ventilation solutions for schools, academies, colleges and universities

Similar documents
ventilation solutions

7 YEAR. The DRIMASTEReco Range DRI-ECO-HC NUAIRE S PIV: HALL CONTROL

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

SMOKE CONTROL - NEW DIRECTIONS

VENTILATION PRODUCTS & CONTROLS FOR COMMERCIAL KITCHENS

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV)

OPUSXBOX - SMALL COMMERCIAL HEAT RECOVERY SYSTEM LOW DEPTH, HEAT RECOVERY UNIT WITH MULTIPLE SPIGOTS AND ECOSMART CONTROLS.

The Range HIGHEST INDOOR AIR QUALITY IN NEW HOMES

more than just a fan supplier more than just a fan supplier Axair Fans UK Limited

LANDLORDS & LETTINGS VENTILATION SOLUTIONS

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

0.4 m 3 /s. Plastic and Steel cased fan Units. Round Fans. Latest EC Fan Technology. Compact and Powerful. Easy to install

Building Regulations 2010: What it means to you.

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

AP-EH500-L/RQA9837. Installation Guide

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

WORLDWIDE VENTILATION SOLUTIONS

MRXBOX95AB-WH2 (with automatic summer bypass)

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications.

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

The new Xcell EC High Efficiency Range Fresh air pure and simple

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

Sentinel Demand Energy Recovery Ventilation

Gemini EC. Engineered with Excellence, Specified with Confidence All-in-One Renewable Energy Climate Control

CI/SfB (57.7) 1st edition

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

The new generation of MVHR units - ComfoAir Q. Always the best climate for PERFORMANCE

MEV-DC. Continuous Mechanical Extract Ventilation Units Installation and Maintenance. Figure 3. Fixing screw hole.

Wiring the fan correctly...

ENERGY RECOVERY VENTILATION (ERV)

Ventilation. Product Information

Lo-Carbon Sentinel Kinetic Horizontal

Introducing the RetroVent

MEV Ecosmart. Installation and Maintenance. Continuous Mechanical Extract Ventilation Units. 1.0 Introduction

INDOOR USE ONLY. Installation and Maintenance XTRACTOR. (ESX) 1 and 3 phase, Direct Drive, Fans for indoor use

Small Room Heat Recovery Ventilation

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

Classvent Quiet. Acoustic Testing Laboratory College of Science & Technology. Engineering Solutions

Installation and Maintenance

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Caice Attenuator Selector - Specifier Edition

(57.7) X. March 2006 PRODUCTS. ... the complete solution

FUME EXTRACT STRATEGY STATEMENT

AERECO DEMAND CONTROLLED VENTILATION COMBINING INDOOR AIR QUALITY AND ENERGY SAVINGS

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

PFS Single stage axial fan The axial fan for modern boiler plants

The POWERBOOST. Range GROUP. Clean Water Booster Sets

CI/SfB (57.7) 3rd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range.

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

Stainless Steel Sanitary Ware

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance

Domestic & Commercial Fans

Wiring the fan correctly...

Unit heater with accessories

An introduction to Part L Insulating pipes and ducts

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover

Systemair product news - Fans NEWS

Installation and Maintenance

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR)

The UK s Leading Ventilation Company. Lo-Carbon Revive. 2nd Edition.

CI/SfB (57.7) 2nd edition

Heating and Comfort Policy. Reviewed April 2014

CI/SfB (57.7) 2nd edition. Lo-Carbon Quadra

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

Ventilation Product range ADVANCE ECO 4 ECO 2

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Polypipe Ventilation Specifiers Guide

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

ECOSMART XTRACTOR. (ESX-X/R/B) 1 phase, Direct Drive For External, Roof Mounted and Internal use Installation and Maintenance.

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

Installation and Maintenance

RESIDENTIAL VENTILATION DUCTING SOLUTIONS

ECOSMART TWINFANS. (EST-X/R/B) 1 phase, Direct Drive, Run & Standby For External, Roof Mounted and Internal use Installation and Maintenance

Air Handling Units. direct drive - belt drive - custom built

Energy Efficiency Standards

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

Fred Castle Way Rougham Industrial Estate Bury St Edmunds Suffolk IP30 9ND United Kingdom

Installation and Maintenance

Air Handling Units. Real HVACR people who understand your needs.

X-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications.

