Flange Heaters Type CX

Similar documents
Screwplug Heaters. Type CX. Screwplug Heaters Type CX. Operation. Application. Selection. Terminal Block Simplifies Wiring. Warning - Fire Hazard

Flange Heaters - CX. Application. Corrosion. Watt Density. Passivation. Construction. Flange Heaters CX

SCREWPLUG HEATERS. immersion heaters

Circulation Heaters - EX

( )

OVER-THE-SIDE HEATERS. immersion heaters

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

Tubular Industrial Process

Screw Plug Immersion Heaters

Circulation Heaters Selection Guidelines

( )

Immersion Heaters. Screw Plug Immersion Heater

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

SCREW PLUG IMMERSION HEATERS

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

Tubular Industrial Process

Circulation Heaters Selection Guidelines

Flanged Immersion Heaters

Tubular Industrial Process

Flanged Immersion Heaters

Flanged Immersion Heaters

CIRCULATION HEATERS. immersion heaters

Installation and Operation Instructions. Versa. Screw Plug Oil & Water Immersion Heater. PD January 2018

( )

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Checklist Selecting the Proper Flanged Heater

Installation, Operation and. Maintenance Instructions

CF1 ProVector Explosion-Proof Heaters

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

CX1 ProVector Explosion-Proof Heaters

Thermal Devices Inc. Mount Airy, Maryland USA Process Air and Radiant. ADH Typical Installation.

electric immersion heaters

ASME Packaged Electric Water Heater

electric immersion heaters

Circulation Heaters. Standard Construction. 2 Star Electric to Order Call Terminal Box. Flanged Immersion Heater. Outlet.

Differences Among Screw Plug Immersion Heaters

Chromalox. Installation, Operation. Circulation Heaters for Oil or Water Heating RENEWAL PARTS IDENTIFICATION PE GENERAL NWH

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages

FX5 Series Explosion-Proof Electric Air Heaters

Shipboard Electric Water Heater

10-14 SECTION TUBULAR HEATERS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

Typical Applications. Braking Resistor Core Drying Dehumidification Forced Air Comfort Heating

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

Tubular Heaters Rev 4 ( ) Finned Tubular Heaters. Finned Tubular Heaters. View Product

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

Shipboard Electric Water Heater

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

Tubular Heaters Introduction. Tubular Heater Introduction. Design Guidelines. View Product

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Light Duty Commercial Electric Water Heater

Technical Information

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

Control and power circuit fusing to meet N.E.C.

STRAIGHT & FORMED TUBULAR HEATERS

Tubular Heaters Series

Brasch Hazardous Location Unit Heaters

How 1 is your resistance. wire sized? What grade of magnesium oxide is being used? How 3 is your cold pin attached to your resistance wire?

Installation, Operation, Maintenance Instructions and RENEWAL PARTS IDENTIFICATION

Description. Applications

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

Cartridge Heaters. Components. Application Guidelines

Tubular Heaters. Table Of Contents

MEGAWAT * HIGH DENSITY CARTRIDGE HEATERS

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY

Strip/Clamp-On Heaters

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

RENEWAL PARTS IDENTIFICATION. Type TTUH and TTUH-CO URN Heaters. Dimensions (In.) Extends. Model Volts kw W/In 2 A B C D

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

Industrial Flanged Immersion Heaters

Description. Construction

BRINGING WARMTH TO YOUR WORLD

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions

KUH. Horizontal Unit Heater. Applications. Description

Industry Best 10 Year Commercial Warranty

BENEFITS. Standard 2-3. HCFC S (hydrochlorofluorocarbons), CFC S (chlorofluorocarbons) nor VOC s (volatile organic compounds). Hot water.

Cast Line Heaters The Benefits of This Space Saving Electric Heater

Tankless On Demand Electric Water Heater

Residential Upright Residential Lowboy

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY

Thermostats and Accessories

ULTRA-SAFE Explosion-proof Duct Heaters

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

Unheated straight section Fast response time Choice of lead protection Longer heater life Higher watt densities Made to customer specifications

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

Hotwatt, established in 1952, began with the manufacturing of one product, the open coil heating element. Since then Hotwatt has expanded our product

CLE SERIES Fluid heating for emergency eyewash stations

ULTRA-SAFE Explosion-proof Duct Heaters

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

PROCESS HEAT PROCESS HEAT.

