TECHNICAL INSTRUCTIONS

Similar documents
TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

Detailed Cleaning Instructions

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

OR Replacement Instructions Heat Exchanger Assembly, ASME

Installation Manual. Models 99168, 99169, 99170

Heat Exchanger Block Replacement Instructions

Ti/Lx 150 ASME HX ASSEMBLY

STOP! Read this notice. STOP! Read before proceeding. These instructions are for gas conversion of the Evergreen boiler only.

MODEL SK2750. COMPRESSOR SERVICE KIT For use on 2750 Series Compressors

MODEL COMPRESSOR SERVICE KIT For use on Midmark Power Air Oil-less Compressor Models P21, P22 & P32

CONSTANT SUCTION UNIT

Installation Instructions for the PITCO Self-Cleaning Burner System

Installation Instructions

TopTier tm. Modular Brewing Stand. Operation, Assembly & Maintenance Manual

GV Series 4 Section Assembly

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

Service Parts, Kits and Accessories

MODEL SK2660 COMPRESSOR SERVICE KIT. For use on 2660 and 2680 Model Compressors

MODEL SK2660 COMPRESSOR SERVICE KIT. For use on 2660 and 2680 Model Compressors

ASSEMBLY and INSTALLATION INSTRUCTIONS. Pipe wrench Ratchet 3/8 socket 9/16 socket 11/16 socket 3/16 Allen key 3/32 Allen key 9/64 Allen key

INSTALLATION INSTRUCTIONS # BURNER ASSEMBLY REPLACEMENT

MEGATRON MODEL 2, 3, 4, and 5

HX Field Replacement Kit

Corn Flame Energy Corn Stove Model 3000

COMBUSTION AIR SYSTEM

INSTALLATION GUIDELINES

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

AmazonBasics Patio Heater B00LILH3V4 B00LILH47C B010VFKZEO

D1/D2 Direct Vent Pilot Replacement Model #: D INSTALLER: Leave these instructions with consumer. CONSUMER: Retain for future reference.

COMBUSTION AIR SYSTEM Model: CAS-3

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

1 of 3 5/4/ :44 AM

Advanced Test Equipment Rentals ATEC (2832) Installation Note

VENTING APPLICATION GUIDE

DRAIN WATER TEMPERING INSTALL

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

Lifetime Limited Warranty

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

Ceiling Fan Blade Arm Replacement

ModulAir Air Dryer with External Purge Tank - Changeover from Bendix AD-IS for Peterbilt Installation. Air Dryer Mounting Bracket (Item 1)

Patio Heater_ _V4_ENG.book Page 1 Tuesday, September 2, :00 AM. AmazonBasics Patio Heater B00LILH3V4 B00LILH47C B010VFKZEO

V SERIES HDR GAS RANGES

OPERATING MANUAL CLEAN BURN MODEL: SF-100

Platen Heater Pad Replacement

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

Model SSV-399 GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES

REPLACEMENT PARTS LIST WARNING

GA3650TB Blower Accessory

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Installation and Maintenance "L" and "LS" Series

MEMOIRS VITREOUS CHINA TOILETS

Fuel Conversion Kit Instructions

TECHNICAL INSTRUCTIONS

USER MANUAL UN-200V / UN-200VH

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

WARNING. Failure to install this kit within the guidelines might adversely affect safety, performance, component life and warranty coverage.

BOILER APPLICATION GUIDE for:

BMW E36 Thermostat Removal And Coolant Flush

User s Information Manual

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Dust Collector. Sizes DC1 and DC2 U S E R G U I D E UGC

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

Instruction Manual. This manual must be read and the requirements carried out to ensure satisfactory performance.

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

Glendale 52 in Ceiling Fan Owner's Manual. Glendale Ventilador de Techo de 1.32 m Manual del Propietario

Installation Instructions

Please read this manual completely before attempting to install, operate or service this equipment.

