USER MANUAL MINITRACER PORTABLE SNIFFER

Similar documents
NEW Restek Electronic Leak Detector

Restek s Electronic Leak Detector

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

EST User Manual. (Please read this manual carefully before using)

Refrigerant Leak Detector

RLD-H10P Refrigerant Leak Detector

INSTRUCTION MANUAL FOR RIKEN PORTABLE TOXIC GAS MONITOR

GAS-Mate. Combustible Gas Leak Detector

III. 99 Washington Street Melrose, MA Phone Toll Free Visit us at OPERATING INSTRUCTIONS

NGD8800 USER S MANUAL

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

Contents. FX-1 Operations Manual Micro Air Corporation 124 Route 526 Allentown, NJ 08501

Analog Room Pressure Monitor RPC Series

Safe Operation Manual. Honeywell IQ Force Gas Detector

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

RLD-H10G Refrigerant Leak Detectors

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

Instruction Manual Model GX-86 Portable Four Gas Monitor

D3000. Installation & Setup Guide

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

NexSysLink. 2 CAN Display Operation Manual. CAN Instruments Product Family

Portable Oxygen Monitor OX-07. (Type A) Operating Manual

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

ZSC100 Gas Detection and Alarm System Controller

IMR IX176 Portable Gas Detector User Manual

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

Instruction Manual Model GX-82 Portable Three Gas Monitor

99 Washington Street Melrose, MA Phone Toll Free Visit us at

INSTRUCTION MANUAL MODEL GX-82A

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

LD-5000 REFRIGERANT LEAK DETECTOR

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

Portable type of Carbon Dioxide Detector Model: GT220

Model 850 Investigator s Aid Accelerant and Gas Detector Operation and Maintenance

User Manual SF6 GASCHECK 6000

DYGIZONE GJD910 Lighting Controller & Enunciator

MODEL OX-07 Type A INSTRUCTION MANUAL FOR RIKEN PORTABLE OXYGEN MONITOR PT0E-0860

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

SENSIT HXG-2d Combustible Gas Detector

SF 6 -Leak Pointer Operating Manual (original version) Type-No.: R002

REFRIGERANT LEAK DETECTOR

Pioneer-R16 Gas Monitor Operator s Manual

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

Aqua-Air Tempwise 2001 Chillwater Digital Thermostat. Operating Manual. Aqua-Air Manufacturing division of the James D. Nall Co., Inc.

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

Using the QRAE Plus personal multigas monitor

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

CS150 OWNER S MANUAL DISCRIMINATOR METAL DETECTOR

Sensistor ISH2000 Hydrogen Leak Detector

BX444-Mc Gas Detector

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

ALTAIR 5X Multigas Detector Product Specification

Q: What can be done if my dishes have a cloudy, white film on them after a wash?

Operate the Mutli-Gas Monitor PID

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

E1000 Portable gas detector

Instruction Manual Eagle Series

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

4L & PRO PROVIDER MATERIALS

D-TEK Select. Refrigerant Leak Detector

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

NetworX NX-8V2. LED Keypad User Manual

HILLS Series LED Code Pad User Manual

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

testo 316-EX gas leak detector Instruction manual

TIF9055 Programmable. Owner s Manual Manual del Propietario Manuel du propriétaire Benutzerhandbuch Manuale del proprietario

THERMAX Efficiency Monitor

GS100M Gas Detector. Technical Specification

Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS

Warranty Registration

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

A3G Green Rotary Laser SPECIAL EDITION INSTRUCTION MANUAL

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

Installation, Operating and Maintenance Manual

VICTORIAN RESPIRATORY SUPPORT SERVICE AUSTIN HEALTH

Smoke Alarm User s Manual

KFP-CF Series Operation Manual

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

OWNER S GUIDE TYPE A TYPE C TYPE B TYPE E TYPE F TYPE D COOL FAN OFF. CA Series << FAN SPEED COOL FAN AUTO SLEEP TIMER FAN SPEED

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

Leak-Seeker I Refrigerant Leak Detector

User Manual. Humidity-Temperature Chart Recorder. Model RH520

New Power Vented Rheem FVIR Tanks

Ammonia Leak Detector Manual

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

Operation Manual. Rev. E GEM-MRI. Oxygen Sampling System.

