Fan Coil Unit CULTRA

Similar documents
Fire protection unit

Cooling Strip Model SPB

Additional operating instructions according to ATEX 2014/34/EU Ceiling Impulse Diffuser Model PIL

Installation, Mounting and Maintenance DISA-300

Units for suspended ceilings

TopVent Design Handbook

System architecture. Air treatment Index

Ceiling diffusers. Type DLQL

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

Ceiling swirl diffusers

Units for suspended cei lings

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

BKA-EN Fire Damper. Additional operating instructions according to

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

Ceiling swirl diffusers

BSK-RPR Fire Damper. Additional operating instructions according to

CASSETTE UNIT. Comfort Circle

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

Ceiling air diffuser INDULTHERM INDULTHERM-e

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

Polaris-I-60. active chilled beam. the future of space conditioning

Recessed. Air Curtain. Fig 1. Recessed air curtain

Technology for life. Unit heater LH

CONDOR. Supply air ceiling QUICK FACTS

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

Ceiling air diffuser INDULTHERM INDULTHERM-e

Energy-efficient heat source provides comfort in large rooms

RoofVent Design Handbook

Heating and cooling ceiling systems Suspended ceiling systems. Heating Cooling Fresh Air Clean Air

Precision air handling cabinets Ciatronic MICRO/EXPAIR

Press Release. How can the efficiency of the dryer section be increased? Dryer Section All Paper Grades. Heimbach wherever paper is made.

Air curtains. 114 MRX condensing gas air curtain. 118 MRA-H gas air curtain. 121 MRA-A ventilation only air curtain

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS

Halton Rex for Vario R6O - Variable air volume chilled beam

GREENKIT Smoke extraction and ventilation system for lift shafts

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

Krantz. Multifunction exposed ceiling AVACS. Cooling and heating systems

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

PREEVA air handling unit

EEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

TopVent. Recirculation Units and Supply Air Units for Heating and Cooling High Spaces.

NEW RANGE OF WARM AIR CURTAINS

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

Static cooling ceiling system SKS-4/3 DS 4094 E /1. Technical Selection

WOLF VENTILATION SYSTEM PRICE LIST

Halton Rex 600 Basic R6B - Active chilled beam

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

Technical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers

CHILLED BEAM CASSETTE IQ STAR LYRA

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

42AM. Air heaters PRODUCT SELECTION DATA


Units for suspended ceilings Type DID632

QTS SELECTION TECHNICAL BOOKLET

VERSO Air Handling Units

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

Halton CHB Active chilled beam with boost function for bulkhead installation

Performance Rating of Active Chilled Beams

KLIMA Active Chilled Beams

Küba SG commercial

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

PARASOL EX. Suspended comfort modules QUICK FACTS

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

We have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems

Compact VERTICAL FLAT. Compact. Condensers GCHC/GCVC for HFCs, NH 3

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

LTG Air-Water Systems

Air distribution systems. Opticlean OC-Q...

CLIMACIAT AIR COMPACT

INFO. Compact DUAL. GADC Air Cooler for HFC and CO 2. Dual discharge air cooler with and without integrated condensation water pump.

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

Blower-YEFB-020-3R-1maxVel

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

DESCRIPTION OF TECHNOLOGY

Cleanroom systems. Supply air ceiling and recirculated air ceiling OP. for operating rooms with low-turbulence displacement flow

VERSO Air Handling Units

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level

Use. Worth noting. Key figures. Installation. linx industries chilled beams

PARAGONTM Comfort module for hotel rooms and hospital wards

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

FHE. Dehumidifiers for radiant cooling systems with heat recovery. Display. Versions

OXeN. Ductless ventilation with heat recovery.

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

Brochure EX

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Remote Air Cooled Condensers C2 Series

DX AIR CURTAIN. SensAir

Transcription:

Fan Coil Unit CULTRA Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de

Contents Description...3 Construction... 4 Model... 4 Accessories... 4 Quick selection... 4 Models and dimensions...5 Dimensions... 5 Technical data...6 Cooling capacity / Volumetric flow... 6 Legend...7 Order details...7 Specification texts...8 11/02-2

