Flue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections

Similar documents
9 inch and 12 inch Axial Fans Models MV230P, MV230AR and MV300AR Instructions for installation, maintenance and safe use.

Exhaust Duct Design Page 1 of (C)

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

Domestic AC Fans 230V Installation and Operating Guide. eco. 230V AC Base Models: icon eco icon icon icon

5.5.1 General CD/30 (Oil Condensing Boiler Installation Assessment Form) General Technician Stationary...

100 FLUEBOOST

CP+ Gas & Oil Cabinet Heater Range

VPC Gas Cabinet Heater Range

Riva Studio Dedicated Sealed External Air Kit

TECHNICAL BOOK 4: OIL FIRED APPLIANCE & SYSTEM INSTALLATION REQUIREMENTS

Flue & Chimney Systems

WHHR Midi & Midi Lite

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

INSTALLATION & COMMISSIONING INSTRUCTIONS Model: 990 CH

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw

Technical data Chimney fans, controllers and accessories in systems for gas fireplaces, stoves and single non-modulating gas boilers

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW

Sirius FS. Working towards a cleaner future

FLUEBOOST. flueboost 350 gas fire model

Technical data Chimney fans, controllers & accessories in systems for multiple heating appliances

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

Esse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL

Colt CoolStream Evaporative Cooling & Ventilation System

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

Centrifugal Fans and Blowers

Design Specifications for Panda 900A Car Spray Booth

Colt CoolStream Adiabatic Cooling & Ventilation System

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

The New Remeha Quinta Pro Selection, Design and Installation of Flue Systems

PREEVA air handling unit

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

Installation and Operating Manual Drying Cabinet

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

Gas-fired unit heaters for indoor installation

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

Centrif Duo & Centrif Duo Plus

PVE SERIES POWER VENTER SYSTEM MANUAL

MODEL 466 Radiant / Convector Gas Fire Black Beauty

User Manual. PO Box 11 Ashton Under Lyne OL6 7TR +44. (0) Fax +44. (0)

ARCHIVED. Compliance Document for New Zealand Building Code Clause G4 Ventilation Second Edition. Prepared by the Department of Building and Housing

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

PRODUCT RANGE: ROOFTOP PACKAGE

Dovre 250 Cast Iron Gas Stove

RAYPAK HOT WATER & HEATING

Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Installation Instructions

SUBMITTAL SCHEDULE & DATA

TopGas Cascade Condensing Gas Boilers Technical Information and Assembly Manual Output range 60 to 720 kw /17 Subject to modification

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

EHH SERIES DRAW THROUGH FAN COILS CFM

FM900. Installation, Operation and Maintenance Instructions. Built-In Extractor

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Firebird Enviromax Condensing Range

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

ELTSHDC110SG/ Users Guide & Installation Instructions

Commissioning of Heat Producing Appliances Burning Solid Fuel

COOLflow 4E PRODUCT RANGE

OUH Oil Unit Heater Range Controlling your working environment. heating ventilation integrity

OUH Suspended Oil Unit Heater

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Lo-Carbon Quadra Centrifugal Fan

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

60cm Chimney Extractor

2012 INTERNATIONAL FUEL GAS CODE VENTS

Purge Ventilation Unit. Product Manual. ventilation systems TP625

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Thank you for choosing EnviroVent

Equipment Layout Manual. For Cooling Towers, Evaporative Condensers & Closed Circuit Coolers

POWER VENTER. Model: PVE Series

Compact HE. High efficiency combi boiler. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

"HC" AIRFLO. In-duct firing line burner

Condensing Boilers. Floor Mounted - Evomod, Imax Xtra & Imax Plus III. Commercial Heating Solutions.

INSTALLATION AND SERVICE MANUAL. Hot Water Heating Boilers Domestic Hot Water Supply Boilers 399, ,000 Btu/hr Models

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

HEAT RECOVERY AIR HANDLING UNIT

COOKER HOOD USER HANDBOOK FOR INSTALLATION AND OPERATION MODELS CRC95

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Intumescent Fire Dampers

RSIF Power Venter. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

Transcription:

Now includes a Pressure Safety Switch and easier Electrical Connections Flue Dilution Fans VISIT US AT www.airflow.com UK SALESLINE 0845 330 1047 Specialists in Air Movement Technology