USER MANUAL Installation, Operation, and Maintenance

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Audi-Larm Audible Alarm

9. Check condensate piping for sagging and/or leakage. Repair any sags or leaks before restoring power to the appliance.

Welcome! Today s topic: Small Home Repairs. November 14, 2015

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL


INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA)

18 INCHES, OSCILLATING STAND FAN

Evergreen Liquid Propane Conversion

HE360 Humidifier Installation Kit

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

Minor Home Repairs. November 4, County of Henrico Department of Community Revitalization

Heat Exchanger Tube Change Procedure

MG SERIES GAS OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE M24G M36G MODELS

Sunpak Infrared Heater. Model S34 TSR

INGERSOLLrAND AIR COMPRESSORS CAUTION: HMD SERIES AIR DRYERS MODELS 18 THROUGH 385 OPERATORS/ INSTRUCTION MANUAL REPLACEMENT PARTS

Grant Spira 6-26kW and 9-36kW Wood Pellet Boilers

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

SECTION AUXILIARY HEATER

Transcription:

TECHNICAL INSTRUCTIONS Annual Maintenance Kit For Benchmark 750-1000 Boilers Maintenance Flame Detector P/N 66034 Ignitor- Injector P/N 58023 Gasket P/N 81048 Condensate Trap O-Ring P/N 84017 Condensate Trap Orifice Gasket P/N 81092 Created 04/03/2014 Disclaimer The information contained in this manual is subject to change without notice from AERCO International, Inc. AERCO makes no warranty of any kind with respect to this material, including, but not limited to, implied warranties of merchantability and fitness for a particular application. AERCO International is not liable for errors appearing in this manual. Nor for incidental or consequential damages occurring in connection with the furnishing, performance, or use of this material. 06/06/2014 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 1 of 6

1. INTRODUCTION This Technical Instruction Document (TID) provides instructions for performing recommended annual maintenance of Benchmark 750 and Benchmark 1000 Boilers. 2. LIST OF TOOLS The following tools are required to perform the instructions in this bulletin. Flat-head screwdriver or 5/16 nut driver Phillips head screwdriver #2 Torque wrench The following wrenches (open-end, box or socket) are used: o 7/16 o 3/4" o 1 3. MAINTENANCE KIT CONTENTS Table 1: Benchmark 750/1000 Annual Maintenance Contents Item Part No. Quantity Description 1 58023 1 IGNITOR-INJECTOR 2 66034 1 FLAME DETECTOR 3 81048 1 FLAME DETECTOR GASKET 4 81092 1 CONDENSATE TRAP ORIFICE GASKET 5 84017 1 CONDENSATE TRAP O-RING 4. INSTALLATION INSTRUCTIONS WARNING Remove electrical power before working on the unit. Adhere to all local codes regarding lock-out, tag-out procedures. WARNING The ignitor-injector and flame detector may be hot, therefore, care must be exercised to avoid burns. It is easier to remove these parts from the unit after the unit has cooled to room temperature. 06/06/2014 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 2 of 6

4.1 Replacing the Ignitor-Injector The instructions below replace the ignitor-injector (p/n 58023). 1. Set the ON/OFF switch on the control panel, to the OFF position. Disconnect AC power from the unit by turning off power at the breaker. 2. Remove the panels from the top and sides of the unit, exposing the intake manifold and air filters. 3. Disconnect the electrical cable from the ignitor-injector. Blower O 2 Sensor Staged Ignition Solenoid Elbow Compression Nut Ignitor-Injector Gasket Burner Plate Figure 1. Ignitor-Injector & Locations 4. Use a 7/16 wrench to disconnect the compression nut securing the igniter-injector s gas injector tube to the elbow of the staged ignition assembly and then disconnect the staged ignition solenoid from the igniter-injector. Elbow Compression Nut O 2 Sensor Ignitor-Injector Figure 2. Ignitor-Injector Disassembly 5. Use a 1" wrench to remove the ignitor-injector from the burner plate and discard it. 06/06/2014 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 3 of 6

