AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

Similar documents
INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Wind. Service instruction

Turbo. Service Instructions

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

Aero. Service Instructions

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

HEAT RECOVERY AIR HANDLING UNIT

Calm. Service Instructions

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

AXIAL FANS USER S MANUAL

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

CENTRIFUGAL FANS user's manual. model VENTS VK.

DUCT COOLERS KWK KFK OPERATION MANUAL. KWK_KFK_v2(4)_EN.indd :35:29

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

INTELLIGENT AXIAL FAN user's manual

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

USER S MANUAL. VKP Series INLINE FAN

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

Axial intelligent fan USER S MANUAL

INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL

Centrifugal inline fans

INLINE MIXED-FLOW FANS VENTS TT SERIES USER'S MANUAL.

AXIAL DOMESTIC FANS. User manual LARUS LIBELLA FENESO CYCNUS CICONUS SIGILA SIGILA MOTION

CENTRIFUGAL CEILING EXTRACT FAN

HEAT RECOVERY VENTILATOR

CENTRIFUGAL CEILING EXTRACT FAN

AXIAL FANS user's manual. model Quiet

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

USER'S MANUAL PS

AIR HANDLING UNIT WITH HEAT RECOVERY

USER'S MANUAL INLINE CENTRIFUGAL FANS IN SOUND-INSULATED CASING VS, VS EC SERIES

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

Air handling unit. BlauAir RH USER S MANUAL

USER S MANUAL DN-2. Drain pump

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

HEAT RECOVERY AIR HANDLING UNITS KOMFORT EC S S11/S15 KOMFORT EC SB S11/S15

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

HEAT RECOVERY AIR HANDLING UNITS

USER S MANUAL VUT 160 P2B EC A14 VUT 160 PB EC A14 VUT 350 P2B EC A14 VUT 350 PB EC A14 HEAT RECOVERY AIR HANDLING UNIT

Turbo Inline Fan, White - Non Illuminated Art no.33500

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW

White - Non Illuminated Art no White - Cool White LED Art no.32600

USER S MANUAL VUT V(B) EC А14 VUE V(B) EC А14. Heat/heat and humidity recovery air handling unit

USER S MANUAL AiR duct heater with integrated temperature control UNit or A control UNit

VUT 350 H VUT 500 H VUT 530 H VUT 600 H VUT 1000 H VUT 2000 H HEAT RECOVERY AIR HANDLING UNIT

Installation manual Mini Comfort 50 S/L 07/ V EN

KKKKKKKCOOKER HOOD INSTRUCTION MANUAL

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

CANOPY RANGEHOOD. instruction manual V3FC60SS & V3FC90SS 12 MONTH WARRANTY

ISCG90SS _03 ISCG90SS

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

G Installation manual Solitude - dmev unit

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

Installation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke

OSC... INSTRUCTION MANUAL - KITCHEN EXTRACTOR HOOD

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

Cooker Hood User Manual

USER'S MANUAL. Micra 150 HEAT RECOVERY UNIT

Box60/ 70/ 90. Box60_70_90 v8

IN 900 BIC UK INSTRUCTION MANUAL - KITCHEN EXTRACTOR HOOD

Instructions for use PHPC 6.4F AM X

Trumatic E. Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7. To be kept in the vehicle!

Safety and Instruction Manual

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

CAN60 / CAN60SV _01 CAN60_CAN60SV. WARNING: Read the instructions before using the appliance.

General safety precautions English

Operating instructions

UNDERMOUNT RANGEHOOD. instruction manual VPP52S & VPP90S 12 MONTH WARRANTY

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

General safety precautions English

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

ACN SMOKE INSTALLATION AND MAINTENANCE

BIG BEAR VORTEX FAN MODEL #BB-2

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

HEATING AND COOLING DEVICE AGC

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

TTV 4500 / TTV 4500 HP / TTV 7000

100cm Chimney Hood GB IE

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

AP-EH500-L/RQA9837. Installation Guide

Glue Gun 25W TTB580HTL. Barcode: WARNING: Read the instructions before using the product!

