VERSATILE NEW BIW ALARM SYSTEMS DETECTS MOISTURE, LEAKS, HIGH LEVELS PLUS MANY OTHER OFF-NORMAL CONDITIONS

Similar documents
:~::d W:::)-!_-...~ L_Il! it-l----~ 115V10 N; El CB20A L21.T2 ~I-----i

Commercial and Light Industrial Fire Alarm Control Panel

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Gas and smoke detectors. (building technology) Gas alarm units. (private home) Gas alarm units (industrial) Gas alarm units. (building technology)

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Across-the-Line SERIES MP300 Combined Manual and Automatic

Soft Start Series MP700 Solid State, Reduced Voltage

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

TECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories

SECTION SANITARY SEWAGE PUMP STATIONS

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Instruction Manual Model A

Model A1600 Series Annunciator

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Type NLC Lighting Control Panels II II SQUARED I:OMPRNY. Class 8931 JUNE, 1982 SupersedeS Catalog Section Dated January Contents Class Pages

Specification/ Data Sheet

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

SECTION AUTOMATIC TRANSFER SWITCHES

Oxygen (O2) Single-Point Gas Detection System

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

FDF Foam Pump Controllers Features

PULL BOXES WITH MANHOLE. -x = co

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Centro-Matic Automated Lubrication Systems System Controls

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

SECTION AUTOMATIC TRANSFER SWITCHES

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

User Manual. Product: tempmate. -M1 Data Logger Scope: Operations Instructions. For tempmate. -M1 Multiple-Use PDF Temperature Data Logger.

Engineered Condensate Solutions

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

AlarmLine Addressable Linear Heat Detector

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

We ve Got Panels Under Control.

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

Model 4001 Series Single Channel Controller

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

RBC AC1 RUN & STANDBY CONTROL DRAWING NUMBER R1956

AL600ULADA. NAC Power Extender. Installation Guide

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

DIESEL Engine Fire Pump Controllers Features

Public Safety DAS Annunciator Panel

Tower & Obstruction Lighting

Mounting Plate ADA/HOSPITAL SIGNALING DEVICES 14-8 FEATURES. > Momentary switch push button > Stainless steel faceplate

CM800 Emergency Call System

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

SECTION AUTOMATIC TRANSFER SWITCHES

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Operating Instructions. For. Alarm Control Module. Model SSR 500

SIMPLEX WEATHERPROOF CONTROL PANELS

Two-Channel Gas Controller

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Variable Frequency Drive SERIES MP800 VFD

Life Alarm Multiplex Systems

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

Instructions. Infiniti Gas Transmitter Model U Rev: 4/

Custom Duct Heaters. Special Applications

SECTION LOW VOLTAGE LIGHTING CONTROLS

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

Pioneer-R16 Gas Monitor Operator s Manual

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition

AL800ULADA. NAC Power Extender. Installation Guide

Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Pump-Down Controller MODEL 4052

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

TECHNICAL DATA OBSOLETE

bmckup circuilb bm viommd.

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

Selectronic Tattletale Remote Alarm Annunciators

LMR Electric Fire Pump Controllers Features

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

SECTION ROTARY-SCREW WATER CHILLERS

Gate Operator. Modfications

Drawing Submittal Package

I/O ZONE 560/583 AND OPERATION MANUAL

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

ESP TECHNOLOGIES LIMITED

ELP21LU3-LF-HLOL THREE CHANNEL

Installation and Operating instructions

Construction Electrical

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

CONDENSATE MANAGEMENT SYSTEMS

Transcription:

B/W Controls SERES 41 SOLD STATE ALARM SYSTEM SECTON 1 VERSATLE NEW BW ALARM SYSTEMS DETECTS MOSTURE, LEAKS, HGH LEVELS PLUS MANY OTHER OFF-NORMAL CONDTONS.. tim. FEATURNG: General purpose or industrial and weatherproof enclosures Field-adjustable sensitivity from 1000 ohms to 1 megohm Low energy sensing circuit ideal for liquid level electrodes or pilot switches Field-adjustable time delay 0 to 3 sec. to eliminate false trips Ability to operate from remote sensors

