ACTIVE FIRE CURTAINS INTISI7

Similar documents
SMART FIRE CURTAINS INTISI7. for invisible fire protection closures

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

PRODUCT SPECIFICATION FireMaster Plus

PRODUCT SPECIFICATION FireMaster Plus Concertina

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

SMOKESTOP evacu8 ACTIVE SMOKE BARRIERS WITH EGRESS LEADING THE WAY IN FIRE PROTECTION

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

CI/SfB (68.5) February Intelligent security and fire protection. SecureFire S e c

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS)

ROLL-DOWN FIRE DOORS AND SMOKE CURTAINS

PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex

ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS

FIRE & SMOKE CURTAINS

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

Operation & Maintenance Manual

Smoke and Fire Curtains. Performance Door sets for security and Fire resistant applications. Northern Doors (UK) Ltd

PRODUCT CATALOGUE ACTIVE FIRE AND SMOKE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

Smoke and Fire Curtains

FIRE & SMOKE CURTAINS

HART XL High Sensitivity Smoke Detection

Schueco Fire and Smoke Protection Systems

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15.

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

The Application of Double-deck Inorganic Composite Fire Resisting Shutters in Constructional Engineering Bai-Xia ZHOU*

Chapter Nursing Homes

SMOKE & FIRE THE LEADING EDGE IN. Smoke & Fire Curtains

FIBERSHIELD EW NEW PRODUCT LOW RADIANT HEAT TRANSFER ( PARTIAL PARTIAL INSULATION ) FIRE CURTAINS. Supported by full scale fire test data

Flexibility right from the start. PAVIRO Public Address and Voice Evacuation System with Professional Sound Quality. boschsecurity.

FIREMASTER CONCERTINA TM

Western Firex. Heat & Smoke Ventilator. EAGLE series Natural Ventilation

Moffitt Firex. Heat & Smoke Ventilator. MoffittCorp.com (800) th Ave S. Suite 130 Jacksonville Beach, FL

HART XL High Sensitivity Smoke Detection

Unit 2 Fire Safety (Zone 1)

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

Model 600 Operation & Maintenance Manual

Your competent partner for measuring and services.

AmpLight Lighting Management System

SIMPLY THE WIDEST FOLDING DOOR. FFT FLEX Green. Maximum clear opening widths and best thermal separation.

PASSIVE FIRE PROTECTION FTI-MARNEROS LTD

ROLLER SHUTTER SOLUTIONS AS UNIQUE AS YOUR VISION. RollUp Serranda (Pty) Limited 0860 ROLLUP ( )

fire protection glass

Iv. 5. FIRE-RESISTANT GLASSES Introduction Pyrobel and Pyrobelite Pyropane 372

Microcontroller based design for Tele-sensing and extinguishing fire

Fire PROtec. Manual for automatic Fire Curtains. copyright by SIMON RWA Systeme GmbH Passau

MAINTENANCE OF ESSENTIAL SAFETY MEASURES EXPLAINED (Building Regulations 2006)

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

fire protection glass

ES 200. Sliding door operator

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

High-Speed Roll Doors An intelligent entrance solution for every location. ASSA ABLOY Entrance Systems

EN CE instead of approval Opportunities for manufacturers and trading to enter new markets in Europe

Corporate Presentation

FIRE DOOR CLOSING SYSTEMS

AUTOMATIC FIREFIGHTING SYSTEMS IN HOSPITALS

SmartStruxure Lite Small Building Systems

DATASHEET VARIOSPEED 6 EMERGENCY RETRACT UNIT CONTROLS AT MOTOR (VS6-ERU-CAM)

Total Connect Box. User manual

Loss Prevention Standards

Significant Changes to the 2012 IFC Semiconductor Fabrication Facilities. Scott Stookey Senior Technical Staff International Code Council, Austin TX

Technical Manual (European Standards)

Tel: +44(0) Fax: +44(0) /17 LGM Products Ltd. Web: ISO 9001:2015 certified

automatic FiReFighTing SYSTeMS in PainT booths

Part 6 Additional class notations Chapter 6 Additional fire protection for passenger vessels

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

FIRE DEPARTMENT - RULES FOR FIRE PROTECTION IN AUSTRIA

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

Smoke Vent Control Panel PCB4 V4 Installation Manual

MAKE YOUR LIFE EASIER WITH NICE AUTOMATING GATEWAYS IS SIMPLE, FAST AND INCREASES SECURITY

+ = FIRE LABORATORY INTRODUCTION. APPLUS+ LGAI - Our company history. High Technology Knowledge. Customer Confidence. Branding

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

Hi, welcome to the topic on Fire Detection and Alarm Systems. This topic forms one of the critical knowledge areas for prospective fire safety

High-precision aspirating smoke detectors for every requirement.

