2005

FIRE SAFETY INSPECTION REPORT

FIRE SPRINKLER SYSTEMS POLICY

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

Department of Planning & Community Jefferson Station 1526 E. Forrest Avenue Suite 100 East Point, GA 30344

Checklist For Building Inspection & Fire Safety

Access Aisle (Van) (Flow Test) Water Mains (Location & Sizes) Building Entrances. Building, Facilities, Element. Curb Ramps (Built-up)

FIRE APPARATUS ACCESS AND WATER SUPPLY GUIDELINE

ALABAMA. Downloaded

FIRE SAFETY INSPECTION REPORT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

Burien/Normandy Park Fire Department 900 SW 146 th ST PO Box Burien, WA BP (206) Fax (206)

Residential Care Facilities Having 6 or Fewer Clients Classified in the California Building Code as R-3.1 Occupancies

FIRE SPRINKLER SYSTEMS POLICY

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION

Commercial Business Licensing Requirements

4. Distances to property line, buildings, other tents, parked vehicles and engines;

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

COMMERCIAL KITCHEN SUPPRESSION SYSTEMS INFORMATION PACKET

RESIDENTIAL FIRE SPRINKLER SYSTEMS POLICY

INTERIOR FINISH REVIEW

FIRE APPARATUS ACCESS

CHRISTIAN BROTHERS RISK MANAGEMENT SERVICES Self Inspection Checklist

Fort Bragg Fire and Emergency Services Division Fire Safety Survey For use of this form, see FB Reg 420-1, the proponent agency for this form is DES.

GENERAL AREAS OF INSPECTION

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

Educational Occupancies

TRI-LAKES MONUMENT FIRE PROTECTION DISTRICT

INITIAL FIRE SAFETY ASSESSMENT

A GUIDE TO THE ROCK ISLAND HOUSING CODE. Prepared By: The City of Rock Island Inspection Division

INITIAL FIRE SAFETY ASSESSMENT

CITY OF PASADENA FIRE DEPARTMENT

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

Requirements for the protection of High-Piled Combustible Storage (HPCS) Effective Date: January 2011

Certificate of Inspection CHECKLIST

AUSTIN FIRE DEPARTMENT SIA PROCEDURES FOR ANNUAL TESTING OF BUILDINGS WITH STAIRWELL AND VESTIBULE PRESSURIZATION SYSTEMS

Fire Evacuation Plan Health Sciences & Human Services Library. UMB POLICE or

FIRE SAFETY INSPECTION REPORT

Transcription:

Title: Fire Escapes Number: FPG-07 Effective Date: 01/01/2008 Revised Date: 03/01/2009 Code References: California Fire Code (CFC), California Code of Regulations (CCR) Title 19, Merced Municipal Code (MMC) Note: This guideline is a summary of Fire Department clarifications and interpretations of City and State Codes and nationally recognized standards in accordance with the currently adopted edition of the Fire Code. Information contained herein applies to typical circumstances and may not address all situations. Scope This Guideline has been developed to assist the public and business community with the inspection, testing and certification requirements for fire escapes. Codes and Guidelines This guideline shall apply to buildings provided with one or more fire escapes in accordance with the California Fire Code, California Code of Regulations, Title19 and the Merced Municipal Code. Permits Required A Fire Code permit is not required. Definitions Fire Escape Assembly: A secondary exit attached to the exterior wall of a building that is two or more stories in height and which provides emergency egress from the building. Fire escape assemblies shall include stairs, railings, landings, ladders and all associated safety equipment Specific Requirements 1. Inspection All fire escape assemblies shall be inspected at least annually by a structural engineer or trained individual approved by the Fire Marshal. The following items must be reviewed and documented on the attached Fire Escape Checklist (page 4). The completed form shall be submitted to the City of Merced Fire Prevention Bureau. a. Visually inspect all stairs, landings, ladders, guards, rails and safety chains. b. Bolts and supports should not be damaged or rusted. c. Paint is in good condition d. Ensure that all landings are accessible from the inside of the building and proper signage is provided. 2. Access Page 1

