D9412GV2/D7412GV2. Approved Applications Compliance Guide. Control Panels

Similar documents
D9412GV2/D7412GV2. Approved Applications Compliance Guide. Control Panels

Control Panels D9412GV4/D7412GV4/D7212GV4. Approved Applications Compliance Guide

Control Panel. D9412GV4/D7412GV4 v2.00. en UL Installation Instructions

D2412 Control / Communicator Installation Manual

Installation Guide. Control/Communicator

Notification Appliance Circuit Module

D7212GV2. Operation and Installation Guide. Control Panel

DS7465i. Installation Instructions. Input/Output Module

Battery charger modules

D7212 Control/Communicator Operation and Installation Manual

D8125MUX. Operation and Installation Guide. Multiplex Bus Interface

D2412U, D2412UE Control / Communicator Installation Manual

R A D I O N I C S. D7212 Control/Communicator Operation and Installation Manual B 2/ Radionics

Operation and Installation Guide. Zone Expansion Module D8125

INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS

D7053. Installation Instructions Multiplex Input/Output Module

XR10/XR20 Command Processor Panels Installation Guide

D7052. Installation Instructions Multiplex Dual Input Module

Fire Control/Communicator

F220-B6PS/M. Installation Guide. Addressable Detector Bases

Independent Zone Control (I.Z.C.)

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

Multiplex Eight Input Remote Modules

TECHNICAL DATA OBSOLETE

D7044. Installation Instructions Multiplex Single Input Module

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Addressable NAC Output Module D327A

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

AL600ULADA. NAC Power Extender. Installation Guide

D250A/D253/D261AW/D280A/D290 Series

Control Panels B5512/B4512/B3512. en UL Installation Instructions

D1255RB/D1256RB/D1257RB

30.45 Electric Release PDRP-2001

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

EVO192 v3.0 Fire and Burglary What s New

FireNET Plus Wiring Instructions

AL800ULADA. NAC Power Extender. Installation Guide

Booster Power Supply Manual

D2071A. Operation & Installation Guide Fire Alarm Control Panel

Model 17A00 Expansion Enclosure

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

SENTROL ZX440F. Security System Control. Installation/ Programming

D2212 Control/Communicator Installation Manual

MR-2602 Two Zone Fire Alarm Control Panel

FMR Installation Instructions. Addressable Fire System Controller

Control Panels D9412GV4/D7412GV4 v2.03. Installation and System Reference Guide

Installation Guide for models:

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Integrated Security Solutions

Installation Guide for models:

Commercial and Light Industrial Fire Alarm Control Panel

D7050DH. Installation Instructions. Multiplex Photoelectric Duct Smoke Detector

SP-1000X. Panic Device Power Controller Installation Guide. Rev

INSTALLATION GUIDE XR100 SERIES COMMAND PROCESSOR PANEL

DS7400Xi Addressable Control/ Communicator

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

Integrated Security Solutions

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

RELEASE DEVICE CONTROLS

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Specification/ Data Sheet

E S L I N S T A L L A T I O N A N D O P E R A T I O N S M A N U A L ESL Fire Alarm Control Panel ESL

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Installation Instructions

Release Control Fire Alarm Systems

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

Series. Access Power Controllers. Installation Guide

Duct smoke housings, 4-wire D341/D341P and D342/D342P

4100U City and Relay Cards Installation Instructions

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

SPEC SHEET. Simple Expansion Solutions ZONE EXPANSION MODULES: SINGLE AND MULTIPLE POINT

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

VISTA-32FB. Commercial Fire/Burg/CCTV and Access Control Platform FEATURES: Designed to integrate seamlessly with CCTV, access

MODEL 5104B. Installation and Operation Manual. Fire Communicator. Part Number E, 09/04

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

Release Notes for Version 7.05 January 2007

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

Addressable Fire Alarm Control Panel

D720 and D1255 Command Centers

D2071A Fire Control/Communicator Digital Alarm Communicator Transmitter (DACT)

D326A/D334A/D339A. Installation Instructions. Point Contact Modules

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Transcription:

D9412GV2/D7412GV2 EN Approved Applications Compliance Guide Control Panels

D9412GV2/D7412GV2 Approved Applications Compliance Guide Listings and Approvals Listings and Approvals Fire UL Underwriters Laboratories Inc. (UL) lists the D9412GV2/D7412GV2 Control Panels as Signal System Control Units for: Central Station, Local, Auxiliary, Remote Station, Proprietary, and Household Fire Warning. CSFM Approved by the California State Fire Marshal (CSFM) for high-rise and non-high-rise. Burglary UL UL lists the D9412GV2/D7412GV2 Control Panels for: Central Station, Local, Police Connect, Bank Safe and Vault, Mercantile Safe and Vault, and Grade A Household Systems. Department of Defense (DOD) The D9412GV2/D7412GV2 was granted approval for Department of Defense (DoD) installations in Sensitive Compartmented Information Facilities (SCIF). 2 Bosch Security Systems 5/05 F01U003639B

D9412GV2/D7412GV2 Approved Applications Compliance Guide Listings and Approvals. Contents 1.0 Introduction...4 2.0 Optional Compatible Equipment...4 2.1 Burglary Applications...4 2.2 Bank Safe and Vault Applications...4 2.2.1 Control Panel Enclosure Requirements...4 2.2.2 Battery Connections...4 2.2.3 Transmitter...4 2.2.4 Bell Requirements...4 2.2.5 System Configuration Requirements...5 2.2.6 Exit Delay...5 2.2.7 Equipment Requirements...5 2.2.8 Wiring the Rothenbuhler 51/4001-42 High Security Bell to the D9412GV2 or D7412GV2 Control Panel...5 2.3 Fire Applications...8 2.3.1 Four-Wire Smoke Detectors...8 2.3.2 Two-Wire Smoke Detectors...8 2.3.3 Two-Wire Smoke Detector Specifications...8 2.3.4 NFPA Style A (Class B ) Circuit...8 2.3.5 Other Devices...8 2.3.6 UL Listed Two-Wire Smoke Detectors Compatible with the D125 or D125B...9 2.4 Enclosures... 2.4.1 D83 Enclosure... 2.4.2 D88A Enclosure... 2.4.3 D89 Red Fire Enclosure... 3.0 UL/NFPA Compliant Installations... 4.0 Ground Fault Detect Enable...11 5.0 System Chart...12 6.0 System Wiring Diagrams, Issue A...13 6.1 D9412GV2 Wiring Diagrams...13 6.2 D7412GV2 Wiring Diagrams...16 7.0 Current Ratings Charts...19 7.1 D8125MUX...19 7.2 Standby Battery Calculations...20 8.0 NFPA 72 Fire Alarm Applications...21 8.1 Standby Battery Calculation for NFPA 72 Fire Alarm Applications...21 8.2 Central Station or Local Systems...21 8.3 Remote Station or Auxiliary Systems...21 8.4 Household Fire Warning Equipment...22 Figures Figure 1: Rothenbuhler 51/4001-42 High Security Bell Wiring Configuration... 6 Figure 2: Wiring the Rothenbuhler 51/4001-42 High Security Bell to the D9412GV2 or D7412GV2 Control Panel... 7 Figure 3: Ground Fault Detect (S4)... 11 Figure 4: Area 5 Silent Alarm Relay in RPS... 11 Figure 5: D9412GV2 System Wiring Diagram, Power Supply Side... 13 Figure 6: D9412GV2 System Wiring Diagram, Input Points, and Peripheral Devices... 14 Figure 7: D9412GV2 System Wiring Diagram, SDI Devices... 15 Figure 8: D7412GV2 System Wiring Diagram, Power Supply Side... 16 Figure 9: D7412GV2 System Wiring Diagram, Input Points, and Peripheral Devices... 17 Figure : D7412GV2 System Wiring Diagram, SDI Devices... 18 Tables Table 1: UL Listed Two-Wire Smoke Detectors Compatible with the D125 or D125B Modules... 9 Table 2: UL System Chart... 12 Table 3: Current Rating Chart for D8125MUX... 19 Table 4: Current Rating Chart for Standby Battery Calculations... 20 Table 5: Standby Battery Requirements... 21 Table 6: Central Stations or Local Systems Ah Calculation Formula... 21 Table 7: Remote Station or Auxiliary Systems Ah Calculation Formula... 21 Table 8: Household Fire Ah Calculation Formula... 22 Bosch Security Systems 5/05 F01U003639B 3

