Compact Ultra Low Temperature Chamber

Similar documents
Faster Temperature (& Humidity) Chamber

Faster Temperature (& Humidity) Chamber

Environmental Stress Chamber AR series

Bench-Top Type Temperature (& Humidity) Chamber

Thermal Shock Chamber TSE 11

Bench-Top Type Temperature (& Humidity) Chamber

Performance. TCC-150 provides uniform temperature load, and highlyrepeatable temperature change rate. Conformity to JEDEC JESD22-A104-B standard test

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation

Liquid to Liquid Thermal Shock Chamber TSB 21 TSB 51

Thermal Shock Chambers

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Compact design for personal use Ready to network with your computer.

Utility. High performance by special glass. Supports high-temperature, high-humidity testing

Thermal Shock Chambers

Series of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities.

Walk-In Type Temperature (& Humidity) Chamber E Series

Utility. Improved functionality and ease-of-use for bias testing. The chamber interior is formed for easier specimen loading

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Walk-In Type Temperature (& Humidity) Chamber E Series

Highly Accelerated Stress Test System (HAST Chamber)

Environmental Stress Chamber

Thermal Shock Chambers TSA Series

Battery Charge/Discharge Test System Integrated with Temperature Chamber

Environmental Stress Chamber

Temperature Cycling Chambers Global-N Series

Platinous J Series CAT.NO.E15110-Y1612

The best test chambers...

Advanced Test Equipment Rentals ATEC (2832) Temperature Cycling Chambers Global-N Series

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Temperature Chamber Series

The best test chambers...

Benchtop Test Chambers. Temperature and Humidity

Platinous. temperature. and humidity. chambers. Top Quality Design. With an Easy-to-use. Touch-Screen. Programmer

Temperature Chamber Series

Environmental Chambers

Chapter 8 Troubleshooting

Chapter 8 Troubleshooting

Technical Specification of High and Low Temperature Altitude Test Chamber

Constant climate chambers

Constant climate chambers

Benchtop Test Chambers Temperature and Humidity

Constant climate chamber with humidity

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Remote Conditioners. RC-Series. ZPRC Series

Constant climate chamber with ICH-compliant illumination

Altitude Chambers.

Chapter 5 Inspection and maintenance

Remote Conditioners. RC-Series. ZPRC Series

Synergy Controller Application Note 125 January 2016, Revision A Tidal Engineering Corporation 2016

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Chapter 7 Troubleshooting

Reproducible Climate...

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Benchtop & Compact Test Chambers

Constant climate chambers

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Customized Industrial Products

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

ENVIRONMENT FRIENDLY CLIMATIC CHAMBER

Environmental Chambers

more than M A N U FA C T U R I N G F R E E Z E R S U LT

IndigoVision Alarm Panel. User Guide

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Refrigerated Incubator Model and Operating Instructions

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

KMF Environmental test chamber for constant climate

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER


Environmental.

AIRSYS-P-SC-MOBILECOOL-INDOOR-E1507V01.2 MOBILECOOL-INDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.4~13.

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

EasyLog Data Logger Series

Constant climate chambers

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

EasyLog Data Logger Series

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Specifications Minimum Typical Maximum Unit

ThermoControl 0 C - 10 C - 20 C - 30 C

PSE-367C. AL4000 SERIES 100mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

Sunrise the beginning of a brand new day

EL-USB-TC Thermocouple Data Logger with USB Interface

Environmental simulation chamber for complex alternating climate profiles

CoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor

Added password for IP setup page : Password must be in IP format!