VH60SS 60CM VISOR HOOD STAINLESS STEEL

Table of Contents. Safety Information Content Checklist Measurements Preparation Installation

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Operating Manual. VIENNA Hot Display

OPERATION AND MONTAGE MANUAL ROOF FANS

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

Lucci Designer Hi Flow Exhaust Fan

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

USER S OPERATION MANUAL HL-RD 2000 E EC HL-RD 3000 E ЕС

Transcription:

TUBO-M/MZ AXIS-QA AXIS-Q TUBO-F AXIS-QR AXIS-F AXIS-QRA AXIS-QA G AXIAL FANS EN OPERATION MANUAL

www.blaubergventilatoren.de CONTENT 3 Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 4 Fan design 4 Delivery set 4 Modifications and options 5 Technical data 10 Mounting and operation guidelines 11 Mounting sequence 11 Installation and connection to power mains 13 Maintenance 14 Warranty card 2

www.blaubergventilatoren.de BLAUBERG Company is happy to offer your attention the new high-quality axial fans Blauberg Axis and Blauberg Tubo. The solid team of high-qualified professionals with many years of working experience, technological innovations in design and production, high-quality components and materials from the top worldwide producers have become the precondition for the best fan in its class. INTRODUCTION The present operation manual contains technical description, technical data sheets, operation and mounting guidelines, safety precautions and warnings for safe and correct operation of the fan. GENERAL The axial fans Axis, Tubo are not a ready for use product. It is a component unit designed for integration into air conditioning and ventilation systems. The fans Axis-Q, Axis-QR, Axis-QA, Axis-QRA are designed for direct air exhaust. The models Axis-F are designed for connection to Ø 205 mm up to 645 mm air ducts and the models Tubo-M, Tubo-MZ are designed for connection to Ø 160 mm up to 315 mm air ducts. The fan has IEC Protection Class I and must be grounded. The fans are allowed for operation only after final mounting, that includes installation of protecting devices in compliance with DIN EN ISO 13875 (DIN EN ISO 12100) as well as other construction safety equipment. The fan design is regularly improved, so some models can slightly differ from those ones described in this service instruction. SAFETY RULES The fan complies with the requirements according to the EU norms and directives, to the relevant EU-Low Voltage Equipment Directives, EU- Directives on Electromagnetic Compatibility. All operations related to the fan electrical connections, servicing and repair works are allowed only after the fan disconnection from power mains. All mounting and servicing operations are allowed for duly qualified electricians with valid electrical work permit for electric operations at the units up to 1000 V after careful study of the present user's manual. Please follow the safety regulations and working instructions (DIN EN 50 110, IEC 364). Make sure the impeller and the casing are not damaged before connecting the fan to power mains. The casing internals must be free of any foreign objects which can damage the impeller blades. Disconnect the fan from power mains prior to any operations related to the fan servicing and repair works. Take measures to prevent contact with the fan to avoid physical damages during the fan step and start-up. Misuse of the product or any unauthorized modification are not allowed. The fan is designed for connection to ac single-phase or ac three-phase power mains, see Technical Data. The fan is rated for permanent operation during non-stop power supply. Take steps to prevent ingress of smoke, carbon monoxide and other combustion products into the room through open chimney flues or other fire-protection devices. Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting. The maximum permitted pressure difference per living units is 4 Pa. The transported air must not contain any dust or other solid impurities, sticky substances or fibrous materials. The fan is not designed for use in an inflammable and explosive medium. The transported medium must not have an aggressive effect on steel at the temperature stated on pages 5 8 of the section Technical data. Do not close or block the fan intake or exhaust vent not to disturb the normal air passage. Do not sit on the fan and do not put objects on the fan. Follow the manual guidelines to ensure trouble-free operation and long service life of the product. STORAGE AND TRANSPORTATION RULES Store the delivered product in the manufacturer's original packing box in a dry ventilated premise with the ambient temperature from +5 C up to +40 C and relative humidity less than 80 % at the temperature +25 C. Store the fan in an environment with minimized risk of mechanical damages, temperature and humidity fluctuations. Store the fan inside a room or under a shelter. Transport of the product is allowed by any vehicle in the manufacturer's original packing box. Use hoist machinery for handling and transportation to prevent possible mechanical damages of the product. Fulfil the requirements for transportation of the specified cargo type during cargo-handling operations. Do not expose the product to extremely low or high temperatures. MANUFACTURER'S WARRANTY The fan complies with the requirements according to the EU norms and directives, to the relevant EU-Low Voltage Equipment Directives, EU- Directives on Electromagnetic Compatibility. We hereby declare that the following product complies with the essential protection requirements of Electromagnetic Council Directive 2004/108/ EC, 89/336/EEC and Low Voltage Directive 2006/95/EC, 73/23/EEC and CE-marking Directive 93/68/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. This certificate is issued following test carried out on samples of the product referred to above. Assessment of compliance of the product with the requirements relating to electromagnetic compatibility was based on the following standards. The manufacturer hereby warrants normal operation of the fan over the period of 2 years from the retail sale date provided observance of the installation and operation regulations. In case of failure due to faulty equipment during the warranty period the consumer has the right to exchange it. If case of no confirmation of the sale date, the warranty term shall be calculated from the manufacturing date. The replacement is offered by the Seller. The MANUFACTURER shall not be liable for any damage resulting from any misuse of or gross mechanic interference with the fan. Please follow the operation guidelines always.! ATTENTION The product is not allowed for use by children and persons with reduced physical, mental or sensory capacities, without proper practical experience or expertise, unless they are controlled or instructed on the product operation by the person(s) responsible for their safety. Supervise the children and do not let them play with the product. WARNING Do not dispose in domestic waste. The unit contains in part material that can be recycled and in part substances that should not end up as domestic waste. Dispose of the unit once it has reached the end of its working life according to the regulations valid where you are. 3