IPhone: 219/

Transcription:

USER MANUAL MINITRACER PORTABLE SNIFFER

CONTACT US PHONE/FAX Phone: 801.486.1015 Fax: 801.486.1032 ADDRESS FLUIDX Equipment, Inc. 139 W. 2260 S. Salt Lake City, UT 84115 www.fluidxinc.com SMT-07-1006 Rev C ii

CONTENTS 1. SCOPE... 1 2. OVERVIEW... 1 3. SPECIFICATIONS... 2 4. BASIC OPERATION... 3 5. LEAK TESTING... 4 6. INSTRUMENT SETTING DESCRIPTIONS... 6 7. NAVIGATING THE MENU... 7 8. SAMPLE PROCEDURE... 8 9. CHARGING THE BATTERY... 9 10. SENSITIVITY... 9 11. TROUBLESHOOTING... 10 iii

1. SCOPE 2. OVERVIEW This manual contains operation, maintenance, and troubleshooting information for minitracer portable sniffer leak detector. Our leak detectors are designed to ensure safety when used properly. It is the responsibility of the user to follow safety-related warnings, cautions, notes, and other requirements described in this manual. The minitracer is a sensitive, precise leak detector designed for simple operation and exact identification of system leaks in lab and industrial applications. Utilizing thermal conductivity to pinpoint gas leaks from pressurized systems, the highly-sensitive minitracer offers precise detection of gas leaks from pressurized systems. 2.1 PRODUCT INCLUSIONS 6 power cord 3 ½ sampling probe A thermistor-type thermal conductivity detector (TCD) Vibrator-type pump Printed circ uit board 2.2 FEATURES Dual power source (operates on either 120 volts, 60 Hz, or on a single internal rechargeable Ni-Cd battery) An audible tone generator that allows leak testing without visually scanning the meter. HI/LO sensitivity settings Soap- and solution-free detection 1

3. SPECIFICATIONS Table1: minitracer Specifications COMPONENT DETECTOR FEATURES PUMP LINE VOLTAGE VISUAL READOUT BATTERY BATTERY LIFE RANGES ZERO AUDIO SIGNAL DIMENSIONS WEIGHT ACCESSORIES OPERATING TEMP. RANGE DESCRIPTION Thermal Conductivity Cell Low battery alarm Very low battery shutdown Flash memory for saving settings Microprocessor-controlled Diaphragm type Model LHHLD-1000: 115 V, 60 Hz LED bar graph featuring adjustable brightness peak hold with settable duration Rechargeable Ni-Cd 3.6 V/800 mah 7-8 hours Low: x1 High: x100 Adjustable span per range Manual with drift elimination Audible alarm with adjustable set point and volume 3.25 W x 1.81 H x 5.25 L (20.955 x 4.5974 x 13.335 cm) Instrument: 1.05 lbs (476 grams) Carrying Case 70 F +/- 20 F (21 C +/- 11) C CAUTION The minitracer Leak Detector is designed to determine low level leaks of any gas having a different thermal conductivity than air and must not be used to determine leaks of combustible gases. 2

4. BASIC OPERATION 4.1 FRONT DISPLAY PANELS AND CONTROLS Figure 3-1. Front Panel Display and Controls Polarity Indicator Power Indicator Dual Function LED Display Zero Button Power Switch Range Switch Table 2: minitracer Display Panels and Controls CONTROL POLARITY INDICATOR POWER INDICATOR POWER SWITCH RANGE SWITCH ZERO BUTTON DUAL-FUNCTION LED DISPLAY DESCRIPTION LED is ON in the presence of air or any noncorrosive gas with relative thermal conductivity greater than 1.00 (air). LED is OFF in the presence of any noncorrosive gas with a relative thermal conductivity less than 1.00 (air). Illuminates when minitracer is READY to locate leaks. Flashes ON and OFF when internal battery requires charging. OFF/ON switches from standby to normal operating mode. LO/HI Sensitivity. Use LO for locating larger gas leaks and HI position for locating lower level gas leaks. Use Cursor Direction Dictator within programming mode Initiates ZERO function. Adjusts measurement baseline for current environmental operation conditions. Use to enter programming mode, save programmed settings, exit, and move programming cursor. Refer to Section 6.0. Leak detection indicator and instrument programming/ status indication. 3

