Problems Air and Water Distribution Systems

Similar documents
Challenges and Methods of Estimating a Conceptual HVAC Design

Underfloor Air Distribution:

City of Duluth Festival Center 04/25

Displacement Ventilation

Chapter 14, Problem 27.

DACC Health Sciences Building Air Handler Assessment/Study

4. OVERVIEW OF MECHANICAL SYSTEM

Linear Floor Heaters

GARCIA GALUSKA DESOUSA Consulting Engineers

Raised Access Floor - (AE Breadth Area)

CHAPTER IV AIR DISTRIBUTION AND BALANCE

EFFICIENT DUCT SYSTEM DESIGN

ASHRAE JOURNAL ON REHEAT

Architectural Engineering Senior Thesis Mechanical System Redesign

HVAC OUTDOOR AIR VENTILATION STANDARD. ASHRAE Standard ASHRAE Standard

Technical Assignment 3 11/15/04. Executive Summary

Active Chilled Beams

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

Engineering Guide VAV Diffusers. Please refer to the Price Engineer s HVAC Handbook for more information on VAV Diffusers.

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

ADDENDUM No: 3 JOSEPHINE COUNTY BUILDING OPERATIONS DEPARTMENT. February 29, NO CHANGE: March 8, 2012 / NOT LATER THAN 2:00 PM

Development of a Psychrometric Test Chamber. Michael J. Swedish. Associate Professor Mechanical Engineering Department Milwaukee School of Engineering

Rittling Induction Units Catalog

DIVISION 15 MECHANICAL

DESIGNING MODULAR VAV SYSTEMS

DESCRIPTION OF TECHNOLOGY

HVAC DISTRIBUTION and DELIVERY SYSTEMS

Don t Turn Active Beams Into Expensive Diffusers

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

HE-B Series Commissioning Report & User Guide

1.1 This section applies to air handling units for HVAC Systems.

Ventilation. ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce.

SECTION HVAC TABLE OF CONTENTS PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS FILED SUB BID PROJECT OVERVIEW...

OSU Alumni Center Phase I Implementation Review. Oregon State University 130 Oak Creek Bldg. Corvallis, Oregon

APPLICATION GUIDE BEAMS

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Modular Active. Chilled. Beams

Units for suspended ceilings Type DID632

CAT-SIUH-2000(3) SUPERSEDES CAT-SIUH-98(2) SARAVEL INDUSTRIAL UNIT HEATERS

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

Urbana Free Library HVAC Analysis. Prepared for the Urbana Free Library. Prepared by Paul Boland, P.E., and Nathan Alderman, E.I.T.

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

Job Name Control Systems Description Date

SECTION PLUMBING/HVAC FINAL TESTING, ADJUSTING AND BALANCING

Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards 2013 Residential Compliance June 2014

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

CE311 Fall 2016 Mid-Term Exam 1

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

CE311 Fall 2016 Mid-Term Exam 1

University of Illinois Business Instructional Facility LEED Gold Design. University of Illinois Business Instructional Facility

KLIMA Active Chilled Beams

Fan Selection. and Energy Savings

SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

DIVISION 23 - HVAC HVAC Air Distribution

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

SECTION AIR COILS

Caice Attenuator Selector - Specifier Edition

Computing Services Center

Appendix 13. Categories of Cooling and Heating systems

Chilled Water DOAS Fan Powered Terminal Units

DUCT SYSTEMS CHAPTER 6

AIRSIDE COMPONENTS AND SYSTEMS

TESTING, ADJUSTING AND BALANCING

DIVISION 23 - HVAC HVAC Air Distribution

Product Data. 40RUA/40RUS 6to15TonDirectExpansion 7.5to15TonChilledWater Packaged Air---Handling Units FEATURES/BENEFITS. Indoor air quality features

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

Variable Refrigeration Flow Systems Overview 10/11/2016

CITY OF DANA POINT. COMMUNITY DEVELOPMENT, BUILDING AND SAFETY Golden Lantern, Suite 209 Dana Point, CA

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

FCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual

Notable Changes in the Mechanical Codes

EADQUARTERS. Technical Report One. Stephanie Kunkel Mechanical Option

Air Conditioning Options Winnetka Public School District 36 Winnetka, Illinois November 4, 2016

PDH & Professional Training

Madeira City Schools Madeira, Ohio. HVAC Assessment. December 2011 (Revised February 2012)

HVAC 101. H V A C S y s t e m s

The Current (2017) State of the Art for Air Leakage in Ductwork

7. MECHANICAL SYSTEM DESIGN

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC

Type VDW WITH LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH INDIVIDUALLY MANUALLY ADJUSTABLE AIR CONTROL BLADES

In the past, contractors sized heating and cooling systems GETTING HVAC RIGHT

Performance Rating of Variable Refrigerant Flow (VRF) Multi-split Air-conditioning and Heat Pump Equipment

Appendices. Included in this section are

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

IDL20e (2 way discharge) IDS60e (4 way discharge) Inffusers. UDI (vertical discharge) Frequently Asked Questions

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

Fan Power in 90.1 & IECC

Air Handler Unit (AHU) Equipment Purchase and Delivery Invitation to Bid

Dates of Construction Construction Start 2/28/1999 Date of Completion 4/2000 Occupancy 5/2000