D9412GV2/D7412GV2 Approved Applications Compliance Guide 1.0 Introduction 1.0 Introduction The UL System Chart (Table 2 on page 12) references the components that are evaluated and listed by UL for compatibility with the control panel. These components meet the basic system requirements for the applicable standard. The System Wiring Diagrams, Issue A (Figure 5 to Figure on pages 13 to 18) show the relationship between the control panel and the accessory components referred to in Figure 5. 2.0 Optional Compatible Equipment UL Listed components not requiring evaluation for electrical compatibility can be used in many applications when installed according to the manufacturer s instructions. 2.1 Burglary Applications UL Listed burglary alarm sensors not requiring evaluation for electrical compatibility can be used in burglary applications. In some cases, a UL Listed interface module must be used with the sensors. Consult the individual component specification and installation documents to determine suitability. Test Weekly: UL Standard 23 requires a weekly test for residential burglary applications. 2.2 Bank Safe and Vault Applications The UL Listed Model 51 Bell and Model 4001-42 External Line Balancer (both made by Rothenbuhler) must be used for the bell and balanced line module in bank safe and vault applications. Modify the D88A Attack-Resistant Enclosure to meet UL Standard 681. Bell Test at Arming: UL Standard 365 requires a Bell Test at arming for bank safe and vault applications. 2.2.1 Control Panel Enclosure Requirements UL Standard 681 for Installation and Classification of Mercantile and Bank Burglary Alarm Systems requires foil lining or equivalent protection of the control unit enclosure. The D88A Attack-Resistant Enclosure does not have a foil lining, but acceptable protection is provided by mounting electronic vibration sensors inside the enclosure. Refer to Figure 1 on page 6. Do not use proximity alarms (capacitance) to protect the control panel enclosure. Install the same electronic vibration sensors in the D88A that are used to protect the safe or vault. Mount the Sentrol 5402, Potter EVD-S, or Arrowhead S-38 electronic vibration detection (EVD) system inside the D88A to meet the UL 681 requirements. Mount the EVD sensor directly inside the metal cabinet of the D88A as shown in Figure 1. Do not install the EVD sensor within 6.4 mm (0.25 in.) of the components or traces of the printed circuit assembly. Install and test the EVD sensor according to the manufacturer s instructions. 2.2.2 Battery Connections Using a D122 Dual Battery Harness, connect two 12 V, 7 Ah batteries in the control panel enclosure. Refer to Figure 1 for battery placement information. Use a separate D88A for the 12 V, 18 Ah batteries. When using a D122L Dual Battery Harness, wire the batteries in parallel and connect the harness to Terminals 4 and 5 of the control panel. Auxiliary power, limited to 300 ma for 72 h, is required for standby. 2.2.3 Transmitter For UL Listed Grade AA Safe and Vault Applications, connect a D8122 Derived Channel STU or UL Listed Grade AA Transmitter to the control panel. This combination of components creates an alarm response at the central station that is not easily defeated by field interference. 2.2.4 Bell Requirements Use the following Rothenbuhler bell and balanced line modules with the control panel: UL Listed Model 51 Bell UL Listed Model 4001-42 External Line Balancer Bell Test at Arming: UL Standard 365 requires a Bell Test at arming for bank safe and vault applications. 4 Bosch Security Systems 5/05 F01U003639B

D9412GV2/D7412GV2 Approved Applications Compliance Guide 2.0. 2.2.5 System Configuration Requirements The following configuration and programming options are required for UL Bank Safe and Vault Systems. Refer to the D9412GV2/D7412GV2 Control Panel Program Entry Guide (P/N: F01U003636) for programming information. Safe and Vault Protective Circuits To test the devices that protect the safe(s) or vault(s) without sounding the bell, specify the devices points as controlled zones and supervised for trouble conditions. Refer to Point Index in the D9412GV2/D7412GV2 Control Panel Program Entry Guide (P/N: F01U003636) for more information. Bell Configuration UL 365 requires the bell time to be 15 to 30 min. The Rothenbuhler 51 Bell provides selectable bell time through manipulation of its jumpers. Refer to the manufacturer s installation instructions for more information. In addition to the jumper settings inside the bell, you can activate the control panel for a bell time of 15 min. UL 365 requires a Bell Test at arming and must be enabled in control panel programming. Refer to Bell Parameters in the D9412GV2/D7412GV2 Control Panel Program Entry Guide (P/N: F01U003636) for more bell time and test programming information. Bell Test To enable the bell test feature, you enable an unused area of the control panel. Enable the bell test feature for the unused area only. Program Relay B as the area bell relay for the unused area. All pass codes that have authority to the safe or vault protection must be valid in this area. Program the area for a five-second exit delay. Refer to Figure 1 on page 6 for test connections. To complete the installation for this feature, connect the output to a D133 Relay Module. 2.2.6 Exit Delay The control panel s programmed maximum exit delay must not exceed 30 sec. Optional Compatible Equipment 2.2.7 Equipment Requirements D9412GV2 or D7412GV2 Control Panel Two (2) D126 12 V, 7 Ah batteries Two (2) D1218 12 V 18 Ah batteries Two (2) D88A Enclosures D122 Dual Battery Harness D122L Dual Battery Harness D133 Relay Module EVD System (Listed Safe/Vault) 2.2.8 Wiring the Rothenbuhler 51/4001-42 High Security Bell to the D9412GV2 or D7412GV2 Control Panel Wear ear protection when installing and testing the Rothenbuhler High Security Bell. Sound levels greater than 95 dba at 3 m ( ft) can occur 1. Remove all power from the control panel. 2. Use six-conductor 1.2 mm (18 AWG) shielded stranded wire between the control panel and the 51 Logic Board (located in the bell enclosure). 3. If you do not have a Silence switch, temporarily install a 1 Ω resistor across TB1-1 and TB1-6 on the 51 Logic Board. The resistor keeps the 51 s bell silent during the installation and alignment procedures. Also place a temporary wire jumper across the TB1-6 Bell Relay and TB1-7. Refer to Figure 2 on page 7 for wiring a Silence switch. 4. Mount the D88A s 4001-42 External Balanced Line Module and wire it to the 51 Logic Board using two-conductor 0.8 mm (22 AWG) cable. 5. Wire the 4001-42 to the control panel. Refer to Figure 2 and the Rothenbuhler installation manual. 6. Before supplying AC and DC power to the control panel and bell, ensure you are wearing ear protection. The bell sounds for 2 sec and then silences during power up. Bosch Security Systems 5/05 F01U003639B 5

