Installation Plan Commercial Rotary Iron PM 1210 PM 1214 PM 1217

Similar documents
Tumble dryer PT 5136 PT en - GB. Installation plan

Operating instructions Rotary iron HM

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

Installation plan PG 8581 PG 8582 PG en - US

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

Installation Specifications Laundry Care System

PM 12 series rotary ironers. The New PM 12 Rotary Ironers: Best Ergonomics, Simple Operation, Perfect Laundry Finish

Installation Plan Washing Machine PW 811 PW 814 PW 818

Installation Plan. Laboratory Glassware Washer. en US PG 8583 CD. M. Nr

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

Tumble dryer PT 5135 C PT 7135 C. en - GB. Installation plan

Operating instructions for the DA 8-2 Extractor

INSTALLATION INSTRUCTIONS TD75. Vented tumble dryer DOMESTIC. Carefully read the instructions for use before using the dryer.

Installation instructions for vented tumble dryer DOMESTIC. Dear Customer,

Installation manual. Tumble dryers T4130. Compass Control

Installation instructions for the T 9820 Gas Dryer

Washing machine PW 5064 MOPSTAR 60. en - GB. Installation plan

Product Dimensions Large Capacity Vented Dryers Flat Controls T8002

28 1/2"* 72.4 cm. (*28 1/2 " to include hinges.) 41 3/4" 106 cm. 27" 68.6 cm. 28 1/2"* 72.4 cm. (includes hinges.) 28 1/2"* 41 3/4" 106 cm

Section 9 - Tumble Dryers. Tumble Dryers LEPH

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

Washing machine PW 6055 AV/LP PW 6065 AV/LP. en - GB. Installation plan

Installation plan Commercial Washing Machine PW 413 PW 418

Product overview Laundry machines. Washing, Drying, Ironing Thorough, gentle and efficient laundry care

W6324. ASKO Laundry Care

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

Product Dimensions Large Capacity Vented Dryer Angled control T8003 / T8005

en-gb Operating instructions Rotary ironer PM 1621 PM 1625 PM 1630 PM 1635 PM 1825 PM 1830 PM 1835

Installation of a Brunner fireplace. General Indications

Installation plan: PG Mat. no Version 00 US

ENERVEX RSV CHIMNEY FAN

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Installation manual. Tumble dryers T4290, T4530, T4650. Selecta Control

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

FD 90 / FD 95 Rotary Perforators

CHAPTER 5: EXHAUST SYSTEMS

Product Dimensions Page 1 of 7. DA Downdraft Ventilation Hood

Product Dimensions Large Capacity Vented Dryer Angled control T1515

TECHNICAL INFORMATION L / A 1

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

Tumble dryer PT 5137 WP PT 7137 WP. en - GB. Installation plan

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Cooker Hood User Manual

Professional Laundry Solutions

Table of contents. Planning guide for modular refrigerator, freezer and wine columns. Refrigeration 187. Installation options...

Installation manual. Tumble dryers T4250, T4350. Selecta Control

Operating and Installation Instructions

READ AND SAVE THESE INSTRUCTIONS

High Power Range Hood

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Installation Instructions

Planning and Design Guide 2002 Vrs 2.0

GLEB Kitchen exhaust fan

HEAT RECOVERY AIR HANDLING UNIT

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

Installation and Maintenance Manual Please retain this manual for future reference.

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

APPUZO RANGE HOOD INSTALLATION

Installation Instructions

Installation Instructions DAR 1150, DAR 1220 DAR 1230, DAR 1250

Product Information. Brushes. Drum brace cable

GETTING STARTED? EASY.