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

Transcription:

pplication Flange heaters are used to heat liquids or gases in tanks or in-line vessels. Safe and reliable service from the heater requires the correct selection of materials and heating element watt density. Watt Density Watt density refers to the wattage output of a heater divided by the total surface area of the heated sections of all heating elements in the heater. It is important to understand the basic thermal difference between an electric immersion heater and a steam or liquid heat exchanger. Unlike the steam or liquid heat exchanger, all of the heat produced by an electric heater will leave the heater. Even though the surface area in contact with the work is fixed, the heating element sheath temperature will continue to rise until the heat produced is equal to the heat transferred to the process. detailed understanding of this behaviour and the system parameters will allow the design of a suitable heater to heat virtually any liquid or gas with the only limitation being its ability to resist corrosion in highly active solutions. s a general rule, low watt density heaters will provide longer service life than high density heaters, especially when the fluid being heated is viscous or stagnant. However, low density heaters are initially more expensive. Corrosion Experience shows that published corrosion guidelines are based on ideal situations which may prove to be optimistic in actual practice. In some instances there is little alternative other than to accept reduced service life and keep a spare heater on hand as a standby replacement. Passivation Incoloy and stainless steel sheathed heaters are available with chemically passivated sheaths which will provide superior corrosion resistance in most applications. Passivation is achieved through an electro polishing technique. Heaters with stainless steel flanges are available with all wetted surfaces passivated. Since passivation is a relatively expensive procedure it should only be specified in highly corrosive applications and on the recommendation of the chemical supplier. 2

Wiring High amperage heaters allow staging through 45 MP subcircuits to allow the use of 50 MP definite purpose magnetic contactors on each circuit. Terminal lugs and grounding lugs are provided. Control Construction Standard heaters listed have 150 lb. NSI rated steel flanges and copper or incoloy sheathed elements silverbrazed to the flange. Most systems require some method of temperature and limit control. variety of control systems can ben provided to meet any process requirements. Heaters pictured on these introductory pages are examples of some of the custom heaters produced to meet special process requirements. Moisture and Sealing Standard flange heaters have unsealed heating element ends and utilize magnesium oxide for both electrical insulation and heat transfer. Magnesium oxide in contact with the atmosphere will hydrate... absorb moisture, lowering the insulation resistance of the heater. On start-up, this often results in small leakage currents which pose no hazard to operating personnel or equipment in properly grounded systems. However, these currents may be sufficient to trip a ground fault interruptor (G.F.I.) and shut down the system. General procedure is to by-pass the G.F.I. until the heater dries itself out after a period of operation. If this is impractical, it is best to order a heater with special end seals. 3

2 1/2" Flange Heaters Selection Type CXC heaters are used primarily for heating water and have copper sheathed elements silver brazed to a steel flange. Type CXI heaters may also be used to heat water, especially in hot water and steam boilers. These heaters are also suitable for heating mildly corrosive solutions inrinse tanks, spray washers, etc. F Dia. E Holes on a C.C. G H COLD END Heaters consist of incoloy sheathed elements silver brazed to a steel flange. Type CXF heaters are constructed of similar materials to CXI heaters except that the heating elements have much lower watt densities. These heaters are especially suited to heating oils, gases and mildly corrosive liquids. Select the lower density CXF heaters for stagnant or heavy oils or for high temperature, low flow gas heating. D Dia HETER DIMENSIONS IN MM FLNGE FLNGE SIZE RTING C D E F G H 2 1/2" 150 lb. 73 140 178 4 19 22 140 300 lb. 73 149 191 8 22 25 140 TLE 1-2 1/2" - 150 L. STEELFLNGE HETERS 21/2" - 150 L. STEELFLNGE HETERS TO ORDER SPECIFY: Quantity, catalog number, voltage, phase, wattage and special features. 4

