LINE COMPONENTS VALVES

Similar documents
T2 thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. The refrigerant superheat determines the amount.

Thermostatic Expansion valves, type TUA/TUAE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION. 71

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Flexible. Upgrade and service with ease Extend lifetime with modular design. Thermostatic expansion valves Type TE5-55

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valves, type TR 6 REFRIGERATION & AIR CONDITIONING DIVISION.

Thermostatic Expansion Valves Type TR 6

FSW. Product guide. Driers and Sight Glasses CSECTION For more information visit

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Thermostatic expansion valves for ammonia Type TEA

General information on refrigerant controllers

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

Filter Driers with Replaceable Core

Hot gas bypass regulator, type CPCE Liquid gas mixer, type LG (accessory)

MAKING MODERN LIVING POSSIBLE. One valve for all purposes. TGE - thermostatic expansion valves REFRIGERATION & AIR CONDITIONING DIVISION

Accumulators - Suction Line

Emerson Superheat Control. The smart solution for your application

500 EX Fusion Compressor Series

Product Catalog VALVES

SANHUA S OFFER FOR REFRIGERATION APPLICATIONS

Easy Find the right products fast with our Quick Selection Guide. Products and technologies for all your application needs, today and tomorrow

Easy. Products and technologies for all your application needs, today and tomorrow. Quick Select Guide 2017

Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability

Zero ODP and negligible GWP when using hydrocarbons. Zero. portfolio for hydrocarbons.

Check valve Types NRV and NRVH

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

REFRIGERATION PRODUCTS

Chapter-8 Capacity Control of Refrigeration Systems

Thermostatic Expansion Valves

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Bulletin , March Electric Hot Gas Bypass Valves

Air-Cooled Condensing Units with Compact Screw Compressors

Energy Use in Refrigeration Systems

REFRIGERANT CHANGEOVER

FSW SECTION. Product guide. Thermostats, Pressure Switches & Fan Speed Controls. E SECTION For more information visit

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

DESIGN STANDARDS SECTION 15600

DANFOSS OPTYMA PLUS INVERTER UNITS

PULSE WIDTH MODULATING VALVES

DDNCY (Temporary use)

COMMECH SERIES AIR CONDITIONING CSH SEMI-HERMETIC SCREW PACKAGES. ORIGINAL MANUFACTURED EQUIPMENT Commech Series New Models BA AUS

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

49 Danfoss Thermostat Kits Ranco Varifix Kits

Refrigeration and Air Conditioning Controls. Applications. PM Modulating pressure and temperature regulators REFRIGERATION AND AIR CONDITIONING

RCY. Filter drier receiver units 4.1. Refrigeration & Climate Components Solutions. n Applications

Sealed Type Liquid Line and Suction Line Specifications

64 bar. DCY-P6 / 64 bar (928 psig) Anti-acid filter driers 1.9. subcritical. Refrigeration & Climate Components Solutions.

Dehydrators and Filters

Pressure switch KPU. Data sheet

November 2006 / BULLETIN ELECTRIC DISCHARGE BYPASS VALVES

ELIMINATOR Hermetic filter drier for CO₂ DMSC for Sub-critical and DMT for Trans-critical application

1+ SEER. 25% COP boost possible. Most valves expand your refrigerant EcoFlow expands your options. with silent defrost.

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

PWM expansion valves 2028

Technical Information

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1

Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions

DEHYDRATORS AND FILTERS

PowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois

AE Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A

Copeland Scroll Condensing Units for the Food Service Market

Refrigeration Systems and Accessories

.2 Section Waste Management and Disposal.

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

Liebert CSU3000 Chiller

June 2001 / BULLETIN Way Valves. The right solenoid valve for any job.

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Low Pressure Sight Glass Up to 35 bar MWP Type SG

30GT FLOTRONIC AIR-COOLED CHILLERS

Suction Accumulators. Introduction. Suction Accumulators

YCAL-SB Millennium AIR COOLED LIQUID CHILLER R407C REFRIGERANT. COOLING CAPACITIES 141 kw to 360 kw

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

30GN FLOTRONIC II AIR-COOLED CHILLERS

Research Design Quality Value Service Experience

One. Save time and money Streamline your heat pump business! makes a difference.

WHA WHA. Ground source water to water heat pumps A ++ A ++ Versions

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

MYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1

Commercial High-Efficiency Condensing Units

EC3-X33 Stand-alone Superheat Controller Technical Data

R-407A R-448A R-449A

Refrigerant changeover guidelines

50% Refrigeration solutions to lower energy costs and reduce environmental impact. Foodservice Solutions. Up to

Condensing Units CUS 15-60

Optyma Slim Pack Condensing Units

Air-Cooled Condensing Units with Bitzer Compressors

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

Process glycol chillers

VCYL. Liquid sight glasses 9.1 NEW. Refrigeration & Climate Components Solutions. Max WP 46 bar and multi-fluids (G1 or G2) n Applications

SECTION REFRIGERANT PIPING

Call us today! (800)

10/4/2013. The Changing State of Refrigerants

Transcription:

