D454.F.CE Product Guide

Similar documents
E529 Smart Digital Thermostat Product Guide

S541.RF 4G Product Guide

DD15 Interface Module Product Guide

DALI Product Range. Designed in Australia to be compatible for all DALI systems. gerardlighting.com.au

INNtouch PRIVACY MAKE UP ROOM P564

Power Supply Display Module PSDM. Installation and Operation Manual

Greentrol Automation, Inc.

Booster Power Supply Manual

CR Series Command Relays

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Model 4880 Status Output Display Module Manual

MBCE-110/230FR Flame Sensor Module

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

Hi-lume 3D Overview. Fluorescent Dimming Ballasts

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

C-Bus Four Channel Analogue Output Unit Installation Instructions

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Welcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647

USER MANUAL TUNGSTEN SMART-HEAT ELECTRIC WIRELESS DIMMER CONTROLLER BY BROMIC IMPORTANT

Hi-lume 3D Overview. Fluorescent Dimming Ballasts Hi-lume 3D Architectural Dimming

Product Bulletin for Decora Rocker Slide Controls

4100U City and Relay Cards Installation Instructions

MBCE-110/230UV Flame Sensor Module

Model 17A00 Expansion Enclosure

SECTION LIGHTING CONTROLS

Operation Manual Model: Light Switch Combo Universal Dimmer Module Item No.: WMR-252. Specification. Wiring

START-LINE Receiver ACD-200. SMART Home USER MANUAL. Version 1.0 Visit for the most recent user manuals MAINS SOCKET DIMMER

HOME LOAD MANAGER INSTALLATION MANUAL Hardware Revision 1.4 & Higher

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

CLS-EXP-DIM. Functional Summary. Specifications

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Miro Wireless Dimming and Scene Control Made Elegantly Simple

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

Remote Controls POOL SPA & FILTRATION SUPPLIES (PTY) LTD REMOTE SYSTEMS

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

T4398A,B Precision Electric Heating Thermostat

NEW. lighting management - stand alone detectors, power packs. Passage detection - Infrared technology. Detectors with power packs

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

MBCE-110/230FR Flame Sensor Module

DRC12FR DRC12FR347. Dynalite. Install Guide

SECTION 26 NX DISTRIBUTED INTELLIGENCE LIGHTING CONTROL SYSTEM HUBBELL CONTROL SOLUTIONS

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

GPF Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

INSTALLATION MANUAL. ION-CUBE Series. LED Wall Washer CLASS 2 E359853

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

SECTION LOW VOLTAGE LIGHTING CONTROLS

Universal Fan and Light Remote Control

ENERGY EFFICIENCY EXPERTS

ESRB and ESRN Installation & Safety Instructions

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

RAM3 Remote Alarm Module

Revolutionise your smart home at the touch of a button...

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

CDMAEZ. CDMA Universal Alarm Communicator INSTALLATION & USER S GUIDE

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current. Output Voltage Range

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Linear Lighting Pro Dimmable Series XLAV80. Constant Voltage Dimmable LED Driver. Features. Model Selection Key 80-BCV-D

C-Bus Four Channel General Input Unit Installation Instructions

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

TruPortal Wireless Locks Quick Reference

Stellar Panelboard Dimming Systems

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

DIMAX DIMAX D GB F I E NL. Installation and operating instructions Universal dimmer DIMAX 532. Minimum DIMAX 532.

Powerley Thermostat. Installation & Operation Guide

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

USER MANUAL TUNGSTEN SMART-HEAT ELECTRIC WIRELESS DIMMER CONTROLLER BY BROMIC IMPORTANT

HTC-915-CONT. Heat-Trace Control system

600 Watt Dimmer Install Guide

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Appendix A Equipment Used to Monitor Hotels

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Ammonia Leak Detector Manual

Relay Panel and Relay Panel Module Wiring and installation manual Light is OSRAM

ECO N DATE DESCRIPTION OF CHANGE CHG

Operations Manual. Motion Detector Module Model ZS10

SAFETY INFORMATION AND WARNINGS

EcoSystem H-Series Ballasts

NGC-40-IO Control and monitoring modules for use with the Raychem NGC-40 system Installation Instructions

Independent Zone Control (I.Z.C.)

Skydance offers a complete AC Triac control system that contains Triac dimmer/ switch, Traic dimmable LED driver, and DMX512 Triac Converter.

