THRU-THE-WALL AIR CONDITIONERS

Similar documents
Room Air Conditioners

ROOM AIR CONDITIONERS

ROOM AIR CONDITIONERS cool only heat pumps electric heat

built-in comfort GE built-in air conditioners New product introductions January 2010

Packaged Terminal Air Conditioner (PTAC)

Packaged Terminal Air Conditioner (PTAC)

Packaged Terminal Air Conditioner (PTAC)

built-in comfort GE built-in air conditioners and heat pumps

DUCTLESS ROOM AIR CONDITIONERS

NEW! Digital Packaged Terminal Air Conditioners. Over 40 standard features! Distinct, audible sound improvements

NEW 2011 DESIGN AIR CONDITIONERS

PTAC/PTHP. Packaged Terminal Air Conditioners and Heat Pumps. Residential & Light Commercial HVAC. Features: Performance:

Packaged Terminal Air Conditioner (PTAC)

room air conditioners #1 preferred brand of room air conditioners.

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

Zoneline vertical packaged terminal air conditioners

all-season comfort GE Zoneline packaged terminal air conditioners New product introductions Spring 2010

Air Conditioners and Heat Pumps. 115-Volt: WS08C10A, WS10C10A, WS12C10A 230-Volt: WS10C30A, WS13C30A, WS15C30A. 115-Volt: WE10C33A, WE13C33A, WE15C33A

Vert-I-Pak Series. Single Package Vertical Air Conditioners. Installs easily in a closet for quiet operation THE EXPERTS IN ROOM AIR CONDITIONING

PACKAGED TERMINAL AIR CONDITIONERS

PTAC 2017 Air Conditioner Collection

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

Breeze A revolution in room cooling.

FRIGIDAIRE PTAC COLLECTION AIR CONDITIONERS

Single Package Vertical Air Conditioners. Vert-I-Pak

GE Zoneline. vertical packaged terminal air conditioners Home Products and Services

PTAC Air Conditioners 11.7 EER / 3.4 COP. and Heat Pumps

E Z S E R I E S " W X 16" H

PTW 42 Series 230/208 VOLT

We bring good things to life. GE Room Air Conditioners The 1997 Line

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

We bring good things to life. Zoneline. Packaged Terminal Units PRELIMINARY

DUCTLESS SPLIT SYSTEMS AIR CONDITIONERS HEAT PUMPS

PTAC Air Conditioners 11.7 EER / 3.4 COP. and Heat Pumps

R11C R12C R21C R22C/H R23C/H R24C/H

Ductless SPLIT SYSTEMS. cool only HEAT PUMPS

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

SG SERIES PTACs THE EXPERTS IN ROOM AIR CONDITIONING

Room Air Conditioners. Kühl Kühl + Commercial grade durability. Wi-Fi ENABLED. with smart options to conserve energy and reduce your energy bill.

Service Instructions

Packaged Terminal Air Conditioners

COLOR OPTIONS Optional designer colored fronts sold separately. Satin Silver included.

Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat

ROOM AIR CONDITIONERS

Hazardgard. Product Profile. Engineered to perform in the harshest environments. Hazardous Location Room Air Conditioners

50TM COMBINATION HEATING/COOLING UNITS

DUCTLESS SPLIT SYSTEMS

FOR MODELS: 3PATWH10002

Owner s Manual. Important Safety Information. Operating Instructions The Controls on Your Air Conditioner Care of Product

R21C Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R21C. Straight Cooling Nominal Capacities

Room Air PRODUCT CATALOG. comfort, room by room

GE zoneline. Packaged Terminal Air Conditioners

Specifications and Performance

PRELIMINARY NEW PRODUCT GUIDE. Zoneline Packaged Terminal Air Conditioners

50TM TFF COMBINATION HEATING/COOLING UNITS

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

AE/AH R410A Window Air Conditioners & Heat Pumps

Packaged Terminal Air Conditioners. SG Series. Efficient and reliable for the lowest cost of ownership. More efficient. More reliable.