SAFETY - NEW Differential Pressure Safety Switch for boiler shut down in the event of fan failure or blocked flue. SIMPLE - NEW electrical connections, designed with the installer in mind. FLEXIBLE - siting of boilers within new or refurbished plant rooms. ELIMINATES - unsightly external flues; and the need for expensive installation or refurbishment of internal flues. EFFICIENT - and quiet centrifugal fans capable of overcoming system resistance in flue duct runs. HIGH LEVELS of protection with the use of stainless steel casings on enhanced corrosion resistance versions and Aluzinc coated steel on standard versions. Flue Dilution With the main advantage of avoiding the use of unsightly or expensive flues, regulations require that if the products of combustion are dispersed at low level, then the CO 2 content must be 1% or below. The Airflow flue dilution fans achieve this by introducing fresh air into the boilers discharge flue duct and diluting the flue gases. With the correct selection of fan for the boiler rating and the recommended flue duct layout the 1% CO 2 level will be met. By following the recommended installation, mixing of fresh air and combustion gases takes place before the fan inlet, within the fan and in the discharge section giving satisfactory and safe discharge at low levels. Correct installation also ensures a long and trouble free service life. However on the rare occasion that a problem may occur with the fan or in the flue duct system the built in self proving pressure safety switch is an important safety feature. This switch consists of a relay circuit which will fail safe and prevent operation of the gas burner under the following conditions: a) loss of fan air supply due to blocked intake or discharge flue or fan motor inlet. b) a stalled fan motor c) interrupted power supply The relay contacts are rated at 5A maximum for non inductive load. For normal operation this switch allows the boiler to fire when the fan is operating correctly and dilution air is entering the fan. (i) Dilution Fans are intended for use in Boiler Rooms where the maximum temperature is to 40ºC at ceiling height. (ii) Ensure fan is sized to cope with system resistance of all ducts including motor side inlet duct if fitted. (iii)if motor side inlet is open to the Boiler Room, adequate ventilation must be provided to the Boiler Room. dilution air inlet to dilution system diluted combustion products outlet duct 2 metres long minimum for satisfactory mixing discharge should be 2 metres above ground level unless otherwise approved by local environmental health authority condensate drain air intake over motor if motor inlet side is ducted from outside i) ensure ease of removal for servicing (ii) incorporate bend to prevent wind pressure causing spurious switching of self proving safety switch low level grilles for combustion air and boiler room ventilation. increase by a factor of 2 on sizes recommended in bs6644 if motor cooling is drawn from boiler room Fig 1. (iv)multiple boiler installations can use a common header as long as the Dilution Fan has been sized for total kw input. (v) Duct sizes must match the inlet and outlet spigots and flange of the selected Dilution Fan. (vi)where flue gas temperatures and/or dilution air are likely to cause condensation in the ducts, stainless steel versions type SSDF should be used. high level grille for boiler room ventilation. see BS6644 for recommended sizes condensate drain boiler boiler flue & draft stabiliser (if draft diverter is not part of the appliance) dilution fan clearance required for motor and impeller removal

New for the MK5 The new MK5 range of GBDF and SSDF fans now feature: Differential Pressure safety Switch which will activate if the fan stops operating or if the duct system becomes blocked, thus shutting down the boiler. 6 or 10 Pole Plug and Socket for easy wiring and installation. Easier electrical Connections New Pressure Safety Switch The Range The Airflow Range of flue dilution fans is available in 5 sizes to satisfy the dilution needs of industrial and commercial boilers rated up to 650 kw (2,200,000 Btu) input. Each size is available in standard form (GBDF series) for atmospheric boilers and water heaters of circa 75% SSDF3 efficiency. If excessive corrosion causing the failure of a GBDF series unit is due to the presence of residual condensate, then this will not be covered by our warranty. Enhanced corrosion resistance versions (SSDF series) with stainless steel fan cases are also available for installation where regulations or the specification calls for stainless steel ducting, and when higher efficiency boilers such as modular designs are likely to produce condensation. SSDF s are therefore recommended for installations where condensation will occur. Typical Installations Important when designing and installing a dilution system incorporating Airflow flue dilution fans, attention should be paid to the latest edition of the following standards and guides. (i) BS6644: 2005 Installation of gas fired hot water boilers of rated input between 60 kw and 2 MW. (ii) The institute of Gas Engineers & Managers Utilization procedure UP/10 Part1. Installation of Gas Appliances in Industrial & Commercial premises. (iii) Department of Environment - Chimney heights; Third Edition of the 1956 Clean Air Act Memorandum. The boiler is connected by a vertical flue to a header which is open to the outside air at both ends. One end of the header acts as the primary air intake for the dilution air and the other as the discharge. The fan is located on the discharge side of the header duct. Note: a draught stabiliser or diverter must be incorporated in the boilers primary flue, if not part of the boiler. Shown in Fig 1. is a typical boiler house installation incorporating an Airflow dilution fan illustrating the requirements for satisfactory and safe operation.