OPUS PLUS TWINFANS COMPACT & POWERFUL, IDEAL FOR LARGER ROOM APPLICATIONS WHILST MAINTAINING LOW NOISE LEVELS.

HYBRID PLUS2 AIRCOOL VENTILATORS

MRXBOX95-WH1 MECHANICAL VENTILATION WITH HEAT RECOVERY

PRODUCT RANGE POOL AIR HANDLING UNITS. Swimming pool and spa environmental control, heating, cooling and dehumidification

230V & SELV INSTALLATION GUIDE FOR ENGINEER / INSTALLER IPX4 IPX5

Emergency Extract Ventilation

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Installation and Maintenance

NATURAL VENTILATION CONTROL SYSTEMS

Apartment Ventilation. "Microbox" Continuous Mechanical Extract Units

experts in damp, mould, condensation control + organic heating & cooling xchangeair.com.au

Transcription:

for schools, academies, colleges and universities

Creating environments that inspire learning We eliminate the risk and high cost of ventilation by designing and manufacturing innovative products for homes and buildings which optimise air quality and energy consumption for your application and which work right first time and every time, anywhere in the world, on the day you require them at the lowest installed cost. Nuaire has become one of the largest, most successful and respected fan manufacturers in the world and its products are now available in over 40 countries. Modern ventilation is all about people and providing a good level of indoor air quality whilst ensuring an effective building performance. With issues such as air quality, energy efficiency and noise pollution becoming increasingly important, delivering a ventilation system which creates a fresh, healthy and comfortable environment is paramount in the choice of an optimum energy saving ventilation solution. With over 5 decades of experience, Nuaire is the market leader in the design and manufacture of energy efficient domestic, commercial and renewable ventilation solutions. Nuaire fans are used in all types of commercial and residential buildings, infrastructure projects and numerous applications by original equipment manufacturers in the UK and around the world. 2 www.nuairegroup.com www.nuairegroup.com 3

Application & Product selection guide To help you select the appropriate ventilation solution for your application, simply refer to one of the application options alongside. Squif Twin Ecosmart Xtractor Squif Ecosmart Airmover Ecosmart Boxer XS Roof XS Ecosmart Squrbo Opus 40 Opus 60 Opus 95 ES Opus dc Opus plus Ecosmart Twins Constant Pressure Axus Terminator EZPlate Mark 10 SqurboXbox mrxbox 90 (s) mrxbox 90 (m) mrxbox 90 (l) mrxbox 70 SquirboXbox twin fan AirepodXbox OpusXbox Ecosmart MEV MEV-SVS Ecostrat Page Number 11 10 10 16 12 12 14 12 16 16 17 16 16 12 14 12 16 12 10 10 10 10 10 10 12 14 16 14 14 12 For further technical details, please visit www.nuairegroup.com Sports Halls Schoolrooms/Classrooms Changing Rooms Swimming Pools Drama Studios Offices (Small and Large) Toilets (multiples) Toilets (individual) Boiler Rooms Workshops Science Labs Libraries IT Suites Food Technology Suite Canteen Kitchen Residential Block Study Area Stairwells Drama Theatre/Auditorium Assembly Hall 4 www.nuairegroup.com www.nuairegroup.com 5

In Partnership with you... Nuaire has a reputation in the industry for working closely with our customers to offer the right fan solution to meet their specific needs. As a result we have created a new team, specifically to support the ever increasing number of large and special projects that require variations to our standard product range. Our Applications Engineering team provides a dedicated resource to our customers to ensure the best possible solution for a project. Nuaire works in partnership with our customers to deliver client focused solutions. By working closely with you we are able to deliver a fast response to the many specification changes that a complex project demands, ensuring that each one runs as smoothly as possible. Innovation... Ventilation... Education With issues concerning indoor air quality within schools becoming increasingly important, it is necessary to create fresh, healthy and comfortable learning environments for both teachers and pupils. In keeping with a project s aim to offer affordable, sustainable facilities, Nuaire s specialist in-house Application Engineers design the best solutions for the building, combining conventional ventilation solutions but also creating bespoke specialist products to provide the most energy efficient solution possible. In line with our customer requirements, the heat recovery range has been expanded to meet desired performance criteria. Working closely with contractors, Nuaire has developed a bespoke vertical room heat recovery unit with CO 2 control and electric space heating. These new units fit under working space, a work bench for example, and draw and discharge air through the wall. They have been designed to meet stringent noise requirements and power consumption criteria and were designed for ICT classrooms and Science rooms. Due to the sporadic occupancy of areas such as classrooms, Ecosmart can be provided which automatically adjust the systems to allow varying fan speeds, matching the output of the systems to the demand, to minimise energy usage. Controls can be linked to business management systems providing on demand ventilation, minimising carbon emissions and also prolonging the life of the equipment. Specific are modified to suit the on site conditions, with Nuaire working closely with the customer and the contractor to interface the equipment. Nuaire - in a class of their own Environments that inspire learning 6 www.nuairegroup.com www.nuairegroup.com 7

