Industrial and collective. With coil exchanger. Technical data. Initial heat-up. surface area. Exchanger. Exchanger capacity.

Similar documents
=Classic range= Classic range technologies. Magnesium anode. Sheathed heating element

BF1 GLASSLINED CYLINDERS WITH REMOVABLE STAINLESS STEEL HEAT EXCHANGER ( LITRES)

ALFÉA EXCELLIA DUO. more. less AIR TO WATER HEAT PUMP

BF2 GLASSLINED CYLINDERS WITH TWO REMOVABLE STAINLESS STEEL HEAT EXCHANGERS ( LITRES)

Solar Thermal Energy

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

Precision Storage Vessels ELECTRIC WATER HEATERS

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

HEAT TRANSFER STORAGE CALORIFIERS EC SERIES SC SERIES BT SERIES

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

VERTINOX. AISI 316 stainless steel accumulators with one or two heat exchangers, fixed or removable type

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS, for the User and the Installer. SMART Line. Smart ME A Y2000 B

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

HT V2 HT Split

INDEPENDENT DOMESTIC CALORIFIERS

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

DRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability.

C Tahiti. condensing

Broag Pressurisation equipment

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

Commercial Hot Water Solutions Ltd.

Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Sweden s leading air source heat pump

CALORIFIERS (Energy Storage Tanks) for domestic, commercial and industrial applications.

Flamco. Water heaters, storage tanks and accessories DUO WATER HEATER SUPASTOR WATER HEATER LS STORAGE TANKS WATER HEATERS, STORAGE TANKS

Water Heaters. Solar Applications

Technical Data Manual Model Nos. and pricing: see Price List

Series 1000 & Storage Water Heaters

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

Screw plug immersion heaters

B 150p to B 500p. Independent domestic hot water tanks. Installation instructions. Instructions for use. Technical instructions.

Installation, Operating and Servicing Instructions

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

Hoval Cosmo Combination boilers. High efficiency heating combined with economic DHW generation. Boiler outputs from 100 to 1450kW.

RENEWABLE ENERGY THERMAL SOLAR ENERGY. RENEWABLE ENERGY...pag. 05

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

Installation, Operating and Servicing Instructions

UNVENTED WATER HEATERS. Water Heater Display Stand

GENERAL CAPABILITIES

SMART Line Smart E

Condensing, pre-mixed, wall-hung gas boilers with water tank

Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

Installation Manual STOR C. Solar combination storage cylinder. Installation Manual

Electric Water Heaters. The STRENGTHS of the product range in detail:

Gasketed and brazed plate heat exchangers

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Germany 44% Spain 9% Italy 9% France 8% Austria 7% Greece 6% Poland 2% Belgium 2% Portugal 2% Switzerland 2% Great Britain 2% Cyprus 2%

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

USER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

smart line E SLE

Solar heating systems

Indirect-Fired Water Heaters

Hoval SR-plus heating boilers Outputs from 350 to 4000kW Working pressures to 8 bar

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

DEMK Series Diko Electrical Equipments Ind. and Trade Corp.

PRODUCT CATALOGUE

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

ECOplus Solar Cylinder

For commercial & industrial systems. Large volume dirt collection capacity

Pro-Clean Stratified Tank scope of delivery:

Technical Data Manual Model Nos. and pricing: see Price List

BM2 patent NEW INFRARED OIL HEATER FIRE 45

MAXIMISER Semi-Storage Calorifiers

THERMAL STORE MAINS PRESSURE SYSTEM

Hamworthy. Powerstock. Calorifiers and Storage Tanks Single and Twin Coils Capacities 160 litres to 995 litres

Indirect-Fired Water Heaters

Tubular Industrial Process

BSC...E - BSP...E - BESC...E

GAS ABSORPTION HEAT PUMP

TERMO Combi Cylinder TECHNICAL INFORMATION

( )

(770) wwww.southgateprocess.com

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

JASPI GTV & Oval thermal storage

H o t Wa te r Syste m s. Copper Hot Water Products. Exceeding the Standard

MANUFACTURER OF HEATING ELEMENTS

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

INDIRECT WATER HEATERS

UNVENTED STAINLESS STEEL CYLINDERS

Xcel HEATBANK Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

Catalogue ENGLISH h i g h h e a t t e c h n o l o g y

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Tubular Industrial Process

IMMERSION HEATERS IMMERSION HEATERS FOR WATER 1½ BRASS NIPPLE, 3X400V: 2 BRASS NIPPLE, 3X400V:

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

Indirect Fired Water Heater

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

JÄSPI Solid Fuel Boiler

Recourse to the italian Law - SIENA COURT in case of controversy shall apply.

