DIAMOND STRIP DRAIN OWNER S MANUAL VGB 2008 IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF ENTRAPMENT HAZARDS:

Similar documents
ULTRA STRIP DRAIN OWNER S MANUAL VGB 2008 IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF ENTRAPMENT HAZARDS:

IMPORTANT SAFETY INSTRUCTIONS

DUAL SUBMERGED SUCTION OUTLET SET. [Commonly called main drains] Owner s Manual

HAYWARD POOL PRODUCTS, INC. 620 Division Street Elizabeth, NJ Tel:

HAYWARD POOL PRODUCTS, INC. 620 Division Street Elizabeth, NJ Tel:

HAYWARD POOL PRODUCTS POMONA, CA CLEMMONS, NC NASHVILLE, TN

SwimPro by HAYWARD 620 Division Street Elizabeth, NJ Tel:

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS

POOL & SPA SUCTION FITTINGS

70w and 140w Junction Box Transformer Kit For ColorLogic and CrystaLogic Pool, Spa and Accent Lights Spa Lights

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS. Super Pump Series

VL Series Pump. Owner s Manual. NOTE - To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and completely.

Pump - Owner s Manual

Owner s Manual ROBOTIC POOL CLEANER. Models: TigerShark, TigerShark QC, TigerShark Plus, TigerShark2, TigerShark2 Plus IMPORTANT SAFETY INSTRUCTIONS

MDX² INSTALLATION MANUAL

POOL AND SPA/HOT TUB HEATERS H150FD, H200FD, H250FD, H300FD, H350FD & H400FD MODELS OWNER S MANUAL PRINTED 10/24/2011 AT 1:13 PM

HAYWARD POOL AND SPA/HOT TUB HEATERS H150FD, H200FD, H250FD, H300FD, H350FD & H400FD MODELS OWNER S MANUAL

Models: HP20654T, HP20654BT, HP20854T, HP20854BT and HP21104T INSTALLATION GUIDE SAVE THIS INSTALLATION GUIDE

XStream. Owner s Manual. Contents. MODELS: CC1000, CC1500, and Systems IMPORTANT SAFETY INSTRUCTIONS

ProSeries HIGH RATE SAND FILTER. Owner s Manual. Contents. Models S144T S166T S210T S220T S244T S270T S310T2 S180T S210T2 S220T2 S244T2 S270T2 S360T2

CHAMPION PUMP OWNER S MANUAL

HIGH PERFORMANCE PUMP

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS

ACID FEED SYSTEM. Owner s Manual. Model: AQL-CHEM4-ACID IMPORTANT SAFETY INSTRUCTIONS

SMF PUMP OWNER S MANUAL

MODEL VR1000 SERVICE MANUAL INSTALLATION & PARTS

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS SAVE THIS INSTRUCTION MANUAL

SAFETY VACUUM RELEASE SYSTEM (SVRS)

ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL

HIGH PERFORMANCE 3-PHASE PUMPS

HIGH PERFORMANCE PUMPS

ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS

Models: HP20654T, HP20654BT, HP20854T, HP20854BT and HP21104T OWNERS OPERATION & PARTS MANUAL SAVE THIS OWNERS MANUAL

Maxflo VS. Owner s Manual. MaxFlo VS Variable Speed Pump

ProGrid Vertical Grid D.E. Filter

Variable Speed. Installation and User s Guide. Programmable Pump IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS

CHALLENGER CENTRIFUGAL PUMP

INTELLIFLO VF VARIABLE FLOW PUMP

HAYWARD POOL PRODUCTS

Booster Pump. Owner s Manual Model HSP Contents

Variable Speed. IntelliFlo. Installation and User s Guide. Programmable Pump

SERVICE & INSTALLATION MANUAL

QUIETFLO PLUS OWNER S MANUAL INSTALLATION, OPERATION & PARTS SAVE THIS INSTRUCTION MANUAL

VARIABLE SPEED PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

OWNER S MANUAL POOL AND SPA/HOT TUB HEATERS H150FD, H200FD, H250FD, H300FD, H350FD & H400FD MODELS FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS:

