Quality makes the Difference. AquaTREND uni. User s Manual Humidifi er for Therapeutic Air Flow

Similar documents
Serial Number. In case of any query or complaint, please always state the serial number. Conformity

1 Intended Use of the Breas HA 01 Humidifier

User guide User guide English

E8/E80 Quick Reference Guide

E6/E60 Quick Reference Guide

COOL TOUCH ELECTRIC WATER KETTLE

Model S06HS Imported by Maranatha Pty Limited Unit 33 / 9 Hoyle Avenue, Castle Hill, N.S.W. 2154

I N S T R U C T I O N S

LINE. Patient compass. Welcome Guide English. Your guide to the therapy device

Ultrasonic Humidifier User s Manual

EVAPORATIVE COOL MIST HUMIDIFIER Instruction Manual

IMPRESSA A9 One Touch Quick Reference Guide

Ultrasonic Humidifier

Z8 Quick Reference Guide

SOMNOcomfort 2e SOMNOaqua. CPAP unit from SN SOMNOcomfort 2e with SOMNOaqua. Description of the equipment and instructions for use

User s Guide ENGLISH. Other languages available on our website:

INSTRUCTION MANUAL. Full Size Gas Convection Oven

PLEASE READ BEFORE USE AND SAVE. Ultrasonic. with Ionization. INSTRUCTION MANUAL MODEL HUNi

S8 Quick Reference Guide

Bipap A30/40 ventilator and System One humidifier

ph Measuring System Start-up and maintenance manual e Contents

Short Instruction for Use for in-home care ASSKEA procuff M and ASSKEA procuff S

Table of Contents. English

GoodKnight H 2 O. User's Manual. Heated Humidifier. Ref. : M-146DFU00-20 Revision D

Operating & Installation Instructions Fully Automatic Washing Machine (Household Use)

MODEL 7000 SUCTION UNIT

Remote alarm case VENTIremote alarm 10 m WM VENTIremote alarm 30 m WM Device description and instructions for use

IMPRESSA F7 Quick Reference Guide

AutoSet AutoSet for Her Elite Escape Auto Escape. H5i H5i for Her. Welcome Guide. English. POSITIVE AIRWAY PRESSURE DEVICEs HEATED HUMIDIFIER

VPAP COPD. H5i. Welcome Guide. Making quality of care easy. Respiratory Care Solutions. English NONINVASIVE VENTILATOR HEATED HUMIDIFIER

CPAP 20 CLICK 2. CPAP unit. Description of the equipment and instructions for use for devices from SN 65000

HC12W COOL MIST ULTRASONIC HUMIDIFIER OWNER S MANUAL. Read and save these instructions.

CLEAN MIST SMART HUMIDIFIER Instruction Manual and Warranty Information IM0031B READ AND SAVE THESE INSTRUCTIONS

Charlotte CRT20AB, Charlotte CRT20BR & Brookline BKL20

AlcoBlow. User Handbook

FOR THE FOLLOWING MODELS: If you have any questions about the operation of your ultrasonic humidifier, please contact Crane Customer Care.

THE MEDIX Actineb. Technical Specifications. % Particles < 5 um 75% * Class II BF. Intermittent (use for 60 Type Rating

CLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0040A

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

1.5 GALLON ULTRASONIC HUMIDIFIER MODEL # EE-5303W

ULTRASONIC HUMIDIFIER WITH ANTIBACTERIAL TANK & BASE Instruction Manual and Warranty Information IM0012A READ AND SAVE THESE INSTRUCTIONS

BIDET CLEANER. Owner s Guide MODEL EM-307. Please read all instructions before use. KEEP YOUR RECEIPT FOR WARRANTY PURPOSES.

