Mira Atom ERD Thermostatic Bar Valve

Similar documents
Mira Reflex Thermostatic Bar Valve

Mira Minilite Exposed Mira Minilite EV Mira Moto EV

Mira Atom ERD With Moxie

Mira Select Flex Thermostatic Mixer

Mira Advance THERMOSTATIC ELECTRIC SHOWER. 8.7 and 9.8 kw. These instructions must be left with the user. User Guide W5-A

Mira Sport Thermostatic

These instructions must be left with the user.

These instructions must be left with the user.

These instructions must be left with the user.

Mira Platinum Wireless Controller

These instructions must be left with the user.

These instructions must be left with the user.

Mira Platinum Wireless Controller

These instructions must be left with the user.

These instructions must be left with the user.

Mira Realm Thermostatic Mixer

Mira Elite QT 9.8kW / 10.8kW

Thermostatic Bar Valve

These instructions must be left with the user.

MIRA SELECT THERMOSTATIC MIXER INSTALLATION & USER GUIDE. These instructions must be left with the user. 1. Please call us on (UK Only)

Thermostatic Bar Valve THE QUALIFICATIONS INSTALLATION INSTRUCTIONS

These instructions are to be left with the user

Thermostatic Bar Valve THE QUALIFICATIONS INSTALLATION INSTRUCTIONS

Express Thermo Shower Mixer Set With Handset THE QUALIFICATIONS INSTALLATION INSTRUCTIONS

These instructions must be left with the user.

Mira Meta 8.5, 9.5 and 10.8 kw Electric Shower

These instructions are to be left with the user

Mira Sport Max with Airboost

THE QUALIFICATIONS INSTALLATION INSTRUCTIONS NEW SQUARE EXPOSED THERMOSTATIC SHOWER VALVE CHR

THERMOSTATIC SHOWER VALVE

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Mira Sport Max with Airboost

These instructions are to be left with the user

These instructions must be left with the user.

Mira Galena. 9.8 kw. These instructions must be left with the user. Installation and User Guide. Please call us on (UK Only)

Mira Orbis. 9.0, 9.8 & 10.8 kw. These instructions must be left with the user. Installation and User Guide. Please call us on (UK Only)

Mira Escape Thermostatic

Mira Elite ST 9.8, 10.8 kw

Installation, Operating and Maintenance Guide

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Thames thermostatic bar mixer with diverter Installation and operating instructions

Oltis thermostatic bar mixer

Dove Eco thermostatic bar mixer shower

NENE. Installation and Operating Instructions. Thermostatic bar mixer shower PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Sema thermostatic bar mixer Installation and operating instructions

EDEN. Installation Instructions. Bath shower manual mixer tap INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Thermostatic bar mixer valve with adjustable head Installation guide

These instructions must be left with the user.

Installation and User Guide

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

9.0 & 9.8 KW MIRA SPORT THERMOSTATIC ELECTRIC SHOWER. Installation & User Guide. These instructions are to be left with the user 1

Mira Vie Electric Shower 8.5, 9.5 & 10.8 kw

MIDAS. Installation instructions 110/220

Thermostatic. THERMOSTATIC POWER SHOWER Installation and User Guide. These instructions are to be left with the user 1

Installation, Operating and Maintenance Guide

AIRE. Thermostatic bath shower mixer. Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Thermostatic bar mixer shower. Installation and Operating Instructions. Installers please note these instructions are to be left with the user

FERVORE thermostatic mixer shower Installation and operating instructions

Singulier Spout Tube Basin Mixer Installation and User Guide

Florino thermostatic mixer shower

Leona thermostatic bar mixer shower pole Installation and operating instructions

MATINO thermostatic bar mixer shower Installation and operating instructions

Installation Instructions Flute Tap Range

Artisan Thermostatic Bath Filler

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide

Nema manual bar mixer shower Installation and operating instructions

Mira 1.5 bar Twin Ended Pump Mira 2.0 bar Twin Ended Pump

Safetherm PRODUCT MANUAL

These instructions are to be left with the user

Atmos Energy. Thermostatic Concentric Mixer Valve with Overhead. Fitting Instructions