www.blaubergventilatoren.de FAN DESIGN AXIS-Q / AXIS-QR / AXIS-QA / AXIS-QRA casing cover DELIVERY SET fan 1 item; operation manual. flange flange MODIFICATIONS AND OPTIONS Fig. 1 terminal block impeller AXIS-Q Fan with a square mounting plate AXIS-QR Fan with a round mounting plate FAN DESIGN AXIS-F DELIVERY SET casing terminal block fan 1 item; operation manual. impeller Fig. 2 FAN DESIGN TUBO-M / TUBO-MZ DELIVERY SET fan 1 item; screws and dowels - 4 items; mounting brackets 2 items; operation manual. casing MODIFICATIONS AND OPTIONS Fig. 3 impeller mounting bracket TUBO-M Fan made of polymer coated steel TUBO-MZ Fan made of galvanized steel 4

www.blaubergventilatoren.de TECHNICAL DATA AXIS-Q / AXIS-QR / AXIS-F Technical data 200 2E 250 2E 250 4E 300 2E Voltage 1~ 220-240 1~ 220-240 1~ 220-240 1~ 220-240 Frequency [Hz] 50 60 50 60 50 60 50 60 Power [W] 55 61 80 91 50 56 145 178 Current [A] 0.26 0.28 0.4 0.42 0.22 0.24 0.66 0.79 Max. air flow [m 3 /h] 860 875 1050 1150 800 865 2230 2280 RPM [min -1 ] 2300 2550 2400 2990 1380 1730 2300 2410 Noise level, 3 m [dba] 50 51 60 61 55 56 60 61 Max. transported air temperature [ C] -30 +60-30 +50-30 +60-30 +50-30 +60-30 +50-30 +60-30 +50 Ingress Protection Rating 300 4E 350 4E 400 4E 450 4E Voltage 1~ 220-240 1~ 220-240 1~ 220-240 1~ 220-240 Frequency [Hz] 50 60 50 60 50 60 50 60 Power [W] 75 92 140 147 180 240 250 325 Current [A] 0.35 0.4 0.65 0.66 0.82 1.08 1.2 1.46 Max. air flow [m 3 /h] 1340 1475 2500 2650 3580 3890 4680 4790 RPM [min -1 ] 1350 1405 1380 1700 1380 1655 1350 1600 Noise level, 3 m [dba] 58 59 62 63 63 64 64 65 Max. transported air temperature [ C] -30 +60-30 +50-30 +60-30 +50-30 +60-30 +50-30 +60-30 +50 Ingress Protection Rating 500 4E 550 4E 630 4E 630 6E Voltage 1~ 220-240 1~ 220-240 1~ 220-240 1~ 220-240 Frequency [Hz] 50 60 50 60 50 60 50 60 Power [W] 420 455 550 654 750 979 540 610 Current [A] 1.95 2.05 2.55 2.88 3.5 4.26 2.4 2.74 Max. air flow [m 3 /h] 7060 7130 8800 8970 11900 12100 10900 10990 RPM [min -1 ] 1300 1630 1300 1580 1360 1625 850 1075 Noise level, 3 m [dba] 69 69 70 71 75 76 72 72 Max. transported air temperature [ C] -30 +60-30 +50-30 +60-30 +50-30 +60-30 +50-30 +60-30 +50 Ingress Protection Rating 5