PD-811 PD-811 propriétaire Owner s manual Manuel du PD D P

DIGITAL ULTRASONIC HUMIDIFIER WITH HUMIDISTAT

Personal humidifier UHW

CLEAN MIST DUAL TANK SMART HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0036A

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

Ultra Quiet USE AND CARE MANUAL IMPORTANT!

heated humidifier H5i Welcome Guide English

smardy - pure water Reverse osmosis system YR100-A 75 GPD

Transcend Heated Humidifier User Manual

ULTRASONIC DIGITAL HUMIDIFIER Instruction Manual and Warranty Information IM0002A READ AND SAVE THESE INSTRUCTIONS

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

IM-440C IM-660C IM-1108C

CLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0036A

SHARP SERVICE MANUAL

ULTRASONIC HUMIDIFIER MODEL# BU6000 INSTRUCTION MANUAL

Owners Manual. Model MINI-CLASSIC CT. Pure Water. Water Distiller

CLEAN MIST SMART HUMIDIFIER Instruction Manual and Warranty Information IM0002E READ AND SAVE THESE INSTRUCTIONS

Z6 Quick Reference Guide

1 GALLON / 3.78 LITER ULTRASONIC HUMIDIFIER

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:

Electric steam steriliser

Margo Moo TM and Digger Dog TM Steam Inhaler Guidebook

CLEAN MIST SMART HUMIDIFIER TABLETOP & FLOOR STANDING WITH REMOTE CONTROL. Instruction Manual and Warranty Information

USER MANUAL 03-0_MOD-KH1203US_H5_H5.indb _MOD-KH1203US_H5_H5.indb /11/08 21:28: /11/08 21:28:13

Thank you for purchasing the Ionmax Serene ION138 Ultrasonic Aroma Diffuser. The Ionmax Serene reintroduces moisture into the air to help you

Oxygen measuring device Operating manual

Ultrasonic Aroma Diffuser AD-SD1-CE

wc431 Slimline Integrated Dishwasher Manual for Installation, Use and Maintenance

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

PERSONAL Ultrasonic Cool Mist Humidifier

Midi Dehumidifi er IMPORTANT! KEEP FOR FUTURE REFERENCE. Instruction Manual. Please register your product on-line at

ULTRASONIC HUMIDIFIER

Electronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user

Betriebsanleitung Operating instructions Manuel d utilisation GS 402


DreamStation Go. Heated Humidifier. User manual. Instructions for use

2 in 1 steam and blend

OMNIVAC secretion aspiration system Description of device and instructions for use

Short Instructions TNI 20 oxy

Glass and Dishwashers. BarAid 500/800. Installation and. Starting from Serial No.:

1 GALLON / 3.78 LITER ULTRASONIC HUMIDIFIER

pure indoor living DIGITAL ULTRASONIC HUMIDIFIER MODEL: BU7500 INSTRUCTION MANUAL

Instruction Manual and Warranty Information

h is ngl E ASSISTANCE CENTRE AUTHORIZED RETAILER

Ultrasonic Humidifier

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

87cm. Cooker hood. Stainless steel JLCEILHD87. User guide

Portable Ice Maker User Guide

ULTRASONIC AIR SALINIZER. Owner s Manual. Saltair Home Salt Therapy

Operating manual. a Look Solutions 1 product

PERSONAL COOL MIST ULTRASONIC HUMIDIFIER

Instructions for use. BA Optima. Air motors BA602 (BA640081) BA604 (BA640060)

VPAP Auto VPAP ST VPAP S. H5i. Welcome Guide. English POSITIVE AIRWAY PRESSURE DEVICE HEATED HUMIDIFIER

CP002E, CP005E, CP015E, CP006E, CP007E

System One Heated Humidifier USER MANUAL

AW 20 S OPERATING MANUAL AIR WASHER TRT-BA-AW20S-TC-004-EN

Instructions for use. 301 plus

Transcription:

Quality makes the Difference AquaTREND uni User s Manual Humidifi er for Therapeutic Air Flow

SERIAL NUMBER HOFFRICHTER GmbH delivers all its systems with a serial number in order to ensure traceability. The serial number is indicated on the type label on the bottom of the system. Please always specify the serial number in inquiries and complaints. CONFORMITY The device complies with the requirements of the Directive 93/42/EEC. 2 Info

TABLE OF CONTENTS Legend of Symbols... 4 Safety Instructions... 5 Technical Description... 8 Operation of the Device... 10 Cleaning... 13 Troubleshooting... 15 Disposal... 16 Humidifi er... 16 Packaging... 16 Technical Data... 17 Table of Contents 3