SECTON B/W Controls VERSATLE NEW ALARM DETECTS MOSTURE, LEAKS AND HGH LEVELS, PLUS OFF-NORMAL COND TONS NVOLVNG A WDE VARETY OF PROCESS VARABLES AND BULD NG SECURTY APPLCATONS BW Series 41 Solid-State Alarm Systems are designed to provide new versatility, safety and reliability in monitoring and detecting off-normal conditions in a broad range of industrial, commercial and institutional applications. Key feature of the system is its low energy adjustable sensing circuit which assures reliable operation from electrodes contacting conductive liquids or from contact-type pilot devices such as flow, float, pressure and limit switches, thermostats and pushbutton actuators, etc. As a result, the system can be used to detect moisture or leaks in mines, underground communication networks, boat bilges, computer rooms, libraries, archives and record storage areas. t is also ideal for monitoring dangerous high level conditions in storage tanks, cooling towers, storm drain sumps, septic tanks, sewer systems, lakes, streams, and other locations requiring detection of overflow or flooding. n addition, because Series 41 Alarms will also operate from contact-type pilot devices, they are equally suitable for use in monitoring process variables such as temperature, pressure, flow, humidity, voltage and current, etc., as well as building security and fire detection alarms. nstallation is quick and easy with saddle clamp barrier terminal blocks for 1 to 18 gauge wire, or ring terminal connections to field wiring. OPERATNG FEATURES AND ADVANTAGES BW Series 41 Alarm Systems also provide field-adjustable sensitivity from 1000 ohms up to 1 megohm to assure reliable operation over long distances and in detecting leaks or high levels of a wide variety of conductive liquids. A field-adjustable time-delay is also provided to eliminate false trips due to liquid turbulence or electrical transients. The alarm action does not start until the time delay is completed. Other features include: A SPOT auxiliary relay which has its coil energized when the process condition is normal so that its contact can be used to provide fail-safe remote signal, alarm or cut-off of pumps, valves, motors and other operating equipment in the event of a component or power failure. A holding circuit which permits operation over a range of levels or from momentary contact switching devices. lluminated SLENCE and TEST pushbuttons and optional manual RESET button. SNGLE ALARM PERFORMS MULTPLE FUNCTONS Regardless of usage, however, a single alarm system may be applied with several electrodes or pilot devices connected in parallel to provide an audible alarm in the event a fault condition occurs at one or more of the remote detection points being monitored. Moreover, the low voltage and low current level of the sensing circuit permits use of low cost small gauge unshielded communication wires for long distance alarm installations. BASC SPECFCATONS: Voltage: Standard: 115 volts ac- 50/ 60 hertz Optional: 30 volts ac- 50/ 60 hertz. 4 volts. de. Power Required: General Purpose Model ndustrial & Weatherproof with 6" Bell with Horn 6VA 11 VA 15 VA Contact Rating: Single pole, double throw; 6 amperes resistive load at 10 volts ac. Sensing Circuit: 4 volt de and 0.5 milliamperes maximum. Sensitivity field adjustable from 1000 ohms up to 1 megohm. Time Delay: Adjustable from 0 to 3 seconds. Pushbuttons: SLENCE and TEST buttons are standard. RESET button is optional. GENERAL PURPOSE MODEL For indoor service in a steel enclosure with a solid state audible alarm. NDUSTRAL & WEATHERPROOF MODEL For outdoor or indoor service in a fiberglass enclosure and with choice of a horn or a 6 inch bell. DESCRPTON OF OPERATON STANDARD SEQUENCE is automatic reset with silence pushbutton and without lock-in, SA designation A-1-4, with the extra feature of an adjustable time delay after the fault condition occurs which delays the alarm action for the set time period. The auxiliary SPOT contact is a fail safe arrangement that follows the alarm light status. The test pushbutton provides full operational test simulating an abnormal condition. MANUAL RESET SEQUENCE operates the same as the standard sequence except that a momentary fault condition will lock-in the alarm status until the condition returns to normal, and the reset pushbutton is operated. The SA sequence designation is M-1. Sensing Process Circuit Line Condition Status 1 Normal Open Normal Open 3 Normal Open 4 Abnormal Closed 5 Abnormal Closed 6 Normal Open Operation for Manual Reset Push Button Model 6A Abnormal Closed 68 Normal Open Operator Push Button Action SEQUENCE TABLE Alarm Status Test Silence Reset Light Audible Push Off Off Flashing Flashing On On Push On Off This option will lock-in a momentary abnormal condition at the status of line 4. After the condition returns to NORMAL, an operator action is required to reset alarm status. Line 6 is replaced by the following action. Push Flashing On Push Off Contact Status A B Remarks Closed Open Line voltage - off Open Closed Line voltage - on Closed Open Status goes to Line 4 Closed Open Alarm occurs after time delay which is adjustable 0-3 seconds Closed Open Open Closed Automatic Reset Closed Open Open Closed Abnormal condition is locked-in Status goes to Line 4 and must silence again CATALOG 79