D9412GV2/D7412GV2 Approved Applications Compliance Guide 2.0 Optional Compatible Equipment Figure 1: Rothenbuhler 51/4001-42 High Security Bell Wiring Configuration 1 2 3 1 0.64 mm (1/4 in.) minimum distance 4 5 6 7 8 9 9 + - + - 11 12 15 13 14 16 1 - Self-contained vibration sensor 2 - Control panel 3 - Accessory modules 4 - High line security module 5-4001-42 Balanced Line Module 6-51 Bell 7 - D133 Relay 8 - Zone input 9 - D126 Battery - D88A Enclosure 11 - D122L Battery Harness 12 - Proximity/control unit 13 - Normally open (NO) 14 - Normally closed (NC) 15 - End-of-line (EOL) resistor 16 - Safe 6 Bosch Security Systems 5/05 F01U003639B

. D9412GV2/D7412GV2 Approved Applications Compliance Guide 2.0 Optional Compatible Equipment Figure 2: Wiring the Rothenbuhler 51/4001-42 High Security Bell to the D9412GV2 or D7412GV2 Control Panel 4 1 6 5 7 1 13 2 3 2 9 3 6 4 RED ORG WHT BL K 7 12 8 1 2 3 6 3 11 9 N/O 1 COMM 1 N/C 1 X1 - X1+ 1-51 Logic Board 8 - Alarm zone input* 2-4001-42 External Line Balancing Module 9 - kω resistor 3 - D9412GV2 or D7412GV2 Control Panel - Optional Silence switch 4 - Alarm output 11 - D133 Relay Module 5 - Alternate alarm 12 - BBL In 4 6 - Common 13 - BBL Out 5 7 - +12 VDC 14 - Terminal TB1 Use Terminal 11, 13, 14, 17, 19, 20, or 22. (Select only one.) Bosch Security Systems 5/05 F01U003639B 7

D9412GV2/D7412GV2 Approved Applications Compliance Guide 2.0 Optional Compatible Equipment 2.3 Fire Applications UL Listed fire initiating devices not requiring electrical compatibility evaluation can be used in any application. For example, the four-wire smoke detectors, heat detectors, waterflow switches, and manual pull stations are suitable fire initiating devices. Consult the individual component specification and installation documents to determine suitability. 2.3.1 Four-Wire Smoke Detectors When using four-wire smoke detectors, install a suitable power supervision device according to the manufacturer s instructions. You can connect any number of four-wire smoke detectors to the 9000GV2 Series Control Panels (subject to available auxiliary power). The Reset Sensor command is available from the keypads when the Reset Sensor is enabled. Connect the smoke detectors to a suitable interface such as the D125B or D129, or to the D8127/D9127 Modules when used with a 9000GV2 Series Control Panel. Smoke detectors can also be connected to the on-board points to meet UL and NFPA requirements. When using four-wire smoke detectors, install a suitable power supervision unit according to the manufacturer s instructions. Refer to Section 2.3.5 Other Devices. 2.3.2 Two-Wire Smoke Detectors Two-wire smoke detectors connect to the control panel only through the D125B Powered Loop Interface. Twowire detectors must be evaluated for electrical compatibility, and be UL Listed for use with the control panel. Refer to Table 1 on page 9 for the twowire smoke detectors that are UL Listed for compatibility and the maximum number of detectors that can be connected to each loop of the D125B Powered Loop Interface Module. You can also consult the smoke detector manufacturer to determine if a particular smoke detector is UL Listed for use with the 9000GV2 Series Control Panels. The Reset Sensor command is available from the keypads when Reset Sensor is enabled. 2.3.3 Two-Wire Smoke Detector Specifications Voltage Range: 8.0 VDC to 14 VDC UL Compatibility Identifier: Type A The control panel does not support multiple detectors in alarm. The control panel is intended to handle detectors with optional features. Detectors from different manufacturers cannot be mixed on the same circuit. 2.3.4 NFPA Style A (Class B ) Circuit Loops A and B on the D125B Module are NFPA Style A (Class B ) initiating circuits suitable for connecting any fire alarm initiating device, including two-wire and four-wire smoke detectors. To connect initiating devices to on-board points (1 through 8) on the D9412GV2 or D7412GV2 Control Panel: Use a D125 or D125B Powered Loop Interface Module with any type of initiating device. Use a D129 Dual Class A (NFPA Style D) Initiating Circuit Module with any type of initiating device, except a two-wire smoke detector. Use the following guidelines when connecting fire alarm initiating devices to off-board points: Do not connect two-wire smoke detectors to POPITs or MUX bus inputs. Use the D8127U, D8127T, D9127U, or D9127T POPIT Modules to connect four-wire smoke detectors when using a D9412GV2 or D7412GV2. 2.3.5 Other Devices Other initiating devices, including four-wire smoke detectors, connect to the control panel through the D129 Dual Class A Initiation Circuit Module, the D125B Powered Loop Interface, D8127 or D9127 POPITs, or on-board points. When using four-wire smoke detectors, install a suitable power supervision unit according to the manufacturer s instructions. Use the D130 Relay Module, D8129 OctoRelay Module, or Terminal 8, Switched Aux Power to provide reset capability. Refer to Off-Board Relays in the D9412GV2/D7412GV2 Operation and Installation Guide (P/N: F01U003641). For battery calculations, refer to Table 4 on page 20 and Section 8.0 NFPA 72 Fire Alarm Applications on page 21. Test Weekly: Perform a Fire Test weekly. Both the AC power and battery are tested according to UL 864. 8 Bosch Security Systems 5/05 F01U003639B