Inspiring Schools Schools are there to give children the knowledge and skills they need to become active members of society. Many children are rightly worried about climate change, global poverty and the impact of our lifestyles. Schools can demonstrate ways of living that are models of good practice for children and their communities. They can build sustainable development into the learning experience of every child to encourage innovation and improvement. Alan Johnson, Secretary for Education and Skills - September 2006 City Academy - Bristol Ventilation: Ecosmart Squrbo, Terminator, Ecosmart twin fan Penderyn Community School Ventilation: Axus, Bifurcated axial, Squif, Ecosmart Beechwood School - Slough Ventilation: SqurboXbox twin fan, Squif, Ecosmart Xtractor Bristol Brunel Academy Ventilation: SqurboXbox, Ecosmart twin fan, Squif, Squrbo, Opus Walthamstow Academy Ventilation: Ecosmart Xtractor, XS, Opus 30, Opus 60, Squrbo, Squif Dwr-y-Felin Upper School Ventilation: Ecosmart twin fan, Ecosmart Boxer, Squrbo, Axus 8 www.nuairegroup.com www.nuairegroup.com 9

Classrooms and dining area High Performance Kitchen Supply and Extract Mechanical Extract and Heat Recovery Energy efficient, high performance extract with heat recovery (up to 2.5m 3 /s) inbuilt Ecosmart plug and go Low profile is ideal for ceiling void installation (external option available) Easy maintenance with side access panels Wide range of vertical, horizontal or twin fan options to suit most applications Optional weather cowls for horizontal and stacked configuration Squif Inline with motor out of airstream (up to 6.5m 3 /s) Safety first with smoke extract as standard (400ºC for 2 hours) Ideal for commercial kitchens as units have high temperature as standard (90ºC) Cost effective system with low maintenance requirements Flexible solution with over 13 models to choose from Easy to install & commission reduces time on site NEW Squif Twin Inline with motor out of airstream (up to 6.2m 3 /s) Ideal for commercial kitchens as built-in duty and stand by fan guarantees 24/7 in the event of fan failure High temperature as standard, can run continuously at 90ºC Flexible solution which can be mounted internally, externally, vertically or horizontally Out of airstream motor allows quick and easy maintenance For simple installation and commissioning include Ecosmart energy efficient Ecosmart boxer High performance, packaged supply AHU (up to 4.5m 3 /s) Ecosmart energy efficient plug & go High performance but very quiet for noise sensitive areas Reduce time on site with packaged solution Electric heater or LPHW options External version available Axus Duct mounted axial extract fans (up to 95m 3 /s) Widest range of standard axials available ensure maximum efficiency Added strength and durability as units are manufactured using heavy gauge galvanised steel Advanced production methods give consistent superior performance at low costs Air performance to BS848 and ISO5801 with acoustic performance to AMCA300 Comprehensive range of ancillaries available Bifurcated Axial Duct mounted axial, motor out of airstream (up to 23m 3 /s) Widest range of standard bifurcated axials available Standard range is suitable for temperatures up to 90ºC High temperature options available up to 230ºC For ease of application a stock range is available. Please contact Nuaire. Choice of matched ancillaries OpusXbox Energy efficient, low profile extract with heat recovery (up to 80l/s) Easy to install with one fix bracket Simple to commission with inbuilt Ecosmart plug and go Ideal for restricted space due to low profile (185mm) Lift off top panels make for easy maintenance Installation features: SqurboXbox inline version NEW mrxbox90 High efficiency extract with heat recovery (up to 300m 3 /hr) Market s most efficient extract unit with 90% efficiency Simple to commission with choice of Wireless option for the ultimate control Ideal for cupboard or wall mounting Lift off front panel makes for easy maintenance Installation features: Squif mrxbox70 Multipoint extract with heat recovery (up to 67l/s) Ideal for cupboard or wall mounting as it is only 340mm deep Automatic suitable for all applications Easy to commission with integral balancing dampers XS range Wall, window, ceiling and roof extract fans (up to 530 l/s) Ideal for noise sensitive areas as provides high performance and low noise Flexible solutions in 6,9, & 12 models reversible for extract or supply Save costs and control up to 5 fans with one speed control Inbuilt sensors help reduce wiring costs Installation features: Mark 10 Ecosmart Xtractor High efficiency centrifugal fan (up to 5.9m 3 /s) Flexible solution, wide range of 27 fans to suit most applications Quiet fan ideal for noise sensitive areas Powerful extract fan for multi-room system Easy to install and commission with Ecosmart plug & go Requires very low maintenance General Extract Ecosmart Squrbo Energy efficient make up air supply & extract units (up to 0.5m 3 /s) Exceptionally quiet fans ideal for above ceiling applications Ecosmart plug & go are quick to install and commission Quick & easy commission with easily adjustable fan and heater duty Wide range of complimentary sensors and suitable for most applications Reduce installation time with one box containing filter, fan, heater & Installation features: SqurboXbox roof mounted Ecosmart Airmover High performance backward curved centrif (up to 10.6m 3 /s) Ecosmart energy efficient plug & go Exceptionally quiet with double skinned panels Low maintenance requirements help reduce costs Flexible solution with over 12 models to choose from Mark 10 Vertical discharge roof extract fan (up to 8.2m 3 /s) For simple installation & commissioning include Ecosmart energy efficient plug & go Discreet design with low profile Low maintenance requirements help reduce costs Flexible solution with over 22 models to choose from XS Roof Roof extract fan up to 530l/s Ideal for noise sensitive areas as provides high performance and low noise Flexible solutions in 6,9, & 12 models reversible for extract or supply Save costs and control up to 5 fans with one speed control Inbuilt sensors help reduce wiring costs 10 www.nuairegroup.com www.nuairegroup.com 11

