RCHITECTS ENGINEERS, INC. MECHNICL M-1 MECHNICL NOTES, SCHEDULES, ND DETILS OVERLL UILDING PLN PLUMING (Y OTHERS) P-1 PLUMING PLN SCLE: N.T.S. ELECTRICL (Y OTHERS) E-1 ELECTRICL PLN 370 15th ve S; Units & Florida Certificate of uth No: 00009393 Florida License No.: 26000952 CRIG. SOMMERS, I RCHITECT - R0016480 RCHITECTURL G-1 CODE DT G-2 LIFE SFETY PLN -1 FLOOR PLN -2 REFLECTED CEILING PLN -3 POWER PLN -4 CCESSIILITY GUIDELINES SCLE: N.T.S. 800 MYPORT ROD TLNTIC ECH, FLORID 32233 STREET MP R&P TECHNOLOGIES PROJECT LOCTION NOTE : EXIT DOOR TCTILE SIGNGE REDING: EXIT SIGNGE SHLL COMPLY w/nsi/co 117.1; MOUNT 60" FF TO CENTERLINE OF SIGN LOCTION OF SIGN SHLL COMPLY WITH FC-CCESSIILITY 703 SIGNS SHLL E THE RESPONSIILITY OF THE INDIVIDUL TENNTS S PRT OF THEIR UILD-OUTS SYSTEM (FC TLE 1006.2.1); NFP 101-75 FT (USINESS) PROJECT LOCTION INDICTES EXIT OR EXIT CCESS, NUMER OF PERSONS (P) DISCHRGING T EXIT OR EXIT CCESS, ND EGRESS CLER WIDTH (T DOORS). DUVL COUNTY MP SMPLE EGRESS TRVEL PTH ND DISTNCE EXISTING & NEW ONE-HOUR FIRE RTED WLL FIRE EXTINGUISHER (UL RTING 3-40:C) 5 L MULTIPURPOSE DRY CHEMICL EQUL TO DGER MODEL #5M-6H ( KIDDE COMPNY) FIRE EXTINGUISHERS SHLL E CERTIFIED Y LICENSE FIRE PROTECTION COMPNY FIRE EXTINGUISHERS SHLL E INSTLLED Y TENNTS IN THEIR LESED SPCES CLSS FIRES (ORDINRY COMUSTILE MTERILS SUCH S WOOD, CLOTH, PPER RUER ND MNY PLSTICS) CLSS FIRES (LIQUIDS, TRS, OILS, GSES) CLSS C FIRES (ELECTRICL EQUIPMENT) NOT TO SCLE REVISION DTE LOCKS ON EXIT DOORS SHLL NOT REQUIRE THE USE OF KEY, TOOL OR SPECIL KNOWLEDGE OR EFFORT FOR OPERTION FROM EGRESS SIDE UNLESS THEY MEET THE REQUIREMENTS OF NFP 101 7.1.2.5. NO. TITLE: CODE DT PROJECT SITE DRWN Y: CS CHECKED Y: CS DTE: 11-05-18 SITE VICINITY PLN SCLE: N.T.S. MXIMUM FLOOR RE PER UNIT OF = 1,500 SF MXIMUM FLOOR RE PER 2 UNIT = 3,000 SF MXIMUM TRVEL DISTNCE TO N EXTINGUISHER = 75 FT MXIMUM FLOOR RE PER EXTINGUISHER = 11,250 SF DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT ND OTHER PROPERTY RIGHTS IN THESE DRWINGS. THESE DRWINGS, PLNS & DESIGNS RE NOT TO E REPRODUCED, COPIED OR USED IN NY MNNER WITHOUT EXPRESSED WRITTEN PERMISSION ND CONSENT OF RCHITECTS ENGINEERS, INC. THESE PLNS SHLL NOT E DISTRIUTED TO NY PRTY WITHOUT SID WRITTEN PERMISSION & CONSENT. G-1
46' ROOM 102 LIFE SFETY PLN SCLE: 1/4"= 1'-0" ROOM 107 FE HI-LO DF ROOM 103 160P 32" NOTE 36' ROOM 104 FE ROOM 106 ROOM 105 160P 32" NOTE DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT ND OTHER PROPERTY RIGHTS IN THESE DRWINGS. THESE DRWINGS, PLNS & DESIGNS RE NOT TO E REPRODUCED, COPIED OR USED IN NY MNNER WITHOUT EXPRESSED WRITTEN PERMISSION ND CONSENT OF RCHITECTS ENGINEERS, INC. THESE PLNS SHLL NOT E DISTRIUTED TO NY PRTY WITHOUT SID WRITTEN PERMISSION & CONSENT. DRWN Y: CS CHECKED Y: CS DTE: 11-05-18 G-2 TITLE: LIFE SFETY PLN NO. DTE REVISION R&P TECHNOLOGIES 800 MYPORT ROD TLNTIC ECH, FLORID 32233 RCHITECTS ENGINEERS, INC. 370 15th ve S; Units & Florida Certificate of uth No: 00009393 Florida License No.: 26000952 CRIG. SOMMERS, I RCHITECT - R0016480