4.2 BACK PANEL Figure 3-2. Back Panel Sample Probe Inlet Reference Inlet Power Adaptor Connector 4.3 OPERATING THE MINITRACER 1. Switch power ON (power indicator will be illuminated). 2. Allow instrument to stabilize. Longer stabilization periods may be needed depending upon operating conditions or environment. 3. Select the range (LO or HI) appropriate for the target gas. 4. While holding the measurement probe, set instrument ZERO level by pressing the panel button until a single beep is heard. The instrument is now ready to locate leaks. 5. Move the probe slowly toward the target area. Take care not to exhale on or near the measurement probe or instrument itself. If working in HI range it may be necessary to isolate your hand from the probe by use of a nonpermeable glove. 6. Monitor the instrument front panel. When a gas is detected relative to the ZERO level, the LED display will show an increasing number of indicators. 5. LEAK TESTING 5.1 BEFORE YOU BEGIN Before checking for leaks, note the following: CAUTION CAUTION Extreme caution must be exercised when the probe is operating near electrical heaters, switches, and other electrical devices. Avoid exhaling near the probe or instrument housing. The carbon dioxide (CO2) exhaled can be drawn into the probe or REF (reference) chamber of the leak detector, causing a deflection of the LEDs. 4

CAUTION When checking for leaks, it is imperative that fittings or suspected leak areas are dry. If the area has previously been checked with a water-based bubble-type solution and has not been dried, low readings (as well as possible detector contamination) will occur. The thermal conductivity of water vapor will counteract the signal from helium leaks. The resulting effect will be relatively no LED or audio signal output. CAUTION NOTE Do not allow moisture to be drawn into the probe! If helium (He) is being checked, a leak will cause the LEDs to illuminate to the right with the Polarity Indicator in the ON position, while most other gases or vapors will deflect the LEDs to the right with the Polarity Indicator in the OFF position. 5.2 CHECKING FOR LEAKS Using the probe, carefully move the tip around and over suspected joints, seals, seams or other areas where leaks occur. The probe must be moved slowly to detect small leaks. The net effect will be no, or low display readings. 5.3 FINDING LEAKS A leak is indicated if deflection of the LEDs is seen or an audible signal is heard. Remove the probe form the area, allow the LED indicators to reset to zero (manually reset to zero if necessary), and return probe to the suspected location to verify the leak. For more detailed information on leak detector sensitivity, refer to Section10. SENSITIVITY. 5

6. INSTRUMENT SETTING DESCRIPTIONS 6.1 FACTORY DEFAULT INSTRUMENT SETTINGS Table 3: Instrument Settings LED# SETTING RANGE DESCRIPTION LED 1 20 1-20 (20=maximum) Alarm SET POINT LED 2 1 1 (1=minimum) LED PEAK HOLD DELAY LED 3 6 1-6 (6=brightest) LED Brightness LED 4 3 1-7 (7=loudest) Buzzer volume LED 5 1 1-20 (20=least sensitive) LO range sensitivity LED 6 10 1-20 (1=most sensitive) HI range sensitivity LED 7 2 1-4 (4=SOUND AFTER FULL range) LED 8 20 1-20 (1=LEAST averaging) LED 9 11 1-20 (20=highest elimination) Alarm mode TC filter/average Drift elimination, LED 11 15 1-20 (1=slowest) Motor speed LED 19 9 9 (Latest revision=9) Software Ref., LED 2 Table 4: LED Control Descriptions LED# ALARM SET POINT (LED#1) PEAK HOLD DELAY (LED#2) LED BRIGHTNESS (LED#3) BUZZER VOLUME (LED#4) LO RANGE SENSITIVITY (LED#5) HI RANGE SENSITIVITY (LED#6) DESCRIPTION Sets the LED that will trip the alarm. Sets the number of seconds for the peak hold. (The LED number is equal to the number of HOLD seconds, i.e., an LED setting of 3 will set the hold at three seconds.) Sets the LED brightness. Brightness changes in relation to the LED number, i.e., he lower the LED setting, the greater the brightness. The higher the LED setting, the less bright the LED becomes. Sets the buzzer volume. Volume changes in relation to the LED setting., i.e., the higher the LED setting, the louder the buzzer becomes. The lower the LED setting, the quieter the buzzer becomes. Sensitivity changes in relation to the LED number, i.e., the lower the LED setting, the more sensitive the instrument becomes. The higher the setting, the less sensitive the leak detector becomes. Sensitivity changes in relation to the LED setting, i.e., the lower the LED number setting, the more sensitive the instrument becomes. The higher the setting, the less sensitive the leak detector becomes. 6