Oblo Basin and Bidet Monobloc Installation and User Guide

CROMO manual mixer shower

TYNE. Installation and Operating Instructions. Thermostatic bar mixer shower PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Bar valve with fixed and adjustable shower heads. Installation guide. Midas Plus installation instructions Page 1

TYNE. Installation and Operating Instructions. Thermostatic bar mixer shower. Installers please note these instructions are to be left with the user

PIRLO - cool touch thermostatic bar mixer shower

Bar Mixer Shower With Diverter

AIRE Thermostatic bar mixer Installation and operating instructions

THAMES mini exposed sequential thermostatic mixer shower Installation and operating instructions

Flipside Handshower and Showerhead Installation and User Guide

EDEN Thermostatic Bar Mixer Shower with Diverter

These instructions are to be left with the user

Mira Jump MIRA JUMP ELECTRIC SHOWER. Installation and User Guide. These instructions are to be left with the user 1

ELINA concentric exposed thermostatic mixer valve

EXCELLENTE Thermostatic mixer shower and diverter Installation and operating instructions

Bath Shower Mixer

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

Sharis Eco thermostatic bar mixer shower

INTA ION MODERN BAR / BATH SHOWER MIXER CP

SENATA thermostatic bar mixer shower Installation and operating instructions

Mira Advance THERMOSTATIC ELECTRIC SHOWER. 8.7 and 9.8 kw. These instructions must be left with the user. Installation Guide W2-A

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve

SENATA thermostatic bar mixer shower

Enzo Concealed Shower Mixing Valve

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

OWNER S GUIDE SEQUENTIAL THERMOSTATIC SHOWER VALVE. 150mm Inlet Pipe Centres. Shower Control. Handles and. may differ depending.

AQ150:Midas 10/9/15 14:50 Page 1 AQ150. Thermostatic bar mixer valve with adjustable head. Installation guide

THAMES Thermostatic vertical mixer shower Installation and operating instructions

Transcription:

Mira Atom ERD Thermostatic Bar Valve These instructions must be left with the user Installation and User Guide 1 1340912-W2-A

1340912-W2-A 2

Introduction Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide thoroughly, having done so, keep it handy for future reference. Guarantee For domestic installations, Mira Showers guarantee the Mira Atom against any defect in materials or workmanship for a period of five years from the date of purchase (shower fittings for one year). For non-domestic installations, Mira Showers guarantee the Mira Atom against any defect in materials or workmanship for a period of one year from the date of purchase. Failure to follow the instructions provided with the shower will invalidate the guarantee. For Terms and Conditions refer to the 'Customer Service'. Design Registration & Patents Design Registration: GB 001225254-0003 Patents: GB 2 407 138 Recommended Usage Domestic Light Commercial Heavy Commercial Healthcare 3 1340912-W2-A

Pack Contents 1 x Mounting Brackets 1 x Concealing Cover 2 x Fixing Screws 1 x Grubscrew 1 x Bar Valve 1 x Overhead 1 x Riser Arm 2 x Wall Brackets 3 x Seals 2 x Olives 1 x Middle Pipe 2 x Compression Nuts 1 x Handset 2 x Concealing Plates 2 x Hose Washer 1 x Hose 2 x Washers/Filters 1 x Clamp Bracket 2 x Wall Plugs Hose Retaining Ring 2 x Lower Pipe 2 x Fixing Screws 1340912-W2-A 4

Safety Information WARNING - This product can deliver scalding temperatures if not operated, installed or maintained in accordance with the instructions, warnings and cautions contained in this guide. The function of a thermostatic mixing valve is to deliver water consistently at a safe temperature. In keeping with every other mechanism, it cannot be considered as functionally infallible and as such, cannot totally replace a supervisor s vigilance where that is necessary. Provided it is installed, commissioned, operated and maintained within manufacturers recommendations, the risk of failure, if not eliminated, is reduced to the minimum achievable. PLEASE OBSERVE THE FOLLOWING TO REDUCE THE RISK OF INJURY: Mira thermostatic mixers are precision engineered and should give continued safe and controlled performance, provided: 1. They are installed, commissioned, operated and maintained in accordance with the manufacturer s recommendations. 2. Periodic attention is given, when necessary, to maintain the product in good functional order. Caution! 1. Read all of these instructions and retain this guide for later use. 2. Installation must be carried out in accordance with these instructions, and must be conducted by designated, qualified and competent personnel. 3. Pass on this guide in the event of change of ownership of the installation site. 4. Follow all warnings, cautions and instructions contained in this guide. 5. Make sure that you fully understand how to operate this shower before use, read all operating instructions and retain this guide for future reference. 5 1340912-W2-A