WLL LEGEND RRIER-FREE CYLINDRICL LEVER SET DESIGN RRIER-FREE CYLINDRICL LEVER SET DESIGN INTERIOR CONCRETE SL INSTLLTION 1. #4 x 12" LONG DOWELS @ 36" O.C. W/6" IN THE EXISTING SL ND 6" IN THE NEW SL - NCHOR DOWELS INTO EXISTING SL, TYP. TRENCHES LESS THN 12" DO NOT REQUIRE DOWELS. TRENCHES LESS THN 24" SHLL HVE DOWELS @ 36" O.C. ON ECH SIDE OF THE TRENCH. THE DOWELS SHLL E INSTLLED IN STGGERED PTTERN OFFSET 18" ON ECH SIDE OF THE TRENCH. TRENCHES GRETER THN 24" SHLL HVE DOWELS @ 36" O.C. ON ECH SIDE OF THE TRENCH. 2. NEW 4" CONCRETE SL ON GRDE (TO MTCH EXISTING; FIELD VERIFY) W/6 x 6-1.4 x 1.4 WWF REINFORCING OVER 10 MIL POLY VPOR RETRDER, TRETED & COMPCTED SOIL 4,000 PSI, 145 PCF DENSITY, 0.45 MX W/C RTIO 1. PROVIDE FIRELOCKING ND DRFTSTOPPING IN PRTITIONS PER FC 717. PROVIDE FIRELOCKING IN CONCELED WLL SPCES INCLUDING VERTICLLY T THE CEILING ND FLOOR LEVELS ND HORIZONTLLY T INTERVLS NOT EXCEEDING 10' (IC 717.2.2). SEE IC 717.2.1 FOR FIRELOCKING MTERIL OPTIONS. 2. EXPOSED INSULTION MTERILS INSTLLED SHLL HVE FLME SPRED RTING OF NOT MORE THN 25 ND SMOKE DEVELOPED RTING OF NOT MORE THN 450 S DETERMINED IN CCORDNCE WITH STM E 84. 3. CONCELED INSULTION MTERILS INSTLLED SHLL HVE FLME SPRED RTING OF NOT MORE THN 75 ND SMOKE DEVELOPED RTING OF NOT MORE THN 450 S DETERMINED IN CCORDNCE WITH STM E 84. 4. PROVIDE MOISTURE RESISTNT GYPSUM ORD ROUND PLUMING FIXTURES ND WLLS TO RECEIVE CERMIC TILE. 5. PROVIDE FIRE-RERDNT WOOD LOCKING IN WLL S REQUIRED TO SUPPORT TOILET ROOM FIXTURES, CCESSORIES, SHELVES & CINETS, WLL MOUNTED TELEVISIONS ND FIRE EXTINGUISHERS. COORDINTE LOCTIONS OF CEILING & WLL MOUNTED TELEVISIONS WITH TENNT IN FIELD. 6. PROVIDE R-11 SOUND TTENUTION TT ROUND THE TOILET ROOM. CRIG. SOMMERS, I RCHITECT - R0016480-6" 25 G METL STUDS @ 24" O.C. W/ (1) LYER OF 1 2" GW ON ECH SIDE TO OTTOM OF INSULTION (VRIES - 12'-0" TO 13'-6") W/ R-13 INSULTION FINISH FINISH TO 6" OVE CEILING ELEVTION IN TPE ND ED ONLY ON OPPOSITE SIDE RCE WLL TO LIMIT DEFLECTION TO L/240 INTERIOR SIDE ONLY PINTED WITH VINYL SE - 3-5/8" 25 G METL STUDS @ 24" O.C. W/ (1) LYER OF 1 2" MOISTURE RESISTNT GYPSUM WLLORD ON ECH SIDE TO 6" FF W/ SOUND TT INSULTION OTH SIDES PINTED WITH VINYL SE C - 3-5/8" 25 G METL STUDS @ 24" O.C. W/ (1) LYER OF 1 2" GW ON ECH SIDE TO OTTOM OF INSULTION (VRIES - 12'-0" TO 13'-6") W/ R-13 INSULTION FINISH FINISH TO 6" OVE CEILING ELEVTION ON ROOMS 103, 104, 105, 106, 107 SIDE TPE & ED ONLY ON OPPOSITE SIDE RCE WLL TO LIMIT DEFLECTION TO L/240 INTERIOR SIDE ONLY PINTED WITH VINYL SE D - 3-5/8" 25 G METL STUDS @ 24" O.C. W/ (1) LYER OF 1 2" GW ON ECH SIDE TO 10' FF W/ SOUND TTENUTION TT INSULTION RCE WLL TO LIMIT DEFLECTION TO L/240 OTH SIDES PINTED WITH VINYL SE WLLS WITHIN 2'-0" OF SERVICE SINKS, URINLS & WTERCLOSETS SHLL HVE SMOOTH NONSORENT SURFCE TO HEIGHT OF 4'-0" OVE THE FLOOR RCHITECTS ENGINEERS, INC. 370 15th ve S; Units & Florida Certificate of uth No: 00009393 Florida License No.: 26000952 E - REMOVE EXISTING DOULE DOORS ND INFILL OF REMINING WLL W/ 3-5/8" 25 G METL STUDS T 24" O.C. W/ (1) LYER OF 1 2" GW ON ECH SIDE TO MTCH OTH SIDES PINTED WITH VINYL SE. F - NEW PONY WLL OVE EXISTING WLL SYSTEM FROM TOP OF EXISTING WLL TO 6" OVE CEILING ELEVTION OF ROOMS 103 & 107 3-5/8" 25 G METL STUDS T 24" O.C. W/ (1) LYER OF 1 2" GW ON ECH SIDE. FINISH FINISH TO 6" OVE CEILING ELEVTION ON ROOMS 103 & 107 SIDE TPE ND ED ONLY ON OPPOSITE SIDE RCE WLL TO LIMIT DEFLECTION TO L/240 G - EXISTING TENNT SEPRTION WLL TO REMIN ( 1 2" TYPE X DRYWLL OTH SIDES OVER 2X4 FRMING) V - EXISTING WLL TO REMIN - NO WORK W - EXISTING WLL TO REMIN - PTCH S NEEDED PINT OTH SIDES WITH VINYL SE X - EXISTING WLL TO REMIN - PTCH S NEEDED PINT INTERIOR SIDE WITH VINYL SE ROOM 102 ROOM 107 ROOM 103 ROOM 104 ROOM 106 ROOM 105 R&P Technologies 800 MYPORT ROD TLNTIC ECH, FLORID 32233 Y - EXPOSED COLUMN - FRME ND WRP WITH DRYWLL TO MTCH EXISTING PINT INTERIOR SIDE WITH VINYL SE Z - EXISTING WLL - REMOVE EXISING CCENT FINISH ND REPLCE W/ 1 2" DRYWLL PINT EXISTING SIDE WITH VINYL SE DOOR & WINDOW SCHEDULE SCHEDULE 1-3'-0" X 6'-8" SOLID CORE IRCH DOOR WITH HOLLOW METL FRME PRIVCY LOCKSET, (3) HINGES, SILENCERS, CLOSER, KICKPLTE, WLLSTOP 2-3'-0" X 6'-8" SOLID CORE IRCH DOOR WITH HOLLOW METL FRME PSSGE LOCKSET, (3) HINGES, SILENCERS, WLLSTOP 3-3'-0" X 6'-8" SOLID CORE IRCH DOOR WITH HOLLOW METL FRME OFFICE LOCKSET, (3) HINGES, SILENCERS, WLL STOP 4-3'-0" X 6'-8" SOLID CORE IRCH DOOR WITH HOLLOW METL FRME OFFICE LOCKSET, (3) HINGES, SILENCERS, FLOOR STOP 5-3'-0" X 6'-8" SOLID CORE IRCH DOOR WITH HOLLOW METL FRME OFFICE LOCKSET, (3) HINGES, SILENCERS, WLL STOP 6 - EXISTING STOREFRONT DOOR. REMOVE PUSH/PULL HNDLES, LOCK IN PLCE (INOPERLE) 7 - EXISTING STOREFRONT DOOR TO REMIN 10 - EXISTING INTERIOR WINDOW TO REMIN 11 - EXISTING EXTERIOR WINDOW TO REMIN (TYP) DOOR SPECIFICTIONS & FINISHES (OR EQUL) HINGES - HGER 1279 4-1/2" X 4= 1 2" US26D LOCKSETS - S. PRKER HRDWRE - OFFICE SL7160 626, PRIVCY SL 7160P 626 