Specifications and Performance

ROOM AIR CONDITIONERS

Incremental Comfort Conditioners

R22C/H Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort

Service Manual R410A Models

ROOM AIR CONDITIONERS THE POWER TO MAKE EVERY ROOM MORE COMFORTABLE

Thru-the-Wall Series

Ductless Split Systems Concealed Duct Heat Pumps

Enviromaster International LLC 5780 Success Dr. Rome, NY Nominal Capacities: 30,000-36,000 Btuh

AIR CONDITIONERS SPLIT TROPICAL RANGE. FLAT SPLIT - Heat & Cool T1 R410a AMD K BTU EAN: AMD K BTU EAN:

Model TTWM1-14H ,000 BTU Cool 10,500 BTU Heat Electronic Through the Wall Air Conditioner Operating Instructions

VERT-I-PAK SERIES SINGLE PACKAGE VERTICAL AIR CONDITIONERS

Ductless Split Systems Ceiling Cassette Heat Pumps

Service Manual. WallMaster Thru-the-Wall. Models WM-ServMan (04-09) Fan. Cool M O D E TEM P E R AT U R E

TECHNICAL SPECIFICATIONS

Product Profile SINGLE PACKAGE VERTICAL AIR CONDITIONERS. Features

AIR CONDITIONERS 2017 COLLECTION. Window Portable Dehumidifier Through The Wall Ductless Split Units

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

MACH N-407 Heat Pump Air-Cooled Chiller

Room Air Conditioner

SPACE SAVING & EFFICIENT Zoneline Single Packaged Vertical Air Conditioners

Single Package Vertical Air Conditioners

OWNER S MANUAL PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Single Package Vertical Air Conditioners

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

SG SERIES. Packaged Terminal Air Conditioners PRODUCT PROFILE PRODUCT PROFILE. Features THE EXPERTS IN ROOM AIR CONDITIONING

_EMA_FRACB07_Comp 2/7/07 4:31 PM Page 1 Home Comfort

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

WIRING DIAGRAM. This manual describes the unit features and explains how to set-up, operate and maintain these AirPac Models. COOLIT2600 COOLIT2900

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

EASY DOES IT. Multiple Fan Speeds with Auto Cool

Product Information and Technical Guide

Service Manual A SERIES. Single Package Vertical Air Conditioning System For Years 2009 and *(Electronic Control)

GE AIR CONDITIONER ACCESSORIES Split System/Built-In/Window/Zoneline Models

_EMA_HomeCmft_FRAC08 1/23/08 4:36 PM Page 1 Home Comfort

STREAMLINED & EFFICIENT

READ ONLY. American Standard Ductless Systems Product Catalog. A Comfortable, Convenient Solution Built To A Higher Standard.

Transcription:

THRU-THE-WALL AIR CONDITIONERS 26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

WALLMASTER THRU-THE-WALL AIR CONDITIONERS 27 SLEEVE Ideal for new construction, and as a high efficiency replacement in retrofits and remodels QUALITY Features High efficiency operation saves on energy costs Residential/commercial applications Heat pumps and electric heat models Mounts flush with the exterior wall for a neat appearance Ideal for thicker wall installations, where side fins don t fit A high efficiency replacement for 27" sleeves including Fedders A and B*. Sleeve measures 27" W x 16 3/4" H Easy-to-reach, top mount controls Three-speed fan Efficient rotary compressor Easy-to-clean filter Auto restart Digital Control Features Remote control 24 hour programmable timer Money Saver setting saves energy by cycling the fan with the compressor Smart Fan auto-adjusts fan speed to maintain desired temperature Auto-memory backup saves setting should power be interrupted WallMaster COOLING HEATING 7,800-15,000 BTU/h 7,300-11,000 BTU/h Up to 10.5 EER Unit is shown installed in WSD sleeve (sold and shipped separately) *Installation in Fedders B sleeve requires a baffle kit. See BAK accessory under accessories. Sleeve Dimensions Friedrich Fedders A Sleeve Fedders B Sleeve* Height (inches) 16 3/4 16 3/4 16 3/4 Width (inches) 27 27 27 Depth (inches) 16 3/4 16 3/4 19 3/4

UNI-FIT THRU-THE-WALL AIR CONDITIONERS 26 SLEEVE Universal fit for easy replacement in existing 26 sleeves Features Rotary compressors provide quiet, dependable performance Six-way air flow control Auto restart Washable/reusable filter Seacoast protection Stale air exhaust HEAT/COOL MODELS feature mechanical controls, two cooling speeds, two heating speeds, plus one fan-only setting. COOLING MODELS feature electronic controls with remote control, Money Saver setting that saves energy by cycling the fan with the compressor and three cooling/three fan-only speeds. Digital Control Features (cool only models) 12 hour programmable timer Money Saver setting saves energy by cycling the fan with the compressor Uni-Fit COOLING HEATING 8,000-13,000 BTU/h 3,850-11,200 BTU/h Up to 9.6 EER Sleeve Dimensions White- Friedrich USC Sleeve Amana Carrier (51S Series) Fedders/ Emerson/ Friedrich WSD Emerson/ Fedders GE/ Hotpoint Whirlpool Westinghouse/ Frigidaire/ Carrier (52F Series) Height (inches) 15 17/32 15 5/8 16 7/8 16 3/4 15 3/4 15 5/8 16 1/2 15 1/4 Width (inches) 25 7/8 26 25 3/4 27 26 3/4 26 25 7/8 25 1/2 Units are shown without USC sleeve (USC sleeves sold and shipped separately) Depth (inches) 16 23/32 16 7/8 18 5/8 16 3/4 or 19 3/4 15 16 7/8 17 1/8 or 23 16, 17 1/2 or 22