B/W Controls SECTON 3 TYPCAL APPLCATONS Diagrams below illustrate basic details of typical installations ir1 which Series 41 Alarm Systems are used to monitor and detect any off-normal conditions in applications involving the control of liquids and various common in-process variables. ~ J... SUGGESTED CONTROL SETTNGS Sensitivity: Set to a value greater than the specific resistance of the liquid to be controlled. Time Delay: Normally 0- second or just long enough to prevent nuisance alarms resulting from wave action of the liquid. n Diagram A, the system consists of one electrode set at the predetermined danger level and a second common electrode set at the same or a slightly lower level to complete the sensing circuit. n Diagram B, the jumper is removed from terminal block and a third reset electrode is used. The alarm will then go off automatically when liquid falls below the reset electrode. Diagram C is essentially the same except a normally-closed pushbutton is used to lock in alarm instead of a reset electrode. n Diagram D, a good ground return to the liquid is used to complete the sensing circuit instead of a common electrode. OPERATON FROM ELECTRODES Diagram A - High Level Alarm or Leak Detection System Diagram B - High Level Alarm or Leak Detection System with Automatic Reset Electrode ~ =-JuMPER---l ~-JUMPER-REMOVED] ~----- --pi / ELECTRODE HOLDER ~===-=--=--=-~- -~ 1 A~:~T~~DE HOLDER SENSNG CRCUT SENSNG CRCUT ABOVE THS LEVEL TERMNAL STRP ALARM ON ABOVE THS LEVEL TERMNAL STRP ALARM OFF BELOW THS LEVEL COMMON COMMON ALARM OFF ELECTRODE ELECTRODE BELOW THS LEVEL Diagram C - High Level Alarm or Leak Detection System with Lock-n and Reset Pushbutton r-j"l!mp"efl FiENioVEo - - ~ L -~- _j -El ~~;~-:~Lt / ELECTRODE HOLDER RESET 1 ALARM ON PUSHBUTTON ABOVE THS LEVEL SENSNG CRCUT COMMON ELECTRODE TERMNAL STRP Alarm will lock in until level falls below electrode and reset button is operated. Diagram ---------1 D - High Level Alarm Operated from Ground Return instead of Common Electrode - JUMPER ~ ELECTRODE HOLDER -, ALARM ON l ~ -:!:- ABOVE THS LEVEL L_AGOOD ALARM OFF DEPENDABLE BELOW THS LEVEL ROUND RETURN _[ TO THE LQUD S =-. J REQURED L...J SENSNG CRCUT TERMNAL STRP SUGGESTED CONTROL SETTNGS Sensitivity: Normally set at minimum of 1000 ohm except when operating from a resistance transducer. Time Delay: Normally 0-1 second or just long enough to prevent nuisance trips. n Diagram E, the Series 41 Alarm is used with a BW Unifloat multiple switch level sensing assembly which can be applied to control any non-conductive or conductive liquid. n Diagram F, a remote pilot device is used to actuate the alarm in event of off-normal conditions such as temperature, smoke, pressure, flow, proximity, etc. Diagram G is similar except jumper at terminal block is removed and a normally closed pushbutton is used to lock in alarm. n Diagram H, a transducer that lowers resistance is used to sense any off-normal condition and trip the alarm. OPERATON FROM PLOT SWTCHES Diagram E - Hi!;Jh Level Alarm System Operated from B fw Unifloat common wire may be omitted if Terminal 6 is grounded. Diagram G - Security or Fire Alarm Operated from Pilot Device with Lock-n and Reset Button ~~@(~(~~~OVED- - ~CONTACT OF 1:@:----: ---~- -- _j PLOT DEVCE NC MANUAL ALARM ON WHEN LJ RESET CONTACT CLOSES PUSHBUTTON L_~ j SENSNG CRCUT TERMNAL STRP Alarm will lock-in until contact of pilot device opens and reset button operated. Diagram F - Process Alarm with Remote Pilot Switch Actuated by Off - Normal Conditions L - -- ---~~R~~~WHEN CONTACT S OPEN - JUMPER _1.. CONTACT OF, - PLOT DEVCE ---- - ALARMON-W~EN CONTACT S CLOSED SENSNG CRCUT TERMNAL STRP o ff-normal conditions may be temperature, smoke, pressure, humidity, flow, proximity, counter, voltage, current depending on type of pilot device used. Diagram H - System with Device that Reduces Resistance when Actuated by Fault Condition L.=JuMPER-------f.3!-rn- PHOTO CELL 1 OR MOSTURE --------- DETECTOR ETc. SENSNG CRCUT TERMNAL STRP *Alarm sounds when sensing circuit resistance drops below sensitivity set point.