High-precision aspirating smoke detectors for every requirement SecuriRAS ASD 535, ASD 532 and ASD 531 aspirating smoke detectors

NX-10 wireless keypad. To wire or not to wire?

External venetian blinds sunlight included 40% ENERGY SAVINGS WITH INTELLIGENT SUN SHADING

INDUSTRIAL AIR CURTAIN. IndAC 2

Digiplex LED Keypads User s Manual

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

SGG CONTRAFLAM LITE SAINT-GOBAIN GLASS PROTECT

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

FIRE DOOR. AlarmGard & FireGard. Preferred door solutions.

Technology Menu Care Laundry

NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION REQUIREMENTS

Fire protection for rolling stock. Innovative solutions from Siemens Building Technologies. Answers for infrastructure and cities.

Fire resistance. Appendix E. E.1 Fire resistance. Appendix. (A copy of this Appendix is available on /)

Sintony 60 security meets design

Standards in Security Shutters & Fire Shutters (UK & USA)

THE WASH WORLD S NEW EXPERIENCE.

HEUFT SPECTRUM. Modular HEUFT systems of the new generation. Highly automated, self-explanatory and SIMPLY EASY!

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

Technology Menu Hospitality Laundry

BIOMEDICAL FREEZERS ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION

CO SENSOR CARBON MONOXIDE DETECTOR

NOXSYS A SYSTEM FOR THE HIGHEST LEVEL OF SECURITY

Transcription:

ACTIVE FIRE CURTAINS INTISI7 For invisible fire partitions www.intisigroup.com

Fire Engineered Fabrics How can anyone perfect anything? What does engineering require? From which approach we start???? INTISI was founded to become the technological partner of active fire curtains and smoke barriers. By recognizing the importance and convenience of providing architects with the confidence and freedom to design without compromising fire regulations, we became specialized by offering the most innovative fire partition solutions. Our full range of products have been certified by the most demanding certification bodies according to the latest International Quality Standards in strict adherence to ISO 9001 quality management system. Our success is driven by our INNOVATIVE POTENTIAL that enables us to improve ways to safeguard life and property. ENGINEERING FOCUS Invisible Fire Partitions by Means of Active Fire Curtains REQUIREMENT Construction regulations require dividing zones to: Limit the spread of fire and smoke To allow access to protected escape routes without any loss of fire resistance, and to limit smoke entry into these routes. The standard EN 1634-1 regulates fire resistance tests and classifies as an asymmetric enclosure. OBJECTIVE PARTITIONS Create fire partitions under different protection requirements according to EN 13501-2 standard. In order to ensure the integrity against fire on both sides, asymmetrical fire curtains must be tested against fire on the side where its components are located (supporting items, guide rails and motor). Then we begin to craft around our ideas PROVIDE ANSWERS E Integrity Guarantee for containing flames and hot gases on the side exposed to fire. 1100ºC SIMPLIFYING INNOVATING IMPROVING REINVENTING EI Integrity Insulation Guarantee for containing flames and hot gases on the side exposed to fire. Guarantee that heat transfer does not cause a fire on the side not exposed to the flames.* 1100ºC Until everything we create enhances its value * Thermal insulation by means of sprinklers with low pressure closed nozzles and quick response thermal-fuses EW Integrity Guarantee for containing flames and hot gases on the side exposed to fire. PERSONALISED PERIPHERAL SERVICES Reduced heat radiation Limiting of heat radiation transfer, preventing ignition of materials and people damages on the side not exposed to the fire. 1100ºC Technical advice and consultancy Repair of curtains at own Technical Service facilities Development of personalised solutions 2 www.intisigroup.com 3