D O M E S T I C Solar Thermal

HEATBANK Xcel Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

Transcription:

Industrial and collective Calorifiers and Combi With coil A compact, safe solution for producing hot water from multiple energy sources, including solar energy. Operation Semi-instantaneous hot water production tanks featuring an optimised coil that fully heats the tank and provides a stable temperature when water is drawn. The tanks can operate from two sources of energy, primary fluid in the winter and electricity in the summer, for example. Technical characteristics - Securex mineral lining (anti-corrosion and anti-perforation) - Sanitary working pressure: 7 bars (testing pressure at 12 bars), primary service: 4 bars - Maintenance cover as standard (dia. 150) - M1, M0 flexible jacket or metal jacket with polyurethane foam insulation - Steel RST 235 tank - Bottom dome drain 50/60 Additional characteristics for the Se Combi water heaters - Sheathed elbow heating element (Incoloy 800) to fully heat the tank (no lukewarm area at the bottom of the tank that could encourage bacterial growth) - Control thermostat with thermal cut-out safety device Technical data output (1) (kw) surface area (m²) capacity Load loss (mbar) Initial heat-up time (2) (hour) 1 st hour Flow at 60 C (3) 500 Se 43.5 1.06 7 50 1 1464 1064 726 - - 3.7 7 500 Se Combi 43.5 1.06 7 50 1 1464 1064 726 5 6h30 3.7 7 Continuous (L/h) In 10 minutes Sheathed heating element output (kw) Heat-up time (4) (hour) Energy consumption in kwh/24h Steel jacket Flexible jacket (1) primary = 90 C, flow 2m 3 /h secondary = C/W 10 C, H/W 45 C (2) from 10 to 60 C, primary = 90 C/ 2m 3 /h (3) primary = 90 C, flow 2m 3 /h storage at 65 C (4) from 15 to 65 C Please consult us if you require other outputs. Applications Hotels Residential buildings Gyms Cafeterias Hospitals Barracks Industries Any installation with large requirements for hot water

500 litres Se and Se Combi 33 max. 1826 100 1469 950 690/695 300 104 375 300 Sheathed heating element (combi) or 720/750 or 45 860 Coil Built-in Tank-heater version M26/34: Cold water inlet/hot water outlet M26/34: Optional socket for loop-back connection F26/34: Main circuit M15/21: Socket for adapting a thermostat to control the main circulation pump M26/34: Siphon draining For combi water-heaters only F15/21: Thermometer socket F15/21: Adaptation socket for additional safety thermostat Electric heating element

Industrial and collective Calorifiers and Combi Removable/removable mixed 750- to 3000-l range simple version with tubular and mixed version with tubular and sheathed heating element for full heating of the tank capacity. Operation For the tank-heater version, heating is provided all the year round by one source of energy: primary fluid. For the combi water heater version, water can be heated from 2 sources of energy (primary fluid and electricity). In winter, the heats the water from energy obtained from the primary source. In summer, water is heated by the electric heating element (the boiler is shut down). Technical characteristics - Removable with a set of AISI 304 stainless steel tubes - Securex mineral lining (anti-corrosion and anti-perforation) - Working pressure: 7 bars and testing pressure: 12 bars - In the primary pressure circuit: tubular : 10 bars, temperature: 100 C - Bottom dome drain 50/60 - Thermometer connections for loop return and thermal cut-out adaptation - Maintenance cover thanks to the 150- or 200-mm diameter flange depending on the model Additional characteristics for the combi - Sheathed elbow heating element (Incoloy 800 type) for completely heating the water above 60 C - Control thermostat with thermal cut-out mechanism to be connected to a power switch (not supplied) for outputs greater than 5 kw. Applications Hotels Residential buildings Gyms Cafeterias Hospitals Barracks Industries Any facility requiring large amounts of hot water