Multiple toilets, changing rooms, sports hall and boiler room High Performance Supply and Extract Energy efficient, high performance extract with heat recovery (up to 2.5m 3 /s) inbuilt Ecosmart plug and go Low profile is ideal for ceiling void installation (external option available) Easy maintenance with side access panels Wide range of vertical, horizontal or twin fan options to suit most applications Optional weather cowls for horizontal and stacked configuration Ecosmart boxer High performance, packaged supply AHU (up to 4.5m 3 /s) Ecosmart energy efficient plug & go High performance but very quiet for noise sensitive areas Reduce time on site with packaged solution Electric heater or LPHW options External version available XS range Wall, window, ceiling and roof extract fans (up to 530 l/s) Ideal for noise sensitive areas as provides high performance and low noise Flexible solutions in 6,9, & 12 models reversible for extract or supply Save costs and control up to 5 fans with one speed control Inbuilt sensors help reduce wiring costs Installation features: Ecosmart Boxer Installation features: Axus General Extract Axus Duct mounted axial extract fans (up to 95m 3 /s) Widest range of standard axials available ensure maximum efficiency Added strength and durability as units are manufactured using heavy gauge galvanised steel Advanced production methods give consistent superior performance at low costs Air performance to BS848 and ISO5801 with acoustic performance to AMCA300 Comprehensive range of ancillaries available Ecosmart Boxer High performance, packaged supply AHU (up to 4.5m 3 /s) Ecosmart energy efficient plug & go High performance but very quiet for noise sensitive areas Reduce time on site with packaged solution Electric heater or LPHW options External version available Installation features: EZ Plate Terminator Horizontal discharge roof extract fan Flexible solution with choice of axial, centrifugal or mixed flow impellers On site flexibility allows unit to be mounted vertically or horizontally Low profile weather cowl provides unobtrusive roof top option Reduce energy costs by selecting Ecosmart efficient Plant Room Extraction EZ Plate Wall mounted axial plate fans (up to 9.3m 3 /s) Adaptable solution can be fixed in any altitude on site For safety, motors are fitted with heat seeker thermal overload protection Flexible range controllers and ancillaries available Fans are rated IP44 and IP54 Ecosmart Airmover High performance backward curved centrif (up to 10.6m 3 /s) Ecosmart energy efficient plug & go Exceptionally quiet with double skinned panels Low maintenance requirements help reduce costs Flexible solution with over 12 models to choose from XS Roof Roof extract fan up to 530l/s Ideal for noise sensitive areas as provides high performance and low noise Flexible solutions in 6,9, & 12 models reversible for extract or supply Save costs and control up to 5 fans with one speed control Inbuilt sensors help reduce wiring costs Ecosmart Twins Energy efficient internal & external twin fan (up to 5.8m 3 /s) Quietest twin fans available so ideal for noise sensitive areas Demand ventilation means maximum savings achieved Trickle function keeps environment fresh while still saving energy Easy to install & commission Ecosmart plug & go reduce overall installation costs Opus DC Single or twin duct fans (up to 115l/s) Quiet fans ideal for above ceiling applications Simple to install with self locating bracket Added safety of auto changeover and duty share on twin model Hard wearing and robust, flame retardant casing Choice of on board or remote For simple installation and commissioning include the Ecosmart energy efficient plug and go Destratification Ecostrat High performance, energy efficient destratification unit Exceptional performance achieving destratification to within 1 C Energy efficient, minimising energy usage by redistributing high level warm air Cost effective achieving up to 20% saving in fabric related heat loss Easy installation due to simple mounting arrangement and no requirement for ductwork Easy maintenance due to low level mounting Installation features: SqurboXbox with twin fan extract Multiple Toilet Extract Energy efficient, high performance extract with heat recovery (up to 2.5m 3 /s) inbuilt Ecosmart plug and go Low profile is ideal for ceiling void installation (external option available) Easy maintenance with side access panels Wide range of vertical, horizontal or twin fan options to suit most applications Optional weather cowls for horizontal and stacked configuration Ecosmart Squrbo Energy efficient make up air supply & extract units (up to 0.5m 3 /s) Exceptionally quiet fans ideal for above ceiling applications Ecosmart plug & go are quick to install and commission Quick & easy commission with easily adjustable fan and heater duty Wide range of complimentary sensors and suitable for most applications Reduce installation time with one box containing filter, fan, heater & Constant Pressure Quiet Scroll Twin Fan Energy efficient, high performance central extract (up to 2.65m 3 /s) Easy to install & commission Ecosmart plug & go reduce overall installation costs Saves costs by only ventilating when required, but trickle mode keeps environment continually fresh Extremely quiet for use in multi occupied areas System reduces energy costs by up to 70% Ease of control with inbuilt auto change over and speed control NEW Constant pressure volume damper Energy efficient, variable volume damper for use with twin fan Maintain correct ventilation levels with energy efficient dampers Flexible design solution with optional trickle & boost settings Easily adjustable make commissioning simple Quick to install & maintain helps reduce overall system costs 12 www.nuairegroup.com www.nuairegroup.com 13