www.blaubergventilatoren.de 250 2D 250 4D 300 2D 300 4D Voltage 3~ 400 3~ 400 3~ 400 3~ 400 Frequency [Hz] 50 60 50 60 50 60 50 60 Power [W] 80 92 60 89 145 165 75 94 Current [A] 0.22 0.24 0.17 0.22 0.25 0.29 0.22 0.25 Max. air flow [m 3 /h] 1060 1150 850 885 2310 2390 1310 1530 RPM [min -1 ] 2600 3030 1400 1750 2350 2570 1380 1640 Noise level, 3 m [dba] 60 62 55 55 60 61 58 60 Max. transported air temperature [ C] -30 +60-30 +50-30 +60-30 +50-30 +60-30 +50-30 +60-30 +50 Ingress Protection Rating Axis-Q / Axis-QR / Axis-F 350 4D Axis-Q / Axis-QR / Axis-F 400 4D Axis-Q / Axis-QR / Axis-F 450 4D Axis-Q / Axis-QR / Axis-F 500 4D Axis-Q / Axis-QR / Axis-F 550 4D Axis-Q / Axis-QR / Axis-F 630 4D Voltage 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 3~ 400 Frequency [Hz] 50 60 50 60 50 60 50 60 50 60 50 60 Power [W] 140 150 180 195 250 275 450 370 750 600 800 910 Current [A] 0.38 0.41 0.47 0.55 0.6 0.65 0.9 0.7 1.5 1.1 1.6 1.68 Max. air flow [m 3 /h] 2520 2590 3740 3870 5280 5350 6570 6230 9700 7380 12200 12400 RPM [min -1 ] 1380 1640 1380 1625 1360 1620 1300 1605 1350 1605 1320 1585 Noise level, 3 m [dba] 62 63 64 65 65 66 72 67 73 69 78 79 Max. transported air temperature [ C] Ingress Protection Rating -30 +60-30 +50-30 +60-30 +50-30 +60-30 +50-30 +60-30 +50-30 +60-30 +50-30 +60-30 +50 Overall dimensions Ø D Ø d B B1 L Axis-Q 200 2E 210 7 312 260 145 3.9 Axis-Q 250 2E / Axis-Q 250 2D 260 7 370 320 155 4.2 Axis-Q 250 4E / Axis-Q 250 4D 260 7 370 320 155 4.1 Axis-Q 300 2E 326 9 430 380 195 5.3 Axis-Q 2 300 D 326 9 430 380 155 5.3 Axis-Q 300 4E 326 9 430 380 195 5.1 Axis-Q 300 4D 326 9 430 380 155 5.1 Axis-Q 350 4E / Axis-Q 350 4D 388 9 485 435 200 7.1 Axis-Q 400 4E / Axis-Q 400 4D 417 9 540 490 240 8.8 Axis-Q 450 4E / Axis-Q 450 4D 465 11 576 535 250 10.6 Axis-Q 500 4E / Axis-Q 500 4D 520 11 655 615 260 14.2 Axis-Q 550 4E / Axis-Q 550 4D 570 11 725 675 280 16.6 Axis-Q 630 4E / Axis-Q 630 4D 650 11 800 710 295 22.6 Axis-Q 630 6E 650 11 800 710 295 22.6 Fig. 4 Axis-Q 6