HAYWARD POOL PRODUCTS, INC. 620 DIVISION STREET ELIZABETH, NJ (908) OWNER S MANUAL INSTALLATION, OPERATION, & PARTS

Jacuzzi J-D300 Pool Cleaning System

INSTALLATION INSTRUCTIONS

Owner s Manual. Models SP32950VSP Variable Speed Pump SAVE THIS INSTRUCTION MANUAL

HAYWARD POOL AND SPA/HOT TUB HEATERS H150FD, H200FD, H250FD, H300FD, H350FD & H400FD MODELS

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

Max-Flo Owner s Manual

Owner s Manual Guide du propriétaire Manual de Usuario. H Rev -

SERVICE & INSTALLATION MANUAL FOR TR250 & TR400 MODEL POOL AND SPA/HOT TUB HEATERS

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

DYNA-PRO CENTRIFUGAL PUMPS WITH INTEGRAL TRAP

SPARUS 160 ENERGY EFFICIENT AQUACULTURE DUTY PUMP

LIL SHARK TM AUTOMATIC POOL CLEANER. Model GW8000 OPERATION, TROUBLESHOOTING & PARTS. About Safety

OPERATING MANUAL HYDRO POWERED ROBOTIC POOL CLEANER CONTENTS

OWNER S MANUAL IMPORTANT SAFETY RULES. Deluxe Maintenance Kit IMPORTANT! DO NOT RETURN PRODUCT TO STORE. English

Safety Vacuum Release System Installation Instructions. Model VA

OWNER S MANUAL IMPORTANT SAFETY RULES IMPORTANT! DO NOT RETURN PRODUCT TO STORE. English

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING.

Perfect Settings Warranty Information

QUIETFLO OWNER S MANUAL

OPERATION MANUAL VCX-4 Vacuum Coolant Exchanger

Two Tier Illumifalls Patio Pond

MaxFlo VS Owner s Manual

50 HZ. MAX-E-PRO CENTRIFUGAL PUMPS WITH INTEGRAL TRAP

DUST COLLECTOR OPERATION AND SAFETY INSTRUCTIONS FM230 CAUTION: READ THE INSTRUCTION MANUAL BEFORE USING THE APPLIANCE

KREEPY KRAULY PROWLER 910 ROBOTIC ABOVEGROUND POOL CLEANER

Super Pump VS. Model SP2600FVS Super Pump Variable Speed

Installation, Operating, and Service Manual. Badu. EcoM3. Swimming Pool Pump

SERVICE & INSTALLATION MANUAL

HIGH PERFORMANCE POOL & SPA PUMPS

Vac-Alert TM Industries, LLC

OWNER S MANUAL. SilentFlo. Pool Pump. For the Installation, Operation and Service of

SuperFlo High Performance Pump

AUTOMATIC IN-FLOOR CLEANING & CIRCULATING SYSTEM

MAX-E-PRO CENTRIFUGAL PUMPS WITH INTEGRAL TRAP

KREEPY KRAULY PROWLER 920 ROBOTIC INGROUND POOL CLEANER

USER MANUAL UN-200V / UN-200VH

S5 SUCTION SIDE POOL CLEANER

Elite Primer Baldor Series External Pond Pump

Laurel Mountain Whirlpools. Walk-In Bathtub Installation Manual

SAVE THIS INSTRUCTION MANUAL

Patriot. Automatic Pool Vacuum Cleaner. Patent No. 5,794,293. Owner's Guide. Model *Recommended for 3/4 HP and above

IntelliFlo VS+ SVRS Variable Speed Programmable Pump with Safety Vacuum Release System (SVRS) Protection

OWNER S MANUAL. Deluxe Maintenance Kit

English Table of contents Features/Accessories

ECOFLO V3 POOL & SPA PUMP

Robotic Pool Cleaner REVOLUTION I. Operating Instructions Robotic Pool Cleaner REVOLUTION I... p. 1-8

ANGULAR TILE DRILL BEAST FB750W OPERATING MANUAL

2 Front Back ᄠ ౪ᄠ ᑵෂ ۳ෂ

Isolux Arsenic Removal Systems Central Treatment Systems Operation and Maintenance Manual

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

ASSEMBLY INSTRUCTIONS

COMMERCIAL STRENGTH POLYMER MEDIA FILTER OWNERS MANUAL

Transcription:

