Comtran Cable. Hub-LINK Cables for Transit Applications

Similar documents
Comtran s VITALink 2 Hour Fire Resistive CIC & CI Free Air Cables. Your trusted solution for fire safety

VITALink. FAQs I. GENERAL QUESTIONS

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

APPENDIX C REGULATORY AGENCIES AND INDUSTRY STANDARDS 1.0 APPLICABLE GOVERNMENT CODES AND REGULATIONS

Product Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables.

Multi-Core Fire Resistant Cable

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

High Performance LSZH Fire Resistant Cable

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

Compact Module. Category 6A FTP Cabling System 1.1

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

Fire Alarm/Life Safety Cable 6

Warning Genuine Counterfeit Electrical Product

Cables and cabling solutions for residential buildings: safety, comfort and environmental-friendliness

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

PRODUCT CATALOGUE Norröna

Nuclear Power Plant LSZH Cable Overview

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

SHIELD TYPE MULTICONDUCTOR MULTIPAIR

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

Quick Reference Applications Guide

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Catalogue Telecommunication Cables INTRODUCCIÓN

Fire Alarm Cables. Features: Countdown. New Labeling System on box. Color Coded Boxes. Zone and Room Markings

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

Cables and cabling solutions for public and office buildings: safety, comfort and environmental-friendliness

Thermocouple Cable TRANSMITTING, SENSING, MEASURING

Wiring Duct Product Selection Guide

SPECIAL ELECTRICAL AND OPTICAL CABLES

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

Caledonian Flame Retardant Coaxial Cables

Wire and Cable The Industry Standard for Rugged, Reliable Performance

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

5. Identification products.

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Second Revision No. 601 NFPA [ Section No [Excluding

Flexible Power Cable DLO

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Security & Control Cables

Telecommunication Cables

PANDUIT 4-PAIR & MULTIPAIR COPPER DATA CABLE PLENUM RATED

Special Provision No. 683S28 December 2017

4.13 Security and System Safety

SAS Security and Alarm Safety Cables

Fire Resistant Cables

Caledonian Fire resistant Coaxial Cables

ENVIRONMENTAL PRODUCT DECLARATION PANDUIT 4-PAIR & MULTIPAIR COPPER DATA CABLE PLENUM RATED

PolyOne is a global polymer solutions provider with the ability to meet regulatory and product

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Single core cables with reduced wall thickness

PERFORMANCE POLYMER SOLUTIONS

CLEARING MISCONCEPTIONS ABOUT LOW-SMOKE, HALOGEN-FREE CABLES

4120 Fire Alarm Network Reference

Overmoulded Cable Assembly Selector Guide

CONNECTION SYSTEMS TRANSIT APPLICATIONS

Company Profile. We are dedicated to providing our customers competitive price and excellent service.

COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

CATEGORY 6A FTP RJ45 SOLUTION

BS /1000V XLPE Insulation LSZH Sheath Cables

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

CATALOG LIQUID-TUFF FLEXIBLE LIQUIDTIGHT CONDUIT CATALOG. Industrial & Commercial Liquidtight Conduit Flexible Metal Conduit A PART OF

PAIRED UNJACKETED. Insulation Nominal Anixter. Paired Conductors Thickness O.D. Number AWG Strand No. IN IN

commercial-type cabling and connectivity products into the industrial landscape.

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

Havells Fire Survival Cables

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

DuraLife TM FPL. Installation Guide. UL 2196 Fire Rated Alarm Cables. Authorities Having Jurisdiction should be consulted before installation.

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

The Quality Connection. BETAflam Fire Resistant Safety Cables

Photovoltaic Cables EN H1Z2Z2-K

Belden Infinity C-TC+ Cables for Extreme Flexing

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

Honeywell Cable & Custom Electronics

FORM 10 ELIGIBLE ASSIGNMENTS OF APPLICANTS

GAS FLOODING SYSTEM FOR CIFF AT BASEMENT

Sensor and transducer cables

FIRE RESISTANT CABLES

SECTION INTRUSION DETECTION A. SCOPE OF WORK FOR DESIGNER AND CONSULTANTS

Home Theater Cables. Your complete solution for high-end audio transmission, stereo, professional audio systems and home theater systems.

13. UNITED KINGDOM Standards Supply Voltage and Plug Configurations 247

AFC Cable Systems: the Cable Industry Leader for Over 80 Years

Brand Portable Power Cord & Control Cable Solutions

Transcription:

Comtran Cable Hub-LINK Cables for Transit Applications

Overview Hub-LINK rail transit cables are designed to resist the rugged conditions of the underground and at-grade environments, including: Temperature extremes Moisture Petrochemicals Salt air Rodent damage Sunlight Hub-LINK cables must meet strict specifications for flame propagation, smoke density, halogen content, and toxicity to maximize passenger safety in the event of a fire. They are routed through conduits, duct banks, cable trays, or hung by messenger wire. These cables provide the medium to transmit analog and digital data at low voltage power to support various telephone circuits and general communication services throughout the transit infrastructure, as well as other outside and tunnel applications. Success Stories Hub-LINK cables have proven success with installations in major transportation systems throughout the country. These include: Honolulu Area Rapid Transit (HART) BART Santa Clara Valley Berryessa Extension (SVBX) project in San Jose L.A. Metro Crenshaw Station SR 99 Tunnel in Seattle Silver Line Dulles Corridor project in Washington D.C. Various Superstorm Sandy Rebuild Projects in New York City (East River, Queens Midtown Tunnel) 7-Line Extension/Javits Center in New York City World Trade Center in New York City Hudson Yards in New York City Amtrak Hudson River Tunnels in New York City