LEGEND OF SYMBOLS Observe the accompanying documentation Applied part type BF Electric safety class II (with protective insulation) CE Declaration of Conformity Manufacturer Observe the User s Manual Caution! Hot! Do not dispose of the device with normal domestic waste. For information on the proper disposal of the device, please contact your responsible customer service. 4 Legend of Symbols

SAFETY INSTRUCTIONS Before using your AquaTREND uni for the fi rst time, please thoroughly read these User s Manual. Keep these User s Manual at a safe place for immediate consultation, if necessary. For the period stipulated by law, HOFFRICHTER GmbH warrants that the product is free from any defects provided it is used as intended. HOFFRICHTER GmbH is not liable for any damage and consequential damage nor for any effects on the safety, reliability and performance of the device, if: manipulations, modifi cations, expansions, adjustments, repairs and maintenance measures are carried out by persons not authorized by us to do so use is made of accessories and spare parts which come from other manufacturers and have not been released by us for use with the point the device is used in a way that is different from that described in the User s Manual the hygiene and cleaning instructions contained in these User s Manual fail to be observed Safety Instructions 5

In order to prevent potential hazards, please follow the instructions below: Use the humidifi er in combination with a respiration therapy device of the TREND II series only and observe all instructions for use given for that device. Use accessories only which have been recommended and offered by your specialized dealer. Do not operate the humidifi er if it is damaged or not working properly. If that is the case, please immediately notify your specialized dealer. Place the device on a fi rm and fl at surface, avoid an inclined position of the device during operation. Never transport or tilt the respiration therapy device if the humidifi er is attached and fi lled. This might cause water to enter the therapy device and thus damage it. Do not expose the therapy device to direct sunlight or set it up near heaters or similar if the humidifi er is attached and fi lled. Change the water everyday to prevent the spread of bacteria and germs. 6 Safety Instructions

INTENDED USE AquaTREND uni is used for humidifying the therapy air fl ow which is supplied to the patient. Use the humidifi er only together with TREND II devices. The water used for humidifying must not contain any additives such as medication, salt, aroma oil or any other substances. Intended Use 7

TECHNICAL DESCRIPTION The device is a warm air humidifi er which can be mounted on devices of the respiration therapy line TREND II. It is intended to humidify the therapy air fl ow with moisture to prevent the mucous membranes of the upper respiratory tract from becoming dry. The heater output can be adjusted in fi ve levels thus allowing the device to be adjusted to the individual patient s requirements. When turning off the therapy device or taking off the humidifi er the device saves the heating level that was set last. 8 Technical Description

DEVICE DESCRIPTION 1 Air outlet (connection for therapy tube) 2 Cap 3 Air guide 4 Air inlet 5 Contact pins 6 Reservoir with heating surface Device Description 9

OPERATION OF THE DEVICE Rinse the humidifi er thoroughly with clean fresh water prior to its fi rst use. Do this as described in the chapter Cleaning from page 13. When fi lling the humidifi er it must be disconnected from the therapy device. Open the humidifi er by turning the cap in anti-clockwise direction and removing it from the water reservoir (see illustration on page 13). Fill the humidifi er with cold distilled water for medical applications or boiled cold water with a low lime in contact. The water must be cold and contain no additives. Fill in the water only up to the specifi ed maximum fi lling level. Close the water reservoir again by placing the cap onto the water reservoir with slightly pressure and turning it in clockwise direction until it stops. While carrying the fi lled humidifi er please keep hold of the reservoir. 10 Operation of the Device

Never tilt or turn over the humidifi er after fi lling it. When connecting the humidifi er with your respiration therapy device please observe the following instructions: Place the contact pins and air inlet of the humidifi er on the therapy device without twisting or canting them. The release button has to snap in place audibly. Operation of the Device 11

The heating power can be set to fi ve levels at the therapy device. For starting operation of the humidifi er push the heater key on the TREND II device. The display now shows the currently set heating level and the heater LED lights. After starting the operation of the device with the control key the heating level will be continuously be displayed. If you interrupt or end the therapy with the control key the heater LED will fl ash and the humidifi er is set to standby. For changing the heating level press down the heater key for approx. 1 second until the heater menu is displayed. By pressing the key the heating level can be selected. You can now set the heating level with the help of the key and (higher level = higher temperature). Confi rm by pressing. CAUTION! Operating the blower when the humidifier is filled but the therapy tube is disconnected may cause water droplets to be swept along in the air flow. Therefore the therapy tube should always be firmly in place before switching on the humidifier. 12 Operation of the Device