VALVES DANFOSS THERMOSTATIC EXPANSION VALVES - T2 T2 thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. The refrigerant superheat determines the amount. Large temperature range, suitable for freezing, refrigeration and air conditioning applications. Interchangeable orifice assembly MOP Valves (Max. Operating Pressure) availiable - protects the compressor motor against excessive evaporating pressure during normal operation. DESCRIPTION REFRIGERANT TEMPERATURE RANGE C EQUALISED CONNECTIONS TYPE IN. OUT. BDA0020 068Z3206 TX2 R22/R407C +10 TO -40 INT 3/8 1/2 FLARE BDA0040 068Z3209 TEX2 R22/R407C +10 TO -40 EXT 3/8 1/2 BDA0060 068Z3281 TX2S R22/R407C +10 TO -40 INT 3/8 1/2 BDA0080 068Z3284 TEX2S R22/R407C +10 TO -40 EXT 3/8 1/2 BDA0100 068Z3346 TN2 R134A +10 TO -40 INT 3/8 1/2 FLARE BDA0120 068Z3348 TEN2 R134A +10 TO -40 EXT 3/8 1/2 BDA0140 068Z3383 TN2S R134A +10 TO -40 INT 3/8 1/2 BDA0160 068Z3385 TEN2S R134A +10 TO -40 EXT 3/8 1/2 BDA0180 068Z3389 TEN2 MOP55 R134A (MOP55) -40 TO 10 EXT FLARE 3/8 1/2 BDA0200 068Z3400 TS2 R404A/R507 +10 TO -40 INT 3/8 1/2 FLARE BDA0220 068Z3403 TES2 R404A/R507 +10 TO -40 EXT 3/8 1/2 BDA0240 068Z3414 TS2S R404A/R507 +10 TO -40 INT 3/8 1/2 BDA0260 068Z3415 TES2S R404A/R507 +10 TO -40 EXT 3/8 1/2 BDA0280 068Z3408 TS2 MOP 50 BDA0300 068Z3409 TES2 MOP50 R404A/R507 (MOP50) R404A/R507 (MOP50) -40 TO -15 INT 3/8 1/2 FLARE -40 TO -15 EXT 3/8 1/2

VALVES DANFOSS ORIFICE - T2 NOMINAL CAPACITY ORIFICE NUMBER R22 R134A R404A -5SST -25SST -5SST -25SST -5SST -25SST BDA0320 068-2002 0X 1.0 0.9 0.7 0.6 0.7 0.6 BDA0340 068-2003 00 1.8 1.4 1.2 0.8 1.3 0.9 BDA0360 068-2010 01 3.3 2.1 1.9 1.1 2.4 1.4 BDA0380 068-2015 02 4.2 2.5 2.2 1.3 3.2 1.7 BDA0400 068-2006 03 7.2 4.2 3.7 2.1 5.5 2.9 BDA0420 068-2007 04 10.8 6.2 5.5 3.2 8.5 4.2 BDA0440 068-2008 05 14.6 8.1 7.2 4.1 11.2 5.5 BDA0460 068-2009 06 17.0 9.4 8.6 4.9 13.4 6.6 Based on 45 C condensing temperature. 4k Subcooling. Factory setting = 5K Increase superheat - Clockwise turn, reduces flow Decrease superheat - Anti-clockwise turn, increases flow TX VALVE ISOLATION COVER Universal design, suitable for a range of brands Compact design suitable for internal and external balance Easy assembly Strong insulating properties Temperatures down to -45 C Ice blocking Stylish appearance DESCRIPTION BDA1000 CFTXCOV Isolation Cover Tx Valve

VALVES DANFOSS THERMOSTATIC EXPANSION VALVES - TE5 TO TE55 The TE series expansion valve regulates the injection of refrigerant into evaporators. It controls the refrigerant flow based on the superheat. The exchangeable power element is produced with Danfoss laser welding technology for extended lifetime capability. Interchangeable orifice assembly. Stainless steel power element, capillary tube and bulb. Wide capacity range. Superior charge performance. Balanced orifice design on TE55 series. DANFOSS ELEMENTS - T5 DESCRIPTION REFRIGERANT TEMPERATURE RANGE C EQUALISED TYPE BDA0480 067B3250 TEX5 R22/R407C BDA0500 067B3297 TEN5 R134A BDA0520 067B3342 TES5 R404A/R507-40 TO +10 EXT BDA0540 067B3358 TES5 MOP45 R404A/R507 (MOP45) -40 TO -15 DANFOSS VALVE BODY - T5 DESCRIPTION DIRECTION CONNECTION TYPE IN. OUT. BDA0560 067B4009 T5 Body ANGLE 1/2 5/8 BDA0580 067B4007 T5 Body STRAIGHT 1/2 5/8 BDA0600 067B4010 T5 Body ANGLE 1/2 7/8 BDA0620 067B4008 T5 Body STRAIGHT 1/2 7/8 BDA0640 067B4013 T5 Body ANGLE FLARE 1/2 5/8 BDA0660 067B4011 T5 Body ANGLE 5/8 7/8 BDA0680 067B4034 T5 Body ANGLE 7/8 1 1/8