6. This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the product by a person responsible for their safety. 7. Children should be supervised to ensure that they do not play with the product. 8. DO NOT perform any unspecified modifications to the shower or its accessories. When servicing only use genuine Kohler Mira replacement parts. 9. DO NOT fit any form of outlet flow control. Only Mira recommended outlet fittings should be used. 10. DO NOT operate the temperature control rapidly, allow 10 15 seconds for the temperature to stabilise before use. 11. Care is required when adjusting flow or temperature, make sure that the temperature has stabilised. 12. Care is required if the product is turned off and back on during showering as this may result in unstable temperature. Ensure temperature has stabilised before re-using product. 13. Sunburn or skin conditions can increase your sensitivity to hot water. Make sure that you set the shower to a cooler temperature. 14. The water supplies to this product must be isolated if the product is not to be used for a long period of time. If the product or pipework is at risk of freezing during this period they should also be drained of water. 15. When this product has reached the end of its serviceable life, it should be disposed of in a safe manner, in accordance with current local authority recycling, or waste disposal policy. 1340912-W2-A 6

Specification Pressures Max Static Pressure: 10 Bar. Max Maintained Pressure: 5 Bar. Min Maintained Pressure: (Gas Water Heater): 1.0 Bar (for optimum performance supplies should be nominally equal). Min Maintained Pressure (Gravity System): 0.1 Bar (0.1 bar = 1 Metre head from cold tank base to shower handset outlet). Temperatures Close temperature control is provided between 20 C and 50 C. Optimum Thermostatic Control Range: 35 C to 45 C (achieved with supplies of 15 C cold, 65 C hot and nominally equal pressures). Recommended Hot Supply: 60 C to 65 C (Note! The mixing valve can operate at temperatures up to 85 C for short periods without damage. However for safety reasons it is recommended that the maximum hot water temperature is limited to 65 C). Minimum Recommended Differential between Hot Supply and Outlet Temperature: 12 C at desired flow rates. Minimum hot water supply temperature: 55 C. Thermostatic Shut-down For safety and comfort the thermostat will shut off the mixing valve within 2 Seconds if either supply fails (achieved only if the blend temperature has a minimum differential of 12 C from either supply temperature). Connections Hot: Left - 15mm pipework, 3/4 BSP to valve. Cold: Right - 15mm pipework, 3/4 BSP to valve. Outlet: Bottom, 1/2 BSP Male to flexible hose. Note! This product does not allow for reversed inlets and will deliver unstable temperatures if fitted incorrectly. 7 1340912-W2-A

Installation Suitable Plumbing Systems Gravity Fed: The thermostatic mixer must be fed from a cold water cistern (usually fitted in the loft space) and a hot water cylinder (usually fitted in the airing cupboard) providing nominally equal pressures. Gas Heated System: The thermostatic mixer can be installed with a combination boiler. Unvented Mains Pressure System: The thermostatic mixer can be installed with an unvented, stored hot water system. Mains Pressurised Instantaneous Hot Water System: The thermostatic mixer can be installed with systems of this type with balanced pressures. Pumped System: The thermostatic mixer can be installed with an inlet pump (twin impeller). The pump must be installed on the floor next to the hot water cylinder. General 1. Installation of the shower must be carried out in accordance with these instructions by qualified, competent personnel. 2. The installation must comply with the Water Supply Regulations 1999 (Water Fittings) or any particular regulations and practices, specified by the local water company or water undertakers. 3. Make sure all pressures and temperatures comply with the requirements of the shower. See Specifications. 4. The product must not be installed in an area where it may freeze. Pipework to the product that could become frozen must be properly insulated. 5. DO NOT install the product in a position in which service access is restricted. 6. For stud partitions alternative fixings may be required. 7. Isolating valves must be installed close to the product for ease of maintenance. 8. Pipework must be rigidly supported and avoid any strain on the connections. 9. Pipework dead-legs should be kept to a minimum. 10. If pipework enters the product from the rear through a hole in the wall, provision must be made to prevent water ingress back into the wall structure. 1340912-W2-A 8