Choosing the Correct Size and Type of Fan Where possible there should be at least 2 metres of flue ducting from the fan to the outlet. To ensure a maximum of 1% CO 2 content at the outlet, the volume flow rate of diluted flue gases necessary for a given boiler can be calculated as follows: Flow rate in litres/s = 2.69 x rated input of boiler in kw. Where 2 metres of discharge ducting is not possible then the calculation is: Flow rate in litres/s = 4.44 x rated input of boiler in kw. The volume flow rate provided by the fan will depend on the static pressure imposed by the size and length of flue ducting and the number of bends, louvres etc. comprising the installation. The performance table below enables selection of the correct dilution fan based on the flow rate requirement and the fans ability to overcome duct system resistance. (Note if LPG or Butane are being used then the factors above should be increased to 3.23 and 5.33 respectively. These flue dilution fans must not be used for any other fuels). Performance table at 20 C FAN Static Free SIZE Pressure Air 10 20 30 40 50 60 70 80 90 100 110 (Pascals) GBDF 2 Volume SSDF 2 Litre/s 300 290 280 260 250 240 230 220 190 140 80 40 GBDF 3 Volume SSDF 3 Litre/s 600 580 570 560 540 520 510 500 480 460 440 410 GBDF 4 Volume SSDF 4 Litre/s 1000 985 970 950 935 920 900 880 860 840 815 780 GBDF 5 Volume SSDF 5 Litre/s NOT SUITABLE DO NOT USE 1400 1370 1350 GBDF 6 Volume SSDF 6 Litre/s NOT SUITABLE DO NOT USE NOTE: A MINIMUM DUCT RESISTANCE OF 90 Pa ON THE SIZE 5 AND 180 PA ON THE SIZE 6 IS NECESSARY TO AVOID OVERLOADING MOTOR 120 130 140 160 180 200 225 250 275 300 325 350 375 0 380 320 280 120 40 0 760 740 710 640 520 340 200 80 0 1325 1300 1260 1200 1150 1075 975 850 450 200 80 0 1750 1675 1570 1420 1280 1085 850 625 460 Typical performance table at 20 C The above calculation should generally be used. However, if all the following conditions can be met then the typical performance table shown below can be used. (i) Ducts match inlet and outlets of fan. (ii) The louvres on the discharge and fresh air inlets have 50% FREE areas and not less than the minimum sizes shown in the chart below. (iii) The dilution air inlet is on the same face of the building as the discharge. (iv) There are not more than two right angle bends in the system. (v) The flue system is not more than 10 metres total length and includes not less than 2 metres after the fan outlet. FAN SIZE UNITS GBDF 2 GBDF 3 GBDF 4 GBDF 5 GBDF 6 SSDF 2 SSDF 3 SSDF 4 SSDF 5 SSDF 6 maximum boiler input rating kw 80 160 270 425 650 minimum inlet duct diameter mm 254 305 305 457 457 minimum inlet louvre size mm 300 x 300 400 x 400 400 x 400 600 x 600 600 x 600 minimum discharge duct diameter mm 225 275 345 370 457 minimum discharge grille size mm 300 x 300 400 x 400 450 x 450 500 x 500 600 x 600 diluted flue gas volume l/s 215 430 730 1145 1750 total static pressure loss in system pa 70 93 130 160 180 maximum flue velocity m/s 5.5 7.3 7.9 10.7 10.7 FAN MIN. DUCT MAX. LINE SIZE RESISTANCE CURRENT GBDF 5 90 Pa 2.6 AMPS SSDF 5 GBDF 6 180 Pa 2.9 AMPS SSDF 6 THESE minimum duct resistances required on model sizes 5 and 6 to avoid overloading motors. General Installation Advice Each Airflow flue dilution fan is provided with a fresh air inlet on the drive side of the fan. Typically 30-40% of the air passing through the fan enters this inlet which if not ducted to the outside takes fresh air from the boiler room. An adequate supply of fresh air by means of inlet louvres in the boiler room walls must be made available to the boiler to provide air for combustion and ventilation. To ensure this AND provide dilution air to an unducted motor side inlet the following calculation for high and low level grilles should be used. Low level (intake): 1080 cm2 plus 9 cm2 for each kilowatt input in excess of 60 kw rated input. High level (extract): 270 cm2 plus 2.25 cm2 for each kilowatt input in excess of 60 kw rated input. In order to avoid recirculation and therefore build-up of products of the combustion in the system, it is advisable to ensure that the dilution air inlet is at least 2 metres (6ft) from the discharge. If positioning of discharge and inlet is difficult, it is always better to have the discharge higher than the inlet as the warm diluted products of combustion will rise due to convection and be taken away. If the inlet and discharge are well over 2 metres (6ft) from each other their height relationship is generally of little consequence. It is essential to provide easy access to the fan motor to facilitate repair or maintenance. See minimum clearance figures on back cover.