CLOSER2 - FLCON SC61 X L WLL STOPS - ROCKWOOD 409 US32D FLOOR STOPS - ROCKWOOD 441 US26D KICK PLTES - 8X34 US32D FRMES - KNOCK DOWN OR WELDED, CONTRCTOR'S OPTION DOORS - SOLID CORE WOOD - IRCH FLOOR PLN SCLE: 1/4"= 1'-0" ROOM FINISHES WLLS - PINTED - EPOXY PINT SE - VINYL SE FLOOR - VCT CEILING - CT - RMSTRONG 15 16 PRELUDE XL GRID W/ FINE FISSURED SQURE LY IN 2X4 TILE - EVEN WITH TOP OF EXISTING WLL X (+/- 8'-0" FF) NOTE - WLLS WITHIN 2'-0" OF SERVICE SINKS, TOILETS, & URINLS SHLL HVE SMOOTH NONSORENT SURFCE TO HEIGHT OF 4'-0" FF ROOM 102 WLLS - PINTED (EXISTING TO REMIN) SE - VINYL SE FLOOR - CRPET CEILING - PINTED (EXISTING TO REMIN) OTHER - EXISTING WLLS ND CEILING TO REMIN ROOMS 103 / 104 / 105 WLLS - PINTED SE - VINYL SE FLOOR - CRPET CEILING - CT - RMSTRONG 15 16 PRELUDE XL GRID W/ FINE FISSURED SQURE LY IN 2X4 TILE - EVEN WITH TOP OF EXTERIOR WINDOWS (+/- 9'-0" FF) ROOMS 106 WLLS - TPED ND FINISHED DRYWLL SE - NONE FLOOR - NONE CEILING - NONE ROOMS 107 WLLS - PINTED SE - VINYL SE FLOOR - VCT CEILING - CT - RMSTRONG 15 16 PRELUDE XL GRID W/ FINE FISSURED SQURE LY IN 2X4 TILE - EVEN WITH TOP OF EXTERIOR WINDOWS (+/- 9'-0" FF) CCESSORY LIST THROOM CCESSORIES TOILET GR R - 48" TOILET GR R - 36" MIRROR - 24"X36" PPER TOWEL DISPENSER SOP DISPENSER SNITRY NPKIN DISPOSL TOILET PPER DISPENSER SIGNGE EXIT DOOR TCTILE SIGNGE REDING: EXIT D TOILET ROOM SIGN SIGNGE SHLL COMPLY WITH NSI/CO 117.1 MOUNT SIGNGE 60" FF TO CENTERLINE OF SIGN FIRE EXTINGUISHERS FIRE EXTINGUISHER TYPE "" (UL RTING 3-40:C) 5L MULTIPURPOSE DRY CHEMICL EQUL TO DGER MODEL #5M-6H SK1-181010 DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT ND OTHER PROPERTY RIGHTS IN THESE DRWINGS. THESE DRWINGS, PLNS & DESIGNS RE NOT TO E REPRODUCED, COPIED OR USED IN NY MNNER WITHOUT EXPRESSED WRITTEN PERMISSION ND CONSENT OF RCHITECTS ENGINEERS, INC. THESE PLNS SHLL NOT E DISTRIUTED TO NY PRTY WITHOUT SID WRITTEN PERMISSION & CONSENT. TITLE: FLOOR PLN NO. DTE REVISION DRWN Y: CS CHECKED Y: CS DTE: 11-05-18-1
GENERL NOTES 1. SWING & FORCED OPEN DOORS SHLL MEET THE REQUIREMENTS OF NFP LIFE SFETY CODE S FOUND IN THE FLORID FIRE PREVENTION CODE 6th EDITION CHPTER 7.2.1.4 ND THE FLORID UILDING CODE 6th EDITION (2017) 1008.1.2. 2. SELF CLOSING DEVICES SHLL E PROVIDED ON DOORS IN MENS OF EGRESS ND SHLL MEET THE REQUIREMENTS OF THE NFP LIFE SFETY CODE (LTEST EDITION) CHPTER 7.2.1.8 ND THE FLORID FIRE PREVENTION CODE 5th EDITION. 3. THIS UILDING WILL E NONSMOKING FCILITY. 4. LL WORK SHLL E IN COMPLINCE WITH THE UILDING CODES, RECOGNIZED INDUSTRY STNDRDS, CRFTSMNSHIP STNDRDS IN THE RE, ND LL MNUFCTURER'S RECOMMENDTIONS. 