11. The position of the shower and shower fittings must provide a minimum gap of 25 mm between the showerhead and the spill over level of any bath, shower tray or basin and a minimum gap of 30 mm between the showerhead and the spill over level of any toilet, bidet or other appliance with a Fluid Category 5 backflow risk (see diagram). Mixer Shower 30 mm Minimum Toilet or Bidet FC5 25 mm Minimum Bath or Shower Tray FC3 Zone of Backflow Risk 25 mm Minimum Hand Basin FC3 Note! There will be occasions when the hose retaining ring will not provide a suitable solution for Fluid Category 3 installations, in these instances an outlet double checkvalve must be fitted, this will increase the required supply pressure typically by 10kPa (0.1 bar). Double checkvalves fitted in the inlet supply to the appliance cause a pressure build up, which affect the maximum static inlet pressure for the appliance and must not be fitted. For Fluid category 5, double checkvalves are not suitable. 12. The showerhead should be positioned so that it discharges down the centre line of the bath or across the opening of a shower cubicle. 13. Only use the inlet connections supplied with the product. DO NOT use any other type of fittings. 14. All pipework must be checked for leaks before the product installation is completed. The product should be pressurised & the inlet & outlet connections inspected. 15. DO NOT overtighten connections, screws or grubscrews as product damage may occur. 16. Upon completion of installation, or if the product is dismantled during installation or servicing, then the product must be inspected to ensure that there are no leaks. 17. Having completed the installation, make sure that the user is familiar with the operation of the product. 9 1340912-W2-A

Installation of the Bar Valve Before installing the pipework, please ensure that there is a minimum of 1065 mm height clearance to allow for the rigid riser and overhead to be installed above. If installing in a restricted height area, a shorter riser rail can be ordered as a spare part. 1 2 25 mm HOT COLD Plastic Pipe Guide 25 mm Fit the plastic pipe guide over the inlet pipes. Level the pipe guide and secure to the wall to hold in position. Leave the guide in place and finish the wall. Make sure that the pipework has been installed correctly and that it protrudes 25 mm from the finished wall surface. 3 4 Wall Bracket 8 mm Hold the wall bracket in position and mark the position of the fixing holes. Drill the fixing holes using an 8 mm diameter drill. 1340912-W2-A 10

5 6 Install the wall plugs. Install the fixing screws and tighten. 7 8 Install the olives and the connectors. Tighten finger tight and then another 1/4 to 1/2 turn. Turn on the water supply and flush the pipework. 9 10 Install the concealing plates. Assemble the bar valve with a sealing washer / filter in each inlet and attach to the wall bracket. Note! Connections are: Hot-Left, Cold- Right. 11 1340912-W2-A

Installing the Shower Fittings Riser Arm Fixed Showerhead A Mounting Boss Wall Fixing Bracket Concealing Cover Riser Arm Middle Bar Showerhead Clamp Bracket Hose A Red Protective Cover or White label. Remove before Fitting Hose Retaining Ring Lower Bar Important! Seal A is pre-fitted inside the lower bar. 1340912-W2-A 12