D9412GV2/D7412GV2 Approved Applications Compliance Guide 2.0 Optional Compatible Equipment. 2.3.6 UL Listed Two-Wire Smoke Detectors Compatible with the D125 or D125B A D125 or D125B Powered Loop Interface Module is required to connect smoke detectors to the on-board points (1 to 8). Table 1: UL Listed Two-Wire Smoke Detectors Compatible with the D125 or D125B Modules Manufacturer Detector Model Base Model Bosch Security Systems Radionics Detection Systems Honeywell D262 D281 D282 D283 D262 D281 D282 D283 DS200 DS200HD DS250 DS250TH DS282 DS282TH TC805C-00 TC804C-01 TC804C-19 System Sensor 1400 2400 2400TH 1451DH D260 D280 D280 D280 D260 D280 D280 D280 MB200-2W MB200-2W MB2W, MB2WL MB2W, MB2WL 14506587 and 14506587-004 14506587 and 14506587-004 14506587 and 14506587-004 DH400 20 20 Maximum Number of Detectors per Loop D125 D125B 12 VDC 12 VDC 24 VDC 25 25 20 20 80 80 80 80 80 80 60 60 40 40 40 40 40 40 40 Bosch Security Systems 5/05 F01U003639B 9

D9412GV2/D7412GV2 Approved Applications Compliance Guide 2.4 Enclosures Bosch Security Systems offers three optional enclosures for the control panel: D83 Enclosure The D83 is suitable for residential fire and burglary installations and commercial burglary applications that do not require attack resistance or the approval by Factory Mutual (FM) or New York City Materials and Equipment Acceptance (NYC-MEA). Refer to Table 2 on page 12 for acceptable applications. D88A Enclosure The D88A is attack resistant and intended primarily for UL commercial burglar alarm and mercantile safe and vault applications requiring a local bell. This enclosure can be used in any burglar or fire alarm application where the D89 Enclosure is suitable. The D88A, with some modification, can be used for bank safe and vault applications as described in Section 2.2 Bank Safe and Vault Applications on page 4. UL lists the D88A for all commercial fire alarm applications. It is approved by FM, CSFM, and the NYC-MEA. D89 Red Fire Enclosure Generally, the D89 is used for fire alarm applications. UL lists the D89 for all commercial fire alarm applications. It is approved by FM, CSFM, and the NYC-MEA. All references to NFPA and related requirements are based on compliance with the NFPA 72, National Fire Alarm Code. Because installation specifications are generally based on a specific edition of a standard that was legally adopted by the authority having jurisdiction (AHJ), consult with the appropriate AHJ for confirmation. 3.0 UL/NFPA Compliant Installations To install a D9412GV2 or D7412GV2 that is UL and NFPA compliant, the following items must be included: D89 Red Fire Enclosure D192C or D192G Bell Supervision Module D928 Dual Phone Line Module D8004 Transformer Enclosure Ground Fault Detect enabled on the control panel Refer to Table 2 for specific application installation requirements. Bosch Security Systems 5/05 F01U003639B

YEL RED ON when PHONE RED communicating LED OFF when idle PHONE LINE SEIZED TIP RING GRN. D9412GV2/D7412GV2 Approved Applications Compliance Guide 4.0 4.0 Ground Fault Detect Enable To enable the Ground Fault Detect Enable feature: 1. Lock (close) the S4 Ground Fault Detect Pin on the control panel as shown in Figure 3. 2. Program the Area 5 Silent Alarm Relay to a nonzero value (1 to 128). In remote programming software (RPS), the Area 5 Silent Alarm Relay is located in RELAY PARAMETERS, Area Wide Relays, and Silent Alarm Area 5 as shown in Figure 4. Figure 3: F01U003643B LEDs Off When Normal Ground Fault Detect (S4) Ground Fault Detect Enable Charging Status SDI Connector Digital Alarm Communicator Transmitter Low Battery - 12.1 VDC Refer to D9412GV2/D7412GV2 Approved Applications Compliance Guide (P/N: F01U003639 ) Reset Pin For System Wiring Diagram, Issue A Disable All Except Battery Charging And Programming Reset Pin Disable all except Battery.2 VDC - Battery Load Shed Refer to D9412GV2/D7412GV2 Approved Applications Compliance Guide (P/N: F01U003639 ) Charging and Programming For Compatible Smoke Detectors POWER SUPPLY REQUIREMENTS PERIPHERAL DEVICE CONNECTIONS CLASS 2 TRANSFORMER The Power Supply provides a maximum of 1.4 Amps for the Control Panel and all RED POWER + 16.5 VAC 40 VA 60 Hz Accessory Devices. For System Loading, refer to D9412GV2/D7412GV2 Model D1640 Operation and Installation Guide (P/N: F01U003641 ). Internally Fused - Do not short Requires Unswitched Outlet All external connections except Terminal 5 (battery positive) are inherently power YELLOW DATA BUS A Do not share with other equipment limited. Requirements for battery standby time might reduce allowable output. CAUTION: See D9412GV2/D7412GV2 Operation and Installation Guide + AUX POWER GREEN DATA BUS B (P/N: F01U003641) for Power Requirements relating to Terminals 6 and 7. BATTERY NEGATIVE ONLY WARNING! CAUTION: Avoid damage to Panel. Multi-Battery installation requires Battery: Replace every 3 to BLACK COMMON Do not connect 24 V to terminals. Model D122/D122L Dual Battery 5 years with one or two Model Maximum charging current 1.4 A Harness. Improper installation can D126 12V 7Ah or D1218 N.F.P.A. BATTERY POSITIVE ONLY ZONEX OUT 1 be a fire hazard. 12V 18Ah Lead Acid Batteries. Style 3.5 Signaling This equipment should be installed in accordance with the NFPA 70 (National Electrical Code) Line RELAY A PROGRAMMABLE 27 ALARM OUTPUTS and NFPA 72 (National Fire Alarm Code) for Local, Central Station, Remote Station, Proprietary and Circuits ZONEX IN 1 Household Fire Warning Systems and under the limits of the Local Authority Having Jurisdiction Terminals (National Fire Protection Association, Battermarch Park, Quincy, MA 02269). Printed information 26 RELAY B 6 and 7 describing proper installation, operation, testing, maintenance, evacuation planning and repair ZONEX OUT 2 26 SWITCHED AUX service is to be provided with this equipment. Terminal D9412GV2 Control/Communicator is UL Listed For Central Station, Local, Remote Station and 25 RELAY C ZONEX IN 2 25 8 Household Fire Alarm, and Central Station, Local, Police Station Connect, Household Burglar Alarm and Encrypted Line Security when communicating via a network. System is intended to be checked by a Qualified Technician at least every 3 years. 2 24 COMMON The types of initiating circuits the panel has been approved for are A, M, W, SS. ZONEX POWER + 24 VOLTAGE RANGES Open 3.7-5.0 VDC EARTH GROUND ZONEX COMMON 23 Normal 2.0-3.0 VDC Short 0.0-1.3 VDC GROUND FAULT DETECT PROG Point 1 Point 2 Point 3 Point 4 Point 5 Point 6 Point 7 Point 8 Enabled Point 8 D5200/D5360 CONN PROG CONN Disabled S3 Option Closed = 1KΩ EOL Normal Operation Open =AB-12 UL Bell Box 220 KΩ TELCO CORD MODEL D161 11 12 13 D9412GV2 14 15 16 17 18 19 20 21 22 1 1 - Locked (Closed) 2 - Unlocked (Open) Figure 4: Area 5 Silent Alarm Relay in RPS For more information, refer to the D9412GV2/D7412GV2 Operation and Installation Guide (P/N: F01U003641) and the D9412GV2/D7412GV2 Program Entry Guide (P/N: F01U003636). Bosch Security Systems 5/05 F01U003639B 11