3" Flange Heaters Selection Type CXC heaters are used primarily for heating water and have copper sheathed elements silver brazed to a steel flange. Type CXI heaters may also be used to heat water, especially in hot water and steam boilers. These heaters are also suitable for heating mildly corrosive solutions inrinse tanks, spray washers, etc. Heaters consist of incoloy sheathed elements silver brazed to a steel flange. Type CXF heaters are constructed of similar materials to CXI heaters except that the heating elements have much lower watt densities. These heaters are especially suited to heating oils, gases and mildly corrosive liquids. Select the lower density CXF heaters for stagnant or heavy oils or for high temperature, low flow gas heating. F Dia. E Holes on a C.C. G H COLD END HETER DIMENSIONS IN MM FLNGE FLNGE SIZE RTING C D E F G H D Dia 3" 150 lb. 89 152 191 4 19 24 140 300 lb. 89 165 210 8 22 29 140 TLE 2-3" - 150 L. STEELFLNGE HETERS 3" - 150 L. STEELFLNGE HETERS HIGH DENSITY - COPPER SHETH HIGH DENSITY - INCOLOY SHETH MEDIUM DENSITY - INCOLOY SHETH LOW DENSITY - INCOLOY SHETH TO ORDER SPECIFY: Quantity, catalog number, voltage, phase, wattage and special features. 5

4" Flange Heaters Selection F Dia. E Holes on a C.C. D Dia G H COLD END Type CXC heaters are used primarily for heating water and have copper sheathed elements silver brazed to a steel flange. Type CXI heaters may also be used to heat water, especially in hot water and steam boilers. These heaters are also suitable for heating mildly corrosive solutions inrinse tanks, spray washers, etc. Heaters consist of incoloy sheathed elements silver brazed to a steel flange. Type CXF heaters are constructed of similar materials to CXI heaters except that the heating elements have much lower watt densities. These heaters are especially suited to heating oils, gases and mildly corrosive liquids. Select the lower density CXF heaters for stagnant or heavy oils or for high temperature, low flow gas heating. HETER DIMENSIONS IN INCHES FLNGE FLNGE SIZE RTING C D E F G H 4" 150 lb. 5 7 1/2 9 8 3/4 15/16 5 1/2 300 lb. 5 7 7/8 10 8 7/8 1 1/4 5 1/2 TLE 3-4" - 150 L. STEELFLNGE HETERS 4" - 150 L. STEELFLNGE HETERS HIGH DENSITY- COPPER SHETH HIGH DENSITY- INCOLOYSHETH MEDIUM DENSITY- INCOLOYSHETH LOW DENSITY- INCOLOYSHETH TO ORDER SPECIFY: Quantity, catalog number, voltage, phase, wattage and special features. 6

5" Flange Heaters Selection Type CXC heaters are used primarily for heating water and have copper sheathed elements silver brazed to a steel flange. Type CXI heaters may also be used to heat water, especially in hot water and steam boilers. These heaters are also suitable for heating mildly corrosive solutions inrinse tanks, spray washers, etc. Heaters consist of incoloy sheathed elements silver brazed to a steel flange. Type CXF heaters are constructed of similar materials to CXI heaters except that the heating elements have much lower watt densities. These heaters are especially suited to heating oils, gases and mildly corrosive liquids. Select the lower density CXF heaters for stagnant or heavy oils or for high temperature, low flow gas heating. F Dia. E Holes on a C.C. D Dia G H COLD END HETER DIMENSIONS IN MM FLNGE FLNGE SIZE RTING C D E F G H 5" 150 lb. 127 216 254 8 22 24 172 300 lb. 127 235 279 8 22 35 152 TLE 4-5" - 150 L. STEELFLNGE HETERS 5" - 150 L. STEELFLNGE HETERS HIGH DENSITY- COPPER SHETH HIGH DENSITY- INCOLOYSHETH MEDIUM DENSITY- INCOLOYSHETH LOW DENSITY- INCOLOYSHETH TO ORDER SPECIFY: Quantity, catalog number, voltage, phase, wattage and special features. 7

