Flame detector. Building Technologies Division Infrastructure & Cities Sector

Similar documents
Flame detector. The QRA4.U is for use with the following types of burner control:

Flame detector. The QRA4.U is for use with the following types of burner control:

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

QRA10... QRA53... QRA55...

QRA10... QRA53... QRA55...

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products

QRA10... QRA53... QRA55...

QRA10... QRA53... QRA55...

Infrared Flame Detectors

Flame Safeguards LFE10. Building Technologies HVAC Products

Flame Safeguards LFE10. Building Technologies HVAC Products

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

Infrared Flame Detectors

RAR... Photocell Detectors. Building Technologies Division

QRC1... Blue-flame Detectors. Siemens Building Technologies HVAC Products

UV Flame Supervision System

LAE10 LFE10. Use. Series 02

Blue-flame Detectors

LOA44.252A27. Oil Burner Control. Building Technologies HVAC Products

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

C Note! LGI16... Burner Controls. Building Technologies

Oil Burner Controls LOA3... Building Technologies HVAC Products

LGA... Gas Burner Controls. Building Technologies Division

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

Oil Burner Controls LMO24... LMO44...

Oil Burner Controls LMO24... LMO44...

Basic unit with integrated air-fuel ratio control for forced draft burners

Basic unit with integrated fuel-air ratio control for forced draft burners LMV Building Technologies Division

Basic Unit with integrated Fuel / Air Ratio Control for Forced Draft Burners LMV Building Technologies

Burner Management System

Oil Burner Controls LOA3... Building Technologies Division

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies HVAC Products

Burner controls. Building Technologies HVAC Products

Heating Element. Building Technologies HVAC Products

LFL Series Burner Flame Safeguard Control

Burner Management System

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies Landis & Staefa Division

Burner Management System

UV - flame detector dual fuel burners for intermittent burner operations

Burner Controls. Building Technologies HVAC Products

Gas Burner Controls. Building Technologies HVAC Products

Use. The burner controls are certified to EN 230 and EN 298.

for relative humidity and temperature with calibration certificates

Use. Burner controls for use with forced draught gas or gas / oil burners of small to medium capacity in intermittent operation.

Safety. Operating instructions UV sensor UVS 5 DANGER. Contents WARNING CAUTION Elster GmbH Edition Please read and keep in a safe place

Product Range Overview

Room Temperature Sensor

for relative humidity and temperature

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

Forced draught gas burner

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Program module for burner control LME71.000

Room Temperature Sensors

Room Air Quality Sensors

for relative humidity and temperature

FLV 40 UV Flame Detector

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

EUROBOX SERIES TYPES CM... SM... MM...

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Building Technologies Division

Chemical Processes in the Combustion

COMPACT FLAME CONTROLLER CFC 100

MBCE-110/230UV Flame Sensor Module

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

This document is a preview generated by EVS

Silicon UVAB Sensor E xxx

Section 1 Overview. Introduction 1-1

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

Silicon Pyranometer GSM xx

Electronic timeswitch

FIREYE C9707A ALL FUEL SCANNER

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

Main Features. Functions. with automatic ignition and control functions for the heating and domestic hot water circuit

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Eclipse 90 UV Scanner Model A Version 1

Room air quality sensors

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

General safety precautions English

RIELLO 40 GS/M SERIES

Advanced Ultraviolet Burner Controller

Building Technologies

MMG Gas burner safety control

RD99 REFRIGERANT GAS LEAK DETECTOR WARNING!

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

Distributed By: M&M Control Service, INC

LME75... Burner controls. Building Technologies

QFM21... Duct sensors. Symaro. for relative humidity and temperature

InstrumentationTools.com

REA22 Room Temperature Controller

Gas cylinder scale Model GCS-1

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Transcription:

7 711 Flame detector QRA4 UV flame detector for use with burner controls from Siemens for the supervision of gas or oil flames. The QRA4... and this Data Sheet are intended for use by OEMs which integrate the flame detectors in their products. Use The flame detector is used for the supervision of gas flames, yellow- or blue-burning oil flames and for ignition spark proving in intermittent operation. The QRA4... is for use with the following types of burner control: QRA4.U QRA4M.U Burner control Data Sheet --- LFL... N7451 --- LFE1... N7461 --- LFE10... N7781 --- LGB2... / LGB4... with AGQ1... N7435 --- LME21...C2 / LME22...C2 with AGQ3... N7101 --- LME39...C2 with AGQ3... N7106 --- LME41...C2 / LME44...C2 with AGQ3... N7101 --- LME7... N7105 LMV26.300... with AGM60.1... N7547 LMV27.100 N7541 LMV36.520... with AGM60.4... N7544 LMV37.4 N7546 --- LMV5... with AGQ1... N7550 Other burner controls on request. 08.08.2014 Infrastructure & Cities Sector