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

Design Standard. Thermal Systems (Chilled Water and Hot Water Systems) Detailed specifications follow. CHW AND HHW SUPPLY TEMPERATURE RESET

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Centeral Station Air Handling Unit

Transcription:

Problems Air and Water Distribution Systems ME419 D. Abata 1. Cooled air at 1 atm, 50 F, and 10% relative humidity is transported in a 600 ft long circular sheet metal duct at a rate of 800 cfm. If the head loss is not to exceed 1.5 inches of water, determine the minimum diameter of the duct. You may assume the inside surface of the duct is smooth (ε/d 0). 2. Heated air at 1 atm, 100 F, and 40% relative humidity is transported in a 300 ft long rectangular sheet metal duct at a rate of 400 cfm. If the head loss is not to exceed 1 inch of water, recommend the size of the rectangular duct. 3. A design engineer wishes to select an appropriate fan for the following galvanized steel duct system. Estimate the pressure loss for each branch of the duct system. 4. The duct system shown is one branch of a complete low-velocity air distribution system. The system is a perimeter type, located below the finished floor. The diffuser boots are shown, complete with the pressure losses. Design a round duct system, bearing in mind that a total pressure of 0.21 in. wg is available at the plenum.

5. A draw-through air-handling unit (AHU) will be used to supply conditioned air as shown in the schematic drawing below. Within the AHU assembly, the filter section has a pressure loss of 0.10 in. wg, the heating/cooling coil section has a pressure loss of 0.20 in. wg, arid the casing has a miscellaneous loss of 0.05 in. wg. The AHU is a modular unit complete with a fan that can produce 0.60 in. wg of total pressure at the required design flows. Design a round ductwork system, ensuring that the location of and pressure drops across appropriate dampers for balancing the system is clear for the convenience of the mechanical contractor and the client.

6. For most building design projects, the architectural trade tends to be the consultant (i.e., the lead consultant for the project) who hires the mechanical and the electrical trades as subconsultants on the project. In most cases, the mechanical engineering subconsultant has expertise in the design of ductwork to transport air for the purposes of heating and /or cooling an occupied space. The following section of a second floor tenant plan of an office building has been given by an architect. For the offices shown in the plan above (complete with the occupant and work function), the architect has requested the design of a ductwork system to provide air at 75 F to heat the occupied spaces. A HVAC engineer has determined the amount of air required to maintain the space temperature, and they are shown in the following table. However the engineer missed the fact that ASHRAE Standard 62 requires that 20 cfm per person of fresh outdoor air must be provided. (a) To ensure an esthetically pleasing finish in the space, the architect has requested the design of a ductwork system based on round ducts. Because most of the occupants of this section of

the floor are managers and/or directors in the complex hierarchy of the client's company, the architect would like to have a dedicated fan installed with the ductwork for this section of offices. The fan is to be located on the roof above the offices, and it will be fitted with a plenum section. (b) Based on the design of the ductwork, specify the minimum operating condition of the fan.

7. Fred, an engineering student, has prepared the following piping schematic to supply water to two heat exchangers for a project in his garage. The lengths shown are in feet. Piping is Schedule 40, commercial steel. The balance valve is of the globe type. The head loss of each heat exchanger is 10 ft. The flow through heat exchanger 1 is 20 gpm. The flow through heat exchanger 2 is 8 gpm. 20 ft 15 ft 12 ft pump 12 ft 9 ft Heat Exchanger 1 15 ft 15 ft Heat Exchanger 2 balance valve 9 ft 20 ft 15 ft 1. Is Fred s design correct (i.e., did he place the balance valve in the correct location)? 2. Complete the design of the piping system using a single diameter pipe throughout. 3. Determine the globe valve setting (in percent) following the linear charts below. 4. Find a suitable pump for the circuit using the Internet. Here is a suggestion: http://www.tacocomfort.com/# http://www.tacocomfort.com/product-category/pumps/ Globe Valve Setting Values globe valve setting head loss fully closed K L 20% 200 K L 40% 140 K L 60% 80 K L 80% 20 K L fully open 1.0 K L Globe Valve Loss Coefficients pipe nominal diameter (inches) loss coefficient K L 1/4 16 1/2 14 3/4 9.0 1 8.2 1 1/4 7.5 1 1/2 7.2

8. SD Consulting Engineers, Inc. has prepared the following piping schematic to supply water to a chemical plant. The lengths shown are in feet. Piping is Schedule 40, commercial steel. Complete the design of the primary circuit piping system.

9. The owner of a small office building has decided to design and install a piping network that includes 5 tankless water heaters to heat and transport water. The owner currently requires 18 gpm of hot water service. Cold water (feedwater) from the City will be supplied to each heater, and the piping connections were previously installed by the building contractor. The hot water, at 160 F, from the heaters will be transported through a main header for distribution in the rest of the building. Each heater has been specified to provide a maximum of 4.6 gpm of water. The heater unit has a dedicated pump that serves only to circulate the cold water through its internal finned-coil system. Unfortunately, the City supplies the feedwater at a low pressure of 40 psia, and the owner needs hot water at 80 psia for complete distribution though the building. Based on the sketch provided below, complete the design of the hot water supply lines in this system. Further Information: In practice, the lengths of the hot water supply piping that connect directly to the heaters are small in comparison to that of the main supply header. Heat exchanger losses are negligible.