Underground fires in metro systems failures, accidents and terrorism

Similar documents
Crossrail Fire Safety Designs

Fire Protection and Safety in Tunnels Conference Opening Remarks. Dr Fathi Tarada Secretary, PIARC Tunnel Operations Committee

Crossrail. Clare Hebden; September 2012

Fire protection of emergency electrical devices: effect on the level of risk a case study of a rail tunnel

Hot Issues in Fire Engineering July 2014

Smoke Management in Subway Stations Due to Train Arson Fire Scenario

Comment on Hawker Stall Fires

The first tunnel fire. Benefits of fire

Rail System Ventilation Rehabilitation

FIRE RESISTANCE OF ROLLING STOCK ELEMENTS STANDARD AND SPECIAL CASE OF TUNNELS

Fire Detection and Fire Fighting Testing and Approval on Railway Vehicles

Tunnels, Risks & Design Mitigation

Washington Metropolitan Area Transit Authority (WMATA)

A Study on the People Evacuation Safety for the. Underground MRT Station

Japanese Case Study: How to maintain the fire safety in subway station and tunnel

The Train Now Arriving At... Harmonised Fire Safety For European Rolling Stock

Sprinklers Modeling for Tunnel Road Fire Fighting

CFD ASSESSMENT OF RAILWAY TUNNEL TRAIN FIRE SCENARIOS

CFD-AIDED TENABILITY ASSESSMENT OF RAILWAY TUNNEL TRAIN FIRE SCENARIOS

6B-2 6th Asia-Oceania Symposium on Fire Science and Technology 17-20, March, 2004, Daegu, Korea

4.13 Security and System Safety

Quantitative risk assessment for a fire suppression system in the New Tyne Crossing. Dr Fathi Tarada

Regulatory Reform (Fire Safety) Order 2005 Category of Premises against the FSO 2005: Sleeping Accommodation

Impact of quick incident detection on safety in terms of ventilation response

Third Runway Project APM Depot Fire Engineering Design. Presented by Ir Wilson Sau-kit TSANG

Selecting the AFUMEX range guarantees quality and offers the widest choice and the greatest safety.

Emergency Ventilation System Design - Preliminary Report Shishir Gupta

Ensuring safe passage HI-FOG for underground stations

Hot Issues in Fire Engineering 12 March 2013

FIRE RISK ASSESSMENT Retirement Housing (Independent Living) (v3.november 2016)

DMRC at a Glance. Registered : May Construction Commenced : Oct Operation Commenced : Dec Operates 213 RKM in 7 lines, 158 Stations

IFireSS International Fire Safety Symposium Coimbra, Portugal, 20 th -22 nd April 2015

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT

Increasing Fire Safety of Cologne Main Station by High Pressure Water Mist

The development of seat fire testing for EN Richard Nowell

Fire Safety in Guest Harbours and Marinas

Residential Structure Match or Lighter Ignited Fires

ITALIAN STANDARD UNI 11565

ASPECTS OF FIRE SAFETY IN ULTRA HIGHRISE BUILDINGS

Statue of Liberty: A Risk Analysis

Maintaining Schools for the future our initiative. Len Allen

Executive Review Panel Report on Arson Incident

and Sprinkler System in Resalat Tunnel of Tehran

Tampa, FL Fire Cause Classification Task Group Tue, 14 April 2011

Research Needs for the Fire Safety Engineering Profession

Provisions for the Means of Escape and Means of Access by Using Lifts and Escalators in the MTRC Main (U/G) Station

Recent European and national German regulations for. measures


International Standards and their relevance to the Modern Built Environment

Shelter and Evacuation Plan. 1.0 Purpose. Table of Contents. General Policies Revision # 0 Page # 1 of 25

New Approaches to Design for Fire Safety


Fire and smoke management in a uni-directional road tunnel for a congested traffic condition

EMERGENCY VENTILATION FOR SMOKE CONTROL IN ROADWAY TUNNELS (NCHRP PROJECT TASK 363)

Appendix SPAIN Madrid M30-Río-TUNNEL

Soil/Landfill compactor Note: It is recommended that you read the Supporting Information page before you read this factsheet.