www.blaubergventilatoren.de Overall dimensions Ø D Ø D1 Ø D2 Ø d L Axis-QR 200 2E 210 250 280 7 145 2.5 Axis-QR 250 2E / Axis-QR 250 2D 260 295 320 7 155 3.4 Axis-QR 250 4E / Axis-QR 250 4D 260 295 320 7 155 3.4 Axis-QR 300 2E 326 380 397 9 195 4.4 Axis-QR 300 2D 326 380 397 9 155 4.4 Axis-QR 300 4E 326 380 397 9 195 4.7 Axis-QR 300 4D 326 380 397 9 155 4.7 Axis-QR 350 4E / Axis-QR 350 4D 388 442 460 9 200 6.3 Axis-QR 400 4E / Axis-QR 400 4D 417 504 528 9 240 8.3 Axis-QR 450 4E / Axis-QR 450 4D 465 578 607 11 250 9.8 Axis-QR 500 4E / Axis-QR 500 4D 520 590 655 11 260 12.2 Axis-QR 550 4E / Axis-QR 550 4D 570 645 710 11 280 15.0 Axis-QR 630 4E / Axis-QR 630 4D 650 760 800 11 295 20.8 Axis-QR 630 6E 650 760 800 11 295 20.8 Fig. 5 Axis-QR Ø D Ø D Ø D Ø d B L Axis-F 200 2E 205 235 255 7 290 120 1.95 Axis-F 250 2E / Axis-F 250 2D 260 286 306 7 340 150 3.84 Axis-F 250 4E / Axis-F 250 4D 260 286 306 7 340 150 3.96 / 3.84 Axis-F 300 2E / Axis-F 300 2D 310 356 382 7 410 160 5.31 Axis-F 300 4E / Axis-F 300 4D 310 356 382 7 410 160 5.59 / 5.31 Axis-F 350 4E / Axis-F 350 4D 362 395 421 9.5 450 160 6.37 Axis-F 400 4E / Axis-F 400 4D 412 438 465 9.5 500 170 8.39 Axis-F 450 4E / Axis-F 450 4D 462 487 515 9.5 550 200 10.65 Axis-F 500 4E / Axis-F 500 4D 515 541 570 9.5 600 220 Axis-F 550 4E / Axis-F 550 4D 565 605 636 11.5 660 230 Axis-F 630 4E / Axis-F 630 4D 645 674 715 11.5 740 250 12.65 / 11.0 17.3 / 13.9 20.13 / 16.4 Fig. 6 Axis-F 7

www.blaubergventilatoren.de AXIS-QA / AXIS-QRA / TUBO-MZ / TUBO-F Technical data Tubo-F 200 2E* Tubo-F 250 2E* Tubo-F 250 4E* Tubo-F 300 2E Tubo-F 300 4E* Tubo-F 350 4E Voltage, 50 Hz [V] 230 230 230 230 230 230 Power [W] 55 80 50 145 75 140 Current [A] 0.26 0.4 0.22 0.66 0.35 0.65 Max. air flow [m 3 /h] 860 1050 800 2230 1340 2500 RPM [min -1 ] 2300 2400 1380 2300 1350 1380 Noise level, 3 m [dba] 50 60 55 60 58 62 Max. transported air temperature [ C] -30 +60-30 +60-30 +60-30 +60-30 +60-30 +60 Ingress Protection Rating IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 * Compliant to the ErP-regulation (EC) 327/2011, the power consumption at optimum efficiency is < 125 W. Axis-QA / Axis-QRA / Tubo-M / Tubo-MZ / Axis-QA G 150 Axis-QA / Axis-QRA / Tubo-M / Tubo-MZ/ Axis-QA G 200 Axis-QA / Axis-QRA / Tubo-M / Tubo-MZ/ Axis-QA G 250 Axis-QA / Axis-QRA / Tubo-M / Tubo-MZ 315 Voltage, 50 Hz [V] 230 230 230 230 Power [W] 36 43 68 110 Current [A] 0.26 0.28 0.48 0.75 Max. air flow [m 3 /h] 200 405 1070 1700 RPM [min -1 ] 1300 1300 1300 1300 Noise level, 3 m [dba] 33 32 48 54 Max. transported air temperature [ C] 40 40 40 40 Ingress Protection Rating Tubo-M IPX4 Tubo-M IPX4 Tubo-M IPX4 Tubo-M IPX4 Overall dimensions Ø D Ø d B B1 L Axis-QA 150 162 7 250 210 120 2.5 Axis-QA 200 208 7 312 260 120 3.0 Axis-QA 250 262 7 370 320 140 3.5 Axis-QA 315 312 9 430 380 170 6.1 Axis-QA Fig. 7 8