VALVES DANFOSS ORIFICE - T5 NOMINAL CAPACITY ORIFICE NUMBER R22/R407C R134A R404A/R507-5SST -25SST -5SST -25SST -5SST -25SST BDA0700 067B2788 0.5 9.9 6.7 6.1 3.9 7.4 4.7 BDA0720 067B2789 01 18.2 12.3 11.2 7.1 13.5 8.7 BDA0740 067B2790 02 25.4 17.3 15.7 10.0 18.9 12.2 BDA0760 067B2791 03 32.0 21.6 19.9 12.7 23.8 15.1 BDA0780 067B2792 04 43.7 29.0 27.1 17.0 32.5 20.4 Based on 45 C condensing temperature. 4k Subcooling. Factory setting = 5K Increase superheat - Clockwise turn, reduces flow Decrease superheat - Anti-clockwise turn, increases flow DANFOSS ELEMENTS - T12 DESCRIPTION REFRIGERANT TEMPERATURE RANGE C EQUALISED TYPE BDA0800 067B3210 TEX12 R22/R407C BDA0820 067B3232 TEN12 R134A -40 TO +10 EXT BDA0840 067B3347 TES12 R404A/R507 DANFOSS VALVE BODY - T12 DESCRIPTION DIRECTION CONNECTION TYPE IN. OUT. BDA0860 067B4022 T12 Body ANGLE BDA0880 067B4020 T12 Body STRAIGHT BDA0900 067B4021 T12 Body ANGLE BDA0920 067B4023 T12 Body STRAIGHT 5/8 7/8 7/8 1 1/8 DANFOSS ORIFICE - T12 NOMINAL CAPACITY ORIFICE NUMBER R22/R407C R134A R404A/R507-5SST -25SST -5SST -25SST -5SST -25SST BDA0940 067B2708 05 43.7 33.9 33.3 21.3 42.6 25.3 BDA0960 067B2709 06 51.2 43.5 43.7 27.4 53.2 30.7 BDA0980 067B2710 07 67.7 54.0 56.0 35.5 63.6 36.3 Based on 45 C condensing temperature. 4k Subcooling. Factory setting = 5K Increase superheat - Clockwise turn, reduces flow Decrease superheat - Anti-clockwise turn, increases flow

VALVES DANFOSS THERMOSTATIC EXPANSION VALVES - TUA/TUAE TUA/TUAE valves are made of stainless steel and can be used in many different forms of refrigeration systems, for example: Traditional refrigeration systems, Heat pump systems, Air conditioning units, Refrigeration appliances, Liquid coolers, Ice cube machines, Mobile refrigeration systems Interchangeable orifice assembly designed for easy mounting and optimized tightness Bimetal connections - Simple, fast soldering without the need for wet cloth or refrigeration pliers. Stable regulation Biflow function (orifice 1 to 8) Compact design - small dimensions and low weight Stainless steel, solder version - high connection strength and tightness - capillary tube joints of high strength and vibration resistance Laser-welded, stainless steel thermostatic diaphragm element - optimum function - long diaphragm life - high pressure resistance Stainless steel bulb - simple and fast installation - good heat transfer from pipe to bulb Interchangeable filter for easy cleaning DANFOSS TUA TX VALVES DESCRIPTION REFRIGERANT TEMPERATURE RANGE C EQUALISED CONNECTIONS TYPE IN. OUT. BDB0020 068U2205 TUA INT R134A BDB0040 068U2207 TUAE EXT +10 TO -40 BDB0060 068U2285 TUA INT R404A/R507 BDB0080 068U2287 TUAE EXT 3/8 1/2 NOMINAL CAPACITY ORIFICE NUMBER R134A R404A/R507-5SST -25SST -5SST -25SST BDB0100 068U1030 0 0.5 0.3 0.4 0.3 BDB0120 068U1031 1 0.6 0.4 0.6 0.4 BDB0140 068U1032 2 0.9 0.5 0.8 0.5 BDB0160 068U1033 3 1.2 0.7 1.2 0.6 BDB0180 068U1034 4 1.8 1.0 1.7 1.0 BDB0200 068U1035 5 2.4 1.3 2.3 1.3 BDB0220 068U1036 6 3.6 1.9 3.4 2.0 BDB0240 068U1037 7 4.9 2.6 4.6 2.6 BDB0260 068U1038 8 7.3 3.9 6.8 4.0 BDB0280 068U1039 9 10.8 5.7 10.2 5.8 Based on 45 C condensing temperature. 4k Subcooling. Factory setting = 4K Increase superheat - Clockwise turn, reduces flow Decrease superheat - Anti-clockwise turn, increases flow

Because each electronic TX valve can cover a huge capacity range, they are ideal for variable speed drive applications. By simulataneously adapting to superheat and capacity changes, they create the perfect balance of energy efficiency and system control. At Koldpak, we can select and supply the most appropriate valve for your application in an easy to install kit, including: Electronic Valve Valve controller Transformer Temperature probe Pressure transducer 3m interconnect cable Easy to follow instructions For expert advice on simple, effective power saving technology, call 07 3823 4026