Firefighting operations on multi-tiered vehicle stacking buildings F5-13 GD

June 2017 (Updated 18 January 2018) Fire Safety Policy. Peter Webb, Project Manager Compliance First Choice Homes Oldham Limited

Fire Safety Protocol

Vehicle Fire, Safety and Evacuation

DR J H BURGOYNE AND PARTNERS LLP FORENSIC SERVICES

Smoke Control of Fires in Subway Stations

LYHA Fire Safety Policy

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

Risk Assessment of large Hydrocarbon Storage tanks. G. Unnikrishnan, Kuwait Oil Company

Managing Fire Safety Through Construction. Reece Walker Arup Fire Engineer

VENTILATION & FIRE SAFETY

Risk Management of Fire using Video Based Detection

Why is this important?

Contingency/Emergency Plan for all Hazards Page 1 of 9

Evolution in Emergency Lighting 7 March 2018

Road tunnel safety rules in Italy: the tunnel country

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

Gerd Koffmane, Henrik Hoff, AP Sensing GmbH, Böblingen

Considerations in the Design of Smoke Management Systems for Atriums

A Study into the Standardization of Using Fire Detectors in Rail Vehicles for China

An Analysis of Compartment Fire and Induced Smoke Movement in Adjacent Corridor

To: All SAAS Accredited Certification Bodies Subject: Clarification to Emergency and Health & Safety Requirements in the SA8000 Standard

Crossrail Project. Infrastructure design and construction Volume 5. Edited by Professor Rhys Vaughan Williams and Mike Black

Research on Mobile Water Spray Device Reducing the Temperature of Metro Fire

Risk Based Approach to Cultural Heritage Buildings Prof. dr. ir. P. Vandevelde

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

A Brief on Performance- Based Design for Building Fire Safety

Yunyong P. Utiskul, Ph.D., P.E., CFEI

Slight Harm Moderate Harm Extreme Harm Low Trivial Risk Tolerable Risk Moderate Risk Medium Tolerable Risk Moderate Risk Substantial Risk

Arc Fault Detection Devices (AFDDs) Protecting People and Property

FOGTEC Rail Systems. Rolling Stock Applications. Fire Protection Solutions from one source. Leading in Fire Protection

Cadet Entry Level Award(ELA) Part Four. Fire Safety

CORPORATE SERVICES HEALTH AND SAFETY

Ventilation for Smoke Control, Fire Control & Life Safety in Tunnels. Dr. Ricky Carvel BRE Centre for Fire Safety Engineering University of Edinburgh

TYPE 1 FIRE RISK ASSESSMENT REVIEW (NO DESTRUCTIVE AUDIT)

Early, Accurate Safety Threat Detection Integrated for Transit Risk Management & Emergency Response

BUILDING INDUSTRY TUNNEL RAIL TUNNEL FIRE FIGHTING WITH HIGH PRESSURE WATER MIST

Tunnel Fire Dynamics and Evacuation Simulations

PREMISES FIRE SAFETY HANDBOOK

TUNPROTEC. Active Tunnel Fire Protection

Guidance on Video Smoke Detection Technology (VSD)

NON ELECTRICAL LOW LEVEL GUIDANCE SYSTEMS EMERGENCY LIGHTING. Photoluminescent Low Level Wayguidance Systems - Overview

PASSENGER RAIL NETWORK LIGHTING OF STATION ENVIRONMENT TO COMPLY WITH DISABILITY STANDARDS FOR ACCESSIBLE PUBLIC TRANSPORT

Chapter 9 Route window W18 Slough station. Transport for London

Transcription:

Underground fires in metro systems failures, accidents and terrorism Dr Fathi Tarada Mosen Ltd RIFA Seminar 22-03-2018

Issues Higher threat of fire & explosions in congested underground metro stations? What do recent incidents tell us about the way forward? TST Station Fire, Hong Kong

Agenda Historical underground metro fires Firebomb attack on TST Station, Hong Kong Reaction-to-fire properties of rolling stock Cross-passage spacing Future fire safety measures

Historical underground metro fires

18 Feb 2003 Arson attack 192 deaths, 151 injuries Two subway trains destroyed Doors locked on second train Jungangno Station, Daegu Subway, South Korea

King s Cross Fire, London, UK 18 November 1987 31 deaths, 100 injuries Match ignited rubbish underneath escalator?

