Baxi Bermuda Inset 3 Super

Similar documents
Baxi Bermuda Inset 3 Super

Baxi Bermuda GF3/LFE5 Super

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Baxi Brazilia F 5, F 5S, F 8S & Comfort Stat F 8ST Oak

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Baxi Maxflow Combi FS

Baxi Maxflow Combi WM

Baxi Bermuda Inset 3 Super

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

GB IE. VALOR BOLERO (MODEL BR626) Inset Decorative Fuel Effect Gas Fires. For

Osprey 2 CFL

ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE

OWNER GUIDE. Model 750. INSET LIVE FUEL EFFECT GAS FIRE Fitted with Harmony, Avignon or Style fascia. (GC No )

OWNER GUIDE. Model 739 OPEN DECORATIVE GAS FIRE. (GC No )

Model BR660VA Heat Engine

INSET LIVE FUEL EFFECT GAS FIRE

morsø PANTHER GAS STOVE

Emberglow COAL EFFECT BALANCED FLUE GAS FIRE

Sonnet Plus Anthem Genesis Soraya

Sonnet Plus Anthem Genesis Soraya

OWNER GUIDE. Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia

Model 341 Black Beauty Slimline

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

OWNER S GUIDE MODEL BR417 VA

Baxi Brazilia F5, F5S & F8S

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

GrateGlow THE ALL NEW CAPITAL COLLECTION. G20 at 20mbar convertible to G31 at 37mbar. For use in GB and le. Users Instructions

OWNER S GUIDE ETERNITY. MODEL 540C (GC No ) INSET BALANCED FLUE GAS FIRE

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

Combi Eco Elite Range. User s Guide and Important Warranty Information

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe.

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

Kalahari DECORATIVE FUEL EFFECT GAS FIRE

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier.

Kalahari RC & Camber RC

Model 741FS. Dream, Heritage or Opulent OWNER GUIDE. INSTALLER: Please leave this guide with the owner Baxi Heating U.K. Limited 2007.

User Guide. Promax SL Condensing Central Heating Boiler

MODEL 466 Radiant / Convector Gas Fire Black Beauty

OWNER GUIDE. Sunfire II Radiant. Radiant / Convector Gas Fire. Model 347 (G. C. Number )

Model 347 BLACK BEAUTY

Model 956 OWNER GUIDE. This guide to be left with the owner INSET LIVE FUEL EFFECT GAS FIRE

Fitting & Commissioning Instructions. EcoBlue Combi and System Range. Outdoor Sensor Kit. Kit Part No (System) Kit Part No.

Baxi Bermuda SP3/VP3. Fireside Gas Central Heating Unit Comp N o Iss 7-5/00. Installation and Servicing Instructions

INSTALLATION INSTRUCTIONS COMPACT GAS STOVE MODEL NUMBER 550

MODEL 326 Radiant / Convector Gas Fire Sun~Fire

OWNER GUIDE MODEL BR622 (GC ) INSET LIVE FUEL EFFECT GAS FIRE INCORPORATING. WITH ADORN, VISAGE, ELEGANT or ICON Front

Please leave these instructions with the user. Baxi Bermuda SL3. Fireside Gas Central Heating Unit. Installation and Servicing Instructions

Baxi Wentworth Classic Baxi Kingston 2 Classic

Mesina Fires GLASS FRONT VENTED Model No. M 70

THIS PRODUCT IS APPROVED TO THE EUROPEAN GAS APPLIANCE DIRECTIVE

Baxi Brazilia F 5, F 5S, F 8S & Comfortstat 2 F 8ST

Squirrel - Gas Stoves

Baxi Wentworth Deluxe Baxi Kingston 2 Deluxe

Baxi Bermuda SL3. Fireside Gas Central Heating Unit Comp No Issue 4 1/00. Installation and Servicing Instructions

Baxi Bermuda SP3/VP3. Installation and Servicing Instructions. Fireside Gas Central Heating Unit SP3 VP3

INSTALLER AND OWNER GUIDE

HUNTER HAWK 4 MKII GAS STOVE

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

Please leave these instructions with the user. Baxi Bermuda RG 3. Fireside Gas Central Heating Unit. Installation and Servicing Instructions