AIR VALVES CONDITIONING UNIT MOUNTING BRACKETS EMERSON ELECTRONIC THERMOSTATIC EXPANSION VALVES - EX SERIES Emerson electrical control valves EX4, EX5, EX6, EX7 and EX8 are optimised for the control of liquid or gaseous mass flow in refrigeration systems. The stepper motor, which produces a precise valve opening, is energized directly from the electrical power and therefore operates independent from differential pressure ensuring stable operation at low condensing pressures. The valve seat and slider are made of solid ceramic for long life, low operating force, low internal leak rate and to eliminate corrosion. The positive shut off function and fast response time eliminate the need for an additional solenoid valve. The special shape of the valve slide provides for proper flow through the valve and a highly linear capacity characteristic between 10% and 100% of maximum capacity. Fully hermetic design Fast full stroke time Applicable to all common refrigerants (HCFC, HFC), for subcritical CO2 applications High resolution and excellent repeatability Bi-flow versions for heat pump applications Positive shut-off function to eliminate the use of an additional solenoid valve Linear flow capacity Wide capacity range (10-100%) Continuous modulation of mass flow, no stress (liquid hammering) in the refrigeration circuit Direct coupling of motor and valve for high reliability (no gear mechanism) Ceramic slide and port for accurate flow and minimal wear Balanced force design Corrosion resistant stainless steel body, and connections

AIR CONDITIONING UNIT MOUNTING BRACKETS VALVES EMERSON ELECTRONIC EXPANSION VALVE KITS DESCRIPTION INLET OUTLET CAPACITY RANGE Kw R 407C R 22 R 134a R 404A R 410A R 744 BDC0020 EX4-U31KIT BDC0040 EX5-U31KIT BDC0060 EX6-I31KIT BDC0080 EX7-U31KIT EX4-U31 Electronic Exp. Valve Kit EX5-U31 Electronic Exp. Valve Kit EX6-I31 Electronic Exp. Valve Kit EX7-U32 Electronic Exp. Valve Kit 5/8 5/8 2-17 2-17 1-13 1-12 2-19 3-34 7/8 7/8 5-53 5-50 4-39 4-35 6-58 10-102 1 1/8 1 1/8 15-126 15-120 10-93 10-84 15-140 24-244 1 3/8 1 3/8 35-347 35-330 25-255 25-230 40-385 70-670 Kits include Bi-flow valves with identical capacity in both flow directions, electronic driver, transformer, NTC probe, transducer and connection kit. For capacity conditions, application examples or other technical data, please contact us. ELECTRONIC EXPANSION VALVE PARTS DESCRIPTION BDC0100 EX4-U31 Alco EX4-U31 Electronic Exp. Valve BDC0120 EX5-U31 Alco EX5-U31 Electronic Exp. Valve BDC0140 EX6-I31 Alco EX6-I31 Electronic Exp. Valve BDC0160 EX7-U31 Alco EX7-U32 Electronic Exp. Valve BDC0180 TF20D 20VA Transformer To Suit EXV 230/24v BDC0200 XEV22D Dixell EXV Driver BDC0220 NT6-67 Dixell NTC 3m Probe Suit EXV BDC0240 PP11 Pressure Transducer -.5-11 Bar EXV BDC0260 EXV-M15 Plug and lead 1.5m kit for EEV EX4-8 BDC0280 EXV-M30 Plug and lead 3.0m kit for EEV EX4-8 Parts available in combined kit form. EXV-M30 EX5-U31 XEV22D NT6-67 PP11 TRANSDUCER

AIR VALVES CONDITIONING UNIT MOUNTING BRACKETS DENALINE ROTALOCK VALVES With 30 years of experience and over 1 million valves manufactured each year: Denaline has the figures, know-how and technology you d expect from a true leader. Based in Italy, Denaline manufacture, quality-control and test their products in house, which are then distributed worldwide.they are a leading name in Europe and are recognised as such by virtue of their strong focus on quality, safety, technology and the environment. DESCRIPTION ROTALOCK PIPE ID BDD0020 39304R Rotalock 3/4 RL x 3/8 Pipe 3/4 3/8 BDD0040 39307R Rotalock 3/4 RL x 1/2 Pipe 3/4 1/2 BDD0060 39009R Rotalock 1 RL x 3/8 Pipe 1 3/8 BDD0080 39007R Rotalock 1 RL x 1/2 Pipe 1 1/2 BDD0100 39008R Rotalock 1 RL x 5/8 Pipe 1 5/8 BDD0120 39107R Rotalock 1-1/4 RL x 1/2 Pipe 1 1/4 1/2 BDD0140 39105R Rotalock 1-1/4 RL x 5/8 Pipe 1 1/4 5/8 BDD0160 39108R Rotalock 1-1/4 RL x 3/4 Pipe 1 1/4 3/4 BDD0180 43304R Rotalock 1-1/4 RL x 7/8 Pipe 1 1/4 7/8 BDD0200 43306R Rotalock 1-1/4 RL x 1-1/8 Pipe 1 1/4 1 1/8 BDD0220 45506R Rotalock 1-3/4 RL x 7/8 Pipe 1 1/4 7/8 BDD0240 45507R Rotalock 1-3/4 RL x 1-1/8 Pipe 1 3/4 1 1/8 BDD0260 45508R Rotalock 1-3/4 RL x 1-3/8 Pipe 1 3/4 1 3/8 BDD0280 45505R Rotalock 1-3/4 RL x 1-5/8 Pipe 1 3/4 1 5/8 BDD0300 61502R Rotalock 2-1/4 RL x 1-5/8 Pipe 2 1/4 1 5/8 BDD0320 61503R Rotalock 2-1/4 RL x 2-1/8 Pipe 2 1/4 2 1/8