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Ventilation Fan Model VFB24ACTH VFB24ADTH VFB24AXTH

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Operating and Installation Instructions

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

Washing machines, tumble dryers and rotary ironers for professional use. Product overview

Operating instructions

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

Operating and Installation Instructions Ventilation Hood

Model No. PE2-07R / PE2-09R / 9000 BTU Portable Air Conditioner with dehumidifier & Fan PE2-07R-62 / PE2-09R-32 Operating Instructions

ENERVEX GSV GREASE FAN

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

Venting of Gas Fired Equipment RV

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

Caption Included option -- Not possible option a.a Available on request Recommended option

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

VENTILATION FAN WITH LIGHT AND HEATER

Dishwasher Installation Manual

IT025. Unmatched Industrial Reliability. Easy to Use Simplicity TUMBLE DRYER FOR ON-PREMISES LAUNDRY APPLICATIONS.

Operating Instructions & Parts Manual Models 99533, 99532

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

Home Stack Washer/Dryers

Models. Options. Standard Features. LoH 2 O

INSTRUCTIONS FOR USE TUMBLE DRYER

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

ECONOMIZER AWTM INSTALLATION, OPERATION, MAINTENANCE AND SERVICE MANUAL

JFT Flight Machine. JFT Flight Machine. Models. Options. Standard Features. JFT Flight Machine

SERVICE MANUAL T3900/T31200 TD100/TD135

Inspection Checklist Mechanical Final

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Home Stack Washer/Dryers

READ AND SAVE THESE INSTRUCTIONS

Fresh and clean... even when it isn't laundry time.

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

Transcription:

Installation Plan Commercial Rotary Iron PM 1210 PM 1214 PM 1217 To avoid the risk of accidents or damage to the machine, it is essential to read these instructions before it is installed and used for the first time. en - US M.-Nr. 09 981 760

Contents Notes for installer... 3 Installation... 3 Setting up the rotary iron... 4 Mounting the toe-kick (optional)... 4 Install the laundry box on the laundry outfeed table.... 4 Duct for venting steam... 4 Substitute duct lengths... 5 Maximum permissible total duct length... 5 Electrical connection... 6 Installation Plan... 7 Flatwork ironer PM 1210, PM 1214, PM 1217... 7 Technical details... 8 2

Notes for installer The rotary iron should be installed by a Miele trained installer. Storage of the machine The following conditions must be observed for transport and storage: Temperature: minimum of - 77 F / 25 C to maximum of 131 F / 55 C Humidity: minimum of 5% to maximum of 75%, non-condensing Maximum storage period: 2 years Operating conditions In general, the operating conditions of DIN 60204 and EN 60204-1 apply. Temperature and relative humidity Temperature: 40 F / 5 C - 104 F / 40 C Relative humidity: 10% - 85% At 70 F (21 C) ambient temperature, the maximum permissible relative humidity is 70%. Do not operate the machine in a room where cleaning machines operate with solvents containing PERC or CFC. Motor sparking may convert solvent vapors into hydrochloric acid which can lead to consequential damage. Installation The machine is transported to the installation site while still in the packaging. Do not remove the packaging until right before installation. The machine may be transported or lifted from the wooden frame only with the lateral mounting flaps mounted. First lift the machine at the installation site by the wooden frame. The suspension points for lifting hooks/straps are located under the side columns between the screwon feet. During installation, remember that the clearance next to and behind the machine columns must amount to at least 23 5/8" (600mm) so that the side plates remain accessible. The machine should be set up so that the light shines parallel to the infeed table as much as possible. The clearance in front of the machine must amount to at least 60" (1.5m) to prevent a heating of foreign materials (furniture, walls). There should be a clearance of at least 39" (1m) above the machine. A base and anchoring means are not necessary. During the transport of the machine, pay attention to its stability. The iron may not be transported without the wooden frame (e.g., in case of a move). For a new transport, lift the iron onto the wooden frame and fasten it there. 3