SECTON 4 B/W Controls GENERAL PURPOSE MODEL AUDBLE ALARM ELECTRONC TYPE 73db SLENCE PUSHBUTTON WTH RED LGHT TEST PUSHBUTTON WTH GREEN LGHT WRNG DAGRAM ADJUSTABLE TME-DELAY 0 to 3 SECONDS ADJUSTABLE SENSTVTY 1000 OHMS TO 1 MEGOHM rm, ------H } SENSNG CRCUT 4 VOLTS DC AND e o----- - - - 0.5 MA MAXMUM.>----+--BARRER-TYPE TERMNAL STRPS AUXLARY CONTACTS - A & B DMENSONS f! ~~~r=::-- ~b~~~ng HOLES ll PADLOCK-TYPE 10.00 9.00 8.00 DRAW PULL CATCH AUXLARY RELAY CONTACT C l. ~- ~- ~- ~- ~ OPERATON N EVENT OF ALARM t o_"!'!'~."-.j i : ' ' OR POWER OR RELAY FALURE -- ~~!'!'!«! _A ) : i t._} LNE VOLTAGE CONTACT"' A" CLOSES ---~~'!ti'~!.!'.j ~-- 115 VOLTS AC- 50/ 60 HERTZ AND CONTACT " B" OPENS 1" &1114" KNOCKOUTS The General Purpose Enclosure is made of 16 ga. steel with gray baked enamel finish and is intended for indoor applications. NDUSTRAL AND WEATHERPROOF MODEL WRNG DAGRAM AUDBLE ALARM Horn - Grille type, Adjustable 70 to 103 db. ' Bell - 6 inch Gong 9 db. at 10 ft. ADJUSTABLE TME DELAY 0 to 3 SECONDS SLENCE PUSHBUTTON - H - -, WTH RED LGHT TEST PUSHBUTTON WTH GREEN LGHT The enclosure is molded fiberglass in machine tool gray color with a closed cell neoprene cover gasket. t is rated NEMA 1 oiltight and dust-tight, and also meets NEMA 3 requirements for outdoor installation. The cover devices are watertight industrial quality. The stainless steel hinge and latch conform to NEMA 4X cor- ADJUSTABLE SENSTVTY 1000 OHMS TO 1 MEGOHM - +}SENSNG CRCUT 4 VOLTS DC AND. - - 0.5 MA MAXMUM BARRER-TYPE TERMNAL STRPS AUXLARY CONTACTS TRANSFORMER rosion resistance standards, however, in order to meet the severe NEMA 4 watertight hose test, screw cover fasteners are required rather than the luggage latch. This option is available and if required specify "NEMA 4X Watertight" when ordering. llfl -CJ DMENSONS ~ "il, (] ill1 o 0 o r BELL 7.75 HORN 7.06 r~=======::::j 4.5 1.13 LY=='====="=--- 4 MOUNTNG HOLES.313 DAMETER OPTONAL COVER SCREWS FOR NEMA 4X RATNG LUGGAGE LATCH WTH PADLOCKNG HASP NO CONDUT OPENNGS ARE PROVDED. CONDUT HUBS ARE AVALABLE FOR FELD MOUNTNG. 'CATALOG 81