Multifit. Installation & Commissioning Instructions

MULTIPOINT BF Gas Fired Balanced Flue Water Heater

User Guide. Platinum Combi Gas Fired Wall Mounted Condensing Combination Boiler

USER GUIDE LOGIC HEAT H

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

User Guide. Duo-tec Combi LPG. Gas Fired Wall Mounted Condensing Combination Boiler

(manual control) (ezi-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE V1/100/B INSTALLATION & USER INSTRUCTIONS

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

USER GUIDE VOGUE MAX SYSTEM

Baxi Ebony Super Gas Fire Comp N o Issue 4 10/99

Baxi Brazilia F 5, F 5S, F 8S & Comfort Stat F 8ST Oak

5traxo INSTALLATION AND SERVICING INSTRUCTIONS MANDATORY REQUIREMENTS INSTALLATION

USERS GUIDE 24, 30. For installation guide see reverse of book

Dovre 250 Cast Iron Gas Stove

User s Operation Instructions & Important Warranty Information

User s Operation Instructions & Important Warranty Information. High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

Decorative Fuel Effect Appliances

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

INSTALLATION & USER INSTRUCTIONS INSET DECORATIVE GAS FIRE

User Guide. Main Eco Elite Combi Condensing Central Heating Boiler

User Guide. EcoBlue Advance Heat Gas Fired Wall Mounted Condensing Boiler

Contact Details. Please note that some of the contact details on this PDF document may not be current.

IMPERIAL FIRES CAST 1 / 2 INSTRUCTIONS IMPERIAL FIRES LTD. SAXON BUSINESS PARK HANBURY ROAD STOKE PRIOR BROMSGROVE B60 4AD

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

Mikrofill Ethos Condensing combination boiler

CLASSIC II QUATTRO DECORATIVE FUEL EFFECT APPLIANCES FOR USE WITH NATURAL GAS IIN INSTALLATION, SERVICING & USER INSTRUCTIONS

AquaNova. Water heater. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Format System 25 HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

User's Instructions. Alpha CB50

Imperial Electric Fires

STRATA BATTERY IGNITION RADIANT CONVECTOR GAS FIRE

Stockton 5. Conventional Flue Coal Effect Stove. With upgradeable control valve. Instructions for Use, Installation and Servicing

WL manual -1.indd 1 13/10/ :19:11

WARMCAIR. Condensing Air & Water Heater. High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS

Huntingdon 30. Conventional Flue Coal Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation and Servicing

Transcription:

Baxi Bermuda Inset 3 Super Fireside Gas Central Heating Units Please keep these instructions safe. Should you move house, please hand them over to the next occupier. User s Operating Instructions KS Super FS Super

Natural Gas Baxi Bermuda Inset 3 KS Super G.C.No. 37 075 54 Baxi Bermuda Inset 3 FS Super G.C.No. 37 075 55 For use with the following boiler: Baxi Bermuda Inset 3 Boiler 50/6 G.C.No. 44 075 08 Codes of Practice, most recent version should be used In GB the following Codes of Practice apply: Standard Scope BS 6891 Gas Installation. BS 5440 Part 1 Flues. BS 5440 Part 2 Ventilation. BS 5871 Part 2 Installation of inset live fuel effect fires. In IE the following Codes of Practice apply: Standard Scope I.S. 813 Domestic Gas Installations. IMPORTANT - The addition of anything that may interfere with the normal operation of the appliance without express written permission from the manufacturer or his agent could invalidate the appliance warranty. In GB this could also infringe the GAS SAFETY (Installation and Use) REGULATIONS. IMPORTANT - Installation, Commissioning, Service & Repair This appliance must be installed in accordance with the manufacturer s instructions and the regulations in force. Read the instructions fully before installing or using the appliance. Baxi is one of the leading manufacturers of domestic heating products in the UK. Our first priority is to give a high quality service to our customers. Quality is built into every Baxi product - products which fulfil the demands and needs of customers, offering choice, efficiency and reliability. In GB, this must be carried out by a competent person as stated in the Gas Safety (Installation & Use) Regulations. Definition of competence: A person who works for a Gas Safe registered company and holding current certificates in the relevant ACS modules, is deemed competent. In IE, this must be carried out by a competent person as stated in I.S. 813 Domestic Gas Installations. To keep ahead of changing trends, we have made a commitment to develop new ideas using the latest technology - with the aim of continuing to make the products that customers want to buy. Everyone who works at Baxi has a commitment to quality because we know that satisfied customers mean continued success. We hope you get a satisfactory service from Baxi. If not, please let us know. 0086 ISO 9001 FM 00866 2