www.blaubergventilatoren.de Ø D Ø D1 Ø D2 Ø d L Axis-QRA 150 162 190 220 7 120 2.5 Axis-QRA 200 208 270 300 7 120 2.5 Axis-QRA 250 262 330 360 7 140 3.0 Axis-QRA 315 312 390 420 9 170 5.1 Axis-QRA Fig. 8 Ø D B L L1 L3 Tubo-M 150 / Tubo-MZ 150 162 183 220 40 30 1.8 Tubo-M 200 / Tubo-MZ 200 208 228 220 40 30 2.4 Tubo-M 250 / Tubo-MZ 250 262 283 270 55 30 3.7 Tubo-M 315 / Tubo-MZ 315 315 337 278 55 40 4.9 Tubo-M / Tubo-MZ Fig. 9 Ø D B L H L1 Tubo-F 2E 200 199 227 220 300 30 3.5 Tubo-F 250 2E 249 282 250 320 30 4.5 Tubo-F 250 4E 249 282 250 320 30 4.5 Tubo-F 300 2E 299 326 250 390 40 6.3 Tubo-F 4E 300 299 326 250 390 40 6.3 Tubo-F 350 4E 349 378 300 410 40 8.4 Tubo-F Fig. 10 Ø D Ø d B B1 L Axis-QA 150 G 162 7 325 275 127 2.5 Axis-QA 200 G 208 7 325 275 127 3.0 Axis-QA 250 G 262 7 325 275 152 3.5 Axis-QA G Fig. 11 Ø D Ø D1 H H1 MD / MDZ 148/158 148 158 140 55 0.3 MD / MDZ 198/204 198 204 140 55 0.4 MD / MDZ 248/258 248 258 150 65 0.42 MD / MDZ reducer for Tubo-M fans The Tubo-M fans are equipped with MD (polymer-coated steel) and MDZ Zn (galvanised steel) reducers for connection to 150 mm, 200 mm and 250 mm air ducts. The reducers are not included in the delivery set and must be ordered separately. Fig. 12 9

www.blaubergventilatoren.de MOUNTING AND OPERATION GUIDELINES The air motion direction in the system must match the pointer on the fan casing. Install the fan to ensure sufficient and quick access for servicing and repair operations. The fan must be grounded. While mounting protect the fan against water ingress in the following way: 1. Install an outer hood above in case of vertical mounting position, fig. 13. Fig. 13 MOUNTING SEQUENCE AXIS-QA Fig. 15 Fig. 14 AXIS-QR AXIS-Q 10 AXIS-QRA Fig. 16 Fig. *** 17 Fig. 18 Fig. 19 Fig. 20 Fig. 21 Fig. 22 Fig. 23 Fig. 24 Fig. 25 Fig. 26 Fig. 27