Offices and residential areas Installation features: Ecosmart MEV Multi-room Ventilation Mechanical Extract for Offices and Communal Areas XS range Wall, window, ceiling and roof extract fans (up to 530 l/s) Ideal for noise sensitive areas as provides high performance and low noise Flexible solutions in 6, 9, & 12 models reversible for extract or supply Save costs and control up to 5 fans with one speed control Inbuilt sensors help reduce wiring costs NEW Ecosmart MEV Energy efficient multipoint continuous extract (up to 110l/s) Very quick to install with energy efficient plug & go Ecosmart Shallow depth makes it ideal for restricted spaces Ultra quiet with typical dba of 30 Simple commissioning with dial a duty Complies with new Building regulations NEW MEV SVS Multipoint continuous extract for noise sensitive environments (up to 110l/s) Features as Ecosmart MEV Designed specifically for noise sensitive or poor quality air applications, such as city centres or brown field sites) contact Nuaire for details. Acoustic airbricks available Constant Pressure Quiet Scroll Twin Fan Energy efficient, high performance central extract (up to 2.65m 3 /s) Easy to install & commission Ecosmart plug & go reduce overall installation costs Saves costs by only ventilating when required, but trickle mode keeps environment continually fresh Extremely quiet for use in multi occupied areas System reduces energy costs by up to 70% Ease of control with inbuilt auto change over and speed control NEW Constant pressure volume damper Energy efficient, variable volume damper for use with twin fan Maintain correct ventilation levels with energy efficient dampers Flexible design solution with optional trickle & boost settings Easily adjustable make commissioning simple Quick to install & maintain helps reduce overall system costs Ecosmart boxer High performance, packaged supply AHU (up to 4.5m 3 /s) Ecosmart energy efficient plug & go High performance but very quiet for noise sensitive areas Reduce time on site with packaged solution Electric heater or LPHW options External version available Terminator Horizontal discharge roof extract fan Flexible solution with choice of axial, centrifugal or mixed flow impellers On site flexibility allows unit to be mounted vertically or horizontally Low profile weather cowl provides unobtrusive roof top option Reduce energy costs by selecting Ecosmart efficient Installation features: XS Roof Ecosmart Squrbo Energy efficient make up air supply & extract units (up to 0.5m 3 /s) Exceptionally quiet fans ideal for above ceiling applications Ecosmart plug & go are quick to install and commission Quick & easy commission with easily adjustable fan and heater duty Wide range of complimentary sensors and suitable for most applications Reduce installation time with one box containing filter, fan, heater & Installation features: XS Window Energy efficient, high performance extract with heat recovery (up to 2.5m 3 /s) inbuilt Ecosmart plug and go Low profile is ideal for ceiling void installation (external option available) Easy maintenance with side access panels Wide range of vertical, horizontal or twin fan options to suit most applications Optional weather cowls for horizontal and stacked configuration Mechanical Extract with Heat Recovery Ecosmart Xtractor High efficiency centrifugal fan (up to 5.9m 3 /s) Flexible solution, wide range of 27 fans to suit most applications Quiet fan ideal for noise sensitive areas Powerful extract fan for multi-room system Easy to install and commission with Ecosmart plug & go Requires very low maintenance Installation features: XS Wall OpusXbox Energy efficient, low profile extract with heat recovery (up to 80l/s) Easy to install with one fix bracket Simple to commission with inbuilt Ecosmart plug and go Ideal for restricted space due to low profile (185mm) Lift off top panels make for easy maintenance mrxbox70 Multipoint extract with heat recovery (up to 67l/s) Ideal for cupboard or wall mounting as it is only 340mm deep Automatic suitable for all applications Easy to commission with integral balancing dampers NEW mrxbox90 High efficiency extract with heat recovery (up to 300m 3 /hr) Market s most efficient extract unit with 90% efficiency Simple to commission with choice of Wireless option for the ultimate control Ideal for cupboard or wall mounting Lift off front panel makes for easy maintenance NEW airepodxbox Supply & extract heat recovery plus warm air heating Extremely efficient system helps lower utility costs Warm air and fresh environment all year round Flexible mounting configuration ideally suited for ceiling 14 www.nuairegroup.com www.nuairegroup.com 15