B/W Controls SERES 41 SOLD STATE ALARM SYSTEM SECTON S 601 AND 6013 BW LEVEL SENSNG ELECTRODE EQUPMENT CAST ELECTRODE HOLDERS PLASTC ELECTRODE HOLDERS ce Free Pressure nght Flanged Cast ron Conduit Flanged PVC Molded 7014 UNFLOAT MOSTURE SENSOR Switches continue to operate even during power failure Simple level adjustment without disturbing tank connection. Single float for up to 1 sensing levels deal in non-conductive liquids such as gasoline, fuel oil and chemicals UL Recognized Encapsulated reed switches provide dry contact for direct interface to programmable controllers in. or 3 in. Pressure-tight holder Pressure-Tight " or3" NPT 'iu U.L. Recognized Component Low Level Reed Switch Float Stop & Tube Seal U.S. Patent No. 4,056,979 The moisture sensor is a compact, low cost device which can be easily attached with two screws or with the adhesive provided. When moisture bridges adjacent printed circuit paths on the surface of the sensor, the Series 41 Alarm System will provide an audio-visual indication and isolated SPOT contacts for auxiliary control. The BW moisture sensor is ideal to detect water under computer room floors, in communication vaults, in archives, in below grade ductwork, on floors in basements, storage areas or equipment rooms. BW system of low voltage low current sensing permits use of inexpensive field wiring between sensor and alarm. See Catalog Section 6013 for detailed information. 'CATALOG 8

SECTON 6 SERES 41 SOLD STATE ALARM SYSTEM B/W Controls Series 41 alarm system with the general purpose enclosure and a reset button shown with a conduit holder with wire suspension electrodes. Series 41 alarm system with the general purpose enclosure shown with BW Moisture Sensors. Series 41 alarm system with the industrial enclosure shown with a molded electrode holder. CATALOG NUMBERNG SYSTEM AND LST PRCES SERES 41 ALARM SYSTEM WTH GENERAL PURPOSE NEMA 1 ENCLOSURE DSCOUNT SCHEDULE LL 1 Prices Subject to Change Without Notice --100-L1 --------------------------R-------N1 CATALOG ~ SECTON LST LST LNE VOLTAGE PRCE OPTONS PRCE a... L1 115 VAC 50/ 60Hz $188.88 X No Addition L 30 VAC 50/ 60 HZ $118:88 R Reset Add L3 4 VDC $i Button SERES 41 ALARM SYSTEM WTH NDUSTRAL OR WEATHERPROOF ENCLOSURE -1300--H----------R--------N3 CATALOG SECTON LST*... LST ALARM TYPE PRCE OPTONS PRCE s 6" Bell 9db $8118.111 lx Ad~Wion H Horn 78-103db eooum. R Reset Add Button *For 115 VAC 50/60HZ line voltage only. Contact factory for optional 30 VAC 50/60 HZ prices. ENCLOSURE N3 Meets Nema 3 and Nema 1 N4 Nema 4X Watertight* *See pg. 4 for enclosure description. LST PRCE No Addition Add ~ ~ PVC HUBS - WTH 0 RNG SEAL FOR PLASTC CONDUT CONDUT SZE PART NUMBER Y nch 04-97400 3!4 nch 04-9700 CONDUT HUBS LST PRCES LST PRCE... ALUMNUM HUBS - Field installation is simple using standard electrician's hole saw or punch. WTH GROUNDNG SCREW FOR METAL CONDUT CONDUT PART... LST SZE NUMBER PRCE Y nch 04-3400 3 /4 nch 04-63500...,. CATALOG 83