28 th October 1995 Electrical fault Train stopped between stations Ventilation drew smoke over evacuees 289 fatalities, 270 injuries Baku Metro Fire

London Underground Bombings 7 th July 2005 Three trains underground trains bombed Homemade organic peroxide-based devices in backpacks 37 fatalities Incident trains smouldered, but did not burn

Firebomb attack on TST Station, Hong Kong

Background to TST Station Firebomb 10 th February 2017 19 injured, including 3 critically hurt Arson attack with liquid accelerant Similar attack occurred in 2004 Attack

Lessons learnt from TST Station Incident Human factors reaction of passengers (standing around, taking pictures) Lack of CCTV cameras on the platforms Good reaction-to-fire properties of train materials Smoke escape to platform: close doors after evacuation? Delay in station operator response Conditions would be far worse in tunnel

Reaction-to-fire properties of rolling stock

Superseded Standard BS 6853:1999 Code of practice for fire precautions in the design and construction of passenger carrying trains 3 vehicle categories: Category I: underground - Category Ia - single track tunnel with no side exits to a walkway - Category Ib - multi-track tunnel or a tunnel with side exits to a walkway - Category II: surface - A lot of rolling stock to this or to older standards still in operation

Current Standards BS EN 45545:2013 Railway applications - Fire protection on railway vehicles (in seven parts) BS EN 50553:2012 Railway applications - Requirements for running capability in case of fire on board of rolling stock New rolling stock normally specified to these standards in Europe

BS EN 45545:2013 Minimise the probability of a fire starting Control the rate and extent of fire development Minimise the impact of the products of fire on passengers and staff 4-minute running capability at an average speed of 80km/h

BS EN 50553:2012 Considers luggage fires, vandalised seat fires, some diesel fires and significant arson events Minimum running capability of 15 minutes for individual on-board systems including cables, technical cabinets, pneumatic and hydraulic equipment

METRO project Mälardalen University, Sweden Maximum fire heat release rate of 77 MW for carriage fire including luggage Difficult to start the fires! 10 litres of diesel fuel required for ignition Minimum heat release rate for ignition was 2 to 3 MW Combustible linings carriage did not comply with current European rolling stock standards

CFD Simulation of Fire Growth in Train Ignition heat release rises to 150 kw after two minutes Conditions within carriage untenable after 3 minutes (heat release rate 540 kw), even with in-car ventilation switched on to dilute smoke Contours of surface heat flux

Cross-passage spacing

Cross-Passage Spacing Standards Standard Cross-Passage Spacing NFPA-130 Australian AS 4825 European TSI Singapore SFSRTS 244m 240m 500m 250m Significant difference between European TSI and other standards

Cross-Passages in Practice London Crossrail scheme: has crosspassages at approximately 500m spacings, with a maximum spacing of up to 693m Risk assessment undertaken Negotiation with the London Fire Brigade

Frequency (per 100m per year) Quantitative Risk Assessment Estimate societal risk for compliant and noncompliant cross-passage spacings Investigate additional mitigation measures such as dynamic signage to aid evacuation Significant cost-savings can be obtained whilst maintaining acceptable risk levels (performancebased design) 1.00E-03 1.00E-04 1.00E-05 1.00E-06 1.00E-07 1.00E-08 1.00E-09 1.00E-10 1.00E-11 1 10 100 1000 Consequences (Fatally Injured People) Line of A Line of Ir Baseline Current Current

Future fire safety measures

Future Fire Safety Measures Tracking and communication with passengers via mobiles, including underground areas Dynamic evacuation signage Further improvements in reducing combustibility of rolling stock materials Innovative ventilation systems for confined spaces (e.g. MoJet )

Overview

Overview Historical underground metro fires Firebomb attack on TST Station, Hong Kong Reaction-to-fire properties of rolling stock Cross-passage spacing Future fire safety measures