Technical data heat-up Load Flow at 60 C** In 10 Capacity output time surface loss capacity 1 st hour 1n 1 hour minutes (kw) (hour*) area (mbar) (L/h) (L/h) 750 22 2h 0.76 20 3.5 978 378 663 1000 22 3h 0.76 20 3.5 1178 378 863 1500 30 3h 1 20 4.2 1715 515 1286 2000 30 4h 1 20 4.2 2115 515 1686 2500 44 3h30 1.71 20 6.5 2756 756 2126 3000 44 4h 1.71 20 6.5 3156 756 2526 * primary: 2m 3 /h at 90 C, secondary: 10 to 60 C ** primary: 2m 3 /h at 90 C, secondary: EF 10 C, storage at 60 C Combi version Sheathed Initial Energy consumption in Capacity heating element heat-up time kwh / 24h output (kw) (hour*) Steel jacket Flexible jacket 750 10 5h45 6 4.6 1000 10 6h30 6.9 5.4 1500 15 6h30 9.2 7.2 2000 24 5h30 10.9 8.5 2500 24 6h45 12.3 9.6 3000 24 8h 14 11 * from 15 to 65 C 55 max. 750 to 3000 litres with removable Tubular Stainless steel tubular fitted on to dia. 210 flange (water primary or steam 0.5 bars) 100 100 G H G 104 H F 104 B A C F E A B C heating position version Combi version Combi or version sheathed heating element Combi version 45 P ø Cold water inlet / hot water outlet M33/42: Return loop tube Primary circuit (tubular ) F40/49: Plug for control thermostat M50/60: Drain F15/21: Plug for thermometer F15/21: Plug for additional safety thermostat Electric heating element

Industrial and collective Plate Turbot (plate ) Simple, compact and effective We have designed specific appliances to provide the continuous production of large quantities of hot water. Installed alongside a gas or fuel oil boiler, an energy recuperator or heat pump, they operate semi-instantaneously by means of a plate. The storage tank thus absorbs peaks in consumption by reducing the output of the primary energy source to be installed. Operation Semi-instantaneous production of hot water by means of a plate. Provides continuous production of hot water. Storage tank that absorbs peaks in consumption by reducing the power of the primary energy source to be installed. Technical characteristics - Steel RST 235 tank - Securex mineral lining (anti-corrosion and anti-perforation) - Working pressure: 7 bars and testing pressure: 12 bars (primary: 10 bars max., temperature: 140 C) - AISI 316 stainless steel, brazed plate - Bottom dome drain 50/60 (optional for 300 and 500 l) - Control bulb aquastat that controls the circulator pump (not supplied) of the primary circuit - Manual reset bulb thermal safety mechanism to prevent overheating if the aquastat fails - Secondary circulation pump - 3 isolating valves for maintenance and for changing the or the pump - Storage temperature thermometer - Maintenance cover thanks to the 150- or 200-mm diameter flange depending on the model - Connection for loop return. Applications Hotels from 8 to 130 rooms Residential units from 8 to 160 apartments Hospitals, etc.

Technical data Primary circuit Hot water flow Number of apartments Number of hotel rooms Capacity Flow (L/h) Load loss in m CE Output (kw) Initial heat-up time (minutes) Continuous (L/h) In 1 hour In 10 mn Normal Standing Water draw in 1 hour 3 2 or 4 Primary 70 C Secondary hot water 10 C to 55 C 300 2180 4.2 56 22 1072 1205 401 14 12 12 10 500 2940 3.8 81 25 1551 1796 633 30 24 22 17 750 3490 5.3 90 34 1723 2151 858 50 37 27 23 1000 5000 5.1 136 30 2603 3143 1190 78 62 40 34 Primary 50 C Secondary hot water 10 C to 55 C 300 2180 4.2 80 15 1531 1618 470 20 16 18 16 500 2940 3.8 115 18 2220 2381 730 40 30 30 25 750 3490 5.3 129 24 2469 2822 970 60 47 36 30 1000 5000 5.1 194 21 3714 4141 1357 93 74 52 45 Primary 90 C Secondary hot water 10 C to 55 C 300 2180 4.2 104 12 1990 2031 539 25 22 25 20 500 2940 3.8 150 14 2870 2983 831 50 39 38 32 750 3490 5.3 170 18 3250 3525 1088 77 53 45 38 1000 5000 5.1 255 16 4880 5192 1532 97 85 66 55 Dimensions Capacity Brazed plate Maintenance cover ø 150 * Only on the 300 L model * P ø 25 Dimensions (mm) Ø H A B C E F P Overall 45 E 50 H 130 C/W-H/W tubes (1 and 2) F On > 300 L External plate Turbot Plate calorifier 300 to 1000 litres Net weight (kg) Steel jacket Flexible jacket 300 640 1640 300 575 1420 430 221 750 20/27 130 95 500 750 1920 300 755 1528 485 221 860 26/34 190 170 750 900 1790 400 1000 1538 560 252 1015 33/42 240 210 1000 900 2200 400 1000 1948 560 252 1015 33/42 280 270 Handling rings A B C Cold water inlet / hot water outlet Loop return connection 33/42 Additional connection 33/42 Drain 50/60 on >300 L 15/21 MF pocket (thermometer Atlantic International SAS au capital de 61 000-17, rue Croix Fauchet - 45140 Saint Jean de la Ruelle - RCS Orléans B 390 284 693 - No contractuals photos - August 2008 - L2R