IT Suite, Assembly area and Library Ventilation for noise sensitive areas Energy efficient, high performance extract with heat recovery (up to 2.5m 3 /s) inbuilt Ecosmart plug and go Low profile is ideal for ceiling void installation (external option available) Easy maintenance with side access panels Wide range of vertical, horizontal or twin fan options to suit most applications Optional weather cowls for horizontal and stacked configuration Installation features: OpusXbox Mechanical Extract and Heat Recovery Energy efficient, high performance extract with heat recovery (up to 2.5m 3 /s) inbuilt Ecosmart plug and go Low profile is ideal for ceiling void installation (external option available) Easy maintenance with side access panels Wide range of vertical, horizontal or twin fan options to suit most applications Optional weather cowls for horizontal and stacked configuration OpusXbox Energy efficient, low profile extract with heat recovery (up to 80l/s) Easy to install with one fix bracket Simple to commission with inbuilt Ecosmart plug and go Ideal for restricted space due to low profile (185mm) Lift off top panels make for easy maintenance Ecosmart Xtractor High efficiency centrifugal fan (up to 5.9m 3 /s) Flexible solution, wide range of 27 fans to suit most applications Quiet fan ideal for noise sensitive areas Powerful extract fan for multi-room system Easy to install and commission with Ecosmart plug & go Requires very low maintenance Opus DC Single or twin duct fans (up to 115l/s) Quiet fans ideal for above ceiling applications Simple to install with self locating bracket Added safety of auto changeover and duty share on twin model Hard wearing and robust, flame retardant casing Choice of on board or remote For simple installation and commissioning include the Ecosmart energy efficient plug and go Installation features: Opus DC Installation features: Terminator Individual Toilet Extract Opus Surface, semi-recessed, window & duct mounted (up to 95l/s) Exceptionally quiet Easy to operate range of Extra safe with flame retardant construction Simple to install reduces time on site Low maintenance filters are quick to change Mechanical Extract for large open areas Ecosmart Airmover High performance backward curved centrif (up to 10.6m 3 /s) Ecosmart energy efficient plug & go Exceptionally quiet with double skinned panels Low maintenance requirements help reduce costs Flexible solution with over 12 models to choose from Terminator Horizontal discharge roof extract fan Flexible solution with choice of axial, centrifugal or mixed flow impellers On site flexibility allows unit to be mounted vertically or horizontally Low profile weather cowl provides unobtrusive roof top option Reduce energy costs by selecting Ecosmart efficient Mark 10 Vertical discharge roof extract fan (up to 8.2m 3 /s) For simple installation & commissioning include Ecosmart energy efficient plug & go Discreet design with low profile Low maintenance requirements help reduce costs Flexible solution with over 22 models to choose from AHU Extract Ecosmart boxer High performance, packaged supply AHU (up to 4.5m 3 /s) Ecosmart energy efficient plug & go High performance but very quiet for noise sensitive areas Reduce time on site with packaged solution Electric heater or LPHW options External version available Ecosmart Squrbo Energy efficient make up air supply & extract units (up to 0.5m 3 /s) Exceptionally quiet fans ideal for above ceiling applications Ecosmart plug & go are quick to install and commission Quick & easy commission with easily adjustable fan and heater duty Wide range of complimentary sensors and suitable for most applications Reduce installation time with one box containing filter, fan, heater & XS range Wall, window, ceiling and roof extract fans (up to 530 l/s) Ideal for noise sensitive areas as provides high performance and low noise Flexible solutions in 6,9, & 12 models reversible for extract or supply Save costs and control up to 5 fans with one speed control Inbuilt sensors help reduce wiring costs NEW airepodxbox Supply & extract heat recovery plus warm air heating Extremely efficient system helps lower utility costs Warm air and fresh environment all year round Flexible mounting configuration ideally suited for ceiling 16 www.nuairegroup.com www.nuairegroup.com 17