D9412GV2/D7412GV2 Approved Applications Compliance Guide 5.0 Compatible UL Listed Components 5.0 Compatible UL Listed Components Table 2: UL Listed Components Compatible with the D9412GV2 and D7412GV2 Control Panels Household Burglary Household Fire Household Fire/ Burglary Combined Minimum Hours of Standby Battery 4 24 + 4 min alarm Central Station Burglary (Grade C) Police Connected Burglary Local Burglary Remote Station or Auxiliary Fire 4 4 4 60 + 5 min alarm Local Fire/Burglary Combined Local Fire 24 + 5 min alarm D83 Enclosure Choose one. No No No No No No No No No No D88A Enclosure The D1 lock is required for Req. Req. Choose Req. Choose one. the enclosure. D89 Enclosure No No one. No D122 and D122L Dual Battery Harness D125B Class B, Style A Powered Loop Interface D129 Class A, Style D Initiating Module Calculate the current draw to determine if a second battery is required. Opt. # # Opt. Opt. Opt. # # Req. Local and Central Station Fire Combined Local and Central Station Fire/ Burglary (Grade C) Central Station Fire/ Burglary Combined Central Station Fire Electrically Actuated Transmitter Calculate the current draw to determine if a second battery is required. # The D125 and D129 are required to connect fire alarm initiating devices to Zones 1 to 8. The D125 provides two powered loops for connecting listed two-wire smoke detectors. The D129 provides two non-powered Class A initiating circuits. D126/D1218 Battery 1+ 1+ 1+ 1+ 1+ 1+ 2+ 1+ 1+ 1+ 1+ 1+ 1+ 1+ D127 Reversing Relay Opt. No Opt. Opt. Opt. Opt. No Opt. No No Opt. Opt. No No D928 Dual Phone Line Module Opt. Opt. Opt. Opt. Opt. Opt. Required for communication on two telephone lines and/or CPU watchdog function. D161 Telephone Cord Required to connect control panel to RJ31X telco block. D185 Auxiliary Interface Kit * D192A/D192C/D192G Class B, Style W Bell Circuit Supervision 2 Req. Required to connect the control panel to the RJ31X telephone block. Opt. Opt. Opt. Opt. Opt. Opt. Required for indicating circuits. Opt. Opt. Smoke Detector Base 1++ 1++ Opt. Opt. Opt. Opt. Opt. Opt. Opt. D268/D269H Independent Zone Optional. Only connect to Zones 1 to 8. Control Indicating Device 1+ 1+ 1+ Opt. ** ** 1+ 1+ 1+,** 1+ 1+ Opt. Opt. D461 Pull Station Optional. Might be required by job specifications or AHJ. D1255/D1260 Command Center 1+ 1+ 1+ 1+ 1+ 1+ 1+ 1+ 1+ 1+ 1+ 1+ Opt. D1256 Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. D1257 Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. D1640 Transformer Required for all applications. D8004 Transformer Enclosure Opt. Opt. Opt. Opt. Opt. Opt. Required. D8122 Derived Channel STU D8125 Class B, Style 3.5 POPEX Module Optional. Contact the telephone company for availability of derived channel service. Required for the D8127T/U and D9127T/U POPITs. D8125MUX Required for MUX devices. Refer to Section 7.1 D8125MUX on page 19. D8127T/U & D9127T/U Class B, Style A POPIT Modules Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. D8128D OctoPOPIT Opt. No Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. D8129 OctoRelay D8130 Release Module D8132 Battery Charger D9131A Parallel Printer Interface Optional. For remote annunciation of system functions. Optional. Refer to Table 4 on page 20 to determine if the system requires a D8132 Module for increased battery standby. Optional. Use with the parallel printer to print events from the control panel log locally. D92B Access Control Interface No No No Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. No No = Not acceptable for this application. Req. = Required for this application. Opt. = Optional for this application. # The D125B and D129 are required to connect fire alarm initiating devices to Zones 1 to 8. The D125B provides two powered loops for connecting listed two-wire smoke detectors. The D129 provides two non-powered Class A initiating circuits. 1+ = One or more required for this application. Consult the appropriate standard. 2+ = Two or more required for this application. Consult the appropriate standard. 1++ = At least one detector required. You can substitute other two-wire detectors listed for use with the D125. You can also use the D262 with the D270 four-wire base and a listed power supervision relay. * = Auxiliary requires the D184 Auxiliary Local Energy Interface Kit. ** = Listed bell (siren) housing required for burglary alarm bell or siren. [Empty Box] = Not used for this application. 12 Bosch Security Systems 5/05 F01U003639B