SECTON 8040 B/W Controls 4 BW Signal and Alarm panels are available in many standard packaged units designed for use in a wide range of high, low and intermediate level alarm applications as well as for remote control signalling. Each contains the proper BW level sensing relays and operates from electrudes set at desired alarm levels. These panels can also be furnished with one or more BW pump control relays included in the package to perform any desired level control function. Also these alarm systems can be incorporated into any of the other control systems shown in this catalog. Contact us for assistance to meet your specific needs. DSCOUNT SCHEDULE LL 1 Prices Subject to Change Without Notice Catalog Number Example 8040-SC1H-H-L1-N1----------1500-S7 X H 0 LSTPR CE RELAY ENCLOSURE ADDT ON SENSTVTY N1 Nema 1 Select from Chart S1-S11 N4 Nema4 Sec. 1500 pg. 9 N1 Nema 1 LF1,HF Select from Chart Section 500 Page 5 LV1- Select from Chart LNE VOLTAGE LST PRCE HV3-4-5 Section 500 Page 5 ADDTON v Select from Chart L1 115 Volt 50/60 Hz... F1-F8 Section 5300 Page 5 L 08-30 Volt 50/60 Hz OPTONAL FEATURES Horn instead of Bell... nclude additional relay for control functions. Specify details LST PRCE ADDTON Consult Factory RELAY TYPE 1500 nduction Type 1500 500-L Series 5-low sensitivity 500-H Series 5-high sensitivity 5300-S Series 53-1 0 amp contacts 5300-P Series 53-5 amp contacts LST PRCE ADDTON...... LSTPRC E ADDTON,...... SV1H NUMBER OF ELECTRODES 3 4 5 6 TYPE OF OPERATON LST PRCE High Level Signal $... Low Level Signal $ - VSUAL SGNALS High and Low Level Signal $ Willi AND ALARMS Three Level Signals $._ Four Level Signals "' ll Signal Lights Only Five Level Signals $ 1111111 3 High Level Alarm $~ AUDBLE SGNALS Low Level Alarm s..- AND ALARMS High and Low Level Alarm $ 411111 *Bell or Horn Only High Level Alarm s-... *Bell or Horn with Two-Position Low Level Alarm $... Manual Reset Silence Switch Operates from single pole 0 pivot device to indicate any $... COMBNATON VSUAL off-normal condition AND AUDBLE SGNALS AND ALARMS SC1H High Level Signal and Alarm $... SC1L Low Level Signal and Alarm $... Signal Lights *Bell or Horn, SC 3 High and Low Signal and Alarm s...-. Pushbutton Silence Switch High and Low Signal and Alarm SC3 4 Automatic Reset ntermediate Level Signal NOTE: A common electrode is included and it may be omit- *Bell with 4 inch gong is standard ted if a dependable ground return connection to the liquid is 85 db. at 10ft. provided by other means. Horn is optional Adjustable 70 to 103 db. BW Controls CA:;~~ i