Active Fire Barrier. Design Operable Fabric Fire Curtain Fire resistant doorset constructed from technical fabrics which functions as a rolling shutter by means of the ISF Gravity Fail Safe system. 1 Chassis 5 3 2 4 Metal chassis with dimensional stability to house the fabric and different system components. Its blunt edge design limits its friction with the fabric to ensuring full integrity and durability of the different components. 2 Ltp24 Motor Block 24V high performance tubular motor block, now more silent and reliable. 1 3 Tubular Shaft With Easy-Fast System Roller that contains the LTP24 motor block and rolls the Intisi tex fabric effectively. 4 Anchoring System With Skatip Design Up to 20 mm thickness, securing mechanism designed to guarantee the integrity of the system even under the direct exposure to fire. 5 Telescopic Roller Bridge A bridge mechanism with telescopic ROLBRID system to support and align large size Intisi fire curtains (WIDE series). 6 Intisi tex TECHNICAL FABRICS Latest generation technical fabrics made from fibreglass reinforced with stainless wire to guarantee integrity at high temperatures. 7 7 Gl Side Guides 6 Tear proof guiding system to guarantee tightness and integrity of the Intisi fire curtain against gases and flames in the event of a fire with low friction inner guiding bar. 8 Sealing Strip A compact angular rigid counterweight mechanism to guarantee the secure operation of the Intisi fire curtain without electrical power by means of ISF Gravity Fails Safe technology at a controlled speed. 8 4 www.intisigroup.com 5

Active Fire Curtains Simplicity is not something simple intisi 7 Active Fire Curtain Performance ISF Gravity Fail Safe Technology Gravity closure at a controlled speed. 1 In case of fire Intelligence All components are conferred with technology to enable fire curtains to solve problems. 2 Heat/smoke detector sends a signal to the Fire Alarm System Ultra Compact The small size of the system means it can be fully integrated in the space. 4 LTP24 Motor release the brake 3 Intisi S103c Control Core transforms this signal Emergency Function Programmed timed emergency retract function. Certified Quality Intisi 7 fire curtains have been tested to the most demanding international standards. 5 Deploying the fire curtain by gravity in a controlled speed Ultra Size The biggest non overlapped fire curtains in the world certified according with EXAP pren 15269-11. Reversible They are the only fire curtains certified to protect 2 fire sectors. 2 4 One Click Assembly The design of each part is ideal for simple assembly and maintenance. 1 3 Anti Crushing Guaranteed controlled speed without any power supplies. 5 Guaranteed Safety All the advantages of Intisi 7 fire curtains are meant to provide complete safety against fire. Fire operational position Emergency Function 6 www.intisigroup.com 7

Active Fire Curtain Performance intisi 7 Active Fire Curtain. Reversible ISF Gravity Fail Safe Technology Ability of the Intisi 7 fire curtain to move to its fire operational position in a safe and controlled manner when all consumable primary and auxiliary power supplies are removed. The LTP24 Motor keeps the fire curtain retracted and controls the deployment speed by means of the powers supplies. In case all the consumable power supplies were removed, the ISF Gravity Fail Safe Technology ensures the deployment of the Intisi 7 fire curtain by gravity in a controlled speed. Fire curtain tested with the supporting elements (headbox and side guides) NON exposed directly to fire. Valid for protecting areas with fire in 1 single fire sector. Suitable for protecting two fire sectors The fire curtains are ASSYMETRIC fire separating elements by nature. The EN 1634-1 standard sets out that to guarantee the fire resistance of a fire curtain, it shall be tested with the supporting elements (headbox and side guides) exposed to the direct attack of fire. Emergency Function 1100ºC Programmed timed emergency retract function: Trapped people could escape Fire service override switch 1 Press the push button to enter or escape Fire curtain tested with the supporting elements (headbox and side guides) exposed directly to fire. Valid for protecting areas with a fire affecting 2 fire sectors. 1100ºC 2 The Intisi 7 fire curtain will retract partially to contain smoke for a predetermined time 3 The Intisi 7 fire curtain will close fully by gravity automatically 8 www.intisigroup.com 9