HOBO U14 Data Logger User Manual

EL-USB-1-LCD Temperature Data Logger with LCD

DataSheet. Thermocouple Logger

Walk in Freezer. Comfortable work environment

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

TCC-34. Features: TISSUE CULTURE

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

Constant climate chambers

Refrigerated Incubators / Environmental Testing Chambers

Transcription:

Compact Ultra Low Temperature Chamber MC-712R 812R CAT.NO.E14140-Z1804

High performance and reliability come in a compact package, covers wide range of temperature testing needs, from ultra-low temperature -85 C to high temperature +180 C. Thanks to N-Instrumentation, now it s available Ethernet connection, which allows you to control and monitor the chamber remotely, from a pc via web browser. The new designed 36 percent larger square shape frost free window, made from multi layer glass with heater gives you superior visibility. MC-812R 1

Characteristics Wide temperature range Two models are available: a chamber with a temperature range from -85 C to +180 C and a chamber with a temperature range from -75 C to +100 C. They can be used for various purposes including temperature characteristic testing and low temperature storage testing. Remote monitoring and control (Ethernet connection) By adding optionally available Ethernet Port (LAN Port), you can connect the chamber to your local area network. By doing so, you can control and monitor the chamber from any computer on the network, using a web browser. You can program test patterns, start and stop the operation without you actually being at the site. * This operation can only be performed when the power breaker is ON Test area Using sampling data Sampling data (temperature set point and process value) can be copied via a USB memory device or recorded directly. It is also possible to copy program patterns between chambers without using a PC, enabling effective use of data. * USB memory is not included. Program copy and computer editing Copy USB memory port Editing program patterns and displaying graphs The program patterns registered in the test chamber can be edited via web browser and sampling data can be displayed as graphs. Using the PC application software Pattern Manager Lite *, program patterns on a PC can be edited, displayed as graphs or output as CSV data even if offline. Web browser Program editing Edit Graph display * The Pattern Manager Lite software can be downloaded from the Test Navi website. See page 4. 2

Characteristics Tabbed user interface Provides high resolution and fast display. Tabs at the bottom of the screen make it easy to activate any section. Register test patterns Up to 40 program operation setting with maximum of 99 steps and 3 constant operation settings can be registered. Information Trend graph output Trend graphs are displayed in the screen and recorded in the internal memory according to set conditions. Data can be also recorded directly onto USB memory for backup purposes. Measurement intervals and other conditions are capable to change. Information The information section shows information on the chamber status. Messages displayed according to operating timer inform you of maintenance checks. It is also possible to register and use additional notification items. Supported languages A simple operation changes display text to English or Russian. N-Instrumentation Operating mode Constant operation, program operation, (Optional) remote operation, stop Setting range Constant setup Program setup 3 patterns 40 patterns (99 steps per program) Language External memory function I/O Web function (Optional) English, Russian (switch without restarting) Interface USB 2.0 standard compliant (A-type connector) Supported functions Write log, Read/Write program (application software: Pattern Manager Lite), write backtrace Interface RS-485 Interface Ethernet port (100base-TX) Web application Monitor, setting operation, data collection, e-mail notification Browser Windows Internet Explorer 10 3

Characteristics Backtrace function When the chamber stops because of trouble, the operation status just before the chamber stops is automatically recorded and saved. Saved data can be transferred by USB memory. E-mail the data to ESPEC, and to be provided troubleshooting. Download test profiles from Test Navi ESPEC s reliability test information website, Test Navi complies with various test standards for environmental testing. It is possible to download program patterns of various test standards and paste them on to your chamber, or edit them using the Pattern Manager Lite. ( 別売 ) Backtrace setting Test Navi (http://www.test-navi.com/eng/index.html) インターネット This website provides practical knowledge on environmental testing that ESPEC has acquired through years of experience, as well as covering everything from the fundamentals to the latest information on environmental and reliability testing. Product registration membership Website Download Pattern Manager and WEB manager information. イントラネット Download Updates for product software Search for environmental test standards Environmental Test Standards For Pattern Manager Lite Test methods download Download test profiles from a list of environmental test standards ESPEC OnlineCore Internet Test area A (Sold separately) Central control system recommended for multiple environmental test chambers installations Offices Intranet Test area B Test chambers of other manufacturers Measuring instrument Network camera *Please contact ESPEC for more information, about which products can be connected. 4