1.0 Warnings Notice Discolouration of wall surfaces Most heating appliances generate warm air convection currents and transfer heat to any wall surface against which they are situated. Some soft furnishings (such as blown vinyl wallpapers) may not be suitable for use where they are subject to temperatures above normal room levels and the manufacturer's advice should be sought before using this type of wall covering adjacent to any heating appliance. The likelihood of wall staining from convected air currents will be increased in environments where high levels of tobacco smoke or other contaminants exist. Although the fire appears similar to a coal fire when operating care should be taken to avoid throwing rubbish onto the coalbed. Guarding This appliance has a naked flame and a fireguard conforming to B.S. 6539 or 6778 should be used, especially in instances where young children, the elderly or infirm are likely to be present. Shelf Never Hang Flammable Items Over The Appliance 1. If a shelf is to be fitted above the fire, then it must be at least 126mm (5in) above the fire and not more than 178mm (7in) in depth. 2. Alternatively, a 229mm (9in) deep shelf may be fitted, but must be at least 180mm (7 1 /8in) above the fire. 1.1 Safe Installation The appliance is suitable only for installation in GB and IE and should be installed in accordance with the rules in force. In GB, the installation must be carried out by a Gas Safe Registered Installer. It must be carried out in accordance with the relevant requirements of the: Gas Safety (Installation & Use) Regulations. The appropriate Building Regulations either The Building Regulations, The Building Regulations (Scotland), Building Regulations (Northern Ireland). The Water Fittings Regulations or Water Byelaws in Scotland. The Current I.E.E. Wiring Regulations. Where no specific instructions are given, reference should be made to the relevant British Standard Code of Practice. In IE, the installation must be carried out by a competent Person and installed in accordance with the current edition of I.S. 813 Domestic Gas Installations, the current Building Regulations and reference should be made to the current ETCI rules for electrical installation. Read the instructions before installing or using this appliance. Any purpose provided ventilation should be checked periodically to ensure that it is free from obstruction. 1.2 Important Information All Gas Safe registered engineers carry a ID card with their licence number and a photograph. You can check your engineer is registered by telephoning 0800 408 5500 or online at www.gassaferegister.co.uk This product uses fuel effect pieces containing Refractory Ceramic Fibres (R.C.F.) which are manmade vitreous silicate fibres. Excessive exposure to these materials may cause temporary irritation to eyes, skin and respiratory tract. Care must be taken when handling these articles to ensure the release of dust or fibres is kept to a minimum. Refer to section 6.1 Cleaning the Fire. 1.3 In case of gas leaks If a gas leak is found or suspected, turn off the gas supply at the meter immediately and telephone the National Gas Emergency Service on:- 0800 111 999 1.4 Servicing your Appliance For reasons of safety and economy your appliance should be serviced annually. Your Installer will be able to advise you. 3

2.0 Introduction 2.1 Introduction Boiler Thermostat Knob 1. Your Baxi Bermuda Inset 3 Super is a central heating boiler combined with a gas fire. The firefront is of the Decorative Fuel Effect type and incorporates an optional illumination effect for use when the fire is off. The boiler will provide heating for the rest of the house and also domestic hot water if required. The boiler and fire are independently controlled. Green Power ON Indicator ON/OFF Button 2. The boiler may be controlled by an external programmer or clock control (see separate instructions with the clock controller used). Manual control is available with the boiler thermostat control. Green High Setting Indicator HIGH/LOW Button Controls Access Door Bermuda Inset 3 KS Super NOTE: The fire or illumination effect will not function in the event of a power failure. 2.2 Controls and Identification (Fig. 1) Green Illumination ON Indicator 1. The controls for the fire are situated on the upper left hand side of the fire surround. Illumination Button Fig. 1 2. Remove the controls access door at the bottom of the fire to gain access to the boiler controls. Controls & Bezel 3. Fire identification is situated on the inner right hand side panel behind the controls access door. 4. Boiler identification is on the boiler controls behind the controls access door. 5. Before operating the unit ensure that the main gas and electricity supplies are turned on. Boiler Thermostat Knob 2.3 Pilot/A.S.D. 1. Both the boiler and firefront are fitted with a pilot light that also acts as an Atmospheric Sensing Device. This means that in the event of the flow of gases out of the flue being interrupted the pilots will extinguish and shut the fire and boiler down. If this occurs persistently your Service Engineer should be contacted immediately. Controls Access Door Bermuda Inset 3 FS Super 4