1. Slide the hose retaining ring and the clamp bracket onto the middle bar, and then screw the middle and lower bar sections together. 2. Screw the riser arm to the middle and lower bar section. 3. Push the riser bar into the top of the bar valve. Note! The riser bar must be located correctly, push down firmly to seat it. 4. Insert the wall fixing bracket into the riser arm mounting boss, then swivel the bar if necessary to reposition the wall fixing bracket against the wall. Note! The grubscrew mounting hole must be positioned at the top. 5. Mark the holes for the wall fixing bracket. Note! Use a spirit level to ensure the bar is vertical. 6. Remove the wall fixing bracket from the mounting boss then remove the riser bar from the bar valve. 7. Drill two holes to suit the wall fixings, ensuring that the bar valve is protected from debris. Fix the bracket to the wall. 8. Refit the riser bar into the bar valve and then put the concealing cover onto the riser arm mounting boss. 9. Push the riser arm mounting boss onto the wall fixing bracket. 10. Fit and tighten the grubscrew (2.5 mm hexagonal key) into the hole on top of the mounting boss then push the concealing cover over the wall fixing bracket. 11. Tighten the grubscrew at the valve end and fit the grubscrew cover. 12. Screw the fixed shower head onto the riser rail. 13. Fit the shower hose onto the bottom outlet of the bar valve. Note! The shower hose has slightly different sized conical connections at each end (the smaller diameter / longer length conical is identified with a Red protective cover or a White label). The end with the red cover or white label connects to the showerhead, the clear end connects to the valve. 14. Push the shower hose through the retaining ring and screw it to the showerhead. 15. Place the showerhead into the clamp bracket, adjusting the angle and height to the users preference. 13 1340912-W2-A

Commissioning Maximum Temperature Setting Before using the shower, the maximum temperature must be checked to make sure that it is at a safe level. It has been preset to a safe showering temperature under ideal conditions at the factory, appropriate for most systems. However, site conditions and personal preference may make it necessary to reset this temperature. Note! Make sure that the hot water temperature is at least 55 C and that there is sufficient supply. Caution! Before testing the mixer, make sure that the hot and cold water is flowing correctly by exercising the temperature selector knob between the cold and hot stops. 1. Turn the temperature selector knob anticlockwise until it stops and test that the temperature of the water from the shower outlet is hot enough. 2. If not, depress the override button and carefully rotate the knob further. If the water temperature is still not hot enough complete the following procedure. 3. Rotate the temperature selector knob back to the override position. 4. Push in and rotate the concealing cap clockwise to remove. Remove the fixing screw. 5. Pull off the temperature selector knob without disturbing the stop assembly. 6. Replace the temperature selector knob so that the lever is the 1 O'clock position. 7. Rotate the temperature selector knob against the stop, wait for the water to stabilise and test that the temperature of the water from the shower outlet is hot enough. If the water temperature is still not hot enough repeat the procedure until a maximum safe temperature is achieved at the override position. 8. Refit and tighten the fixing screw, refit the concealing cap. Temperature Selector Knob Stop Assembly Concealing Cap Fixing Screw Push in and rotate to remove 1340912-W2-A 14

Operation Decrease Temperature Temperature Override Button Increase Temperature OFF Temperature Selector Knob Flow Selector Knob Adjusting the Temperature The temperature is controlled by rotating the temperature selector knob. For safety reasons, the temperature is limited by an override stop. To obtain a higher temperature, press the override button on the temperature selector knob and continue to rotate the knob. Adjusting the Flow The flow is controlled by rotating the flow selector knob to either the overhead or showerhead mode. Cleaning Cleaning Many household cleaners contain abrasives and chemical substances, and should not be used for cleaning plated or plastic fittings. These finishes should be cleaned with a mild washing up detergent or soap solution, and then wiped dry using a soft cloth. Important! The showerhead must be descaled regularly, keeping the showerhead clean and free from limescale will ensure that your shower and showerhead continue to perform to their maximum. A blocked showerhead can restrict the flow rate and may cause damage to your shower. 15 1340912-W2-A

Fault Diagnosis If you require a Mira trained service engineer or agent, refer to Customer Service. Symptom Water too hot or too cold Poor temperature control Fluctuating or reduced flow Water leaking from the shower handset/overhead Cause / Rectification Inlets reversed (hot supply to cold inlet of shower unit), rework inlet pipework. Check the washer / filters for any blockage. Check the maximum temperature setting (If you have a combination type boiler it may not be producing sufficient hot water at the desired flow rate). Fit a flow regulator to the outlet of the shower unit. Installation conditions outside operating parameters, refer to Specifications and Commissioning. Make sure that the inlet temperature differentials are sufficient, refer to Specifications. Check the shower handset, showerhead, hose and filters for any blockage. Make sure that the maintained inlet pressures are nominally balanced and sufficient, refer to Specifications. Air lock or partial blockage in the pipework. Normal for a short period after shut off. Check that the pressures are not in excess of the specifications for this product. 1340912-W2-A 16