Notes for installer Setting up the rotary iron Dismantle the mounting flaps on the left and right sides. Check the roller and front and outside of the side columns using a level. Align the machine using the screw-on feet in such a way that the side columns and roller are level with each other. In the process, the feet may be unscrewed a maximum of 2 3/8" (60mm). Counter the screw-on feet according to the alignment using the nuts (under the side columns). Mounting the toe-kick (optional) Mounting the optionally available toe-kick can raise the machine by 4" (100mm). Dismantle the mounting flaps on the left and right sides. Unscrew the screw-on feet by the maximum amount (> 2 3/8" (60mm)). Hold the side columns with a suitable aid and remove the screw-on feet. Mount the screw-on feet into the toe-kick and push the toe-kick under the column. Screw the toe-kick to the base plate of the machine. Install the laundry box on the laundry outfeed table. During installation, bring the laundry shelf into a horizontal position. Loosen the fastening screws of the laundry shelf. Rotate the laundry box by 180 and mount with the fastening screws on the laundry outfeed table. Duct for venting steam Never connect an exhaust hood to an active chimney, dryer vent, flue, or room venting ductwork It must also be laid separately to any exhaust air duct used for a laundry dryer. The moist warm exhaust air must be vented to the outdoors by the shortest route possible. To ensure optimum air flow, the ducting should contain as few bends as possible and airtight connections. Filters and louvers may not be installed into the exhaust duct. Since the relative humidity can amount to up to 100%, suitable measures must be taken to prevent condensate from flowing back into the machine. If the available pressure of the machine fan for overcoming conductor resistance does not suffice, an according dimensioned additional fan must be installed in the shaft or roof outlet on-site. Ensure that there is sufficient ventilation in the room where the ironer is installed The connection for the exhaust air duct for steam extraction (optional for PM 1210) is located on the rear of the left side column and has a diameter of 2 3/4" (70mm). The exhaust air duct must have an internal diameter of 2 3/4" (70mm). To prevent the build-up of condensation in an upward sloping exhaust ducting, a 1/8" - 3/16" (3-5mm) ø condensate trap should be fitted at the lowest point. Ensure that there is sufficient ventilation in the room where the ironer is installed The on-site ducting system and the exit point to the outside must be checked on a regular basis for a build-up of lint and cleaned if required. The air duct leading into the open should be protected against the elements, e.g. using a suitable hood or grille or with a 90 bend. 4

Notes for installer Substitute duct lengths Molded part Substitute duct length PM 1210* PM 1214 PM 1217 90 bend r = 2 d 10" (0.25m) 45 bend r = 2 d 5 7/8" (0.15m) 90 bend r = d 13 3/4" (0.35m) 45 bend r = d 10" (0.25m) Maximum permissible total duct length Adequate room ventilation must be ensured during operation. Minimum inside duct diameter (sheet metal ducting) Maximum permissible total duct length Exhaust air PM 1210* PM 1214 PM 1217 2 3/4" (70mm) 16' 4 7/8" (5m) 3 1/8" (80mm) 65' 7 3/8" (20m) 3 9/16" (90mm) 104' 11 13/16" (32m) 4" (100mm) 131' 2 13/16" (40m) 90 creased bend 45 creased bend r = 2 d r = 2 d 27 9/16" (0.7m) 21 5/8" (0.55m) *Optional extraction fan Once the machine has been successfully installed and connected, replace all the external parts that were removed. 90 segmental bend (3 weld seams) r = 2 d 17 11/16" (0.45m) 45 segmental bend (3 weld seams) 90 bend made of flexible duct 45 bend made of flexible duct r = 2 d - r = d - r = 2 d 19 11/16" (0.5m) r = 4 d 13 3/4" (0.35m) r = d - r = 2 d 15 3/4" (0.4m) r = 4 d 11 13/16" (0.3m) According to the number of bends, the substitute duct lengths must be deducted from the maximum permissible duct length. 5

Notes for installer Electrical connection All electrical work must be performed by a qualified service technician in accordance with all applicable codes and standards. The electrical connection and wiring diagram are located behind the mounting flap of the right side column. The values for the electrical connection and fuse rating can be found on the data plate (see the "Technical data" chapter in this document). If the appliance is hard wired, a multiplepole separator must be installed. Separators with a contact gap of more than 1/8" (3 mm) are valid as separators. All components have to bear CSA or UL approval. The plug connection or the disconnector must be accessible at all times. You must be able to lock the disconnector or monitor the point of disconnection at all times in case the appliance has to be disconnected from the power supply. 6