5. FLOOR FINISHES ON OTH SIDES OF DOOR SHLL E LEVEL FOR DISTNCE EQUL TO THE WIDTH OF THE WIDEST SINGLE DOOR (DOOR ON OTH SIDES). CRIG. SOMMERS, I RCHITECT - R0016480 6. GENERL CONTRCTOR SHLL PROVIDE FLORID PRODUCT PPROVL NOTICES FOR LL COMPONENTS ND CLDDING ON THE EXTERIOR OF THE UILDING. 7. FIELD VERIFY LL DIMENSIONS ND EXISTING CONDITIONS PRIOR TO CONSTRUCTION. REPORT NY ND LL DISCREPNCIES TO THE RCHITECT/ENGINEER. 8. CONTRCTOR SHLL PERMNENTLY IDENTIFY LL FIRE-RESISTNT-RTED WLLS (ND CORRESPONDING FIRE-RESISTNT RTINGS) INCLUDING FIRE RRIER WLLS, SMOKE RRIER WLLS, FIRE PRTITIONS, FIRE WLLS, ND SHFT ENCLOSURES EITHER Y INSTLLING SIGNS OR Y STENCILING IN CONCELED SPCES THE FOLLOWING: ( ) HOUR FIRE ND SMOKE RTED RRIER - PROTECT LL OPENINGS. IDENTIFICTION SHLL E SPCED NO MORE THN TWELVE (12) FEET ON CENTER WITH MINIMUM LETTER SIZE OF TWO (2) INCHES IN HEIGHT ON CONTRSTING CKGROUND 9. DO NOT SCLE DRFTING, REPORT ERRORS IN DIMENSIONING TO RCHITECT EFORE PROCEEDING WITH WORK. 10. DIMENSIONS NOTED S "CLER" RE FROM FCE OF GYPSUM WLLORD TO GYPSUM WLLORD. RCHITECTS ENGINEERS, INC. 370 15th ve S; Units & R&P Technologies 800 MYPORT ROD TLNTIC ECH, FLORID 32233 Florida Certificate of uth No: 00009393 Florida License No.: 26000952 REFLECTED CEILING PLN SCLE: 1/4"= 1'-0" LIGHTING SCHEDULE 2X4 LY IN FIXTURE 2X2 LY IN FIXTURE 1X4 SURFCE MOUNT FIXTURE EXIT / EMERGENCY COMO LIGHT EMERGENCY LIGHT NEW LIGHT SWITCH (3 = 3 WY) EXISTING FIXTURE TO REMIN EXISTING FIXTURE TO REMIN EXISTING FIXTURE TO REMOVE EXISTING LIGHT SWITCH HVC LEGEND SUPPLY IR - CUT IN REGISTER FOR THROOM (NOTE LY IN SUPPLY MY E USED) EXHUST FN EXISTING RETURN IR EXISTING SUPPLY IR LY IN SUPPLY IR LY IN RETURN IR SK2-181010 DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT ND OTHER PROPERTY RIGHTS IN THESE DRWINGS. THESE DRWINGS, PLNS & DESIGNS RE NOT TO E REPRODUCED, COPIED OR USED IN NY MNNER WITHOUT EXPRESSED WRITTEN PERMISSION ND CONSENT OF RCHITECTS ENGINEERS, INC. THESE PLNS SHLL NOT E DISTRIUTED TO NY PRTY WITHOUT SID WRITTEN PERMISSION & CONSENT. TITLE: REFLECTED CEILING PLN NO. DTE REVISION DRWN Y: CS CHECKED Y: CS DTE: 11-05-18-2
TOILET CCESSORY LEGEND SURFCE MTD. PPER TOWEL DISPENSER DOULE TOILET PPER HOLDER ORICK -6867 SURFCE MTD. SOP DISPENSER SNITRY NPKIN DISPOSL 18 x 42 MIRROR HNDICPPED GR R ORICK -5806X36-5806X42 NOTES 1. HNDICPPED CCESS MOUNTING DIMENSIONS RE VERY CRITICL ND HVE NO MINUS TOLERNCES. MOUNTING LOCTION OF TOILET CCESSORIES TO E IN CCORDNCE WITH.D.. TITLE III & FLORID UILDING CODE 5th EDITION (2014) - CCESSIILITY. 