Description The room air-conditioning module CULTRA, which can be integrated into the wall, allows an absolutely free use of space, thus guaranteeing architectural flexibility. The room air-conditioning module CULTRA is an ambient air cooling device for offices, medical practices, etc. It can also be operated with fresh air or in mixed operation. The dimensions of the wall module have been adjusted to the modular dimensions of lightweight partition walls and allow installation into walls, ceilings or floors. Later in-front-of-the-wall installation is also possible. The room air-conditioning module and its dimensions adapted to lightweight wall construction (minimum height 2 m) allow a cost-efficient and quick installation. In case of changes of room utilization or rebuilding of wall tiles, a quick moving of the room air conditioning module is possible. The user can even take the air-conditioning module with him when moving, as if it were office furniture. A sound-decoupled suspension (on-site) prevents structure-borne noise transmission to the ceiling and the singleplank wall. The room air-conditioning module with the function to cool and heat can replace the conventional heating installation and expensive cooling ceiling technology. The sensible cooling power of max. 880 W is optimised to office spaces of up to 24 m². For larger rooms, more modules can be used. The air volume is 250 m³ maximum per hour. For flexible operation, it is possible to integrate room operating devices from a wide range of brands as an option. Room air is drawn in by the fan through the air intake grille and cleaned by the filter built-in behind. The integrated deflection sound absorber reduces the flow-generated noise. The air is then taken through the cooling or heating register and is temperature-controlled. A further deflection sound absorber is connected downstream for noise reduction. The temperaturecontrolled air is then blown out into the room again through the air intake grille. A quick filter change is possible by means of the easy-to-disassemble air intake grille and for maintenance purposes the complete cover fitted to the device by means of a removable lock can be taken off. The fan is then readily accessible without requiring special tools. Optional accessories for the room air-conditioning module as smooth wall element or with office equipment (white board, diary, media wall) or as room acoustic module with selected designs. A wide range of supply and return air grilles allow a great freedom of creativity. The sound-optimised room climate module can even be used in sound studios. The fan coil unit CULTRA must be installed such it is readily accessible for inspection purposes. Characteristics of each supply and return air diffusers: DSC: The support profile section blades create such a stable jet that, for the two-way air jet or round jet, just one blade has to be set alternately in one outflow direction. This achieves maximum induction while the temperature difference and velocity of the supply air jet are effectively reduced. Due to the central housing of the support profile blades, the free cross-section is always the same size. Accordingly, when the blades are adjusted, the pressure loss and sound power level remain constant. An adjustment of the air outflow direction at a later stage is possible at any time, even when the diffuser has already been fitted. The DSC is built in together with the end pieces. The air diffuser design is fitted without blades as standard. KG: Owing to its compact construction, front frame, blades for air distribution and slot valves for air volume control consist of a single component, as a result of which the compact grille requires only a small mounting depth. This small mounting depth reduces vortex formation at the hitand-miss damper, thus ensuring uniform air intake over the entire diffuser surface of the grille. This model consists of a front frame with visible screw mounting (SM), with pivoting horizontal or vertical air deflection blades and integrated hit-and-miss damper to regulate the air volume. A cover frame in modern design allows concealed mounting (VM) of the grille. DSX-XXL-W-P: The air outflow direction is set ex works to a horizontal, gentle upward outflow position. The high induction ensures fast reduction of the air outflow velocity and of the temperature differential in cooling mode. The DSX-XXL-W is built in together with the end pieces. DBB: The support profile blades create a stable jet and are distinguished in particular by their high flexibility. The integrated blades allow many air distribution patterns even later on. Due to the central housing of the support profile blades, the free crosssection is always the same size. Accordingly, when the blades are adjusted, the pressure loss and sound power level remain constant. An adjustment of the air outflow direction at a later stage is possible at any time, even when the diffuser has already been fitted. PA: The ventilation grille type PA has front side fitted horizontal, fixed profile blades to direct the air. According to the desired air throw pattern, the blade profiles can be selected from three different profiles (PA, PAS or PAZ). According to DIN EN 60335-1, an all-pole disconnecting device must be provided by the customer, 11/02-3