6" Flange Heaters Selection F Dia. E Holes on a C.C. D Dia G H COLD END Type CXC heaters are used primarily for heating water and have copper sheathed elements silver brazed to a steel flange. Type CXI heaters may also be used to heat water, especially in hot water and steam boilers. These heaters are also suitable for heating mildly corrosive solutions inrinse tanks, spray washers, etc. HETER DIMENSIONS IN MM FLNGE FLNGE SIZE RTING C D E F G H 6" 150 lb. 127 241 279 8 22 25 169 300 lb. 127 270 318 12 22 37 152 Heaters consist of incoloy sheathed elements silver brazed to a steel flange. Type CXF heaters are constructed of similar materials to CXI heaters except that the heating elements have much lower watt densities. These heaters are especially suited to heating oils, gases and mildly corrosive liquids. Select the lower density CXF heaters for stagnant or heavy oils or for high temperature, low flow gas heating. TLE 5-6" - 150 L. STEEL FLNGE HETERS 6" - 150 L. STEELFLNGE HETERS HIGH DENSITY- COPPER SHETH HIGH DENSITY- INCOLOYSHETH MEDIUM DENSITY- INCOLOYSHETH LOW DENSITY- INCOLOYSHETH TO ORDER SPECIFY: Quantity, catalog number, voltage, phase, wattage and special features. 8

8" Flange Heaters Selection F Dia. E Holes on a C.C. G H COLD END Type CXC heaters are used primarily for heating water and have copper sheathed elements silver brazed to a steel flange. Type CXI heaters may also be used to heat water, especially in hot water and steam boilers. These heaters are also suitable for heating mildly corrosive solutions inrinse tanks, spray washers, etc. D Dia Heaters consist of incoloy sheathed elements silver brazed to a steel flange. Type CXF heaters are constructed of similar materials to CXI heaters except that the heating elements have much lower watt densities. These heaters are especially suited to heating oils, gases and mildly corrosive liquids. Select the lower density CXF heaters for stagnant or heavy oils or for high temperature, low flow gas heating. HETER DIMENSIONS IN MM FLNGE FLNGE SIZE RTING C D E F G H 8" 150 lb. 127 299 343 8 22 29 162 300 lb. 127 330 381 12 25 41 152 TLE 6-8" - 150 L. STEELFLNGE HETERS 8" - 150 L. STEELFLNGE HETERS HIGH DENSITY- COPPER SHETH HIGH DENSITY- INCOLOYSHETH MEDIUM DENSITY- INCOLOYSHETH LOW DENSITY- INCOLOYSHETH TO ORDER SPECIFY: Quantity, catalog number, voltage, phase, wattage and special features. 9

Pipe-Insert Immersion heaters Type MX pplication For heating asphalt, molasses, tar, paint, glue or any viscous fluids. When heating corrosive liquids the pipe enclosing the heater must be resistant to corrosion. Tank fabricator to supply and install pipes. Heater can be removed without draining the liquid. Heat is transferred safely from the heating element to the inner wall of the pipe by a combination of convection and radiation. Note that filling the pipe with a heat transfer fluid is neither required nor recommended. Construction Typical application of pipe-insert immersion heater for viscous fluids Standard heaters have heavy duty alloy sheathed element(s) fitted to either a 3" 150 Ib. steel flange or a 2"NPT screwplug. The terminal box is moisture resistant for outdoor applications. One 1" NPT conduit fitting is provided on units without thermocouple, and an additional 1/2" NPT conduit fitting is provided on units with built-in thermocouples. Heaters with Type K thermocouples (one per tank) are used for detecting low liquid levels. If the level drops below the uppermost heater, the temperature inside the heaterpipe will rise. The thermocouple will detect this temperature rise, and, when this signal is fed through an electronic temperature limit control, it will automatically trip the system off. We can provide a packaged control panel or ship the control components individually. MPE CP Liquid Level llow Space for Heater Expansion Tank Selection and Sizing Control Panel Temperature Sensor Heater Installation Install heaters in a suitable metal pipe with a 2" minimum inside diameter. Fit 3" standard pipe flanges or 2" couplings where pipes extend outside the tank wall and cap the pipe ends inside the vessel. It is best to leave one pipe a few inches higher than the others. This pipe will receive the heater with the built-in thermocouple or limit device to provide fast response under low liquid level conditions. Use the graphs and the explanation on the following page to determine the kilowatts necessary to maintain the tank at the required temperature. Next, select the required number of heaters with an insert length long enough to provide good heat distribution. Normally the one element and two element style heaters are used in groups of three so that they can be wired in a three phase balanced system. When the application entails heating an extremely viscous liquid from a cold start, the one element heater should be selected since the lower resulting watt density on the pipe surface will prevent coking (see Table). 12