VGB 008 DIAMOND STRIP DRAIN OWNER S MANUAL WARNING IMPORTANT SAFETY INSTRUCTIONS Read and keep these instructions for future reference. Follow all instructions in this owner s manual and on the equipment. Failure to follow instructions can cause severe injury and/or death. WARNING - SUCTION ENTRAPMENT HAZARD Suction in suction outlets and/or suction outlet covers which are damaged, broken, cracked, missing, or unsecured can cause severe injury and/ or death due to the following entrapment hazards: Hair Entrapment: Hair can become entangled in suction outlet cover. Limb Entrapment: A limb inserted into an opening of a suction outlet sump or suction outlet cover that is damaged, broken, cracked, missing, or not securely attached can result in a mechanical bind or swelling of the limb. Use two or more suction fitting on each pump suction line. The suction fittings shall be separated by a minimum of 3 ft. (91.44 cm), or if any are located closer they shall be located on two different planes (i.e., one on the bottom and one on the vertical wall, or one each on two separate vertical wall). In the event of one suction outlet being completely blocked, the remaining suction outlets serving that system shall have a flow rating capable of the full flow of the pump(s) for the specific suction system. Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas. The maximum system flow rate shall not exceed the flow rating of For Model Number: 640-134x V 640-135x V 640-136x V 640-137x V TO REDUCE THE RISK OF ENTRAPMENT HAZARDS: Body Suction Entrapment: A negative pressure applied to a large portion of the body or limbs can result in an entrapment. Evisceration / Disembowelment Entrapment: A negative pressure applied directly to the intestines through an unprotected suction outlet sump or suction outlet cover which is damaged, broken, cracked, missing, or unsecured can result in evisceration / disembowelment entrapment. Mechanical Entrapment: There is potential for jewelry, swimsuit, hair decorations, finger, toe, or knuckle to be caught in an opening of a suction outlet cover resulting in mechanical entrapment. any listed (per ASME A11.19.8-007) suction outlet cover installed. In the event of one suction outlet being completely blocked, the remaining suction outlets serving the system shall have a flow rating capable of the full flow of the pump(s). Never use a pool or spa if any suction outlet component is damaged, broken, cracked, missing, or not securely attached. Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately. Two or more suction outlets per pump should be installed in accordance with latest APSP Standards and CPSC guidelines, and follow all National, State, and Local codes applicable. Replace the suction within 7 years from the installation date. Installation of a vacuum release system, which relieves entrapping suction, is recommended. USE ONLY GENUINE WATERWAY REPLACEMENT PARTS. 00 East Sturgis Road, Oxnard, CA 93030 Ph. (805) 981-06 Fax (805) 981-9403 www.waterwayplastics.com waterway@waterwayplastics.com

WARNING Failure to remove pressure test plugs and/or plugs used in winterization of the pool/spa from the suction outlets can result in an increased potential for suction entrapment as described on the previous page. Failure to keep suction outlet components clear of debris, such as leaves, dirt, hair, paper and other material, can result in an increased potential for suction entrapment as described on the previous page. Suction outlet components have a finite life. The cover/grate should be inspected frequently and replaced at least every seven years, or if found to be damaged, broken, cracked, missing, or not securely attached. This fitting is rated at 80 GPM when mounted on the floor and 16 GPM when mounted on the wall when only one port on the center of the sump is used. This fitting is rated at 30 GPM when mounted on the floor and 40 GPM when mounted on the wall when two ports on the sump are used. If the fitting is missing or broken, replace with a fitting of equivalent rating or higher. Use of a lower rated suction fitting could result in entrapment of the body which could result in serious injury including drowning. Do not use or operate pool, spa, or hot tub if this suction fitting is missing, broken or not secured per instructions. The suction fitting is intended to prevent entrapment of the body. Use of the spa hot tub with a missing, broken or improperly secured suction grate may result in serious personal injury including drowning. When the pool, spa or hot tub is in operation, suction is created at this fitting. Users of the spa or hot tub must be instructed not to come in contact with this fitting in such a way as to block its orifice. If a user of the spa or hot tub blocks this fitting with his/her body, serious personal injury or drowning may occur. In order to remove the suction cover (for service or winterization), using a Phillips-head screw driver remove the screws. Inspect both the suction cover and suction fitting for any cracks or damages. It is imperative to securely attach the suction cover to the wall fittings (use only the original supplied screws or obtain original replacements). Do not over tighten the screws. Inspection of fasteners and observation for damaged/tampered with suction fittings is required. Any and all broken or missing parts must be replaced prior to starting spa or pool pump. Never operate spa or pool without drain cover in place and properly affixed, death or serious injury can result. Do not exceed the safe flow rate. Do not increase flow through system by increasing pump size or horsepower. Do not allow children to sit, play or interact with main drains or suction outlet.