Approvals Intisi 7 fire curtains prove their high quality and accuracy in many tests, certificates and approvals by accredited official laboratories, in accordance with the European standards. intisi 7 Active Fire Curtain Product Index UNE EN 1634-1 Fire resistant test: specifies a method for determining the fire resistance of the fire curtains as a fire compartimentation element. : define a harmonised procedure for the classification for resistance to fire of fire curtains. EXAP pren 15269-11 Extended application of test results: scale the tested dimensions of the fire curtains during the UNE EN 1634-1 Fire resistant test up to bigger dimensions. UNE EN 14600 Self-closing durability test: requirements and methods of conformity necessary to demonstrate the capability of a fire curtain to cover their designed working life. The fire classification specified in the UNE EN 13501-2 Fire Resistance classification report should comply with the fire classification requested in the project (E120, EW120, EI120). The UNE EN 13501-2 Fire Resistance classification report specifies the exposure conditions during the UNE EN 1634-1 Fire resistant test. To ensure if the fire curtains are capable to resist the direct attack from fire, the structural components (Head box and lateral guides) should be placed on the exposed side to fire during the UNE EN 1634-1 Fire resistant test. intisi 7 E120 Fire Resistance Max. Width Max. Height Test Installation 2 hours fire resistance 22 meters (1) 10 meters (1) Structural components (headbox and side guides) inside the furnace. The UNE EN 13501-2 Fire Resistance classification report specifies the overall dimensions of the fire curtain during the UNE EN 1634-1 Fire resistant test. If the fire curtain should have bigger dimensions, they should be calculated according to EXAP pren 15269-11 Extended application of test results. intisi 7 EW120 Fire Resistance Max. Width Max. Height Test Installation 2 hours fire resistance 15 meters (1) 5,5 meters (1) Structural components (headbox and side guides) inside the furnace. intisi 7 EI120 Fire Resistance Max. Width Max. Height Test Installation 2 hours fire resistance (2) 22 meters (1) 10 meters (1) Structural components (headbox and side guides) inside the furnace. (1) Dimensions in one continuous roller certified as per EXAP pren 15269-11 (2) Intisi-SC Sprinkler System required 10 www.intisigroup.com 11

Active Fire Curtain E120 A change of perspective Big fire-separating elements are technically possible with the Intisi 7 E120 fire curtains. Its advanced components, in compliance to European Standards, provide 120 minutes integrity under EN 1634-1 with only one continuous roller. The Intisi 7 E120 fire curtain has been optimized to can be integrated in small spaces. The technologically advanced fire resistant fiberglass fabric reinforced with stainless steel wire of only 0,65mm thickness; and its compact structural components (headbox, side guides and bottom bar) tested in direct exposure to fire, make it the perfect solution to replace a nonloadbearing wall and open up exciting design possibilities. Fire classification Fire classification Max. Width Max. Height INTEGRITY E120 22 meters (1) 10 meters (1) (1) Dimensions in one continuous roller certified as per EXAP pren 15269-11 Series Light Intisi 7 E120 active fire curtains up to 6 meters width. The roller is fixed in one side. Wide Intisi 7 E120 active fire curtains from 6 meters to 22 meters width. The roller floats on a double roller system. Headbox Range Headbox Headbox Size (PxC) Series LIGHT height (H) Series WIDE height (H) COMPACT 190x200 mm 3 meters - COMPACT 236 x290 mm > 3 10 meters 7 meters COMPACT pro 286x445 mm - > 7 10 meters Optionally available in any RAL color Side Guide Range Side guide Dimensions (GxF) Height (H) Width (A) GL130 130 x 74 mm 6 meters 13 meters Width (A) Height (H) Width (A) Height (H) GL175 175 x 105 mm > 6 10 meters 22 meters 6 meters 10 meters > 6 22 meters 10 meters Optionally available in any RAL color 12 www.intisigroup.com 13