RED. D9412GV2/D7412GV2 Approved Applications Compliance Guide 6.0 6.0 System Wiring Diagrams, Issue A System Wiring Diagrams, Issue A The System Wiring Diagrams, Issue A (Figure 5 on page 13 to Figure on page 18) show the relationship between the control panel and the accessory components referred to in Table 2 on page 12). 6.1 D9412GV2 Wiring Diagrams Figure 5: D9412GV2 System Wiring Diagram, Power Supply Side D113 BAT 2- CHGR- BAT 2+ BAT 1- BAT 1+ VAUX+ SUPV CHGR+ - + D126 or D1218 - + D126 or D1218 D1640 16.5 V, 40 VA 60 Hz Transformer - + - + D8132 Battery Charger D126 or D1218 D126 or D1218 1 2 3 CLASS 2 TRANSFORMER 16.5 VAC 40 VA 60 Hz Model D1640 Internally Fused - Do Not short Requires Unswitched Outlet Do Not Share With Other Equipment + AUX POWER D9412GV2 D126 Battery 12 V, 7 Ah or D1218 12 V, 17.2 Ah or 18.0 Ah D126 Battery 12 V, 7 Ah or D1218 12 V, 17.2 Ah or 18.0 Ah + D192C/D/G AUX PWR ALARM TRIG COM SUPV IN ALARM CKT - D928 4 5 6 7 8 9 BATTERY NEGATIVE ONLY Maximum Charging Current 1.4 Amps. BATTERY POSITIVE ONLY RELAY A RELAY B RELAY C COMMON EARTH GROUND PROGRAMMABLE ALARM OUTPUTS Terminals 7 & 8 Requires Optional Model D136 Relay In ALT ALARM & SW AUX GROUND FAULT DETECT Enabled Disabled ON when PHONE communicating LED OFF when idle PHONE LINE SEIZED Point 1 Point 2 Point 3 Point 4 Point 8 S3 Option Enabled: Closed = 1KΩ EOL Normal Operation Disabled: Open =AB-12 UL Bell Box 220 KΩ PROG CONN TIP TELCO RING 11 12 13 14 15 16 GRN C900 1 - If required by local AHJ, connect the D113 Battery Lead Supervision Module. 2 - D122 Dual Battery Harness, as required. 3 - D1640 Transformer and D8004 Transformer Enclosure required for NFPA applications 4 - D8132 Dual Battery Charger with two batteries (Batteries are not supervised). 5 - Power limited, supervised 6 - Power limited 7 - To Relay A or Relay B 8 - Listed audible signaling devices rated at.2 VDC to 13.8 VDC (Do not use vibrating type horns) 9 - Optional - 560 Ω, 2 W EOL resistor (P/N: 15-03130-005) 11 - RJ31X, secondary phone line 12 - RJ31X jack 13 - RJ31X, primary phone line 14 - To earth ground All external connections except Terminal 5 (battery positive) are power limited. Bosch Security Systems 5/05 F01U003639B 13

RED D9412GV2/D7412GV2 Approved Applications Compliance Guide 6.0 System Wiring Diagrams, Issue A Figure 6: D9412GV2 System Wiring Diagram, Input Points, and Peripheral Devices 1 2 3 CLASS 2 TRANSFORMER 16.5 VAC 40 VA 60 Hz Model D1640 Internally Fused - Do Not short Requires Unswitched Outlet Do Not Share With Other Equipment + AUX POWER D9412GV2 4 5 BATTERY NEGATIVE ONLY Maximum Charging Current 1.4 Amps. BATTERY POSITIVE ONLY 6 7 8 RELAY A RELAY B RELAY C PROGRAMMABLE ALARM OUTPUTS Terminals 7 & 8 Requires Optional Model D136 Relay In ALT ALARM & SW AUX 9 COMMON + - EARTH GROUND GROUND FAULT DETECT Enabled Disabled Point 1 Point 2 Point 3 Point 4 Point 5 Point 6 VOLTAGE RANGES Open 3.7-5.0 VDC Normal 2.0-3.0 VDC Short 0.0-1.3 VDC Point 7 Point 8 Point 8 S3 Option D5200/D5360 PROG CONN D130 TIP ON when PHONE communicating LED OFF when idle PHONE LINE SEIZED TELCO CORD MODEL D161 RING 11 12 13 14 15 16 17 18 19 20 21 22 Closed = 1KΩ EOL Normal Operation Open =AB-12 UL Bell Box 220 KΩ GRN PHONE LINE SEIZED TIP RING TELCO P5F P5BL D125B Sw. Aux Pwr 1 Zone B 2 Zone A 3 Pnl Common 4 Pnl Common 5 Loop B- 6 Loop A- 7 Loop B+ 8 Loop A+ 9 Earth Ground D129 Loop B+ Loop B- Loop B- Loop B+ Zone B Aux Power Earth Ground Common Zone A Loop A+ Loop A- Loop A- Loop A+ 1 2 3 4 5 6 7 8 9 11 12 13 1 - (Optional): For 24 V applications use a UL Listed 24 VDC power supply with a D130 Relay Module. Refer to the D130 Installation Instructions (P/N: 74-06262-000) for correct wiring requirements. 2 - D125B Powered Loop Interface Module 3 - To UL Listed two-wire smoke detectors. Refer to Section 2.3.2 Two-Wire Smoke Detectors on page 8 for a listing of compatible two-wire smoke detectors. 4 - P5 1 kω EOL resistor (P/N: 14-03130-004): Suitable for non-powered initiating and supervisory devices such as pull stations, heat sensors, and valve tampers. 5 - P5BL1 1kΩ EOL resistor: For typical burglar alarm applications. 6 - D129 provides optional Waterflow Alarm Retard feature. Not suitable for two-wire smoke detectors. Use zero retard except for waterflow devices. All external connections except Terminal 5 (battery positive) are power limited. 14 Bosch Security Systems 5/05 F01U003639B

. D9412GV2/D7412GV2 Approved Applications Compliance Guide 6.0 System Wiring Diagrams, Issue A Figure 7: D9412GV2 System Wiring Diagram, SDI Devices D1255 D1256 D1257 D1260 PERIPHERAL DEVICE CONNECTIONS RED POWER + 32 YELLOW DATA BUS A 31 GREEN DATA BUS B 30 BLACK COMMON 29 N.F.P.A. Style 3.5 Signaling Line Circuits ZONEX OUT 1 28 ZONEX IN 1 27 D92B D9131A ZONEX OUT 2 26 ZONEX IN 2 25 ZONEX POWER + 24 ZONEX COMMON 23 Point 8 S3 Option D5200/D5360 PROG CONN Closed = 1KΩ EOL Normal Operation Open =AB-12 UL Bell Box 220 KΩ D9133TTL-E GRN D8125 + - D8125 + - D8128D D8128D D8129 D8129 1 - Up to 8 supervised keypads 2 - Up to 8 D92Bs 3 - Up to 3 supervised D9131As 4 - Power limited, supervised 5 - Power limited 6 - POPEX 1 7 - POPEX 2 8- Up to 119 D9127U/T POPITs or up to 63 D8127U/T POPITs 9 - ZONEX 1: up to 15 D8128Ds - ZONEX 2: up to 15 D8128Ds maximum 11 - ZONEX 1: Up to 8 D8129s maximum 12 - ZONEX 2: Up to 8 D8129s maximum All external connections except Terminal 5 (battery position) are power limited. Bosch Security Systems 5/05 F01U003639B 15