2. LL DIMENSIONS SHOWN RE FROM FCE OF FINISH. FINISH THICKNESS MUST E DDED TO NY ROUGH IN DIMENSIONS. CRIG. SOMMERS, I RCHITECT - R0016480 WHERE THE TOILET IS FOR INDIVIDUL USE ND CLER FLOOR SPCE COMPLYING WITH FC-CCESS 305.3 ( 30"x48" SPCE) IS PROVIDED WITHIN THE ROOM EYOND THE RC OF THE DOOR SWING, DOORS SHLL E PERMITTED TO SWING INTO THE CLER FLOOR SPCE OR CLERNCE REQUIRED FOR NY FIXTURE (FC-CCESS 603.2.3 EXCEPTION 2) WHERE THE SPCE ENETH N ELEMENT IS INCLUDED S PRT OF THE CLER FLOOR OR GROUND SPCE, THE SPCE SHLL COMPLY WITH FC-CCESSIILITY 306 FOR KNEE & TOE CLERNCE THE SPCE ENETH THE SINK COMPLIES WITH THIS REQUIREMENT ENLRGED TOILET ROOM PLN SCLE: 1/2"= 1'-0" ROOM 107 RCHITECTS ENGINEERS, INC. R&P Technologies 370 15th ve S; Units & 800 MYPORT ROD TLNTIC ECH, FLORID 32233 Florida Certificate of uth No: 00009393 Florida License No.: 26000952 POWER PLN SCLE: 1/4"= 1'-0" POWER LEGEND DUPLEX RECEPTCLE (GFI WHERE NOTED) EMPTY J-OX WITH CONDUIT ND PULL STRING TO OVE CEILING FOR FUTURE PHONE/DT Y OTHERS DISCONNECT / POWER FOR HVC EQUIPMENT EXISTING DUPLEX RECEPTCLE EXISTING QUD RECEPTCLE RELOCTED EXISTING ELECTRICL PNEL SK3-181010 DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT ND OTHER PROPERTY RIGHTS IN THESE DRWINGS. THESE DRWINGS, PLNS & DESIGNS RE NOT TO E REPRODUCED, COPIED OR USED IN NY MNNER WITHOUT EXPRESSED WRITTEN PERMISSION ND CONSENT OF RCHITECTS ENGINEERS, INC. THESE PLNS SHLL NOT E DISTRIUTED TO NY PRTY WITHOUT SID WRITTEN PERMISSION & CONSENT. TITLE: POWER PLN NO. DTE REVISION DRWN Y: CS CHECKED Y: CS DTE: 11-05-18-3
FOR REFERENCE ONLY; REFER TO FLORID CCESSIILITY CODE 6th EDITION (2017) FOR UILDING CONSTRUCTION DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT ND OTHER PROPERTY RIGHTS IN THESE DRWINGS. THESE DRWINGS, PLNS & DESIGNS RE NOT TO E REPRODUCED, COPIED OR USED IN NY MNNER WITHOUT EXPRESSED WRITTEN PERMISSION ND CONSENT OF RCHITECTS ENGINEERS, INC. THESE PLNS SHLL NOT E DISTRIUTED TO NY PRTY WITHOUT SID WRITTEN PERMISSION & CONSENT. DRWN Y: CS CHECKED Y: CS DTE: 11-05-18-4 TITLE: CCESSIILITY GUIDELINES NO. DTE REVISION R&P Technologies 800 MYPORT ROD TLNTIC ECH, FLORID 32233 RCHITECTS ENGINEERS, INC. 370 15th ve S; Units & Florida Certificate of uth No: 00009393 Florida License No.: 26000952 CRIG. SOMMERS, I RCHITECT - R0016480
MECHNICL NOTES 1. LL WORK SHLL E COORDINTED WITH LL TRDES INVOLVED. OFFSETS IN DUCTS, & TRNSITIONS ROUND OSTRUCTIONS SHLL E PROVIDED T NO DDITIONL COST. MINTIN MNUFCTURER'S RECOMMENDED CLERNCES. LOCTION OF DUCTWORK IS PPROXIMTE. PRIOR TO FRICTING DUCTWORK, CONTRCTOR SHLL VERIFY LL DIMENSIONS & CLERNCES ND REPORT NY DISCREPNCIES ETWEEN DRWINGS & CTUL FIELD CONDITIONS TO THE ENGINEER. PRIOR TO INSTLLING EQUIPMENT, CONTRCTOR SHLL ENSURE EQUIPMENT CLERNCES WILL E MINTINED. 