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

Resistance heaters. Ventilation systems. Air-air exchangers. Air-water exchangers. Cooling units. Control devices. Calculation and selection

FTP-1000 Touchpad/Display Installation Manual

Green Point. IR Bridge User Manual. Green Point

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Predator Controller Hardware Family

Dimmer Switch (3 Gang)

7800 SERIES RM7888A Relay Module

INNCOM e7 Thermostat User Guide

T7079A,B Solid State Remote Temperature Controllers

Installation Instructions

Transcription:

D454.F.CE Product Guide Table of Contents Table of Contents... Page 1 Overview and General Concept... Page 2 Application... Page 2 Features... Page 3 Typical Wiring Applications... Page 3 Installation Requirements... Page 5 Mounting... Page 5 Din Rail Mounting... Page 5 Standard Mounting... Page 5 Line Power Connections... Page 6 Safety Warnings... Page 6 Low Voltage Connections... Page 7 Header Specifications... Page 7 Regulatory Approvals... Page 9 Listed Load Ratings... Page 9 Environmental Specification... Page 9 Technical Specifications... Page 10 Physical Specification... Page 10 Ordering Information... Page 10 Document Revision History... Page 10 Rev. 3 Date 3/17/2017 1

Overview and General Concepts The D454.F.CE (the D454-F) 2 channel light dimmer provides up to 800W of dimming power, 400W per channel. The D454.F.CE is a central component in the INNCOM Integrated Room Automation System (IRAS) when used with S-Series, EVORA, or Glass Series switches. Figure 1. D454.F.CE Application The D454.F.CE can be used in many different lighting circuit topologies. Typically the D454.F.CE dims lighting loads when products such as the Glass Series or other low-voltage switches such as the S-and Designer-Series switches are configured for lighting control. In high-end applications, multiple D454-Fs can be easily daisy-chained and used in conjunction with other load bearing wall box dimmers such as the 350W dimmable Evora FET. This allows the designer to create a seamless, multi-point lighting control application that meets nearly any interior design requirement. The D454.F.CE is specifically designed to meet applications where linevoltage wiring has been pulled to a centralized location, such as a load center. The D454.F.CE can be integrated into the IRAS low-voltage wiring using S5-bus and wireless, Infrared (IR) or RF (Radio Frequency). The D454.F.CE provides up to 255 dimming levels. This provides fine control over specific light levels and light ramping speed in the guestroom to achieve the highest level of comfort and control. Rev.3 Date 3/17/2017 2

Features Dimmable loads up to 550W per channel or 800W dual channel. Wired S5-bus communication for IRAS controls. Optional IR or RF communication is also available. Daisy-chainable for multi-point, complex lighting applications. Fully enclosed housing to protect electronic components. Standard or DIN-rail mounting options with a compact mechanical design. Air-gap switch for added safety. FCC and CE Mark listed for international applications. Typical Wiring Applications Figure 2: D454.F.CE and Glass Series Application In this IRAS configuration, the D454.F.CE provides the load bearing capability for the Glass Series switch. The 2-channel D454.F.CE can be configured to provide a variety of light moods to meet the requirements of many specific applications. Rev.3 Date 3/17/2017 3

Figure 3: D454.F.CE and S-Series - EVORA Application In this IRAS application, the D454.F.CE provides the dimming capability for more complex lighting control. As shown in Figure 3 above, any S- Series switch or EVORA can dim either channel of the D454.F.CE using RF and S5-bus network connections, as well as dimming its own load. This allows the designer to create many distinct lighting moods that can be controlled from anywhere within the guestroom. Note: The load bearing EVORA products in this diagram require a phase and neutral to dim the local loads. Rev.3 Date 3/17/2017 4

Installation Requirements The installer must be a trained, experienced service technician. When installing this product: 1. Read the instructions carefully. Failure to follow them could damage the product or cause hazardous conditions. Figure 4: D454.F.CE Mounting 2. Check the ratings given in the product guide to make sure the product is suitable for your application. Mounting The D454.F.CE is provided with a DIN rail snap assembly and screw mounts in the bottom housing for multiple installation environments. DIN Rail Mounting: 1. Mount the DIN rail (supplied separately) to the intended device (NEMA box, wall mount, etc.). 2. On the bottom housing, pull the plastic tab out and mount the D454.F.CE on the DIN rail. Release the plastic tab. This locks the D454.F.CE to the DIN rail mounting assembly. Standard Mounting: 1. Remove the top cover of the D454.F.CE by pressing in the tabs at both ends of the unit to release it. 2. Remove the PCBA by pulling back on the 4 tabs locking the PCBA to the bottom housing. 3. Once the PCBA is removed, use the 4 countersunk mount posts in the base housing to screw the device to its intended application. 4. Place the PCBA back onto the bottom housing and confirm that it snaps into place. 5. Replace the top housing. Rev.3 Date 3/17/2017 5

Line Power Connections Safety Warning CAUTION Brach circuit breakers must be used to meet local electrical code. The D454.F.CE is intended for INDOOR USE ONLY. Separation of Class-1 and Class-2 Circuits must be observed. Use copper conductors ONLY. Figure 5: Line Voltage Connections TB1, TB2, and TB3 screw terminals require a minimum 4.4 inchpounds of torque to meet NEC requirements. For use in Pollution Degree 2 Environments Only. NOTE: This product requires an air-gap switch such as a UL #20 switch with an identified off position between the line and load terminals. When using the D454.F.CE with on-board relay, the red LED will blink to indicate the load is disconnected from the line power. Rev.3 Date 3/17/2017 6