D9412GV2/D7412GV2 Approved Applications Compliance Guide 6.0 System Wiring Diagrams, Issue A 6.2 D7412GV2 Wiring Diagrams Figure 8: D7412GV2 System Wiring Diagram, Power Supply Side D126/ D1218 D113 BAT 2- CHGR- BAT 2+ VAUX+ BAT 1- SUPV BAT 1+ CHGR+ D126/ D1218 D1640 16.5 V, 40 VA 60 Hz D8132 D126/ D1218 D126/ D1218 CLASS 2 TRANSFORMER 16.5 VAC 40 VA 60 Hz Model D1640 Internally Fused - Do Not short Requires Unswitched Outlet Do Not Share With Other Equipment + AUX POWER D7412GV2 BATTERY NEGATIVE ONLY Maximum Charging Current 1.4 Amps. BATTERY POSITIVE ONLY D126 Battery 12 V, 7 Ah/ D1218 12 V, 17.2 Ah or 18.0 Ah D126 Battery 12 V, 7 Ah/ D1218 12 V, 17.2 Ah or 18.0 Ah D192C/G AUX PWR ALARM TRIG COM SUPV IN ALARM CKT + - RELAY A RELAY B RELAY C COMMON EARTH GROUND GROUND FAULT DETECT Enabled Disabled PROGRAMMABLE ALARM OUTPUTS Terminals 7 & 8 Requires Optional Model D136 Relay In ALT ALARM & SW AUX Point 1 Point 2 Point 3 Point 4 D928 PHONE RED LED ON when communicating OFF when idle PHONE LINE SEIZED TIP TELCO RING 11 12 13 14 15 16 C900 1 - If required by local AHJ, connect the D113 Battery Lead Supervision Module. 2 - D122 Dual Battery Harness, as required. 3 - D1640 Transformer and D8004 Transformer Enclosure required for NFPA Applications 4 - D8132 Dual Battery Charger with two batteries (batteries are not supervised) 5 - Power limited, supervised 6 - Power limited 7 - To Relay A or Relay B 8- Listed audible signaling devices rated at.2 VDC to 13.8 VDC (Do not use vibrating type horns.) 9- Optional - 560 Ω, 2 W EOL resistor (P/N: 15-03130-005) 11- RJ31X, secondary phone line 12- RJ31X, jack 13- RJ31X, primary phone line 14- To earth ground All external connections except Terminal 5 (battery positive) are power limited. 16 Bosch Security Systems 5/05 F01U003639B

. D9412GV2/D7412GV2 Approved Applications Compliance Guide 6.0 System Wiring Diagrams, Issue A Figure 9: D7412GV2 System Wiring Diagram, Input Points, and Peripheral Devices CLASS 2 TRANSFORMER 16.5 VAC 40 VA 60 Hz Model D1640 Internally Fused - Do Not short Requires Unswitched Outlet Do Not Share With Other Equipment + AUX POWER D7412GV2 BATTERY NEGATIVE ONLY Maximum Charging Current 1.4 Amps. BATTERY POSITIVE ONLY RELAY A RELAY B RELAY C PROGRAMMABLE ALARM OUTPUTS Terminals 7 & 8 Requires Optional Model D136 Relay In ALT ALARM & SW AUX COMMON + - EARTH GROUND GROUND FAULT DETECT Enabled Disabled Point 1 Point 2 Point 3 Point 4 VOLTAGE RANGES Open 3.7-5.0 VDC Normal 2.0-3.0 VDC Short 0.0-1.3 VDC Point 5 Point 6 Point 7 Point 8 D130 ON when PHONE RED communicating LED OFF when idle PHONE LINE SEIZED TIP TELCO CORD MODEL D161 RING 11 12 13 14 15 16 17 18 19 20 21 22 PHONE LINE SEIZED TIP RING TELCO P5BL P5F D125B Sw. Aux Pwr 1 Zone B 2 Zone A 3 Pnl Common 4 Pnl Common 5 Loop B- 6 Loop A- 7 Loop B+ 8 Loop A+ 9 Earth Ground D129 Loop B+ Loop B- Loop B- Loop B+ Zone B Aux Power Earth Ground Common Zone A Loop A+ Loop A- Loop A- Loop A+ 1 2 3 4 5 6 7 8 9 11 12 13 1 - (Optional): For 24 V applications use a UL Listed 24 VDC power supply with a D130 Relay Module. Refer to the D130 Installation Instructions (P/N: 74-06262-000) for correct wiring requirements. 2 - D125B Powered Loop Interface Module 32 - To UL Listed 2-wire smoke detectors. Refer to the 9000/9000G/9000GV2 Series Technical Service Note: Smoke Detector Compatibility (P/N: 33284) for a listing of compatible two-wire smoke detectors. 4 - P5 1 kω EOL resistor: Suitable for nonpowered initiating and supervisory devices such as pull stations, heat sensors, and valve tampers. 5- P5BL1 1kΩ EOL resistor: For typical burglar alarm applications. 6 - D129 provides optional Waterflow Retard feature. Not suitable for two-wire smoke detectors. Use zero retard except for waterflow devices. All external connections except Terminal 5 (battery positive) are power limited. Bosch Security Systems 5/05 F01U003639B 17

RED TELCO RING D9412GV2/D7412GV2 Approved Applications Compliance Guide 6.0 System Wiring Diagrams, Issue A Figure : D7412GV2 System Wiring Diagram, SDI Devices D1255 D1256 D1257 D1260 CLASS 2 TRANSFORMER 16.5 VAC 40 VA 60 Hz Model D1640 Internally Fused - Do Not short Requires Unswitched Outlet Do Not Share With Other Equipment PERIPHERAL DEVICE CONNECTIONS RED POWER + YELLOW DATA BUS A + AUX POWER GREEN DATA BUS B BATTERY NEGATIVE ONLY Maximum Charging Current 1.4 Amps. BATTERY POSITIVE ONLY RELAY A RELAY B RELAY C PROGRAMMABLE ALARM OUTPUTS Terminals 7 & 8 Requires Optional Model D136 Relay In ALT ALARM & SW AUX BLACK NFPA Style 3.5 Signaling Line Circuits COMMON ZONEX OUT 1 ZONEX IN 1 D92B D9131A COMMON EARTH GROUND GROUND FAULT DETECT Enabled Disabled ON when PHONE communicating LED OFF when idle PHONE LINE SEIZED D9133TTL-E TIP D7412GV2 D8128D D8125 + - D8129 1 - Up to 8 supervised 2 - Up to 1 supervised 3 - Power limited, supervised 4 - POPEX 1 5 - Up to 67 D9127U/T POPITs or up to 63 D8127U/T POPITs 6 - ZONEX 1: Up to 8 D8128Ds 7- ZONEX 1: Up to 8 D8129s maximum All external connections except Terminal 5 (battery positive) are power limited. 18 Bosch Security Systems 5/05 F01U003639B

. D9412GV2/D7412GV2 Approved Applications Compliance Guide 7.0 Current Ratings Charts 7.0 Current Ratings Charts 7.1 D8125MUX Complete the chart in Table 3 to determine the maximum currents for the D8125MUX and its accessories. Transfer the total figures to Table 4 on page 20. The maximum current draw for each MUX Bus is 75 ma. Table 3: Current Rating Chart for D8125MUX AC Power Off Maximum Current (ma) In Alarm Maximum Current (ma) Accessory Module Qty. Used Each Unit Qty. Total System Each Unit Qty. Total System DS7432 x Qty. = x Qty. = DS7457i 0.35 x Qty. = 0.35 x Qty. = DS7460i 1 x Qty. = 1 x Qty. = DS7465i 1 x Qty. = 1 x Qty. = Ratings of other devices on the MUX Buses that are not shown above*: * Refer to the device s installation guide for current draw values. Column A Total = Column B Total = Bosch Security Systems 5/05 F01U003639B 19