Air Quality Our awareness of the spaces in which we live and work has never been more evident. But what about Britain s schools? The design of learning environments can have a significant impact on its users: the attainment and behaviour of the pupils, staff can feel more valued and motivated and people who live locally are more likely to use the facilities available to them. Compared to most other types of building, schools are extreme environments. They have high and sporadic occupancy levels, often boisterous use of circulation space and house many competing activities and functions within them. There are teachers, parents, pupils, classrooms, canteens and timetables - a great mix and more varied than most buildings. Part F of the Building Regulations applies to schools. Table 2.3 details specific approaches for a range of building types: Ventilation provisions in schools can be made in accordance with the guidance in DfES Building Bulletin 101. Ventilation of School Buildings and in the Education (School Premises) regulations. BB101 exists as a complete design guide to ventilation in schools, covering design rules for natural and mechanical ventilation systems and the concepts involved. Building Bulletin 101 can be used as a guide to the ventilation required in other education buildings such as further education establishments, also for children s centres and other early years settings, including day nurseries, playgroups etc. The School Premises Regulations (SPR) currently have the following requirements: 1 All occupied areas in school building shall have controllable ventilation at a minimum of 3 litres of fresh air per second for each of the maximum number of persons the area will accommodate. 2 All teaching accommodation, medical examination or treatment rooms, sick rooms, isolation rooms, sleeping and living accommodation shall also be capable of being ventilated at a minimum rate of 8 litres of fresh air per second for each of the usual number of people in those areas when such areas are occupied. 3 All washrooms shall also be capable of being ventilated at a rate of at least six air changes an hour. 4 Adequate measure shall be taken to prevent condensation in, and remove noxious fumes from, every kitchen and other room in which there may be steam or fumes. Such limits are intended to deal with the worst case conditions. Just as approved document F 2006 has introduced the concept of performance based ventilation for the control of important pollutants, BB101 makes a specific recommendation for the control of carbon Dioxide (CO 2 ), that has been proven by recent research to affect concentration and performance levels of pupils. Performance Standard Ventilation should be provided to limit the concentration of carbon dioxide in all teaching and learning spaces. When measured at seated head height, during the continuous period between the start and finish of teaching on any day, the average concentration of carbon dioxide should not exceed 1500 parts per million (ppm). Ventilation for actual ventilation for natural and mechanical systems is a minimum daily average supply rate of 5 l/s per person and a capability of 8 l/s per person during periods of occupation. These ventilation levels refer to general classrooms and similar areas. Where the educational process involves the production of fumes, vapours etc, normal risk assessment procedures should be adopted to determine ventilation needs. Energy Efficiency - including heating and cooling New school building must comply with the various requirements of Approved Document L2A (conservation of fuel and power, new buildings and other dwellings) 2006 edition. Specifically with request to ventilation, limits on specific fan power exist for several categories of ventilation. ADL 2A refers to BB101 specifically in terms of overheating in the summer. Standard ventilation levels for the provision of fresh air and control of pollutant levels will generally be inadequate to control overheating due to solar and thermal gains. The