Installation Plan Flatwork ironer PM 1210, PM 1214, PM 1217 Type of heating: electrical Measurements in inches * = Option for PM 1210 a Electrical connection b Exhaust connection 7

Technical details 53121005USA, PM 1210 EL USA 3AC 240/220/208V 50-60Hz 09/2014 Voltage Fuse rating Roller length Roller diameter Type of heating 3 AC 240/220/208V 50-60Hz 3 x 20 A 39 ³/₈" / 1000 mm 8 ⁸/₃₂" / 210 mm Electric Overall machine dimensions Width 61 ¹⁵/₁₆" / 1573 mm Minimum wall distance, lateral Minimum wall distance, rear Net weight Max. load bearing in operation Total connected load Heat output, electrical Drive output, roller Depth Height 18 ¹/₂" / 470 mm 40 ⁵/₈" / 1032 mm 23 ⁵/₈" / 600 mm 23 ⁵/₈" / 600 mm 269 lbs (122 kg) 1235 N 5.3/5.0/4.1 kw 4.9/4.1/3.7 kw Fan output - Electrical connection 0.35 kw 4 x AWG 10 / 4 x 4 mm² Exhaust air connection - Ironing output 56.2 lbs/h / 25.5 kg/h Roller Speed 2.3-6.1 rpm Outer circumference linear speed Contact pressure 4' 11" - 13' 1" fpm (1.5-4.0 m/min) 1.02 psi / 0.7 N/cm² Fan air output - Max. permitted pressure loss - Material Side columns Stove-finished, galvanized sheet steel Padding Material padding Largest removable part Heat dissipation rate at installation site Sound pressure level Sound power level Roller Heater plate Galvanized sheet steel Aluminium, hard-anodized Steel wool Polyester needle felt with aramid needle felt cloth Laundry outlet table 4.9/4.1/3.7 MJ/h 54 db (A) 60.6 db 8

Technical details 53121006USA, PM 1210 EL USA AC 240/220/208V 50-60Hz 09/2014 Voltage Fuse rating Roller length Roller diameter Type of heating AC 240/220/208V 50-60Hz 2 x 20 A 39 ³/₈" / 1000 mm 8 ⁹/₃₂" / 210 mm Electric Overall machine dimensions Width 61 ¹⁵/₁₆" / 1573 mm Minimum wall distance, lateral Minimum wall distance, rear Net weight Max. load bearing in operation Total connected load Heat output, electrical Drive output, roller Depth Height 18 ¹/₂" / 470 mm 40 ⁵/₈" / 1032 mm 23 ⁵/₈" / 600 mm 23 ⁵/₈" / 600 mm 269 lbs (122 kg) 1235 N 3.7/3.2/2.9 kw 3.3/2.7/2.5 kw Fan output - Electrical connection 0.35 kw 3 x AWG 10 / 3 x 4 mm² Exhaust air connection - Ironing output 49.6 lbs/h / 22.5 kg/h Roller Speed 2.3-6.1 rpm Outer circumference linear speed Contact pressure 4' 11" - 13' 1" fpm (1.5-4.0 m/min) 1.02 psi / 0.7 N/cm² Fan air output - Max. permitted pressure loss - Material Side columns Stove-finished, galvanized sheet steel Padding Material padding Largest removable part Heat dissipation rate at installation site Sound pressure level Sound power level Roller Heater plate Galvanized sheet steel Aluminium, hard-anodized Steel wool Polyester needle felt with aramid needle felt cloth Laundry outlet table 3.3/2.8/2.5 MJ/h 54 db (A) 60.6 db 9