640-134x V DIAMOND STRIP DRAIN COMPONENTS - VINYL 7 6 5 4 3 Item Part No. Description Quantity 1 64-134x V 3" Diamond Pattern Grate 1 819-1031 #8 x 1" Screw 38 3 64-1350 Vinyl Liner Retainer Plate 1 4 711-4470 Vinyl Liner Mounting Plate Gasket 1 5 715-9910 " Pipe Plug 3 6 64-1300 3" 3-Port Vinyl Liner Sump 1 7 715-1360 3" Plaster Cover/Plug 1 WARNING: The Plaster Cover/Plug shall be removed prior to assembly of the Grate. Hand tighten the screws using a Phillips screw driver. DO NOT use electrical or pneumatic tools for tightening the screws.

640-135x V DIAMOND STRIP DRAIN COMPONENTS - FIBERGLASS 7 5 6 4 3 1 Item Part No. Description Quantity 1 64-134x V 3" Diamond Pattern Grate 1 819-1031 #8 x 1" Screw 38 3 64-1350 Retainer Plate 1 4 711-4470 Mounting Plate Gasket 1 5 711-4460 Body U-Gasket 1 6 715-9910 " Pipe Plug 3 7 64-1300 3" 3-Port Vinyl Liner Sump 1 WARNING: The Plaster Cover/Plug shall be removed prior to assembly of the Grate. Hand tighten the screws using a Phillips screw driver. DO NOT use electrical or pneumatic tools for tightening the screws. 4 010 Waterway Plastics

640-136x V DIAMOND STRIP DRAIN COMPONENTS - CONCRETE 1 3 5 4 Item Part No. Description Quantity 1 819-1031 #8 x 1" Screw 8 64-134x V 3" Diamond Pattern Grate 1 3 715-9910 Pipe Plug 3 4 64-130 3" 3-Port Plaster Sump 1 5 715-1360 3" Plaster Cover/Plug 1 WARNING: The Plaster Cover/Plug shall be removed prior to assembly of the Grate. Hand tighten the screws using a Phillips screw driver. DO NOT use electrical or pneumatic tools for tightening the screws.

640-137x V DIAMOND STRIP DRAIN COMPONENTS FIELD BUILT SUMPS 1 3 4 Item Part No. Description Quantity 1 819-1031 #8 x 1" Screw 8 64-134x V 3" Diamond Pattern Grate 1 3 64-1360 3" Plaster Ring 1 4 715-1360 3" Plaster Cover/Plug 1 WARNING: The Plaster Cover/Plug shall be removed prior to assembly of the Grate. Hand tighten the screws using a Phillips screw driver. DO NOT use electrical or pneumatic tools for tightening the screws.

INSTRUCTIONS FOR THE USE OF FIELD BUILT SUMPS Use " or larger PVC hose or pipe. FIELD BUILT SUMP GENERAL NOTES: (a) D = inside diameter of pipe. (b) All dimensions shown are minimums. (c) A broken line ( - - - ) indicates suggested sump configuration. The design of field fabricated sumps shall be further specified by a Registered Design Professional so as to fully address the considerations of cover/grate loadings, durability, hair, finger, and limb entrapment issues, as well as features particular to the site.

DIAMOND STRIP DRAIN HEAD LOSS CURVE.5 Head Loss Curve - Diamond Strip Drains Head (In. Hg.) 1.5 1 0.5 0 0 50 100 150 00 50 300 350 400 450 500 Flow Rate (GPM)