Access to exterior fire escapes is commonly via doors or windows at the end of a common hallway or via a tenant space/apartment unit. Exit access requirements limit the number and types of locks/locking devices, the size of the opening, size and type of breakable glass, the presence of tools for breaking the glass, and signage for locating the fire escape. 3. Signs Fire escape access points are to be provided with a sign FIRE ESCAPE to be visible on approach. These signs have been installed as paper/plastic/metal signs with external illumination, older style glass light fixtures (green or red) with FIRE ESCAPE painted on them, or newer internally illuminated signs indicating either FIRE ESCAPE or EXIT. Modifications or upgrades to existing signage may be ordered by the Fire Marshal. The preferred wording for signage leading to an exterior fire escape is FIRE ESCAPE. 4. Operation Verify all moving parts, ladders, stairs, windows, and doors are operable a. Operate the ladder mechanism to ensure the ladder travels to the ground without hesitation. The ladder must be stable after reaching the ground. This procedure should be conducted at least twice. b. All escape windows should be opened. The window latch should be free of debris and easy to open. c. Doors should be equipped with approved hardware that is operable without the use of a key or any special knowledge or effort. 5. Repairs A licensed contractor or other qualified person or firm as approved by the Fire Marshal must perform all repairs. Major repairs may require certification and stress testing. 6. Certification All fire escape assemblies must be inspected and certified every five years by a licensed structural engineer or other qualified testing agency as approved by the Fire Marshal. The certification shall be noted through an affidavit delivered to the Fire Marshal. If the fire escape fails to pass certification or requires major repairs a load test may be required by the Fire Marshal after repairs have been completed. 7. Stress Test-Fire Escape Performance Criteria Fire escapes shall comply with the following performance standards: a. Fire escape stairs and balconies shall support their dead load plus a live load of not less than 100 pounds per square foot or concentrated load of 300 pounds placed anywhere on the landing, balcony or stairway so as to produce the maximum stress. Page 2

b. In addition to individually testing each landing/platform, the fire escapes will be tested to evaluate a maximum loading event: Buildings 4 to 8 stories in height must load two adjacent platforms simultaneously. c. All stairway and balcony railings shall support a horizontally applied force of not less than 50 pounds per lineal foot of railing applied at top of railing, or a concentrated load of 200 pounds placed anywhere on the railing so as to produce the maximum stress. d. Building ladders shall be designed and connected to the building to withstand a horizontal force of 100 pounds per lineal foot in any direction; each rung shall support a concentrated load of 500 pounds placed anywhere on the rung so as to produce the maximum stress. Ladder assemblies shall have a minimum vertical load capacity of 100 pounds per lineal foot for each foot of width. Engineered drawings must be submitted to the Fire Marshal s Office for approval that detail where and how loads will be placed for each test for each stair, platform, ladder, and railing. A test procedure shall be provided by the testing company outlining each test. ANNUAL FIRE ESCAPE CHECKLIST Page 3

FOR EXISTING BUILDINGS Building Name: Address: Building Owner: Mailing Address: In Compliance/ Correction Date Not Applicable Needed Corrected 1. Is the fire escape clear and unobstructed? 2. All access doors and windows are operable from the inside with a single action and without the use of a key or any special knowledge or effort? 3. All windows have a minimum unobstructed opening width of 29 X 29. 4. Windows and doors are not stuck and open easily. 5. Proper illuminated fire escape signs in place? 6. Has the fire escape been maintained, and protected from internal and external rust and integrity of the paint been maintained since the date of installation? 7. Handrails checked for integrity? 8. No electrical lines or other hazards are located within 10 feet of the fire escape? 9. Anchoring devices are intact and free from rust or rot? 10. Counterbalance is balanced and operational? 11. Ladders were dropped and stayed down, at grade, when activated and/or released? 12. There were no obstructions preventing ladders from reaching ground level? 13. Operation of the counter balance and ladders was completed twice? 14. All loose bolts, grates and framework tightened, repaired, or replaced as necessary? 15. The last Five-Year Fire Escape Certification was completed by:. Date. Engineer/Inspector of Record: I on this date have inspected and tested the fire escape with this form s criteria and good engineering practices. A copy of this form is to be forwarded to the City of Merced Fire Department at 99 E. 16 th Street, Merced Ca. 95340. Fax (209)- 385-6870 Page 4

Page 5