Low Voltage Connections The D454.F.CE does not require an external power supply. Earth GND must be connected to ensure proper communications function of the D454-F.CE. 1. Remove the top cover of the D454.F.CE by pressing the tabs at both ends of the unit to release it. 2. Connect S5-bus, 12VDC, and GND to either S5-bus 3-pin header as shown below. 3. Connect the IR Eye5 cable to the IR5 header as shown below (where IR communications are necessary). 4. Use the cable channels to route the low voltage wiring in and out of the unit enclosure. Figure 6: Header and LED description D454.F.CE Header Specification TB3 Input Voltage 1 Neutral 220-240VAC 50/60Hz Input 2 Hot 220-240VAC 50/60Hz Input 3 Neutral 220-240VAC 50/60Hz Input 4 Hot 220-240VAC 50/60Hz Input Rev.3 Date 3/17/2017 7

TB2 Channel 2 Dimmer Output 1 Neutral Dimmer Output 2 Switched Hot / FET Out Dimmer Output TB1 - Channel 1 Dimmer Output 1 Neutral Dimmer Output 2 Switched Hot / FET Out Dimmer Output H2 & H3 S5 Bus 1 GND Ground 2 VEE Power (+12VDC) 3 S5BUS Communication bus H4- System 5 (Legacy Only) 1 COM Ground 2 12VDC Power (+12VDC) 3 S5bus Communication bus 4 IR5TX Transmit 5 IR5RX Receive H5 IR5 (Legacy Only) 1 GND Ground 2 AGC Accelerated Gain Control 3 12VDC Power (+12VDC) 4 IO2 Open-Collector Output 5 IO3 0-5VDC Dry Contact Inputs H6 Expansion I/O 1 GND Ground 2 12VDC Power (+12VDC) 3 IO1 Open-Collector Output 4 IO2 Open-Collector Output 5 IO3 0-5VDC Dry Contact Inputs 6 IO4 0-5VDC Dry Contact Inputs 7 IO5 0-5VDC Dry Contact Inputs Rev.3 Date 3/17/2017 8

H1 ISP Programming Header 1 GND Power 2 VCC Power (+3.3V) 3 SCI2_TX Transmit 4 SCI2_RX Receive 5 NRST Reset 6 SWO Oscillator 7 SWCLK Clock 8 SWDIO Power Regulatory Approvals The following table provides the safety and regulatory standards for the load ratings and types. Listing CE-Mark Specification EN60669-1:1999+A1:2002+A2:2008 EN60669-2-1:2004+A1:2009+A12:2010 EN61000-3-2:2006/A1:2009/A2:2009 EN 61000-3-2:2014 Supersedes all amendments on June 30, 2017 EN61000-3-3:2008 EN61000-6-3:2007/A1:2011 EN61000-6-1:2007 Listed Load Ratings Load Types Incandescent / Halogen UL Listed Load Ratings 100-120VAC Single Channel 5.5A at 100Vac 4.5A at 120Vac UL Listed Load Ratings 100-120VAC Dual Channel 8A at 100Vac 6.6A at CE-240VAC Ratings Single Channel 2.75A 4A CE-240VAC Ratings Dual Channel 120Vac Resistive 4.5A 6.6A 2.75A 4A ELV / Electronic Ballast 500VA 750VA 500VA 750VA CFL / LED 2.5A 4A 2.5 4A Note: D454.F.CEis not intended to use with magnetic transformers or any inductive loads Environmental Specification Specification Min Nom Max Units Operating 0 25 30 C Temperature Storage Temperature -40-70 C Relative Humidity 5-95% %RH Rev.3 Date 3/17/2017 9

Technical Specifications Class 2 Input/ Current Consumption Parameter memory 12VDC, 100mA Non volatile Physical Specification Dimension Measure Unit Length 157.2/6.18 mm/in. Height 49.6/1.95 mm/in. Width 86.6/3.40 mm/in. Ordering Information Model # 201-928.CE Description D454.F.CE 2-channel dimmer: UL,CSA and CE Mark listed Document Revision History Revision Date issued Reason for change V0.1 10-Aug-2015 First Release Rev.2 09-Aug-2015 Rebranding for Honeywell Rev.3 17-Mar-17 Total Honeywell Branding overview with New logo The material in this document is for information purposes only. The content and the product it describes are subject to change without notice. Honeywell makes no representations or warranties with respect to this document. In no event shall Honeywell be liable for technical or editorial omissions or mistakes in this document, nor shall it be liable for any damages, direct or incidental, arising out of or related to the use of this document. No part of this document may be reproduced in any form or by any means without prior written permission from Honeywell. Copyright 2017 by Honeywell International, Inc. All Rights Reserved. Honeywell I 277 West Main Street I Niantic, CT 06357 I Phone: 1.860-739-4468 I www.inncom.com Rev.3 Date 3/17/2017 10