3.0 Operating the Boiler 3.1 To light the boiler (Fig. 2 & 2a) Ensure that all external controls, e.g. room thermostat, timer etc., are calling for heat. To operate the pilot turn the thermostat knob to the desired position. The indicator light will illuminate once the pilot is lit. The burner will also light shortly after the pilot has been established. The pilot is intermittent and only lights when there is a call for heat. If the boiler cannot be lit by the above method consult your Service Engineer. 3.2 To adjust the boiler temperature (Fig. 2) Controls Access Door Boiler Controls Turn the boiler thermostat knob clockwise to the required setting. The optimum boiler thermostat setting depends upon type of system, external controls and your requirements. Your Installer will be able to advise you on this matter. 3.3 Resetting the boiler 50/6 Boiler Controls Pilot Viewing Window Gas Service Cock 1. Inset 3 Boiler 50/6 (Fig. 2). If the indicator light is illuminated red/or flashing red, it is necessary to reset the appliance. To do this turn the boiler thermostat control knob fully anti-clockwise to the OFF position and wait until the light shows orange. Turn the control knob clockwise to the required setting. The boiler will commence the ignition sequence. Fig. 2 Indicator Light Boiler Thermostat Knob 3.4 To switch off the boiler for short periods (Fig. 2) 1. Turn the boiler thermostat knob fully anticlockwise to the off position (O) until it clicks. 3.5 To switch off the boiler for long periods (Fig. 2) 1. Turn the boiler thermostat knob fully anticlockwise to the off position (O) until it clicks. 2. It is recommended that if the system is left off for long periods during cold weather the whole system is drained to avoid frost damage. 3. Advice on draining the system can be obtained from your Service Engineer. 5

4.0 Operating the Fire The fire is controlled by three switches situated on the upper left hand side of the fire surround. The illumination effect operates independently to the High & Low gas rates on the fire. 4.1 To operate the illumination effect (Fig. 3) 1. To switch on the illumination, press the button once. The green indicator will come on to confirm this. 2. To switch off the illumination, press the button once. Green Power ON Indicator ON/OFF Button Green High Setting Indicator HIGH/LOW Button Green Illumination ON Indicator Illumination Button Controls & Bezel Fig. 3 4.2 To light the fire (Fig. 3) 1. The fire has three settings:- OFF LOW HIGH 2. The ON button has a safety feature built in. It should be pressed and held for 3-4 seconds. (The green power ON indicator comes on when the ON/OFF button is pressed.) 3. During the ignition sequence you will hear an audible signal. This lasts for up to 20 seconds. The fire will then automatically ignite on the low setting. NOTE: If the ON/OFF button is pressed and held for less than 3 seconds the fire will not ignite. This is a built in safety feature. 4. If the fire fails to ignite or goes out at any time, switch the fire off and repeat the procedure. 5. If you require the fire on the high setting, press the High/Low button. The green high setting indicator will come on to confirm this. This operation can be undertaken during the ignition sequence. NOTE: It is recommended that the fire is operated on HIGH initially. 6. To change the fire from high to low, press the High/Low button once. The green high setting indicator will go out to confirm this. NOTE: When your Bermuda Inset 3 Super is first used it is possible some smells may be emitted. These smells will quickly clear with use. 4.3 To turn the fire off (Fig. 3) 1. Pressing the ON/OFF button once will turn the fire off and the green power ON indicator will go out to confirm this. 6