LED# ALARM MODE (LED#7) TIME CONSTANT / AVERAGE (LED#8) DRIFT ELIMINATION (LED#9) PUMP SPEED (LED#11) SOFTWARE REVISION (LED #19) DESCRIPTION Sets the alarm mode. 1=OFF 2=On (Audio only) 3=N/A 4=N/A Sets the number of measurement samples averaged before a reading is displayed. The higher the setting, the more measurement samples are averaged. Acts as a SLOW AUTO ZERO. It is only active when more than 3 LEDs are on. The higher the LED setting, the faster the SLOW AUTO ZERO reacts. At the lowest setting, the fastest SLOW AUTO ZERO reaction is 90 seconds. At the highest setting, the fastest it will react is 14 seconds. The higher the LED setting, the faster the pump motor runs and is an adjustment of flow through the instrument. Indicates the current software revision. 7. NAVIGATING THE MENU 7.1 ENTER PROGRAM MODE Press and hold the Zero button until you hear a double beep (approximately 6 seconds). The first LED will be illuminated signifying the first category. 7.2 CHANGE A CATEGORY To move to a higher category, place the Range switch in the HI position and momentarily press the Zero button. The next higher LED will illuminate. To move to a lower category, place the Range switch in the LO range and press the Zero button. The next lower LED will illuminate. 7.3 ENTER A CATEGORY Press and hold the Zero button until you hear a second beep (approximately three seconds). The current setting for that particular category will be displayed on the LED bar graph. 7

7.4 CHANGE THE VALUE OF A CATEGORY To move to a higher value, place the Range switch in the HI position and momentarily press the Zero button. The next higher LED will illuminate. To move to a lower value, place the Range switch in the LO position and momentarily press the Zero button. The next lower LED will illuminate. You may now save the value to memory or exit without saving. If you exit without saving, the new value will remain in use until the unit is powered off. The next time the power is turned on, the old value will be used. 7.5 SAVE THE VALUE TO MEMORY Press and hold the Zero button until you hear a second beep (approximately three seconds). The new value for that category will be saved to flash. The category will be exited and the category number will be displayed on the LED bar graph. You may now change to a different category or exit the Program Mode. 7.6 EXIT PROGRAM MODE Press and hold the Zero button until you hear a double beep (approximately six seconds). The power indicator will illuminate, the instrument is now ready to normal operation. 8. SAMPLE PROCEDURE 8.1 CHANGING THE ALARM MODE 1. ENTER PROGRAM MODES Press and hold the Zero button until you hear the double beep (approximately six seconds), and then release. The instrument is now in Program Mode and the first category LED will be illuminated. 2. CHANGE THE CATEGORY With the Range switch to the right, momentarily press the Zero button until the 6th LED illuminates (Alarm Mode Category). 3. ENTER CATEGORIES Press and hold the Zero button until you hear the second beep (approximately three seconds) and then release. The instrument has entered the Alarm Mode category. The current setting of the Alarm Mode will now be displayed on the LEDs (ON = LED 2). 4. CHANGE SETTING OF THE CATEGORY 8