www.blaubergventilatoren.de MOUNTING SEQUENCE AXIS-F MOUNTING SEQUENCE TUBO-M / TUBO-MZ Fig. 28 Fig. 29 Fig. 32 Fig. 33 Fig. 30 Fig. 31 Fig. 34 Fig. 35 Fig. 36 Fig. 37 INSTALLATION AND CONNECTION TO POWER MAINS Connection of the fan to power mains is allowed by a qualified electrician only. The rated electrical parameter are stated on the rating plate. No modifications of internal connections are allowed and will result in void warranty. Connect the fan only to power mains with valid electric standards. The house cabling system must be equipped with an automatic switch at the external input. Connect the fan to power mains through the automatic switch. The contact gap on all poles at least 3 mm. The automatic switch trip current must be in compliance with the fan current consumption, refer Table on pages 5 6. Install the automatic switch to ensure prompt access. AXIS-Q AXIS-QR AXIS-F ~230 V 50 Hz L N PE QF L N X1 1 2 3 4 ~4 5 Cut power supply to the fan off by turning the automatic electric switch QF to OFF position (fig. 38). Take steps to prevent activation of the automatic switch. ~230 V 50 Hz L N PE QF L N X1 1 2 3 4 Fig 39 ~400 V 50 Hz Single-phase fans L1 L2 L3 PE QF L1 L2 L3 X1 1 2 3 4 Fig. 40 Three-phase fans AXIS-QA Fig. 38 The fan wiring diagram is shown in fig. 39 41. Connection sequence of the fan, shown on fig. 42 56. AXIS-QRA TUBO-M / TUBO-MZ AXIS-QA G TUBO-F ~230 V 50 Hz L N QF L N X1 1 2 3 PE Fig. 41 11

www.blaubergventilatoren.de INSTALLATION AND CONNECTION TO POWER MAINS AXIS-Q AXIS-QR Fig. 42 Fig. 43 Fig. 44 Fig. 45 Fig. *** 47 Fig. *** 48 Fig. Abb.49 *** Fig. 51 Fig. 52 Fig. 53 Fig. 55 Fig. 56 AXIS-F Fig. 46 AXIS-QA AXIS-QRA Fig. 50 AXIS-QA G TUBO-M / TUBO-MZ Fig. 54 12

www.blaubergventilatoren.de MAINTENANCE Regular technical supervision and maintenance of the fan are required to ensure the product long service life and non-stop operation. Disconnect the fan from power mains prior to any maintenance operations, fig. 57. Do not place the fan in water (fig. 58). Maintenance of the fan is required and means cleaning the fan surfaces from dust and dirt. Maintenance includes regular cleaning, control of the impeller, motor, impeller blades. Mounting sequence of the fan is shown on fig. 59 70. Fig. 57 Fig. 58 Clean the impeller blades with a soft cloth or a brush wetted in a mild soap solution. Avoid liquid splashing on the motor. Clean the impeller blades thoroughly at least once in 6 months. Operation recommendations: 1. Clean the fan regularly from dust, dirt and foreign objects. 2. Check all fastening connections periodically. 3. Control generated noise and vibration. High vibration may indicate the bearing wear, sticking of the dirt particles contained in the transported air, the impeller blades wear, loose connection between the fan and the air duct. 4. Check periodically the fastening connections, impeller for possible blade damages, check connection of the fan to the air duct and coating. AXIS-Q AXIS-QA AXIS-QR AXIS-QRA AXIS-QA G Fig. 59 Fig. 60 Fig. 61 Fig. 62 Fig. 63 Fig. 64 Fig. 65 Fig. 66 AXIS-F TUBO-M / TUBO-MZ TUBO-F Fig. 67 Fig. 68 Fig. 69 Fig. 70 13

www.blaubergventilatoren.de ACCEPTANCE CERTIFICATE Axial fans Axis TUBO is recognized as serviceable. The unit complies with the requirements according to the EU norms and directives, to the relevant EU-Low Voltage Equipment Directives, EU-Directives on Electromagnetic Compatibility. We hereby declare that the unit complies with the essential protection requirements of Electromagnetic Council Directive 2004/108/EC, 89/336/EEC and Low Voltage Directive 2006/95/EC, 73/23/EEC and CE-marking Directive 93/68/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility, which relate to electrical appliances used in set voltage classes. This certificate is issued following test carried out on samples of the product referred to above. Quality Inspector s Stamp Manufacture Date CONNECTION CERTIFICATE Axial fans Axis TUBO is connected to power mains in compliance with the operation manual requirements by the professional: Company: Expert s Full Name Date Signature WARRANTY CARD Axis TUBO SELLER PURCHASE DATE REPRESENTATIVE IN EU BLAUBERG Ventilatoren GmbH Aidenbachstr. 52 D-81379 Munich, Germany 14

www.blaubergventilatoren.de 15

www.blaubergventilatoren.de BL_AXIS_4(8)_EN