WallMaster 27 Sleeve Exterior Grilles CORRECT Vertical Louvers Standard Grille - Ships with sleeve. Galvanized steel weather panel also ships with sleeve. Optional Architectural Grille- AG IMPORTANT: Operating the air conditioner with incorrect rear grille or without Baffle Adapter Kit (on 19 3/4 deep sleeve) will recirculate discharge air and cause compressor overload to trip. INCORRECT Horizontal Louvers Installation Accessories (27 sleeve models only) DK / Drain Kit Installed at the back of the unit and allows for attachment to permanent condensate disposal system, if disposal is necessary or desired. SB / Sub Base Used as a base for the unit when it is desired to place the cord and receptacle within the installation, or simply as a base for the unit when mounted low in the wall. IDK / Internal Drain Kit New construction applications where a condensate drain system has been built into the wall interior. BAK / Baffle Adapter Kit Necessary when installing in a sleeve deeper than 16 3/4" deep, such as Fedders B sleeve (19 3/4" deep). 16 3/4" Fedders B 19 3/4 Uni-Fit 26 Sleeve Exterior Grilles STANDARD GRILLE Ships with USC sleeve Expanded aluminum grille designed for use with USC sleeve. USC Sleeve Standard Grille Sleeve shown with Replacement Grille REPLACEMENT GRILLE Ships with US/UE chassis High-tech plastic for use on existing sleeves without any grille. IMPORTANT: When installing into an existing sleeve, consult Installation Section of your Installation/Operation Manual to determine whether or not the grille needs to be replaced and/or a baffle adapter should be used. Sleeve/Chassis Dimensions Model Height Width Depth Depth with Front Minimum Extension Into Room Minimum Extension Outside Thru-the-wall Finished Hole Height Width Max. Depth WALLMASTER 16 3/4" 27" 16 3/4" 23" 7 1/2" 9/16" 17 1/4" 27 1/4" 15 5/16" Chassis 15 3/4" 26 1/2" 21" 22 UNI-FIT USC Sleeve 15 1/2" 25 7/8" 16 3/4" 20 1/2" 1/2" 15 3/4" 26 1/8" 16 1/4" US Chassis 14 3/8" 24" 20 1/8" 3 3/4" US= 3 3 /8, UE= 2 7 /8 IMPORTANT: US chassis w/front fully installed into USC sleeve extends into room 3 3 /8. UE chassis w/front fully installed into USC sleeve extends into room 2 7 /8. IMPORTANT: Sleeves are sold and shipped separately to accommodate new construction and replacement requirements

Commercial & Residential Applications When should you install a solid side sleeve? SOLID SIDE wall sleeve allows for installation in thick exterior walls where the installation of room air units with side vents would effect performance and may even void the warranty. ROOM AIR CONDITIONER Blocked side vents restrict air flow THRU-THE-WALL units mount flush with exterior walls for a sleek appearance, as well as unobstructed window views. (Wallmaster WSD sleeve shown with architectural grille. Uni-fit grille has different appearance.) FRIEDRICH THRU-THE-WALL Solid-side sleeve (no side vents) can be installed flush with exterior wall.