Screwplug Heaters Screwplug Heaters Type CX Heaters with 1" and 1 1/4" Plugs pplication Type CXC heaters are used primarily for water heating and have brass screwplugs and copper sheaths. Type CXF are used primarily for oil heating and have steel screwplugs. Low watt density heaters are used in heavier, non-circulated oils. Higher watt density heaters are suitable for light oils or in forced oil circulation loops. Incoloy elements are silver brazed into a steel screwplug. uilt-in Thermostats Standard built-in thermostat is a one pole device limited to 240V 25 amp. Whenever the heater voltage exceeds 240V or the heater current exceeds 25 amps or for threephase supply, the thermostat is intended for pilot duty only and is not factory wired to the elements. You may uinquire contactor and control transformer you may require in these instances. TLE 1-1" NPT SCREWPLUG HETERS (ONE ELEMENT) HIGH DENSITY- COPPER SHETH / RSS PLUG MEDIUM DENSITY- INCOLOY SHETH / STEEL PLUG LOW DENSITY- INCOLOY SHETH / STEEL PLUG TLE 2-1 1/4" NPT SCREWPLUG HETERS (TWO ELEMENTS) HIGH DENSITY- COPPER SHETH / RSS PLUG MEDIUM DENSITY- INCOLOY SHETH / STEEL PLUG LOW DENSITY- INCOLOY SHETH / STEEL PLUG TO ORDER SPECIFY: Quantity, catalog number, voltage, wattage and special features. D2

Screwplug Heaters Screwplug Heaters Type CX Heaters with 2" Plugs pplication Type CXC heaters can be used for heating air, gas or liquids and can be manufactured from a variety of materials depending on the application. Type CXI heaters are used primarily for heating mildly corrosive solutions and use higher density incoloy elements welded into a stainless steel screwplug. uilt-in Thermostat Standard built-in thermostat is a one pole device limited to 240V 25 amp. Whenever the heater voltage exceeds 240V or the heater current exceeds 25 amps or for three phase supply, the thermostat is intended for pilot duty only and is not factory wired to the elements. You may require a contactor and control transformer in these instances. UNIT WITH EXPLOSION- PROOF HOUSING ND DJUSTLE THERMOSTT TLE 3-2" NPT SCREWPLUG HETERS (TWO ELEMENTS) HIGH DENSITY- COPPER SHETH (RSS PLUG) HIGH DENSITY- INCOLOY SHETH (STINLESS PLUG) TO ORDER SPECIFY: wattage, voltage and special features. D3

Screwplug Heaters Screwplug Heaters Type CX Heaters with 2" Plugs (cont d) and with 2 1/2" Plugs pplication Type CXC heaters are used primarily for water heating and have brass screwplugs and copper sheaths. Type CXF are used primarily for oil heating and have steel screwplugs. Low watt density heaters are used in heavier, noncirculated oils. Higher watt density heaters are suitable for light oils or in forced oil circulation loops. Incoloy elements are silver brazed into a steel screwplug. uilt-in Thermostats phase supply, the thermostat is intended for pilot duty only and is not factory wired to the elements. You may require a contactor and control transformer in these instances. Standard built-in thermostat is a one pole device limited to 240V 25 amp. Whenever the heater voltage exceeds 240V or the heater current exceeds 25 amps or for three TLE 3-2" NPT SCREWPLUG HETERS (TWO ELEMENTS)... continued MEDIUM DENSITY- INCOLOY SHETH (STEEL PLUG) TO ORDER SPECIFY: Quantity, catalog number, voltage, wattage and special features. D4