6. Install the new ignitor-injector, included with the kit, onto the burner plate. Use zero to three indexing washers, as needed, so that the igniter-injector s gas injector tube is positioned within the 120 angle range shown below. Torque the ignitor-injector to approximately 170-180 in-lbs. DO NOT over tighten. O 2 Sensor Gas Injector Tube Ignitor-Injector 120 Figure 3. Ignitor-Injector Orientation (viewed from above looking down) 7. Connect the igniter-injector s gas injector tube to the elbow of the staged ignition solenoid with the new compression nut, included with the kit. 8. Reconnect the igniter-injector cable. 4.2 Replacing the and Gasket The instructions below replace the flame detector (p/n 66034) and flame detector gasket (p/n 81048). 1. Disconnect the flame detector lead wire. 2. Disconnect the flame detector lead wire and then remove the two (2) #10-32 Phillips head screws securing the flame detector to the burner plate. Gasket Figure 4. Replacement 3. Remove the flame detector and gasket from the burner plate and discard them. 4. Install the new flame detector and flame detector gasket, included with the kit, fastening them with the #10-32 Phillips head screws removed in step 2. 5. Reconnect the flame detector lead wire. 06/06/2014 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 4 of 6

4.3 Replacing the Condensate Trap O-Ring New Style Trap There are two types of condensate traps in service, and older and a newer style. The instructions in this section apply ONLY to the NEWER style condensate trap. For the older-style trap, see section 4.4. These instructions replace the condensate trap O-ring (p/n 84017), located under the condensate trap s cover. The condensate trap is attached to the exhaust manifold s condensate drain pipe. Figure 5. Condensate Trap Location 1. Disconnect the external condensate trap from the exhaust manifold by loosening the thumb screw on the trap inlet. 2. Disconnect the condensate trap outlet from the floor drain. 3. Remove the cover from the condensate trap, secured with four (4) thumbscrews (see Figure 6). 4. Replace the O-ring from under the cover with the new condensate trap O-ring, included with the kit. 5. Remove the float and float guide from the condensate trap. 6. Thoroughly clean the trap and float, and inspect the drain piping for blockage and then reinstall the float and float guide. If the trap cannot be thoroughly cleaned, replace the trap. 7. Reassemble the float and float guide and then secure the cover with the four thumb screws. INLET OUTLET Figure 6 Newer-Style External Condensate Trap Cross Section 8. Reconnect the condensate trap to the outlet piping 9. Reconnect the condensate trap to the exhaust manifold drain by tightening the thumbscrew on the trap inlet. 06/06/2014 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 5 of 6

4.4 Replacing the Condensate Trap O-Ring & Orifice Gasket Old Style Trap The instructions in this section apply ONLY to the OLDER style condensate trap. These instructions replace the condensate trap O-ring (p/n 84017), located under the condensate trap s cover, and the condensate orifice gasket (p/n 81092). The condensate trap is attached to the exhaust manifold s condensate drain pipe (see Figure 5). 1. Disconnect the external condensate trap from the exhaust manifold. 2. Remove the connection on the outlet side of the condensate trap. 3. Remove the cover from the condensate trap, secured with four (4) thumbscrews. Cover Thumb Screws (4) Condensate Trap O-Ring Inlet Float Orifice Gasket Figure 7. Older-Style External Condensate Trap Cross Section 4. Replace the O-ring from under the cover with the new condensate trap O-ring, included with the kit. 5. Remove the float and float guide from the condensate trap and then remove the orifice gasket. 6. Thoroughly clean the trap and float, and inspect the drain piping for blockage. If the trap cannot be thoroughly cleaned, replace the trap. 7. Install the new orifice gasket, included with the kit, and then reinstall the float guide, float, cover and thumb screws. 8. Reconnect the condensate trap to the outlet piping and then reconnect it to the exhaust manifold drain. 4.5 Putting the Unit Back in Service 1. Reconnect AC power to the unit. 2. Set the ON/OFF switch on the control panel to the On position. 3. Check your work prior to reinstalling the panels, including checking that all connections are tight and do not leak. 4. Replace all panels removed during the installation of this kit. Change Log Outlet Date Description Changed By 04/03/2014 Rev B: Changed kit number, removed Air Filter per PIR 1005 Chris Blair 06/06/2014 Rev C: Replaced fuel rod 66020 with 66034 per PIR 1028-3 Chris Blair 06/06/2014 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 6 of 6