Warning notes To avoid injury to persons, damage to property or the environment, the following warning notes must be observed! Do not open, interfere with or modify the flame detector! Siemens will not assume responsibility for damage resulting from unauthorized interference! All activities (mounting, installation and service work, etc.) must be performed by qualified personnel Before making any wiring changes in the connection area, completely isolate the plant from mains supply (all-polar disconnection). Ensure that the plant cannot be inadvertently switched on again and that it is indeed dead. If not observed, there is a risk of electric shock hazard. Ensure protection against electric shock hazard by providing adequate protection for the connection terminals. If this is not observed, there is a risk of electric shock Each time work has been carried out (mounting, installation, service work, etc.), check to ensure that wiring is in an orderly state. If this is not observed, there is a risk of loss of safety functions and a risk of electric shock Halogen lamps, welding equipment, special lamps or ignition sparks may produce sufficient radiation for the detector s UV cell to ignite. X-rays and gamma radiation can also generate erroneous flame signals. If this is not observed, there is a risk of loss of safety functions Fall or shock can adversely affect the safety functions. Such detectors must not be put into operation, even if they do not exhibit any damage. If this is not observed, there is a risk of loss of safety functions and a risk of electric shock Mounting notes Ensure that the relevant national safety regulations are complied with Installation notes Always run the high-voltage ignition cables separate while observing the greatest possible distance to the detector and to other cables Electrical connection of the flame detector It is important to achieve practically disturbance- and loss-free signal transmission: Never run the detector cable together with other cables Line capacitance reduces the magnitude of the flame signal Use a separate cable Observe the permissible lengths of the detector cable (refer to «Technical data» of burner control / basic documentation used) The connecting wires must be run through protective tubing (made of plastic or earthed metal) 2/6

Commissioning notes Trouble-free burner operation is ensured only when the intensity of UV radiation at the detector s location is high enough for the detector s UV cell to ignite during each half wave. The intensity of UV radiation at the detector s location is checked by measuring the detector current (refer to Data Sheet of the respective burner control) Measuring circuit for QRA4... weiß rot Legend 1) Connection of microammeter across adapter AGQ1... / AGQ2... / AGQ3... and flame detector A Incidence of radiation M Microammeter (DC), internal resistance 5,000 C Electrolytic capacitor 100...470 µf, DC 10...25 V Standards and certificates Only in connection with the burner control Conformity to EEC directives - Electromagnetic compatibility EMC (immunity) - Directive for gas appliances - Low-voltage directive 2004/108/EC 2009/142/EC 2006/95/EC ISO 9001: 2008 Cert. 00739 ISO 14001: 2004 Cert. 38233 Service notes The UV cell is glued inside the housing and cannot be removed. When the end of the UV cell s service life is reached, the complete flame detector must be replaced. Disposal notes The flame detector contains electrical and electronic components and must not be disposed of together with domestic waste. Local and currently valid legislation must be observed. Mechanical design Flame detector QRA4... UV flame detector for frontal illumination. Housing made of aluminum, with ¾ -14NPSM connecting thread for fitting the detector to the burner or boiler. Connecting wires of about 1.8 m length for the electrical connection. ½ -14NPSM thread for a fitting, required for the connection of a Menzel tube for protecting the connecting wires (½ conduit). 3/6

Ordering Type QRA4.U QRA4M.U Sensitivity Normal High When ordering, please give the complete type reference according. Accessories Product no. Designation Mounting coupling Adapter of QRA4...-NPSM thread for a European pipe thread (G1"). QRA4... 7711z01e/1013 3/8 cooling air supply AGG15 Heat insulating piece between QRA4... and mounting coupling. AGG15 QRA4... 7711z02/1113 Heat insulating piece AGG15 4/6

Technical data General detector data Average life of UV cell Perm. combustion chamber pressure Degree of protection Mounting position Weight Device safety class Length of connecting wires Conduit for protective sleeve (Menzel sleeve) Approx. 10,000 hours at max. +50 C, higher ambient temperatures reduce considerably the cell s life Max. 150 mbar IP54 (to be ensured through mounting) Optional Approx. 180 g II (double-insulated) Approx. 1,800 mm ½ -14NPSM thread Environmental conditions Storage IEC 60721-3-1 Climatic conditions Class 1K3 Mechanical conditions Class 1M2 Temperature range -20...60 C Humidity <95% r.h. Transport IEC 60721-3-2 Climatic conditions Class 2K3 Mechanical conditions Class 2M2 Temperature range -20...60 C Humidity <95% r.h. Operation Climatic conditions Mechanical conditions Temperature range Humidity IEC 60721-3-3 Class 3K5 Class 3M5-20...60 C <95% r.h. Caution! Condensation, formation of ice and ingress of water are not permitted! If this is not observed, there is a risk of loss of safety functions and a risk of electric shock. Function With this type of flame supervision, the UV radiation emitted by gas or oil flames is used to generate the flame signal. The radiation detector is a UV-sensitive cell with 2 electrodes, which ignite when illuminated with radiation in the 190...270 nm range of the spectrum, thereby triggering a current in the flame detector circuit. The UV cell does not respond to glowing firebrick in the combustion chamber or to daylight. 5/6

Dimensions Dimensions in mm Flame detector QRA4... O 30.5 O 35 7711m03e/1210 108 19 Thread 3/4-14NPSM M1:1 Thread 1/2-14NPSM Mounting coupling 69.9 ±0.5 3/4" - 14 NPSM Pipe thread ISO 228/1-G1 SW 36 3/8 cooling air supply 7711m02e/1010 SW 21 2009 2014 Siemens AG Building Infrastructure Technologies & Cities HVAC Sector Products Building GmbH Technologies Division 6/6 Subject to change!