Condensation It is recommended that drains are incorporated into the duct systems when condensation of the combustion products is likely to occur (see typical installation diagram). Condensation should not be allowed to collect in the fan casing Electrical Installation In all classes of installation, it is essential that the pressure safety switch is connected into the supply circuit of the appliance gas valve so that the gas valve is shut off in the event of a fan failure or flue system blockage. After the fan has been installed and electrically connected, a check should be made to ensure that the pressure safety switch causes the boiler to be switched off when failure or blockage is simulated. Dimensions FAN SIZE A B C D E F G H I J K L M N P R S 2 218 238 179 200 9.5 402 251 265 78 106 304 335 140 191 260 222 101 3 250 270 236 257 9.5 440 302 302 78 109 359 394 175 222 294 281 109 4 352 384 263 295 9.5 578 302 340 78 141 408 445 194 256 409 321 12t Approval of System Boiler installations incorporating fan diluted flue systems with low level discharge are subject to the conditions of the Clean Air Act and therefore local Environmental Health Approval should be sought. Materials Standard GBDF units have cases manufactured from Aluzinc coated mild steel, with cases finished in black Polyester high temperature paint. Enhanced corrosion resistance SSDF units have cases manufactured from 316 grade stainless steel and are supplied in this finish. Impellers for the GBDF and SSDF sizes 2 and 3 are manufactured in Aluminium, while GBDF4, 5 and 6 are produced from Aluzinc coated mild steel (painted). SSDF4, 5 and 6 impellers are manufactures from 316 grade stainless steel. FAN SIZE A B C D E F G H I J K L M N P R S 5 360 386 298 321 7 761 454 454 200 200 500 585 233 314 411 350 129 6 490 517 332 355 7 892 454 454 200 200 500 585 232 336 542 384 145 Specifications FAN WEIGHT ELECTRICAL START FULL LOAD MOTOR NOMINAL MAX SIZE Kg SUPPLY CURRENT RUNNING POWER IMP. AMBIENT V/Ph/Hz AMPS CURRENT WATTS SPEED RPM TEMP. AMPS GBDF 2 9.1 230/1/50 1.2 0.64 75 900 40 C SSDF 2 8.8 230/1/50 GBDF 3 12.1 230/1/50 2.5 1.45 120 860 40 C SSDF 3 12.0 230/1/50 GBDF 4 22.5 230/1/50 8.4 2.8 335 930 40 C SSDF 4 23.4 230/1/50 GBDF 5 42.8 415/3/50 12.0*(line) 2.6* SSDF 5 44.0 415/3/50 (MAX) GBDF 6 46.7 415/3/50 12.0*(line) 2.9* SSDF 6 47.5 415/3/50 (MAX) 900 900 940 900 40 C 40 C FAN SIZE minimum clearance mm in. GBDF 2 SSDF 2 250 10 GBDF 3 SSDF 3 300 12 GBDF 4 SSDF 4 460 18 GBDF 5 SSDF 5 500 20 GBDF 6 SSDF 6 630 25 *LINE CURRENT Minimum clearance for servicing motor and impeller (between motor side inlet and any obstruction).

Specialists in Air Movement Technology visit us at WWW.AIRFLOW.COM SALESLINE 0845 330 1047 UK CUSTOMERS ORDER ON-LINE www.airflow.co.uk AIRFLOW Airflow Developments Limited, Lancaster Road, Cressex Business Park, High Wycombe, Buckinghamshire HP12 3QP, England Telephone: (Int +44) (UK 0) 1494 525252 Facsimile: (Int +44) (UK 0) 1494 461073 E-Mail: info@airflow.co.uk Web Site: www.airflow.co.uk Specialists in Air Movement Technology Airflow Lufttechnik GmbH, Postfach 1208, D-53349 Rheinbach, Germany. Telefon: 02226/9205-0, Telefax: 02226/9205-11 Airflow Lufttechnik GmbH, o.s. Praha, Hostýnská 520, 108 00 Praha 10 - Maleöice, Czech republic. Telefon: 02-74772230 Telefax: 02-74772370 Airflow Developments Limited reserve the right, in the interests of continuous development, to alter specifications without prior notice. All orders are accepted subject to our conditions of sale which are available on request. ADF150/0705