2. FRICTE & INSTLL DUCTWORK IN CCORDNCE WITH SMCN DUCT MRK HU-1 /CU-1 TOTL FLOW INDOOR FN DT 0/ ESP (W.G.) FL MOTOR (HP) ED EW COOLING CPCITY MIENT TOTL (TU/HR) SPLIT SYSTEM COOLING UNIT SENSILE (TU/HR) SEER COMP. RL OUTDOOR FN FL MC INDOOR FN OUTDOOR FN ELECTRICL DT MOCP HETER (kw) MC MOCP VOLTS Hz PHSE 1150 120 0.5 2.6 0.5 77 64 95 32,719 25,636 14 14.1 1.2 23 25 2.88 18 30 208 60 1 1. UNITS PROVIDED SHLL MEET LL SCHEDULED VLUES REGRDLESS OF MODEL OR TYPE, UNLESS PPROVED Y THE ENGINEER. 2. PROVIDE ECH UNIT WITH THERMOSTT MOUNTED @ 48" FF. SIS OF DESIGN TRNE TEM4036S31/4TTR4 RNCH & FLEX DUCT SCHEDULE CFM - 6"Ø 165-250 CFM - 8"Ø 255-380 CFM - 10"Ø 385-470 CFM - 12"Ø 475-700 CFM - 14"Ø CFM - 16"Ø NOTE : RNCH RUNOUT SIZE REFLECTS SUPPLY DIFFUSER NECK SIZE UNLESS OTHERWISE NOTED. CREN M. DOHERTY, P.E. FL. P.E. #-55021 CONSTRUCTION STNDRDS, LTEST EDITION. 3. CONDENSTE DISPOSL SHLL E IN CCORDNCE WITH 2017 FMC INCLUDING LL LTEST REVISIONS. 4. CONDENSTE PIPING SHLL E TRPPED ND SIZED PER MNUFCTURER'S RECOMMENDTIONS. 5. INDOOR & OUTDOOR UNITS SHLL HVE SINGLE POINT OF CONNECTION. 6. PROVIDE CONICL TKE-OFFS FOR LL ROUND TPS INTO RECTNGULR DUCTWORK WITH VOLUME DMPERS T ECH TKE-OFF FOR CFM DJUSTMENT. 7. COORDINTE DIFFUSER OXES, SUPPLY, & RETURN GRILLES & OTHER MECHNICL DEVICES WITH LIGHT FIXTURES, SPRINKLER PIPING & PLUMING. 8. PROVIDE LOW MIENT CONTROLS S NECESSRY TO LLOW COOLING T TEMPERTURES DOWN TO 45 F. 9. HORSEPOWER RTINGS ON MOTORS RE SED ON SCHEDULED EQUIPMENT & DESIGN CONDITIONS. CTUL FIELD CONDITIONS OR SUSTITUTIONS FROM SCHEDULED EQUIPMENT MY REQUIRE DIFFERENT HORSEPOWER. IF LRGER MOTOR SIZES RE REQUIRED OR CHNGES OCCUR IN VOLTGES, COORDINTE ELECTRICL SERVICE TO ENSURE PROPER WIRE SIZES & DEVICES T NO DDITIONL COMPENSTION (DUE TO THESE CHNGES) SKED FOR OR MRK HU-2 /CU-2 TOTL FLOW INDOOR FN DT 0/ ESP (W.G.) FL MOTOR (HP) ED EW EXISTING SPLIT SYSTEM COOLING UNIT COOLING CPCITY MIENT TOTL (TU/HR) SENSILE (TU/HR) EER COMP. RL OUTDOOR FN FL IR DISTRIUTION DEVICE SCHEDULE MRK DESCRIPTION MOUNTING FCE SIZE SIS OF DESIGN NOTES MC INDOOR FN OUTDOOR FN ELECTRICL DT MOCP HETER (kw) MC MOCP VOLTS Hz PHSE 800 80 -- 1.3 0.25 80 67 95 24,000 -- -- -- -- 23 25 5 -- -- 208 60 1 1. UNITS PROVIDED SHLL MEET LL SCHEDULED VLUES REGRDLESS OF MODEL OR TYPE, UNLESS PPROVED Y THE ENGINEER. 2. PROVIDE ECH UNIT WITH THERMOSTT MOUNTED @ 48" FF. SIS OF DESIGN TRNE TEM3024S21S RCHITECTS ENGINEERS, INC. 370 15th ve S; Units & Florida Certificate of uth No: 00009393 Florida License No.: 26000952 REQUESTED Y NOTHER CONTRCTOR OR TRDE. 10.REFRIGERNT LINES FROM CU's TO HU's SHLL E SIZED PER 4-WY SUPPLY LY-IN / SURFCE 24"X 24" / 12"X 12" TITUS TMS 1,2 MNUFCTURER'S RECOMMENDTIONS. RETURN WLL / DOOR SEE DRWING TITUS 355FL 1,2 11. LL FN MOTORS SHLL HVE THERML OVERLOD & CURRENT PROTECTION. 