Spare Parts 1836.182 Riser Arm 1736.733 Wall Fixing 1799.012 Overhead - 250mm White 1836.179 Fixing Kit 1836.171 Concealing Plates 1736.732 Middle Bar 1703.203 Clamp Bracket 1836.174 Inlet Seal/ Filter 1836.247 Plug 632.73 Hose Seal (x2) 1740.649 Beat 110 Multi Mode Showerhead 1836.244 Flow Cartridge Nut 1836.166 Flow Knob Assembly 1836.170 Flow Cartridge 1703.199 Hose Retaining Ring 150.58 Hose (1.25 M) 1836.163 Cartridge 1744.108 Nut Thermostatic Cartridge 1836.164 Temperature Knob Assembly 1736.734 Lower Bar 1736.735 Short Bar A short bar can be ordered if the ceiling height is not sufficient for the standard bar length. 1736.740 Seal Pack - Components Identified A 17 1340912-W2-A

Notes 1340912-W2-A 18

Notes 19 1340912-W2-A

Customer Service Guarantee Your product has the benefit of our manufacturer s guarantee which starts from date of purchase. This guarantee only applies in the United Kingdom and Republic of Ireland. To activate this guarantee, please return your completed registration card, visit our website or free phone 0800 5978581 within 30 days of purchase (UK only). Within the guarantee period we will resolve defects in materials or workmanship, free of charge, by repairing or replacing parts or product as we may choose. This guarantee is in addition to your statutory rights and is subject to the following conditions : The guarantee applies solely to the original installation under normal use and to the original purchaser only. The product must be installed and maintained in accordance with the instructions given in this guide. Servicing must only be undertaken by us or our appointed representative. Note! If a service visit is required the product must be fully installed and connected to services. Repair under this guarantee does not extend the original expiry date. The guarantee on any replacement parts or product ends at the original expiry date. For shower fittings or consumable items we reserve the right to supply replacement parts only. The guarantee does not cover: Call out charges for non product faults (such as damage or performance issues arising from incorrect installation, improper use, inappropriate cleaning, lack of maintenance, build up of limescale, frost damage, chemical attack, corrosion, system debris or blocked filters) or where no fault has been found with the product. Water or electrical supply, waste and isolation issues. Compensation for loss of use of the product or consequential or indirect loss of any kind. Damage or defects caused if the product is repaired or modified by persons not authorised by us or our appointed representative. Routine maintenance or replacement parts to repaired or modified by persons not authorised by comply with the requirements of thetmv2 or repaired or modified by persons not authorised by TMV3 healthcare schemes Accidental or wilful damage. Products purchased ex-showroom display. What to do if something goes wrong If your product does not work correctly refer to this manual for fault diagnosis and check that it is installed and commissioned in accordance with our instructions. If this does not resolve the issue, contact us for help and advice. Helpdesk Service Contact our Customer Services Team for product advice, to purchase spare parts or accessories or to set up service visit. You can contact us via phone or e-mail - contact details below. Please provide your model name, power rating (if applicable) and date of purchase. Mira Showers Website (www.mirashowers.co.uk) Visit our website to register your guarantee, download user guides, diagnose faults, purchase our full range of accessories and popular spares, or request a service visit. Spares and Accessories We hold the largest stocks of genuine Mira spares and accessories.contact us for a price or visit our website to purchase items from our accessory range and popular spares. (Only available in the United Kingdom ) Service/Repairs No one knows our products better than our nationwide team of Service Technicians. We can carry out service or repair work to your product both during and after the guarantee period. (Only available in the United Kingdom and Republic of Ireland) Ask about our fixed price service repairs. To Contact Us: UK 0844 571 5000 Calls cost 7p per minute plus your phone company s access charge Fax: 01242 282595 Email Visit www.mirashowers.co.uk/contactus By Post: Mira Customer Services Dept, Cromwell Road, Cheltenham, Gloucestershire GL52 5EP To Contact Us: Eire Only 01 531 9337 E-mail: CustomerServiceEire@mirashowers.com Mira is a registered trade mark of Kohler Mira Limited. The company reserves the right to alter product specifications without notice. 14648 1340912-W2-A 20 Kohler Mira Limited, February 2018