VALVES AIR CONDITIONING UNIT MOUNTING BRACKETS DENALINE PRESSURE RELIEF VALVES Individually certified, these Italian made pressure relief valves open gradually and reset quickly to minimise refrigerant loss in the event of an increase in pressure. DESCRIPTION CONNECTIONS INLET NPT OUTLET PSI BAR kpa BDE0020 DLD10/CS Pressure Relief Valve 1/2 3/4 435 30 3000 To meet increasingly demanding specifications, the Denaline Dual Shut-off Valve allows the isolation of individual pressure relief valves for servicing and testing. DESCRIPTION CONNECTIONS INLET NPT OUTLET BDE0040 77501S Three-Way Dual Shut-off Valve 1/2 2 X 1/2 RANCO 4 WAY REVERSING VALVE - 240V COIL & LEAD INCLUDED CONNECTIONS NOM KW (R22) NOM KW (R410A) DISCH. SUCT. MIN MAX MIN MAX TON BDF0020 V-2408064-2IL 3/8 1/2 2.6 7 3.2 7.7 2 BDF0040 V3-410084-7IL 1/2 5/8 3.5 9.8 4.2 10.9 3 BDF0060 V6-412084-1IL 1/2 3/4 3.5 19.3 4.2 23.5 6 BDF0080 V6-414084-1IL 1/2 7/8 3.5 19.3 4.2 23.5 6 BDF0100 V10-414084-2IL 1/2 7/8 15.8 34.8 19.7 41.8 10 BDF0120 V10-414124-2IL 3/4 7/8 15.8 34.8 19.7 41.8 10 BDF0140 V10-418144-2IL 7/8 1 1/8 15.8 39.4 19.7 47.5 10 BDF0160 V12-4220T4-2IL 1 1/8 1 3/8 21.1 49.2 26.4 59.1 12 * Capacity based on +7.2deg evaporating / 54.4deg condensing. Max capacity at 14kPa pressure drop

AIR VALVES CONDITIONING UNIT MOUNTING BRACKETS RANCO REPLACEMENT OIL DESCRIPTION BDF0200 RANL30-424801 Reversing Valve Coil 240v BDF0220 RAN9220000 Reversing Valve Coil 24v SHUT OFF VALVES CAPPED LINE VALVES FLARE FLARE BDG0020 1/4 BDG0040 3/8 BDG0060 1/2 BDG0080 5/8 BDH0020 1/4 BDH0040 3/8 BDH0060 1/2 BDH0080 5/8 BDG0100 1/4 BDG0120 3/8 BDG0140 1/2 BDG0160 5/8 BDH0100 1/4 BDH0120 3/8 BDH0140 1/2 BDH0160 5/8 DANFOSS CHECK VALVES FLARE TYPE BDI0020 020-1040 1/4 STRAIGHTWAY BDI0040 020-1041 3/8 STRAIGHTWAY BDI0060 020-1042 1/2 STRAIGHTWAY BDI0080 020-1043 5/8 STRAIGHTWAY BDI0100 020-1044 3/4 ANGLEWAY TYPE BDI0120 020-1010 1/4 STRAIGHTWAY BDI0140 020-1011 3/8 STRAIGHTWAY BDI0160 020-1012 1/2 STRAIGHTWAY BDI0180 020-1018 5/8 STRAIGHTWAY BDI0200 020-1019 3/4 ANGLEWAY BDI0220 020-1020 7/8 ANGLEWAY BDI0240 020-1021 1 1/8 ANGLEWAY BDI0260 020-1026 1 3/8 ANGLEWAY

AIR CONDITIONING UNIT MOUNTING BRACKETS VALVES EMERSON BALL VALVES - WITH ACCESS PORT The BVS Ball valve is a fully hermetic ball valve for the Refrigeration and A/C industry. Two threads at valve body for easy mounting Hermetic design Compatible with high pressure refrigerants such as R 410A and CO2 (sub-critical) Light weight design Virgin PTFE seat gaskets Bi-directional flow characteristics Valve cap retained by strap attached to main body Pressure relief port design Full flow design (minimal pressure drop) 1/4 Access port with schrader core BDJ0020 BVS-014 1/4 BDJ0040 BVS-038 3/8 BDJ0060 BVS-012 1/2 BDJ0080 BVS-034 5/8 BDJ0100 BVS-058 3/4 BDJ0120 BVS-078 7/8 BDJ0140 BVS-118 1 1/8 BDJ0160 BVS-138 1 3/8 BDJ0180 BVS-158 1 5/8 BDJ0200 BVS-218 2 1/8 TECHNICAL DATA Maximum allowable pressure PS Test pressure PT Burst pressure Medium temp. TS 45 bar 49,5 bar 225 bar -40 120 C (150 C short term) Construction Medium compatibility * Material Forged brass body, Copper extension tubes, Chrome plated ball HFC, HCFC, CO2, Mineral, Synthetic and Polyol-Ester (POE) lubricants Body CW617N, Copper Tubes CW 024A acc. EN12420 * BVS Ball valves are not released for use with caustic, poisonous or flammable substances.