performance standards for summertime heating in compliance with ADL2 for teaching and learning areas are: a There should be no more than 120 hours when the air temperature in the classroom rises above 28ºC b The average internal to external temperature difference should not exceed 5ºC (i.e. the internal air temperature should be no more than 5ºC above the external air temperature on average) c The internal air temperature when the space is occupied should not exceed 32ºC Heat Recovery Heat Recovery is referred to in BB101 as being suitable for several specific application types within the educational framework. It would be inappropriate to supply air directly to a warm classroom at very low external ambient temperatures during the heating season. Heat recovery systems avoid this condition and minimize the fresh air tempering heat requirement. The energy required to condition the outdoor air in winter can be a significant portion of the total space-conditioning load and increasingly so as fabric insulation increases. Air exchange typically represents 20% to 50% of a building s thermal load. The use of heat recovery, particularly where the unit is used to provide the heating function for the room is a worthwhile solution. Controls Effective and control strategies are key to obtaining the lowest levels of energy use in a ventilation system. Basic strategies such as the use of Timelocks or Occupancy detection can provide significant benefits. BB101 refers to the use of Building Management Systems or similar control and the use of demand controlled ventilation as being appropriate. The fans used should be designed for optimized duty control via speed reduction, as this will provide the triple benefit of: reduction of ventilation heat loss, reduction of motor input power and the reduction in system noise levels. Acoustics Acoustic design requirements in schools are extensively dealt with in Building Bulletin 93 (Acoustic Design of Schools). The essential requirement for maximum noise levels to be maintained in teaching areas is readily understood. This translates into a data table covering not only the maximum levels acceptable in the various types of room, but also the classification of the room in terms of its potential to create noise that could affect the other areas, and its level of tolerance to external noise sources. This Table (1.1) is cross referenced in BB101, and is the basic criteria that applies to ventilation systems. The maximum noise level, defined in terms of L A eq (Equivalent continuous sound level) 30 mins (db) is presented, and ranges from levels of 30 for very sensitive areas such as musical performance to 45 for general circulation areas. There is no generalised direct relationship between the room noise level and the sound level generation of the ventilation system. In each case, acoustic analysis is required to establish an acceptable design. Typically the acoustic design issues are the external noise sources. For Mechanical systems, the value quoted must be maintained at all times. The system generated noise is generally the dominant source in this case - which of course may be dealt with by suitable levels of attenuation designed to have a low resistance to airflow. Breakout noise from unit casing and duct work may also be relevant, and although various grades of acoustic enclosure are available, the most effective solution is the careful positioning of the equipment itself. 18 www.nuairegroup.com www.nuairegroup.com 19

Head Office Western Industrial Estate Caerphilly CF83 1NA United Kingdom Telephone: +44 (0)2920 858200 Facsimile: +44 (0)2920 858300 email: info@nuairegroup.com Web site: www.nuairegroup.com Distributed by Telephone: 08705 121400 Facsimile: 08705 121444 email: info@fansdirect.co.uk Web site: www.fansdirect.co.uk Nuaire Group 2008. As part of the policy of continuous product improvement and development, Nuaire reserve the right to alter specifications without prior notice. Designed and produced by Davies-Wise Design Company www.dwdc.co.uk