Put the Range switch to the left to go down in value when pressing the Zero button. Momentarily press the Zero button to change the setting to the first LED. The Alarm Mode is now OFF. 5. SAVE TO MEMORY AND EXIT CATEGORY Press and hold the Zero button until you hear the second beep (approximately three seconds) and then release. The new value has been saved to flash and you have exited the Alarm Mode category. The instrument is still in Program Mode and the category 6 LED will be lit. You can now go to another category and enter it or you can exit Program Mode. 6. EXIT PROGRAM MODE Press and hold the Zero button until you hear the double beep (approximately six seconds) and then release. You are now out of Program Mode and the leak detector will be under normal operation. 9. CHARGING THE BATTERY 10. SENSITIVITY The minitracer operates off an internal battery. When the battery is discharged, the Power Indicator will begin flashing. The instrument may continue to run when the light is flashing. However, the unit will shut down automatically when the battery is discharged to a point that it will no longer operate correctly. When using the supplied +9 Volt AC adaptor, the instrument will operate and slowly recharge the battery. To fully charge the battery, switch the instrument power OFF and allow to charge for approximately six to seven hours. Before a definition of sensitivity can be resolved, it is necessary to consider the various parameters involved. Sensitivity of an instrument is associated with its ability to detect gaseous mixtures from a filled system maintained at constant concentration. The leak detector is capable of detecting leaks as small as 10-5 atm cc/ sec. Detecting a leak of this magnitude requires a skilled operator. In many applications, the escape rate is so low that the sample drawn into the detector is diluted if the sample rate is too high. Consider the case of a filled system with definitive volume. Here, if the sample is removed from the volume, it must be replaced if pressure is to remain the same. A tank filled with helium-air will change in concentration if a sample is withdrawn at a constant pressure. If a leak from a gas-filled system into the atmosphere occurs at ambient temperatures and pressures, it is extremely important it be detected as close to the leak point as possible. The escape rate, if lower than the sampling rate, will be reflected by a deflection of the indicating device, 9

followed by a reverse deflection as dilution occurs. In the case of such a leak, the sample drawn through the probe and the rate of flow in the tube must be considered. The sampling rate must be low enough so dilution will be negligible, yet high enough to insure reasonable speed of response. The probe is moved slowly around the suspected area and covers all possible sources of leaks and the display or indicator is carefully observed during the entire time, it is possible to locate very minute leaks. The location of the display s indicator is not important. A leak is usually noted by deflection of the indicator. The indication will be to the right with the polarity indicator being ON or OFF depending on the gas located. The suspect area should be reprobed after a short time to insure a leak was picked up and not some extraneous effect. The indication of leaks requires careful probing and rechecking of the area when indications are noted. Table 5: Gas Sensitivity MINIMUM LEAK RATE REQUIRED TO PRODUCE 10% DEFLECTION OF FULL SCALE. Helium (He) 1.0 x 10-5 cc/sec 0.012 cu ft/yr Argon (Ar) 1.0 x 10-4 cc/sec 0.012 cu ft/yr Carbon Dioxide (CO2) 1.0 x 10-4 cc/sec 0.012 cu ft/yr Refrigerant 1.0 x 10-4 cc/sec 0.012 cu ft/yr 40% H2, 60% He (fuel mixture) 1.0 x 10-5 cc/sec 0.012 cu ft/yr 11. TROUBLE- SHOOTING 11.1 INSTRUMENT WILL NOT ZERO 1. Check for clogged probe or obstructed reference inlet. 2. Check instrument settings. Reset to factory defaults if necessary. 11.2 RESPONSE TIME HAS INCREASED 1. Diaphragm on pump is leaking. Replace diaphragm. 2. Sample line (probe) has become punctured. Replace probe assembly. 3. Sensitivity has decreased 4. Sample line (probe) has been punctured. Replace probe assembly. 5. Probe assembly leaking. Replace probe assembly. 6. Pump operating improperly. Replace pump. 7. Check instrument settings. Reset to factory defaults if necessary. 10

11.3 REPAIR SERVICE If repair service is needed, the instrument should be returned to the factory for repair. Before returning the instrument, contact our repair department to obtain a Return Material Authorization number (RMA) and a Health and Safety Declaration form. Instruments returned without these items will not be allowed to enter our facilities. 11