AIR VALVES CONDITIONING UNIT MOUNTING BRACKETS DANFOSS CRANKCASE PRESSURE REGULATORS Crankcase pressure regulator type KVL is fitted in the suction line ahead of the compressor. KVL protects the compressor motor against overload during start-up after long standstill periods or after defrost periods (high pressure in evaporator). PART NO. FLARE BDK0020 034L0041 KVL12 1/2 BDK0040 034L0042 KVL15 5/8 PART NO. BDK0060 034L0043 KVL12S 1/2 BDK0080 034L0049 KVL15S 5/8 BDK0100 034L0045 KVL22S 7/8 BDK0120 034L0046 KVL28S 1 1/8 BDK0140 034L0052 KVL35S 1 3/8 DANFOSS EVAPORATOR PRESSURE REGULATORS KVP evaporator pressure regulators are fitted in the suction line of refrigeration and air conditioning systems. They are used to: Maintain a constant pressure equivalent to a constant temperature on the evaporator. Protect against a dangerously low evaporating pressure by throttling down when pressure falls below the set value. Differentiate the evaporating pressures in two or more evaporators in systems with one compressor. PART NO. FLARE BDL0020 034L0021 KVP12 1/2 1/2 BDL0040 034L0022 KVP15 5/8 PART NO. BDL0060 034L0023 KVP12S 1/2 BDL0080 034L0029 KVP15S 5/8 BDL0100 034L0025 KVP22S 7/8 BDL0120 034L0026 KVP28S 1 1/8 BDL0140 034L0032 KVP35S 1 3/8

AIR CONDITIONING UNIT MOUNTING BRACKETS VALVES DANFOSS SOLENOID VALVES Danfoss EVR valves are suitable for liquid, suction, and hot gas lines. They are compatible with a wide choice of coils for AC and DC and are designed for temperatures of up to 105 C. PART NO. FLARE FUNCTION PART NO. FUNCTION BDN0020 032F8107 EVR3 1/4 N/C BDN0040 032F8116 EVR3 3/8 N/C BDN0060 032F8072 EVR6 3/8 N/C BDN0080 032F8079 EVR6 1/2 N/C BDN0100 032F8095 EVR10 1/2 N/C BDN0120 032F8098 EVR10 5/8 N/C BDN0140 032F8101 EVR15 5/8 N/C BDN0160 032F1206 EVR3S 1/4 N/C BDN0180 032F1204 EVR3S 3/8 N/C BDN0200 032F1212 EVR6S 3/8 N/C BDN0220 032F1209 EVR6S 1/2 N/C BDN0240 032F1217 EVR10S 1/2 N/C BDN0260 032F1214 EVR10S 5/8 N/C BDN0280 032F1228 EVR15S 5/8 N/C BDN0300 032F1225 EVR15S 7/8 N/C BDN0320 032F1240 EVR20S 7/8 N/C BDN0340 032F2201 EVR25S 1 1/8 N/C BDN0360 042H1106 EVR32S 1 3/8 N/C BDN0380 042H1112 EVR40S 2 1/8 N/C * Above solenoid valves do not include coils. Please see below. DANFOSS SOLENOID COILS PART NO. CONNECTION TYPE VOLTS WATTS BDN0400 018F6702 IP67 Terminal Box 240AC 10 BDN0420 018F6252 With Lead 240AC 10 BDN0440 018F6730 IP67 Terminal Box 110AC 10 BDN0460 018F6706 IP67 Terminal Box 12AC 10 BDN0480 018F6707 IP67 Terminal Box 24AC 10 BDN0500 018F6856 IP67 Terminal Box 12DC 20 BDN0520 018F6857 IP67 Terminal Box 24DC 20 *To suit EVR Solenoid Valves

DRIERS DANFOSS LIQUID LINE FILTER DRIER DML Danfoss DML driers have a core composition of 100% Molecular Sieve making them ideal for applications requiring the highest moisture capacity. High drying capacity minimising the risk of acid formation The drier shell has a powder-painted corrosion resistant finish Sizes ranging from 3 75 cubic inches The filter is thermally stable up to 120 C. DANFOSS LIQUID LINE FILTER DRIER DML - FLARE PART NO. FLARE LIQUID CAPACITY KW R22 R134A R404A BDO0020 023Z5035 DML32 1/4 7.45 6.7 5.01 BDO0040 023Z5036 DML33 3/4 14.46 12.85 9.86 BDO0060 023Z5037 DML52 1/4 8.45 7.67 5.62 BDO0080 023Z5038 DML53 3/8 14.44 12.87 9.81 BDO0100 023Z5039 DML82 1/4 8.32 7.68 5.44 BDO0120 023Z5040 DML83 3/8 16.03 14.19 10.98 BDO0140 023Z5041 DML84 1/2 31.76 28.61 21.33 BDO0160 023Z5042 DML162 1/4 8.31 7.68 5.43 BDO0180 023Z5043 DML163 3/8 17.41 16.33 11.18 BDO0200 023Z5044 DML164 1/2 35.4 32.19 23.54 BDO0220 023Z5045 DML165 5/8 51.82 44.64 36.59 BDO0240 023Z0049 DML303 3/8 16.59 15.7 10.56 BDO0260 023Z0050 DML304 1/2 36.63 32.51 25 BDO0280 023Z0051 DML305 5/8 52.72 45.71 36.96 BDO0300 023Z0193 DML306 3/4 53.22 43.73 39.89 BDO0320 023Z0108 DML413 3/8 19.49 18.4 12.44 BDO0340 023Z0109 DML414 1/2 38.15 33.39 26.45 BDO0360 023Z0110 DML415 5/8 61.92 55.48 41.84