SPECIFICATIONS Model MC 712R MC 812R System Performance *1 Heater Cooler Balanced Temperature Control system (BTC system) Temp. range 75 to +100 C ( 103 to +212 F) 85 to +180 C ( 121 to +356 F) Temp. fluctuation Temp. gradient / Temp. variation in space Temp. rate of change Temp. extreme achievement time * 2 Refrigeration system Refrigerator Expansion mechanism Fittings Capacity Inside dimensions Outside dimensions * 3 Weight Power supply 200V AC 3ø 3W 50/60Hz 220V AC 3ø 3W 60Hz 380V AC 3ø 4W 50Hz Allowable ambient conditions ±0.5 C 4.0 C Heat up rate: 7.0 C /min. Pull down rate: 1.7 C /min. Heat up time: +20 +100 C Approx. 20 min. Pull down time: +20 70 C Approx. 60 min. Nichrome-strip wire heater 1 kw Plate-fin cooler ±0.5 C: at 85 to +100 C ±1.0 C: at +100.1 to +180 C 4.0 C: at 85 to +100 C 8.0 C: at +100.1 to +180 C Heat up rate: 5.5 C /min. Pull down rate: 2.2 C /min. Heat up time: +20 +180 C Approx. 30 min. Pull down time: +20 80 C Approx. 70 min. Mechanical cascade refrigeration system (air-cooled condenser) Hermetically sealed compressor (R404A/ R508A) Capillary tube system Viewing window (W107 H120 mm with frost prevention heater), Cable port (ø50 mm 1), Power cable (about 3.0 m), Drain tube (0.5 m), USB memory port, Specimen power supply control terminal, RS-485 interface 12A 12A 64L W400 H400 D400 mm (W15.7 H15.7 D15.7 in.) W900 H1200 D610 mm (W35.4 H47.2 D24.0 in.) 165kg 14A 14A 8.3A 9.2A 0 to +40 C *1 The performance values are based on IEC60068-3-5;2001, JTM K07;2007 for ambient temperature +23 C, related humidity 65%rh, rated voltage, and no specimen. *2 Temperature extreme achievement time accuracy is within Max. +10% due to power frequency change. *3 Excluding protrusions. ACCESSORIES Shelf (stainless)... 2 Shelf brackets (stainless)... 2 sets Cable port rubber plug (ø50 mm)... 1 Chamber lamp... 1 Glass tube fuse... 1 (250V AC 3A), 2 (250V AC 5A) Thermal fuse... 1 User s manual (CD)... 1 SAFETY DEVICES Leakage breaker for power supply (for 200/220V AC only) Circuit breaker (for 380V AC only) Control circuit overload & short circuit protective fuse System error Room temperature compensation burnout detection circuit. Dry bulb temperature burnout detection circuit Temperature switch for air circulator Thermal fuse Refrigerator overload relay SSR overload & short circuit protecting circuit breaker Reverse prevention relay Temperature switch for compressor Refrigerator automatic delay circuit (built inside temperature controller) Absolute upper/lower temperature limit alarm (with built-in temperature controller) Overheat protector Temperature upper limit deviation alarm Specimen power supply control terminal Electrical compartment door switch 5