Technical details 53121405USA, PM 1214 EL USA 3AC 240/220/208V 50-60Hz 09/2014 Voltage Fuse rating Roller length Roller diameter Type of heating 3 AC 240/220/208V 50-60Hz 3 x 30 A 55 ¹/₈" / 1400 mm 8 ⁹/₃₂" / 210 mm Electric Overall machine dimensions Width 77 ¹¹/₁₆" / 1973 mm Minimum wall distance, lateral Minimum wall distance, rear Net weight Depth Height 25 ⁵/₈" / 651 mm 40 ⁵/₈" / 1032 mm 23 ⁵/₈" / 600 mm 23 ⁵/₈" / 600 mm 309 lbs (140 kg) Max. load bearing in operation 318 lbs (1415 N) Total connected load Heat output, electrical Drive output, roller Fan output Electrical connection Exhaust air connection Ironing output 7.6/6.5/5.9 kw 7.1/6.0/5.3 kw 0.35 kw 0.11 kw 4 x AWG 10 / 4 x 4 mm² 2 3/4" (70 mm) 62 lbs/h (28 kg/h) Roller Speed 2.3-6.1 rpm Fan air output Max. permitted pressure loss Outer circumference linear speed Contact pressure 4.9-13.1 fpm (1.5-4.0 m/min) 0.10 psi (0.7 N/cm²) 67.7 cfm (115 m³/h) 0.01 psi (100 Pa) Material Side columns Stove-finished, galvanized sheet steel Padding Material padding Largest removable part Heat dissipation rate at installation site Sound pressure level Sound power level Roller Heater plate Galvanized sheet steel Aluminium, hard-anodized Steel wool Polyester needle felt with aramid needle felt cloth Laundry outlet table 7.1/5.9/5.3 MJ/h 54 db (A) 60.6 db 10

Technical details 53121705USA, PM 1217 EL USA 3AC 240/220/208V 50-60Hz STW 09/2014 Voltage Fuse rating Roller length Roller diameter Type of heating 3 AC 240/220/208V 50-60Hz 3 x 50 A 65 3/8" (1660 mm) 9 13/16" (250 mm) Electric Overall machine dimensions Width 87 15/16" (2233 mm) Minimum wall distance, lateral Minimum wall distance, rear Net weight Depth Height 26 5/8" (651 mm) 43 11/16" (1110 mm) 23 5/8" (600 mm) 23 5/8" (600 mm) 417 lbs (189 kg) Max. load bearing in operation 428 lb (1905 N) Total connected load Heat output, electrical Drive output, roller Fan output Electrical connection Exhaust air connection Ironing output 12.4/10.5/9.4 kw 11.8/9.9/8.9 kw 0.4 kw 0.11 kw 4 x AWG 8 / 4 x 6 mm² 2 3/4" (70 mm) 110 lbs/h (50 kg/h) Roller Speed 1.9-5.7 ¹/min Fan air output Max. permitted pressure loss Outer circumference linear speed Contact pressure 1.5-4.5 m/min 0.5 N/cm² 67.7 cfm (115 m³/h) 0.01 psi (100 Pa) Material Side columns Stove-finished, galvanized sheet steel Padding Material padding Largest removable part Heat dissipation rate at installation site Sound pressure level Sound power level Roller Heater plate Galvanized sheet steel Aluminium, hard-anodized Steel wool Polyester needle felt with aramid needle felt cloth Laundry outlet table 9.0/11 MJ/h 54 db (A) 59.7 db 11

Please have the model and serial number of your appliance available before contacting Technical Service. U.S.A. Miele, Inc. National Headquarters 9 Independence Way Princeton, NJ 08540 Phone: 800-991-9380 609-419-9898 Fax: 609-419-4241 www.mieleusa.com Technical Service & Support Nationwide Phone: 800-991-9380 Fax: 800-220-1348 proservice@mieleusa.com Alteration rights reserved / Publication date: 3814 M.-Nr. 09 981 760 / 01