DRIERS DANFOSS LIQUID LINE FILTER DRIER DML - PART NO. LIQUID CAPACITY KW R22 R134A R404A BDO0460 023Z5048 DML32S 1/4 7.45 6.7 5.01 BDO0480 023Z5050 DML33S 3/8 14.46 12.85 9.86 BDO0500 023Z5053 DML52S 1/4 8.45 7.67 5.62 BDO0520 023Z5054 DML53S 3/8 14.44 12.87 9.81 BDO0540 023Z5057 DML82S 1/4 8.32 7.68 5.44 BDO0560 023Z5058 DML83S 3/8 16.03 14.19 10.98 BDO0580 023Z5061 DML84S 1/2 31.76 28.61 21.33 BDO0600 023Z5063 DML162S 1/4 8.31 7.68 5.43 BDO0620 023Z5064 DML163S 3/8 17.41 16.33 11.18 BDO0640 023Z5067 DML164S 1/2 35.4 32.19 23.54 BDO0660 023Z5068 DML165S 5/8 51.82 44.64 36.59 BDO0680 023Z0067 DML303S 3/8 16.59 15.7 10.56 BDO0700 023Z0068 DML304S 1/2 36.63 32.51 25 BDO0720 023Z0069 DML305S 5/8 52.72 45.71 36.96 BDO0740 023Z0070 DML306S 3/4 53.22 43.73 39.89 BDO0760 023Z0071 DML307S 7/8 75.4 64.25 53.95 BDO0780 023Z0111 DML414S 1/2 38.15 33.39 26.45 BDO0800 023Z0112 DML415S 5/8 61.92 55.48 41.84 BDO0820 023Z0113 DML417S 7/8 78.5 66.74 56.32 BDO0840 023Z0114 DML419S 1 1/8 109.42 95.3 76.29 ARI 710-2004: -15 c evaporating temp, 30 c condensing temperature and.07 bar

DRIERS DANFOSS BURNOUT DRIER DAS Danfoss DAS burnout driers are used in the suction line to clean up refrigeration and AC-systems with fluorinated refrigerants after a compressor motor burn-out. The solid core is composed of 70% activated alumina and 30% Molecular Sieve which works to absorb harmful acids as well as moisture. By absorbing these acids, the DAS burn-out filter drier protects the new compressor from premature failure. 2 Schrader access valves to measure pressure drop across the drier Sizes ranging from 8 to 60 cubic inches, The drier shell has a powder-painted corrosion resistant finish Allows installation in any position provided the flow is in the arrow direction PART NO. RATED CAPACITY KW Qe R22 R134A R404A BDO0940 023Z1009 DAS164S 1/2 10.5 6 8.5 BDO0960 023Z1008 DAS165S 5/8 15 9.5 13 BDO0980 023Z1012 DAS167S 7/8 22 13.5 19 BDO1000 023Z1013 DAS305S 5/8 18 11 15 BDO1020 023Z1014 DAS306S 3/4 22 14 19 BDO1040 023Z1015 DAS307S 7/8 26 16 22 BDO1060 023Z1016 DAS309S 1 1/8 31 20 27 Capacity is rated at 4 C evaporating temp,.21bar Capacities for other temperatures than 4 C are calculated by use of correction factors. Divide your actual evaporator capacity with the correction factor given for your actual evaporating temperature. Look up the capacity table for the necessary rated capacity. Qe/Fe = Qn Qe = Actual evaporator capacity Qn = Nominal capacity Fe = Correction factor Correction factors. Fe evaporating temperatures [ C] [ C] 4 0-5 -10-15 -20-25 -30-35 -40 Fe 1 0.9 0.75 0.6 0.5 0.4 0.35 0.25 0.2 0.15 Example To select a burn-out filter drier for a R134a plant with an evaporator capacity at 8.5 kw at -5 C you may use a burn-out filter drier with a rated capacity of 8.5/0.75 = 11.33 kw or bigger. For example DAS 305.