Construction Diffuser DBB-A 525/215 - Faceplate made of sheet steel painted to RAL 9010 (white) with plastic blades painted to a colour similar to RAL 9005 (black) or RAL 9010 (white). Diffuser DSC-404 - Length 500 mm, front cover made of aluminium anodised or painted to RAL 9010 (white) with plastic blades painted in a colour similar to RAL 9005 (black) or RAL 9010 (white), both sides with end pieces. Diffuser DSX-XXL-W-P-3 - Length 500 mm, front cover made of aluminium anodised or painted to RAL 9010 (white) with plastic blades painted in a colour similar to RAL 9005 (black) or RAL 9010 (white), both sides with end pieces. Diffuser KG 8 515/115 - Front frame with visible screw mounting (SM) made of galvanised sheet steel, painted to RAL 9010 (white), natural colour anodised aluminium or stainless steel 1.4301 (V2A) with pivoting horizontal air deflection blades and integrated hit-and-miss damper to regulate the air volume. Diffuser KG 15 515/115 - Front frame with visible screw mounting (SM) made of galvanised sheet steel, painted to RAL 9010 (white), natural colour anodised aluminium or stainless steel 1.4301 (V2A) with pivoting vertical air deflection blades and integrated hit-and-miss damper to regulate the air volume. Diffuser PA 1 525/75 - Front frame and blades made of aluminium extrusion profiles natural colour anodised (E6/EV1) with front side horizontal stationary profile blades. Diffuser PA 2a 525/75 - Front frame and blades made of aluminium extrusion profiles natural colour anodised (E6/EV1) with front side horizontal stationary profile blades, additionally with vertical, individually adjustable droplet-forming blades. Filter - Pocket filter G2 (EU2) Housing Deflection sound absorber housing - Insulation material, building material class B1 to DIN 4102 Fan - Cross flow fan housing - Plastic impeller Heat exchanger - 2-pipe circuit frame - Aluminium blades - Copper pipes Model CULTRA Accessories Quick selection - Recirculating air module with air intake and outflow grilles, deflection sound absorber, fan, filter and cooling and/or heating register. Room acoustic module (Audimin) - Brochure on request V ZU at 35 db(a)* m 3 /h l/s CULTRA-DSC 404 125 35 CULTRA-DSX-XXL-W-P-3 200 56 CULTRA-DBB 525/215 200 56 CULTRA-KG 8 515/115 250 69 CULTRA-KG 15 515/115 250 69 CULTRA-PA 2a 525/75 250 69 *valid for a minimum height of 2000 mm. Lower heights increase the noise level. 11/02-4

Models and dimensions Dimensions CULTRA Air outflow grille Detail X CULTRA-DBB-A 525/215 CULTRA-DSC -404 Profile on site CULTRA-DSX-XXL-W-P-3 Cultra-PA 2a 525/75 Air outflow grille CULTRA-KG8 515/115 CULTRA-KG15 515/115 Air intake grille Detail Y CULTRA-KG8 515/115 CULTRA-KG15 515/115 Air intake grille CULTRA-PA 1 525/75 Possible diffusers: Air outflow grille Detail X Air intake grille Detail Y - DBB-A - KG 8 - DSC-404 - KG 15 - DSX-XXL-W-P-3 - PA 1 - KG 8 - KG 15 - PA 2a Assembly detail View A on-site on-site RO = Inspection opening When ordering, specify room height (RH)! 11/02-5 on-site

Water connection / electric connection top right (OR) Technical data Cooling capacity / Volumetric flow top left (OL) at: room temperature t R = 27 C return flow temperature t r = 19 C supply temperature t v = 16 C relative humidity = 46% when cooling at t v /t r = 16/19 C, the temperature does not drop below the dew point temperature, i.e., no condensate is formed. The device is only suitable for dry cooling. Heat exchanger: Fan Max. cooling capacity 880 W Voltage 230 V AC / 50 Hz relative humidity 46% Power 94 W Mass flow 222 kg/h max. volumetric 250 m 3 /h Pressure loss 0.082 bar flow (V max ) Water supply/return 16/19 C Air intake 27 C Air outlet 18 C Water connection 12 mm / 1/2 bottom left (UL) Standard bottom right (UR) Heating capacity at: Water supply/return 40/30 C: approx. 1250 W Radiated noise Sound power level in db at 250 m 3 /h Sound power L=33 db(a) Valid for a minimum height of 2000 mm. Lower heights increase the noise level. Cooling capacity at: t R = 27 C: max. 880 W Hz 125 250 500 1000 2000 4000 8000 db 41 36 33 26 17 12 10 11/02-6

Legend V (m 3 /h) = Volumetric flow V [l/s] = Volumetric flow Q K (W) = Cooling capacity Q H (W) = Heating capacity Q ges (kw) = Total capacity t r ( C) = Return flow temperature t v ( C) = Supply temperature t R ( C) = Room temperature Order details Fan coil unit type CULTRA Height (2000-2500m) Electric connection UL UR OL OR Water connection UL UR OL OR Air intake grille KG 8 515/115 KG 15 515/115 PA 1 525/75 Air outflow grille DBB-A 525/215 DSC-404 including end DSX-XXL-W-P-3 one-way throw including end pieces KG 8 515/115 KG 15 515/115 PA 2a 525/75 Accessories: Transformer for 3-speed circuit Actuator for Control valve Room controller Control valve Faceplate painted to RAL 9010 Order example: Cultra-2300-UL-UL-PA1-DBB/A Unless stated otherwise, the thick-frame model will be delivered! Attention! When ordering the units, the colour of the air intake grilles and air outflow grilles must be specified separately. Standard colour is RAL 9010 11/02-7