Side Cheek Location Stop 5.0 Arranging the Coals 5.1 Arranging the Coals It is important that all the coals are used and arranged as shown in order to achieve the desired flame picture. Fig. 4 CAUTION: The coals are extremely fragile and must be handled accordingly. Gloves should be worn and any inhalation of the dust should be avoided. Keep the coals away from children at all times. Never use coals other than those originally supplied or Genuine Baxi Spare Parts. Never put additional coals on the fire. Please read section 1.2 Important Information and section 6.1 Cleaning the Fire. Rear Coal Side Support Ledges Fig. 5 Combustion Box Base Front Lip 1. It may be necessary to remove some or all of the coals to retouch or clean them at some time. Cleaning must only be done using a very soft brush. Any areas of the coal bed where the coating has deteriorated may be retouched using the black stain available direct from Baxi or from your local Baxi Spares Stockist. Quote Part N o 043224 when ordering. Rear Coal Spacer Lugs 2. The following procedure assumes all the loose coals, side cheeks, rear and front coals are to be fitted. If not all the coals require replacement, refer to the diagrams and determine at which point you need to commence. 3. Place the right / left hand side cheeks against the combustion box side walls (Fig. 4). Burner Bracket Lip Fig. 6 Fig. 7 4. Locate the rear coal behind the combustion box base front lip and angle it back against the side cheek location stops (Figs. 4 & 5). 5. Locate the front coal onto the rear coal side support ledges and behind the lip of the burner bracket (Figs. 5 & 6). 6. Place 5 of the loose coals into the location recesses of the front coal, (flat face downward). The 3 centre coals should rest against the corresponding rear coal spacer lugs. Orientation of the coals should be as shown in order to achieve the desired flame picture (Fig. 7). 7. Place the remaining 4 loose coals between the front loose coals and the rear coal, (flat face downwards). Orientation of the coals should be as shown in order to achieve the desired flame picture (Fig. 8). Fig. 8 7

6.0 Spares and Cleaning 6.1 Cleaning the Fire 1. The fire may be cleaned with a damp cloth and wiped with a soft duster. Do not use metal polish on any parts of the appliance. Glass Retaining Assembly 2. It is possible that some soot may be deposited on the coals after use. This is acceptable providing it is not allowed to accumulate. Should any soot accumulation become excessive the fuel effect pieces should be removed from the fire for cleaning. it is recommended that gloves are worn when handling these items. Cleaning should be carried out in a well-ventilated area or the open air by gently brushing with a soft brush with the pieces/bed held away from the face to avoid inhaling the dust. The use of a normal domestic vacuum cleaner is not recommended as it may blow dust back into the air. Care must also be taken if retouching the fuel effect pieces is required. Always wash hands thoroughly after handling the fuel effect pieces. 6.2 Changing the Bulbs Fig. 9 IMPORTANT: Only replace the bulb/s with a 12V 20W halogen capsule bulb available at most DIY outlets, specialist electrical stores or from Baxi. 1. Remove the coals, placing them on a newspaper or similar to prevent soiling furnishings. 2. Lift out the glass retaining assembly (Fig. 9). Halogen Bulbs Fig. 10 3. Remove the bulb by pulling out from the ceramic bulb holder to disengage the pins (Fig. 10). 4. Fit the replacement bulb in reverse order. NOTE: Halogen bulbs should not be handled with bare fingers. Always use a cloth to grip the bulb. 5. Replace the glass retaining assembly and reassemble the coal bed (see Arranging the Coals - section 5.0). 6.3 Cleaning or Changing the Glass Amber Glass Pieces 1. Remove the coals, placing them on a newspaper or similar to prevent soiling furnishings. 2. Lift out the glass retaining assembly (Fig. 9). 3. Carefully remove the three amber glass pieces and clean (Fig. 11). 4. Fit the new or cleaned glass and reassemble the coals. Fig. 11 8

7.0 Guarantee 7.1 Guarantee 1. Your Baxi Bermuda Inset 3 Super is designed and produced to meet all the relevant Standards. 2. Baxi provide a 3 year guarantee on the Bermuda - other parts of the system are covered by the Installer or other manufacturers. The guarantee operates from the date installation is completed for the customer who is the original user. 3. To maximise the benefit from our guarantee we urge you to return the reply-paid guarantee registration. 4. This does not in any way prejudice your rights at Common Law. Such rights between the customer and the installer or supplier from whom the unit was purchased remain intact. Any component or part which becomes defective during the guarantee period as a result of faulty workmanship or material whilst in normal use will be repaired or replaced free of charge. 9

10 8.0 Notes

8.0 Notes 11

All descriptions and illustrations provided in this leaflet have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet. All goods are sold subject to our standard Conditions of Sale which are available on request. BAXI A Trading Division of Baxi Heating UK Ltd (3879156) Brooks House, Coventry Road, Warwick. CV34 4LL After Sales Service 0844 871 1525 Technical Enquiries 0844 871 1555 Website www.baxi.co.uk e&oe Comp N o 247853 - Iss 6-9/10