OPTIONS Power cable I/O Interface Recorder Select one instead of the standard 3 m cable. 5 m 10 m * Excluding 380V AC. Communication ports to connect the chamber to a PC. RS-232C GPIB RJ23 6 dots 100 to +100 C RJ25 6 dots 100 to +200 C Temperature recorder wiring Additional cable port Provided in addition / replacement of the standard cable port (left side, ø50 mm). Available location: Left side Ceiling Available dimensions: ø25 mm ø50 mm ø100 mm * Comes with a rubber plug and a cap. Cable port rubber plug Prevents air leakage from the cable port. 50 mm Communication cables RS 485 GPIB Paperless recorder 5 m / 10 m / 30 m 2 m / 4 m A temperature recorder that utilizes a liquid-crystal display fitted with a touch-panel. Display: 5.7inch color touch panel Scan interval: 5 sec. (default) Internal recording media: Flash memory 8MB External recording media: CF memory card (Supplies with a 256 MB CF card) USB flash drive < Temperature type > No. of input channel: Temperature 1 (5 more channels can be turned ON) Preparation of a power cable, temperature sensor and a grounding wire for recorder installation in the future. Thermocouple For measuring specimen temperature Thermocouple type T (Copper/Copper-Nickel) 2 m 4 m 6 m Alarm output terminal If the safety device of the chamber is activated, external alarm terminal will notify it to a remote point. Emergency stop pushbutton Stops the chamber immediately. * Excluding 380V AC. Shelf / Shelf bracket Equivalent to standard accessory. Caster Installed for mobility. 4 casters, with leveling feet Web function Ethernet port Shelf It is an embedded server solution that allows monitoring and programming chamber via any computer, tablet computer, or other terminal. Safety precautions Do not use specimens which are explosive or flammable, or which contain similar substances. To do so could be hazardous, as this may lead to fire or explosion. Do not place corrosive substances in the chamber. If corrosive substances are generated by the specimen, the life of the chamber may be significantly shortened specifically because of the corrosion of stainless steel and copper and because of the deterioration of resin and silicon. Do not place living beings or substances that exceed allowable heat generation. Be sure to read the user s manual before operation. Some photographs listed in this catalog contain Japanese display. 6

http://www.espec.co.jp/english Head Office 3-5-6, Tenjinbashi, Kita-ku, Osaka 530-8550, Japan Tel : 81-6-6358-4741 Fax : 81-6-6358-5500 ESPEC NORTH AMERICA, INC. Tel : 1-616-896-6100 Fax : 1-616-896-6150 ESPEC EUROPE GmbH Tel:49-89-1893-9630 Fax:49-89-1893-96379 ESPEC ENVIRONMENTAL CHAMBERS SALES AND ENGINEERING LTD. STI. Tel:90-212-438-1841 Fax : 90-212-438-1871 ESPEC ENVIRONMENTAL EQUIPMENT (SHANGHAI) CO., LTD. Head Office Tel : 86-21-51036677 Fax : 86-21-63372237 BEIJING Branch Tel : 86-10-64627025 Fax : 86-10-64627036 GUANGZHOU Branch Tel : 86-20-83317826 Fax : 86-20-83317825 SHENZHEN Branch Tel : 86-755-83674422 Fax : 86-755-83674228 SUZHOU Branch Tel : 86-512-68028890 Fax : 86-512-68028860 TIANJIN Branch Tel : 86-22-26210366 Fax : 86-22-26282186 XI AN Branch Tel : 86-29-88312908 Fax : 86-29-88455957 CHENGDU Branch Tel : 86-28-88457756 Fax : 86-28-88474456 ESPEC TEST TECHNOLOGY (SHANGHAI) CO., LTD. Tel : 86-21-68798008 Fax : 86-21-68798088 ESPEC ENGINEERING (THAILAND) CO., LTD. Tel : 66-3-810-9353 Fax : 66-3-810-9356 Quality Management System Assessed and Registered ESPEC CORP. has been assessed by and registered in the Quality Management System based on the International Standard ISO 9001:2015 (JIS Q 9001:2015) through the Japanese Standards Association (JSA). *Registration : ESPEC CORP. (Overseas subsidiaries not included) Environmental Management System Assessed and Registered ESPEC CORP. (Overseas subsidiaries not included) Specifications are subject to change without notice due to design improvements. TS5B30C02 (The contents of this catalog is as of April, 2018.) Corporate names and trade names mentioned in this catalog are trademarks or registered trademarks.