Specifications En e r g y Sta r models Estar Model WALLMASTER Cooling Capacity Btu Heating Capacity Btu Volts Rated Cooling Amps Cooling Watts Heating Amps WallMaster Heat Pump heating information (shown in red) indicates heat pump heating performance. WallMaster Electric Heat heating information (shown in red) indicates electric heat strip performance. For WallMaster Heat Pump electric heating performance refer to corresponding WallMaster Electric Heat model. Heating Watts Energy Efficiecy Ratio EER Moisture Removal Pints/HR Room Side Air Circulation CFM WS08C10 7800 NA 115 7.1 788 NA NA 9.9 1.2 250 WSD 93 WS10C10 9700 NA 115 10.0 1032 NA NA 9.4 2.4 257 WSD 103 WS12C10 11900 NA 115 11.8 1266 NA NA 9.4 3.3 295 WSD 112 WS10C30 9500/9200 NA 230/208 4.5/4.7 989/958 NA NA 9.6/9.6 1.5 300 WSD 101 WS13C30 12600/11900 NA 230/208 6.3/6.7 1340/1266 NA NA 9.4/9.4 3.6 290 WSD 109 WS15C30 15000/14600 NA 230/208 8.3/8.2 1765/1718 NA NA 8.5/8.5 4.2 290 WSD 119 WY09C33 9300/9000 7300/7300 230/208 4.4/4.7 989/957 3.8/4.0 839/793 9.4/9.4 2.1 250 WSD 103 WY12C33 12000/11800 9350/9200 230/208 6.1/6.4 1395/1372 4.8/5.1 1062/1010 8.6/8.6 2.6 275 WSD 111 WE10C33 9500/9200 11000/9100 230/208 4.5/4.7 989/958 16.0/14.7 3550/2950 9.6/9.6 1.5 300 WSD 121 WE13C33 12600/11900 11000/9100 230/208 6.3/6.7 1340/1266 16.0/14.7 3550/2950 9.4/9.4 3.6 290 WSD 107 WE15C33 15000/14600 11000/9100 230/208 8.3/8.2 1765/1718 16.0/14.7 3550/2950 8.5/8.5 4.2 290 WSD 116 UNI-FIT UE08C13 8000 3850 115 7.5 830 10.7 1230 9.6 2.2 260 USC 73 UE10C33 10000/9800 11200/9200 230/208 4.7/5.2 1060/1040 15.3/14.0 3500/2900 9.4/9.4 3.2 285 USC 78 UE12C33 11500/11200 11200/9200 230/208 5.6/6.0 1220/1190 15.3/14.0 3500/2900 9.4/9.4 3.8 290 USC 80 US08C10 8000-115 7.5 830 - - 9.6 2.2 260 USC 73 US10C10 9800-115 9.6 1040 - - 9.4 3.2 285 USC 78 US12C10 11500-115 11.2 1220 - - 9.4 3.8 290 USC 80 US10C30 10000/9800-230/208 4.7/5.2 1060/1040 - - 9.4/9.4 3.2 285 USC 78 US12C30 11500/11200-230/208 5.6/6.0 1220/1190 - - 9.4/9.4 3.8 290 USC 80 US14C30 13000/12600-230/208 7.0/7.5 1530/1480 - - 9.4/9.4 4.0 310 USC 87 Sleeve Net Weight Lbs WALLMASTER HEAT PUMP HEATING PERFORMANCE: Change-over from heat pump operation to resistance operation on models indicated is automatic at a preset outside ambient temperature of approximately 35 F. Calculate the heat loss of the space to be heated. As long as the heat loss does not exceed the resistance heating capacity rating of the unit, the heating performance will be satisfactory. Note: all models will produce condensate. If condensate disposal is desired, an optional drain kit is available. DEFROST CONTROL: Initiated at 20 F (outdoor coil temperature) and terminated at 43 F (outdoor coil temperature). During defrost, the compressor stops and the electric heat starts, then operates with the fan to maintain indoor comfort. Below 43 F, the unit remains in electric heat mode. During electric heat mode, the unit will achieve the following ratings: 11000/9100 BTU/h, 16.0/14.7 amps, and 3550/2950 watts. DEFROST DRAIN: Drain automatically opens at approximately 50 F to prevent condensate from freezing inside drain pan. Plug Face/ Circuit Rating WallMaster Model Number WS08C10, WS09C10, WS12C10 Uni-Fit Model Number US08C10, UE08C13 US10C10, US12C10 Circuit Rating Breaker or T-D Fuse Plug Face (NEMA#) Power Cord Length (ft.) 125V - 15A 5-15P 6 Wall Outlet Appearance R-410A WS10C30, WS13C30, WS15C30 WE10C33, WE12C33, WE15C33, WY10C33, WY13C33 US10C30, US12C30, US14C30 250V - 15A 6-15P 4 UE10C33, UE12C33 250V - 20A 6-20P 4 All models use environmentally friendly R-410A refrigerant. Power cords are located on front left of WallMaster models and on front right of Uni-Fit models. As an En e r g y Sta r partner, Friedrich Air Conditioning Co. has determined that the selected En e r g y Sta r models ( ) meet the En e r g y Sta r guidelines for energy efficiency. Friedrich Air Conditioning Co. l P.O. Box 1540 l San Antonio, TX 78295-1540 l 800.541.6645 l fax 210.357.4480 www.friedrich.com TTW-10 Printed in USA