D9412GV2/D7412GV2 Approved Applications Compliance Guide 7.0 Current Ratings Charts 7.2 Standby Battery Calculations Table 4: Current Rating Chart for Standby Battery Calculations Model Number D9412GV2/ D7412GV2 Qty. Used A B C AC Power On Normal Current (ma) Each Qty. Total Unit* AC Power Off Minimum Current (ma) Each Qty. Total Unit* In Alarm Maximum Current (ma) Each Qty. Total Unit* 225 x 1 = 225 225 x 1 = 225 300 x 1 = 300 D125B 22 x Qty = 22 x Qty = 150 x Qty = D127 5 x Qty = 5 x Qty = 55 x Qty = D129 22 x Qty = 22 x Qty = 23 x Qty = D185 245 x Qty = 245 x Qty = 300 x Qty = D192C 25 x Qty = 25 x Qty = 50 x Qty = D192G 35 x Qty = 35 x Qty = 0 x Qty = D1255 4 x Qty = 6 x Qty = 206 x Qty = D1256 4 x Qty = 6 x Qty = 206 x Qty = D1257 4 x Qty = 6 x Qty = 206 x Qty = D1260 200 x Qty = 200 x Qty = 250 x Qty = D720 20 x Qty = 20 x Qty = 0 x Qty = D8125 50 x Qty = 50 x Qty = 50 x Qty = D8125MUX 1 = = = D8127T/U 3 x Qty = 3 x Qty = 4 x Qty = D8128D 51 x Qty = 51 x Qty = 51 x Qty = D8129 20 x Qty = 20 x Qty = Refer to footnote 2 = D8130 7 x Qty = 7 x Qty = 60 x Qty = D9127T/U 0.5 x Qty = 0.5 x Qty = 0.8 x Qty = D9131A 21 x Qty = 21 x Qty = 23 x Qty = D92B 1 x Qty = 1 x Qty = 1 3 x Qty = D928 18 x Qty = 18 x Qty = 0 x Qty = DX40i 50 x Qty = 50 x Qty = 55 x Qty = DX4020i 80 x Qty = 80 x Qty = 84 x Qty = Ratings of other devices in the system that are not shown above: x Qty = x Qty = x Qty = x Qty = x Qty = x Qty = x Qty = x Qty = x Qty = x Qty = x Qty = x Qty = x Qty = x Qty = x Qty = Total A = Total B = Total C = 1 2 Refer to Table 3 on page 19 to determine maximum currents for the D8125MUX and its accessories. The In Alarm calculation for the D8129 is: 20 x Qty + 22.5 x number of relays 3 Use 1 ma + reader current. Do not exceed 260 ma. 20 Bosch Security Systems 5/05 F01U003639B

D9412GV2/D7412GV2 Approved Applications Compliance Guide 8.0 NFPA 72 Fire Alarm Applications. 8.0 NFPA 72 Fire Alarm Applications Table 5: Standby Battery Requirements Type Required Capacity Calculations Household Burglary and Commercial Burglary Bank Safe and Vault Central Station or Local Fire Alarm Remote Station or Auxiliary Fire Alarm Household Fire Warning Equipment 4 h 72 h (UL 365). Auxiliary power current for all devices, including keypads, must be limited to 300 ma or less to meet this requirement. 24 h + 5 min of alarm operation. Refer to Table 6. 60 h + 5 min of alarm operation. Refer to Table 7. 24 h + 4 min of alarm operation. Refer to Table 8 on page 22. 8.1 Standby Battery Calculation for NFPA 72 Fire Alarm Applications Refer to Table 3 on page 19 for totals B and C used in the formulas below. When connecting two batteries, use either the D122 Dual Battery Wiring Harness or the D8132 Battery Charger Module. 8.2 Central Station or Local Systems Central Station or Local Systems require 24 h of standby plus 5 min of alarm operation at the end of the 24-hour period. A single battery is sometimes adequate for central station systems, but two batteries must be installed to meet the basic standby requirements for a local system installation. Use the battery ampere-hour (Ah) calculations to confirm compliance. The formula in Table 6 includes the calculation for 5 min of alarm operation at the end of the 24-hour period, as well as a % contingency factor that allows for depletion of battery capacity with age. Table 6: Central Stations or Local Systems Ah Calculation Formula Total B Hours Total C Hours Contingency Total Ah* ( x 24 ) + ( x.083) + % = *Total Ah requirements must not exceed Ah capacity of batteries: two D126 Batteries = 14 Ah; one D1218 Battery = 17.2 or 18 Ah. 8.3 Remote Station or Auxiliary Systems Remote Station or Auxiliary Systems require 60 h of standby plus 5 min of alarm operation at the end of the 60-hour period. A D8132 Battery Charger Module with additional batteries installed in a separate D89 or D88A Enclosure might be required in the system to meet the basic standby requirements for a remote station or auxiliary system installation. Use battery Ah calculations to confirm compliance. The formula in Table 7 includes the calculation for 5 min of alarm operation at the end of the 60-hour period, as well as a % contingency factor that allows for depletion of battery capacity with age. Table 7: Remote Station or Auxiliary Systems Ah Calculation Formula Total B Hours Total C Hours Contingency Total Ah* ( x 60 ) + ( x.083) + % = *Total Ah requirements must not exceed Ah capacity of batteries: two D126 Batteries = 14 Ah; one D1218 Battery = 17.2 or 18 Ah. Bosch Security Systems 5/05 F01U003639B 21

D9412GV2/D7412GV2 Approved Applications Compliance Guide 8.0 NFPA 72 Fire Alarm Applications 8.4 Household Fire Warning Equipment The Household Fire Warning Equipment Standard requires 24 h of standby current plus 4 min of alarm operation at the end of the 24-hour period. Use battery Ah calculations to confirm compliance. The formula in Table 8 includes the calculation for 4 min of alarm operation at the end of the 24-hour period, as well as a % contingency factor that allows for depletion of battery capacity with age. Table 8: Household Fire Ah Calculation Formula Total B Hours Total C Hours Contingency Total Ah* ( x 60 ) + ( x.067) + % = *Total Ah requirements must not exceed Ah capacity of batteries: two D126 Batteries = 14 Ah; one D1218 Battery = 17.2 or 18 Ah. 22 Bosch Security Systems 5/05 F01U003639B

. D9412GV2/D7412GV2 Approved Applications Compliance Guide 8.0 Notes NFPA 72 Fire Alarm Applications Bosch Security Systems 5/05 F01U003639B 23

Bosch Security Systems 130 Perinton Parkway Fairport, NY 14450-9199 Customer Service: (800) 289-0096 Technical Support: (888) 886-6189 2005 Bosch Security Systems F01U003639B