DRIERS DANFOSS BI FLOW DRIER DMB Bi-flow filter driers have built-in check valves which ensure that refrigerant liquid always flows through the filter driers from the outer side of the filter core towards the centre. Thus all dirt particles are retained irrespective of flow direction. DCB filter driers ensure fast and effective absorption of moisture as well as organic and inorganic acids. High drying capacity minimising the risk of acid formation Seamless core blend for systems operating at high condensing temperatures and require high drying capacity No dirt released by reversing the flow direction Sizes ranging from 8 30 cubic inches DANFOSS BI FLOW DRIER DMB - FLARE PART NO. FLARE LIQUID CAPACITY KW R22 R134A R404A BDO1160 023Z1412 DMB82 1/4 4.3 3.9 2.8 BDO1180 023Z1411 DMB83 3/8 8.2 7.4 5.3 BDO1200 023Z1410 DMB84 1/2 9.2 8.3 6 BDO1220 023Z1415 DMB163 3/8 20 18 13 BDO1240 023Z1414 DMB164 1/2 32 28 20 BDO1260 023Z1413 DMB165 5/8 40 37 29 DANFOSS BI FLOW DRIER DMB - PART NO. LIQUID CAPACITY KW R22 R134A R404A BDO1280 023Z1443 DMB82S 1/4 4.3 3.9 2.8 BDO1300 023Z1442 DMB83S 3/8 8.2 7.4 5.3 BDO1320 023Z1441 DMB84S 1/2 9.2 8.3 6 BDO1340 023Z1446 DMB163S 3/8 20 18 13 BDO1360 023Z1445 DMB164S 1/2 32 28 20 BDO1380 023Z1444 DMB165S 5/8 40 37 29 BDO1400 023Z1447 DMB307S 7/8 47 43 32 ARI 710-2004: -15 c evaporating temp, 30 c condensing temperature and.07 bar

DRIERS ESK FILTER DRIERS Solid cores are easily replaceable Drier can be used alternatively as a fine strainer element after removal of solid core Schrader fitting to measure pressure drop Steel connector fittings Epoxy coating for surface protection CORE BDO1580 FT1X-3/4 3/4 1 BDO1600 FT1X-22 7/8 1 BDO1620 FT1X-28 1 1/8 1 BDO1640 FT1X-35 1 3/8 1 BDO1660 FT1X-42 1 5/8 1 BDO1680 FT1X-54 2 1/8 1 BDO1700 FT1X-2.5/8 2 5/8 1 BDO1720 FT2X-35 1 3/8 2 BDO1740 FT2X-42 1 5/8 2 BDO1760 FT2X-67 2 5/8 2 DRIER CORES DESCRIPTION SUITABILITY MATERIAL BDO2999 Suction Mesh Filter All refrigerants. Reuseable Stainless steel BDO3000 Core Standard General Clean Up All Round Clean-up (not recommended for POE oil) 80%MS, 20%AL BDO3020 Core Burn-Out Complete Clean Up Not recomended for long time use especially with POE 60%MS, 35%AL, 5%AC BDO3040 Core Ultra Drier HD Moisture Ideal for POE 100% MS MS = Molecular sieve AL = Activated Alumina AC = Activated Carbon

SIGHT GLASS DANFOSS MOISTURE INDICATOR - SIGHT GLASS SGN Sight glasses are used to indicate: 1. The condition of the refrigerant in the liquid line of the plant. 2. The flow in the oil return line from the oil separator. 3. The moisture content in the refrigerant. The Danfoss SGN are equipped with sensitive indicators that reflects a colour, depending on the moisture content in the refrigerant. Indicates excess water content in the refrigeration system Indicates lack of subcooling DANFOSS MOISTURE INDICATOR - SIGHT GLASS - FLARE NO. BRAND FLARE BDP0020 014-0161 SGN6 1/4 BDP0040 014-0162 SGN10 3/8 BDP0060 014-0163 SGN12 1/2 BDP0080 014-0165 SGN16 5/8 BDP0100 014-0166 SGN19 3/4 DANFOSS MOISTURE INDICATOR - SIGHT GLASS - NO. BRAND BDP0120 014-0181 SGN6S 1/4 BDP0140 014-0182 SGN10S 3/8 BDP0160 014-0183 SGN12S 1/2 BDP0180 014-0184 SGN16S 5/8 BDP0200 014-0185 SGN19S 3/4 BDP0220 014-0186 SGN22S 7/8 DANFOSS MOISTURE INDICATOR - SIGHT GLASS - MALE/FEMALE NO. BRAND MALE/ FLARE BDP0240 014-0171 SGN6 1/4 BDP0260 014-0172 SGN10s 3/8 BDP0280 014-0173 SGN12 1/2 BDP0300 014-0174 SGN16 5/8 BDP0320 014-0175 SGN19 3/4

VIBRATIONELIMINATORS PACKLESS VIBRATION ELIMINATORS Vibration Eliminators can be installed in both suction and discharge line of air conditioning, heat pump and refrigeration systems. The function of a vibration eliminator is to absorb the vibrations caused by the compressor. Ø D1 L (+/ 5) inch mm BDQ0020 VAF3 3/8 250 BDQ0040 VAF4 1/2 270 BDQ0060 VAF5 5/8 290 BDQ0080 VAF6 3/4 270 BDQ0100 VAF8 7/8 330 BDQ0120 VAF9 1 1/8 370 BDQ0140 VAF10 1 3/8 420 BDQ0160 VAF11 1 5/8 432 BDQ0180 VAF82 2 1/8 508 BDQ0200 VAF83 2 5/8 610