Active Fire Curtain EW120 Innovation and precision Intisi 7 EW120 reaches a new level of innovation and precision. Its entire design offers a limited heat radiation zone. The Intisi 7 EW120 fire curtain remain invisibly retracted until its activation, at which time they close safely to their fire operational position. Its technologically advanced fire resistant fabric of 2mm thickness, when exposed to high temperatures, creates an internal insulating layer, providing a thermal insulation barrier during 120 minutes. Series Light Intisi 7 EW120 active fire curtains up to 6 meters width. The roller is fixed in one side. The complex structure of the tex-ew120 fabric consists of multi-layer fabric finished with aluminum foil in both sides, in conjunction with the compact structural components (headbox, side guides and bottom bar), tested in direct exposure to fire, minimizes the heat transmission to under 15 kw/m 2 for over 2 hours, while, at the same time, limits the passage of flames and gases to the other side. Wide Intisi 7 EW120 active fire curtains from 6 meters to 15 meters width. The roller floats on a double roller system. Fire classification Fire classification Max. Width Max. Height INTEGRITY and REDUCED HEAT RADIATION EW120 Headbox Range Headbox Headbox Size (PxC) Series LIGHT height (H) Series WIDE height (H) COMPACT 190x200 mm 1,8 meters - COMPACT 236 x290 mm > 1,8 5 meters 4 meters COMPACT pro 286x445 mm - > 4 5,5 meters Optionally available in any RAL color Side Guide Range 15 meters (1) 5,5 meters (1) (1) Dimensions in one continuous roller certified as per EXAP pren 15269-11 Side guide Dimensions (GxF) Height (H) Width (A) GL130 130 x 74 mm 4 meters 15 meters Width (A) Height (H) Width (A) Height (H) GL175 175 x 105 mm > 4-5,5 meters 15 meters 6 meters 5,5 meters > 6 15 meters 5,5 meters Optionally available in any RAL color 14 www.intisigroup.com 15

Active Fire Curtain EI120 Advanced Technology Fire classification Intisi 7 EI120 dramatically improves the performance of the active fire curtains. It provides the first smart fire invisible partition. The Intisi 7 EI120 active fire curtain is compliant to European Standards, offering 120 minutes integrity and insulation under EN 1634-1 in conjunction with Intisi-SC sprinkler system. The Intisi 7 EI120 fire curtain uses the same technical fire resistant fiberglass fabric, reinforced with stainless steel wire, used on the Intisi 7 E120. The Intisi-SC sprinkler system cools the fabric of the curtain thus reducing, in case of fire, the temperature on the safe side of the curtain. Fire classification Max. Width Max. Height INTEGRITY and INSULATION EI120 22 meters (1) 10 meters (1) (1) Dimensions in one continuous roller certified as per EXAP pren 15269-11 Series Light Intisi 7 EI120 active fire curtains up to 6 meters width. The roller is fixed in one side. Width (A) Height (H) Width (A) Wide Intisi 7 EI120 active fire curtains from 6 meters to 15 meters width. The roller floats on a double roller system. Height (H) Headbox Range Headbox Headbox Size (PxC) Series LIGHT height (H) Series WIDE height (H) COMPACT 190x200 mm 3 meters - COMPACT 236 x290 mm > 3 10 meters 7 meters COMPACT pro 286x445 mm - > 7 10 meters Optionally available in any RAL color Side Guide Range Side guide Dimensions (GxF) Height (H) Width (A) GL130 130 x 74 mm 6 meters 13 meters GL175 175 x 105 mm > 6 10 meters 22 meters Intisi-SC Sprinkler System The only certified closed nozzle system K80 sprinkler with quick response bulb type thermal fuse Sprinkler fitted every two linear meter of the width of the Intisi 7 EI120 1.1 bar working pressure Sprinkler only requested to cool the fabric (not for cooling the structural components: headbox and side guides) First hidden sprinkler system above the false ceiling 6 meters 10 meters > 6 22 meters 10 meters Optionally available in any RAL color 16 www.intisigroup.com 17