Specification texts Ready-to-insert room air-conditioning module for offices, medical practices, etc., for cooling or heating. The dimensions have been adjusted to the modular dimensions of lightweight partition walls. For installation in walls, ceilings or floors or for infront-of-the-wall installation. Easy to install and uninstall when room utilisation changes. Structure-borne noise transmission is prevented by means of a sound-decoupled suspension. A simple filter change due to an easy disassembled suction grille. For inspection purposes, quick and easy to open by means of a removable lock without requiring special tools. Optional control via 3-speed circuit or as a function of room temperature via room temperature sensor. Product: SCHAKO type CULTRA-... Room height m - Electric connection: - bottom left (UL) (standard) - bottom right (UR) - top left (OL) - top right (OR) - Water connection: - bottom left (UL) (standard) - bottom right (UR) - top left (OL) - top right (OR) Air intake grille type:... from SCHAKO - KG 8: size 515/115 mm (BxH), with pivoting horizontal air deflection blades. With integrated hit-and-miss damper for air volume regulation. With visible screw mounting (SM). - Front frame, air deflection blades and hit-and-miss damper, front side painted to RAL 9010 (white) - Aluminium natural colour anodised E6/EV1 - Stainless steel 1.4301 (V2A) - KG 15: size 515/115 mm (BxH), with pivoting vertical air deflection blades. With integrated hit-and-miss damper for air volume regulation. With visible screw mounting (SM). - Front frame, air deflection blades and hit-and-miss damper, front side painted to RAL 9010 (white) - Aluminium natural colour anodised E6/EV1 - Stainless steel 1.4301 (V2A) - PA 1: size 525/75 mm (BxH). Front frame made of extruded aluminium profile natural colour anodised (E6/EV1). With front side horizontal stationary profile blades made of extruded aluminium profiles natural colour anodised (E6/EV1). Blade profile: PA. With concealed mounting (VM 12). 11/02-8

Air outflow grille type:... from SCHAKO - DBB-A-Z: size 525/215 mm (BxH). Sheet steel faceplate painted to RAL 9010 (white). With visible screw mounting (SM). - with pivoting air deflection blades individually adjustable - plastic, similar to RAL colour 9005 (black) - plastic, similar to RAL colour 9010 (white) - Aluminium painted to the same RAL colour as the frame profile Subsequent adjustment of blades not possible. - PA 2a: size 525/75 mm (BxH). Front frame made of extruded aluminium profile natural colour anodised (E6/EV1). With front side horizontal stationary profile blades made of extruded aluminium profiles natural colour anodised (E6/EV1). Blade profile: PA. Additionally with vertical, separately adjustable dropletforming blades. With concealed mounting (VM 12). - DSC 404: 4-slot, length 500 mm. Front cover made of aluminium natural colour anodised (E6/EV1) or aluminium painted to RAL 9010 (white) With end pieces on both sides - with pivoting air deflection blades in support blade profile shape - plastic (hard PVC), similar to RAL colour 9005 (black, standard) - plastic (hard PVC), similar to RAL colour 9010 (white) or - Aluminium painted to the same RAL colour as the frame profile Subsequent adjustment of blades not possible. - DSX-XXL-W-P-3: 3-slot, length: 500 mm, one-way throw Front cover made of aluminium natural colour anodised (E6/ EV1) or aluminium painted to RAL 9010 (white) Blades made of plastic, similar to RAL colour 9005 (black) or RAL 9010 (white). With end pieces on both sides. - KG 8: size 515/115 mm (BxH), with pivoting horizontal air deflection blades. With integrated hit-and-miss damper for air volume regulation. With visible screw mounting (SM). - Front frame, air deflection blades and hit-and-miss damper, front side painted to RAL 9010 (white) - Aluminium natural colour anodised E6/EV1 - Stainless steel 1.4301 (V2A) - KG 15: size 515/115 mm (BxH), with pivoting vertical air deflection blades. With integrated hit-and-miss damper for air volume regulation. With visible screw mounting (SM). - Front frame, air deflection blades and hit-and-miss damper, front side painted to RAL 9010 (white) - Aluminium natural colour anodised E6/EV1 - Stainless steel 1.4301 (V2A) 11/02-9