Screwplug Heaters Screwplug Heaters Type CX UNITWITH EXPLOSION- PROOF HOUSING UNITWITH EXPLOSION- PROOF HOUSING ND DJUSTLE THERMOSTT TLE 4-2" NPT SCREWPLUG HETERS (THREE ELEMENTS) HIGH DENSITY- COPPER SHETH (RSS PLUG) MEDIUM DENSITY- INCOLOY SHETH (STEEL PLUG) LOW DENSITY- INCOLOY SHETH (STEEL PLUG) TLE 5-2 1/2" NPT SCREWPLUG HETERS (THREE ELEMENTS) HIGH DENSITY- COPPER SHETH (RSS PLUG) HIGH DENSITY- INCOLOY SHETH (STINLESS PLUG) TO ORDER SPECIFY: Quantity, catalog number, voltage, phase, wattage and special features. TLE 5 is continued on page 8 D5

Screwplug Heaters Screwplug Heaters Type CX Heaters with 2 1/2" Plugs (cont'd) pplication Type CXF are used primarily for oil heating and have steel screwplugs. Low watt density heaters are used in heavier, non-circulated oils. Higher watt density heater sare suitable for light oils or in forced oil circulation loops. Incoloy elements are silver brazed into a steel screwplug. Type CXI heaters are used primarily for heating mildly corrosive solutions and use higher density incoloy elements welded into a stainless steel screwplug. uilt-in Thermostats UNIT WITH EXPLOSION- PROOF HOUSING ND DJUSTLE THERMOSTT Standard built-in thermostat is a one pole device limited to 240V 25 amp. Whenever the heater voltage exceeds 240V or the heater current exceeds 25 amps or for threephase supply, the thermostat is intended for pilot duty only and is not factory wired to the elements. You may require a contactor and control transformer in these instances. TLE 5-2 1/2" NPT SCREWPLUG HETERS (THREE ELEMENTS)... continued MEDIUM DENSITY- INCOLOY SHETH (STEEL PLUG) MEDIUM DENSITY- INCOLOY SHETH (STINLESS PLUG) LOW DENSITY- INCOLOY SHETH (STEEL PLUG) LOW DENSITY- INCOLOY SHETH (STINLESS PLUG) D6

Screwplug Heaters Special Features HETERS WITH UILT-IN THERMOSTTS ll screwplug heaters listed are available with built-in thermostats. Heaters with thermostats have a T added to their catalog no. prefix. Standard thermostat range is 10-120 C. Ratings are normally 25 amps at 240V single pole singlethrow. 600V thermostats and double pole thermostats are available on special order. SPECIL THERMOSTT RNGES Thermostats with the following temperature ranges are also available upon request: -18 to 40 C 70 to 280 C 150 to 370 C TERMINL HOUSINGS Shown below are the different types of terminal housings used with screwplug heaters. FIG. 1 FIG. 2 FIG. 3 FIG. 4 VOLTGE FIG. 5 Custom built heaters are available in any special voltage rating up to 600V max. SHOWN WITH OPTIONL EXTERNLLY DJUSTLE THERMOSTT WTTGE Heaters listed are standard wattage. ny reasonable wattage is available to replace your present heater with a similar unit. LENGTH Heaters are available with immersed lengths up to 3430 mm. Internal vessel support must be used when immersed length exceeds 1245 mm. PLUG SIZES ND RTINGS We can install elements in virtually any size or rating of plug, special or standard. SPECIL MTERILS Special sheath, plug and terminal box materials are available on request. WELDED ELEMENTS While welded elements are standard for CXI heaters, CXF heaters listed have the elements silver brazed to the plug which suits most applications. We can provide listed CXF heaters with elements welded to the plug. UILT-IN THERMOSTT WELL uilt-in thermostat wells are available. Specify length and internal diameter required. Heaters ordered with explosion-proof or moisture resistant housings have built-in wells as standard. PSSIVTION Incoloy and stainless steel sheathed heaters are available with chemically passivated sheaths which will provide superior corrosion resistance in most applications. Passivation is achieved through an electro polishing technique. Heaters with stainless steel plugs are available with all wetted surfaces passivated. MOISTURE RESISTNT TERMINL HOUSINGS Moisture resistant terminal housings suitable for outdoor applications are available for all heater sizes. See Figure 4. EXPLOSION-PROOF TERMINL HOUSINGS If the heater is to be operated in a hazardous environment an explosion-proof housing must be used. See Figure 5. Specify Class, Div. (or Zone), Group and Temp. for the hazardous location. D7