12.PROVIDE SMOKE DETECTORS IN RETURN DUCT FOR LL HU's THT DELIVER 0 CFM OF SUPPLY IR OR GRETER FOR UNIT SHUTDOWN. CONTRCTOR SHLL PROVIDE UDILE & VISUL LRM IN CONSTNTLY OCCUPIED LOCTION. LRM SHLL E LELED "DUCT TROULE". 13.PROVIDE HU's WITH PROGRMMLE THERMOSTTS. 14.PROVIDE UNITS WITH 1" DISPOSLE FILTER & FILTER HOUSING, TIME DELY RELY & LOCKOUT RELY. 15.PROVIDE UNITS WITH 5 YER WRRNTY FOR COMPRESSORS & ONE YER ON OTHER PRTS. 16. LL DUCTWORK SHLL E CONSTRUCTED WITH METL OR DUCTORD PER LTEST SMCN STNDRDS, & SHLL HVE MINIMUM R VLUE OF 6. 17. LL WORK SHLL E PERFORMED IN CCORDNCE WITH THE 2017 FLORID MECHNICL CODE (INCLUDING LL LTEST REVISIONS), NFP 90, SHRE 62-2010, ND SHRE 90.1. 1. LOUVER FCE. 2. WITH OPTIONL DMPER. MRK SERVICE TOTL IR E.S.P. (W.G) EXHUST FN SCHEDULE UNIT TYPE DRIVE POWER (W) MPS VOLTS/PH/HZ MNUFCTURER MODEL NUMER NOTES EF-1 TOILET ROOM 70 0.10 CEILING DIRECT 96 0.8 120/1/60 NUTONE 671R 1,2 NOTE: 1. INTERLOCK WITH LIGHT SWITCH. 2. PROVIDE CKDRFT DMPER. LOUVER SCHEDULE OUTDOOR IR VENTILTION CLCULTION SHRE 62.1 4 Vbz = (Rp)(Pz) + (Ra)(z) R&P TECHNOLOGIES 800 MYPORT ROD TLNTIC ECH, FLORID 32233 CU-1 CU-2 (EX) L-1 100 700 50 HU-2 (EX) ROOM 102 150 ROOM 107 600 100 MRK MECHNICL PLN SCLE: 1/4"= 1'-0" DESCRIPTION TOTL IR MOUNTING FCE SIZE MTERIL SIS OF DESIGN NOTES L-1 OUTDOOR IR INTKE WLL MOUNTED 13" x 12" LUMINUM GREENHECK EVH-501 1,2 1. COORDINTE FINISH WITH RCHITECT. 2. PROVIDE INSECT SCREEN. ROOM 103 250 ROOM 104 100 95 450 1100 HU-1 ROOM 106 ROOM 105 SPCE PEOPLE OUTDOOR IR RTE (RP) CEILING CEILING INTKE ZONE POPULTION (Pz) RE OUTDOOR IR RTE (Ra) CEILING FN WITH CKDRFT DMPER ZONE FLOOR RE (z) (TOILET) 0 0 0 56 EXHUST (Ea) 70 CFM x TOILET EXISTING ROOF CP IRD SCREEN RETHING ZONE (Vbz) ROOM 102 (OFFICE) 5 1 0.06 172 N/ 15 ROOM 103 (OFFICE) 5 3 0.06 611 N/ 52 ROOM 104 (OFFICE) 5 1 0.06 96 N/ 11 ROOM 105 (OFFICE) 5 2 0.06 274 N/ 26 ROOM 106 (HU) 0 0 0.06 12 N/ 1 ROOM 107 (REK) 7.5 2 0.06 69 N/ 19 TOTL O/ REQUIRED = 124 CFM O/ PROVIDED THROUGH HU-1 = CFM TOILET EXHUST DETIL NOT TO SCLE TOTL = 70 124 0 EXISTING DUCT TO ROOF CP DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT ND OTHER PROPERTY RIGHTS IN THESE DRWINGS. THESE DRWINGS, PLNS & DESIGNS RE NOT TO E REPRODUCED, COPIED OR USED IN NY MNNER WITHOUT EXPRESSED WRITTEN PERMISSION ND CONSENT OF RCHITECTS ENGINEERS, INC. THESE PLNS SHLL NOT E DISTRIUTED TO NY PRTY WITHOUT SID WRITTEN PERMISSION & CONSENT. MECHNICL PLN, NOTES, SCHEDULES, & DETILS TITLE: DTE: REVISION DTE NO. DRWN Y: CHECKED Y: 1 11-07-18 PLN CHNGES MG CMD 11-13-18 M-1
Issue Date 10/10/18