Smart Control Core S103c Controlled Safety Features Operability. Makes the closure function of Intisi 7 fire curtains effective, in a controlled speed. Personalised programming. The advanced processor permits a large number of programming parameters to be stored. Intelligence. Enables Intisi 7 fire curtains to resolve problems autonomously through its permanent status of self-test. Memory. Up to 255 fault and event log. Communication. Users are provided information about the system status in real time, via WIFI, TCP-IP, GSM, etc. Safety. Permits evacuation of people found in the area of the fire and action by the firefighter. Specifications Advanced i3 processor, designed with 32 bit architecture. Remote connectivity to advanced applications (WIFI, TCP-IP, GSM, etc). Pulse width modulation technique PWM. Adjustable descent speed. Hall effect encoder, providing over 6000 information bits per minute. 24V back-up UPS device with automatic monitoring and charging of its battery pack. Can be connected to BMS for monitoring the system. 230V AC / 50 Hz power supply. Dimensions: 315 x 320 x 85 mm. Low power consumption. Programmable timed emergency retract. Multi-purpose. Fitted with an area to connect fire detection devices. Programming The advanced technology featured in the SI03c Smart Core Control permits personalised programming to adapt to the requirements of each client. The Intisi SI03c smart control core governs the Intisi 7 fire curtains efficiently and effectively. Flash Basic programming is permitted directly from the Core Control. Programmable timmed emegency retract. Multi-positional deployment programming to provide initial smoke containment prior to full fire containment. Advanced programming may be carried out through the Intisoft application. Max. 32 heat/smoke detectors Siren Alarm INTISOFT Permits remote monitoring of events log and status (in real time) for the Intisi 7 active fire curtains Emergency Function Wifi Intisi 7 Fire Alarm System BSM (Building Management System) GSM TCP-IP 18 www.intisigroup.com 19

Installation intisi 7 Maintenance Ensuring that your Intisi 7 active fire curtain remains operationally is not only important in order to comply with fire codes and insurance requirements, but also is critical for guarantee that your building remains protected from the effects of fire. One Click Assembly Electronic Final Opening Adjustment Tear-free Design Event Log The effectiveness of the Intisi 7 active fire barrier assembly is ensured by a proper installation; for this reason, the Intisi 7 components and installation procedures are designed under the premise of ONE CLICK ASSEMBLY. This enables error-free installation and minimize the installation time. Safe Assembly The Intisi s great experience provides us with the knowledge to design each single part under the premise of SAFE ASSEMBLY. The Intisi 7 active fire curtain final opening adjustment is carried out electrically by means of the Intisi SI03c control core. Adaptable The Intisi 7 active fire curtains adapt completely to the building special features, providing customized solutions to satisfy the building safety needs (f.e. Intisi SI03c control core can be installed at 50 meters from the Intisi 7 active fire curtain). The active fire curtains main distinguishing factor is the fabric. The fabric main benefits are: flexibility, low weight, reduced thickness and wide range of technological alternatives. But its main weakness is its fragility against friction in contact with the structural components, thus tearing the fabric damaging the system. To deal with this weakness, the Intisi 7 active fire curtains design minimized the fabric risk of tear. The Intisi SI03c control core is in permanent status of self-test. This fault and event logs are stored in the memory of control core which can host 255 events. The event log provides with relevant information which allows to minimize the corrective maintenance tasks and also facilitate the preventive maintenance task, thus optimizing the preservation of the system. INTISOFT Software for commissioning the installation and for maintaining the Intisi 7 active fire curtain. 20 www.intisigroup.com 21

Role and Use Role To maintain any compartimentation of building needed to limit the spread of fire and smoke. To allow access to protected escape routes, and to limit smoke entry into these routes. As a method of upgrading non-fire resisting elements where required for compartimentation or protecting means of escape. To create safety areas near combustibles. To optimize automatic suppression system. Most Common Applications Doorways Airports Windows Stadiums Theatres Stairs and escalators Atrium Shop fronts Corridors Serving hatches Tunnels Electrical substations Basement car parks Lifts Rooflight domes or skylights We adapt our solutions to your needs Logistics Sector Logistics centres are buildings that are carefully designed to optimise the logistics activity with maximum use of space. Industrial Sector Industrial activities require high levels of safety and protection with maximum optimisation of space. Petro-Chemical Sector Petro-chemical plants require a culture of preventive safety for the risks involved in their own activity. Nuclear Power Plants Nuclear power plants involve high specific risks which need to be controlled and foreseen. Food And Agriculture Sector The food and agriculture industry must ensure the healthiness, hygiene and freshness of the products, and provide a safe environment for employees and animals. Malls And Buildings Non-industrial establishments are pioneers in new construction rends, constantly facing new architectural challenges. Cultural Establishments Theatres and concert halls are public establishments, that could involve the use of equipment and activities that can be hazardous to people and pose a threat to the integrity of the building. Area affected by fire Safe areas 22 www.intisigroup.com 23

Calle Industria, 30D P.I. La Bóbila 08320 El Masnou (Barcelona Spain) (34) 935 401 913 intisi@intisigroup.com www.intisigroup.com INTISI7-EN05-03/2018