2 1 CLEANING Please carefully follow the hygiene and cleaning instructions in order to preserve your health and to avoid disturbances and failures. Except from cleaning it regularly, the device requires no further maintenance. The regular, daily cleaning prevents the built-up of limescale which is diffi cult to remove. Press the release button, separate the humidifi er from the therapy device, and take the humidifi er to a sink. Open the humidifi er by turning the cap anti-clockwise and removing it from the water reservoirs (1). ATTENTION! Never use sharp or pointed objects for cleaning the humidifier. 33 Empty the water reservoir and rinse it with running water(2). Remove any limescale by wiping it with a soft cloth (3). If tough limescale has built up we recommend using normal limescale remover or fi lling the water reservoir with a thin vinegar solution and let it soak for a while. Then empty the reservoir, wipe off any residue limescale with a soft cloth and then rinse the reservoir thor- Cleaning 13

oughly under running water. Before cleaning the cap remove the air guide as shown (4). It is suffi cient to rinse the device daily with running water. It is important to let the humidifi er dry completely after cleaning it. Do not refi ll it before it has not dried out completely. You can also clean the water reservoir and the cap in the dishwasher at a temperature of up to 60 C. However, we recommend thoroughly rinsing it with running water to avoid deposition of food leftovers from the dishwasher. A chemical or heat disinfection of the humidifi er by the user is not required and is not recommended. AquaTREND uni is intended for use by only one patient. Before using it for another patient it has to be professionally sanitized. Please take the humidifi er to your specialized dealer to have it sanitized. 4 14 Cleaning

TROUBLESHOOTING Problem Water in the therapy tube No or insuffi cient humidifi - cation Selected heating level is not displayed Water is escaping from the air outlet Remedy The heating has been set too high, select a lower heating level. Run the tube under the blanket. Select a higher heating level. Check if the contact pins have been inserted into the respiration therapy device all the way and if the release button has fi rmly snapped into place. The respiration therapy device has to be switched on. Check if the water reservoir has been fi lled beyond the maximum fi lling level. Troubleshooting 15

DISPOSAL HUMIDIFIER For the proper disposal of the device please contact your specialized dealer. PACKAGING Your specialized dealer will take back the packaging, however, you can also separate the packaging according to material and dispose of it in your normal domestic waste. 16 Disposal

TECHNICAL DATA Dimensions (W x D x H) 110 x 150 x 125 mm Mass without water approx. 350 g Operational voltage 24 V DC Electrical power 0 20 W Heating level 1 4 W Heating level 2 8 W Heating level 3 12 W Heating level 4 16 W Heating level 5 20 W Relative humidity fl ow level 1 level 5 4 hpa 16 l/min > 75 % 100% 10 hpa 26 l/min > 65 % > 90% 20 hpa 36 l/min > 50 % > 70% Dispensary of the humidifi er (Heat level 5) Values measured at 22 C and 55 % rel. air humidity 4 hpa : 16 l/min : 13 mg/l 20 hpa : 36 l/min : 10 mg/l Values measured at 24 C and 35 % rel. air humidity NOTE: The humidification ratio can vary at different ambient conditions. Technical Data 17

Max. capacity approx. 300 ml Max. water temperature 43 C Classifi cation acc. to EN 60601-1 Safety class II, device type BF Operating temperature + 5 C... + 35 C Storage temperature - 40 C... + 70 C Rel. air humidity 15... 95 % Operating altitude (altitude above MSL) - 400 m... 3500 m (1060 hpa... 700 hpa) Air Outlet 22 mm, conus (acc. to ISO 5356-1) CE mark according to EC Directive 93/42/EEC, device in compliance with MDD, Class IIa Technical specifi cations are subject to technical modifi cations. 18 Technical Data

NOTES Notes 19

HOFFRICHTER GmbH Mettenheimer Straße 12 / 14 19061 Schwerin Germany Telephone: +49 385 39925-0 Telefax: +49 385 39925-25 E-Mail: info@hoffrichter.de www.hoffrichter.de AquaTREND uni-eng-0809-03