New York City Transit (NYCT) Approved HUB-LINK TRANSIT COMMUNICATIONS APPROVED FOR NYCT PRODUCT CLASS 20 GROUP 72 Comtran Part Number Number of Pairs AWG NYCT Stock Number Maximum O.D. Nominal Weight (lbs./1000 ft.) 36071 12 22 20-72-0426 0.67 224 36053 25 22 20-72-0726 0.83 310 36054 50 22 20-72-0826 1.02 485 36055 75 22 20-72-0926 1.20 595 36040 100 22 20-72-1026 1.32 695 36056 150 22 20-72-1126 1.57 1035 36061 200 22 20-72-1226 1.74 1280 ADDITIONAL NYCT TC-7 PRODUCT TYPES Cat 5e/6/6e Shielded & Unshielded Data Communications Cables Twisted-Pair Telephone Wire (cross-connect) Communications Cable - 16, 19, 22 AWG Power Supervisory Communications Cable Multiple-Pair Inside Telephone Cable (Riser & Plenum) Inside-Outside Telephone Station Wire 1 Hour and 2 Hour VITALink Circuit Integrity Cables High-Temperature Fan Control Cables ARMORED CABLES The use of armored cables is increasing, due to their added mechanical and fluid protection and their conduit-free installation. Types of armored cables offered by Comtran include but are not limited to: Copper Clad and Welded (CCW) RS485 cables for security and intrusion detection applications Aluminum Interlock Armor (AIA) Trackside multi-pair telecom cables for telephone, DSL, VoIP, and 10BaseT Ethernet CCW Signal Code ( Code ) cables for switch and signal communications CCW, ACW, or AIA Cat 6 cables for data network, Power over Ethernet (PoE, IoT), Point of Sale, and surveillance camera applications One through nine-pair 14 AWG Circuit Integrity (CI) fire resistant cables in accordance with UL 2196 and NFPA 130 All of these cables are available with our without an overall jacket, marked in accordance with NYCT specifications. Custom configurations including combined power, copper communication, and fiber optic components are available.

Additional Applications HUB-LINK LSZH TELECOMMUNICATIONS Applications: Fixed guideway or passenger railway tunnels and stations, cable trays in airports, or any mass transit hub location where reduced toxins and flame spread are required. Part Number Number of Pairs AWG Jacket Color 35957 2 22 Gray.270 35958 4 22 Gray.310 35959 6 22 Gray.360 35960 12 22 Gray.440 35961 25 22 Gray.570 35962 50 22 Gray.725 35963 100 22 Gray.970 HUB-LINK LSZH DATA COMMUNICATIONS Applications: Fixed guideway or passenger railway tunnels and stations, cable trays in airports, or any mass transit hub location where reduced toxins and flame spread are required. Part Number Number of Pairs AWG Jacket Color 35977 (Cat 6) 4 23 Gray.265 35978 (Cat 5e) 4 24 Gray.288 HUB-LINK LSZH LOW VOLTAGE LIGHTING Applications: New and rebuilt bridges, tunnels, walkways, and passenger platforms. Part Number Number of Conductors AWG Jacket Color 36385 2 18 Black.249 HUB-LINK LSZH INDIVIDUALLY SHIELDED Applications: Control and monitoring functions for corrosion protection systems. Part Number Number of Conductors AWG Jacket Color 36372 4 12 Black.394

Testing NFPA CODES AND STANDARDS: All Hub-LINK cables are in conformance with NFPA 130 for fixed guideway transit systems and NFPA 502 for road tunnels, bridges, and other limited access highways. These standards call out the following: FT-4/IEEE 1202 Flame Test Conformance Low Smoke Insulation Systems UL or NRTL Listing per NFPA 70 UNDERWRITERS LABORATORIES (UL) TESTING: C(UL)US Type CMR-LS, CMG-LS, and CM-LS products have undergone extensive physical testing per UL 444 (Communications Cables) and burn testing per UL 1666 (test for flame propagation height of electrical cables installed vertically in shafts). They have also successfully passed the Limited Smoke testing to FT-4/IEEE 1202 to carry the additional LS marking which is above and beyond NYCT TC-7 requirements. ADDITIONAL PHYSICAL/SMOKE/TOXICITY TESTING (TC-7): Fluid Immersion (Lubricating and Hydraulic Oil, Gas, and Water) Tear Resistance Smoke Generation (Flaming/Non-Flaming) Smoke and Toxicity Index Acid Gas Halogen Content Horizontal Abrasion Light Absorption (UV) & Water Absorption Environmental Stress Crack Resistance Cold/Hot Bend Cable Impact Jacket Shrink-back Heat Distortion ELECTRICAL TESTING PER ANSI/TIA-568-C.2 (CATEGORY 3): Conductor Tolerances DC Resistance Attenuation Impedance Capacitance Mutual Capacitance Capacitance Unbalance (pair to pair and pair to ground) Crosstalk Insulation Resistance Conductor-to-Conductor Proof Test Core-to-Shield DC Proof Shield Resistance Continuity

Global Leader of Specialty Communications Cable Solutions Want to learn more? Contact us: Toll Free: 800-842-7809 Email: sales@comtrancorp.com www.comtrancorp.com Like us on Facebook: facebook.com/comtrancable Follow us on LinkedIn: linkedin.com/company/comtran-cable-llc Follow us on Twitter: twitter.com/comtrancable