The all-in-one airlock. Models: SkySas BA9S, SkySas BA9L. Manual Attack Resistance. Recyclable product. Ballistic Resistance.

Similar documents
SpeedStile FP. Full-Panel Speed Gate with Sliding Glass Barrier

Circlelock. The high security interlocking door. Security Access. Security Access

Prevent Piggybacking and Tailgating

SoloTek Detecting pass-throughs for effective control over sensitive areas

Gunnebo SpeedStile BP. BA/EV Series. Bi-parting Speed Gate for Internal Installation

SpeedStile FP/FPW. Full-Panel Speed Gate for Internal Installation

Entrance Control Range

Gunnebo SpeedStile BP. DS Series. Bi-parting Speed Gate for Internal Installation

OptiStile 400. Non-Barrier Optical Turnstile

Tripod Turnstiles. Tripod Turnstile for Public Transport Application

SlimStile BA. Tripod Turnstile for Internal Installation (*)

CIRCLELOCK COMBI YOUR ENTRY EXPERTS. THE HIGH SECURITY CONNECTION PORTAL

Outline Specification: EDSUKMT1 MAN TRAP CYLI NDER GATE

Groupe de sécurité Gunnebo 28 mars 2017 page 1. SoloTek

SECURITY PORTALS and DOORS

Custom options such as housing finishes and design, lid have their presence felt. A combination of sleek, sophisticated

OptiStile 220. Swinging Barrier Arm Optical Turnstile

DORTEK. Comprehensive range of certified high-security doors

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

CD30 Codoor. Instruction Manual

ACCESS SOLUTIONS GALAXY GATE. Access Solutions BEOPEN

FLEXIBLE DOOR SOLUTIONS FOR VARIOUS BUILDING TYPES. KONE automatic sliding doors

Transaction Windows and Security Entrances

FLEXIBLE DOOR SOLUTIONS FOR VARIOUS BUILDING TYPES. KONE automatic sliding doors

DORTEK. Comprehensive range of certified high-security doors

In N/C the SpeedStile provides a closed walkway and will only open on acceptance of an authorised signal.

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

L O D G I N G S Y S T E M S

Kerberos Tripod Barriers

S4C Furniture Schedule

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

IFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32

Air Shower with Integrated Air Handling Unit

AE-CU Adaptive Escape Routing for Emergency Lighting. From static to adaptive escape routing

ECO ETS Electromotive drive

Product information Flat glass product ISD for VELUX flat roof windows CFP/CVP Integra

Bi-Directional Barrier Arm Turnstile

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

Excel-EN Conventional Fire Control Panel

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

SECTION 15 BUILDING SECURITY. Table of Contents

Evacuate everyone Sonos Pulse & Nexus Pulse

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

MAKING MODERN LIVING POSSIBLE. Danfoss Heating. RET2000 B/M/MS Electronic digital thermostat with LCD Installation Guide

June 10, 2002 DF C S2424

RFID Card Access Control Unit. Operating Instructions

Motorised swing doors User manual (translation of the original instructions) IP2225EN

CONDOR. Supply air ceiling QUICK FACTS

Remote Control Garage Doors

Condensing Units CUS 15-60

Strikemaster ES Engineering Manual

GreenCon On/Off Room Thermostat

Apartment building safety audit assessment

The following modes can be set when the units are installed, and/or can be changed later through use of a push button on the desktop controller:

DATA & FACTS Clean Rooms DencoHappel Air Shower. Active Air Shower for Personnel in Clean Rooms

Manually hinged ventilation rooflight

The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Air Shower TECHNICAL DATA

Controlled access gates especially designed to allow people quick, safe and controlled access to installations of all types.

A. Section Masonry Assemblies: Anchor placement in masonry.

A Beginners Guide to Inner Range Systems

intelligent solutions

Product datasheet High speed door Albany HS9010PEM. ASSA ABLOY Entrance Systems

Effective Human Detection and Tracking Security Using Machine Vision

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

22-F fire exit rim device for all types of 4 x 8 (1219mm x 2438mm) single doors and 8 x 8 (2438mm

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

PowerMaster. Expanding the Boundaries of Security. PowerG. Technology. with

Challenger Series Users Manual

Tek-ENTRY Apartment Entry Systems

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

MEDUSA. Universal dome housing for discreet surveillance Revision 1027

COR Series AIR CURTAINS. Air curtains. Dimensions (mm) Accessories. Technical characteristics

OPTICAL TURNSTILE SYSTEM

DIGITAL LOCKING SOLUTION

NOVOLAY secure. PYRANOVA secure. Special glass types with outstanding safety properties

DATASHEET VARIOSPEED 6 EMERGENCY RETRACT UNIT CONTROLS AT MOTOR (VS6-ERU-CAM)

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE

MEDUSA. Universal dome housing for discreet surveillance Revision 1120

RFP Addendum 2 March 31, 2016

November Safety Subject

Tek-ENTRY Vandal-Resistant Apartment Entry Systems

Walk-Through Metal Detectors Technical Comparison Chart

AutroVoice voice alarm system AUTROVOICE VOICE ALARM. Loud and clear information

CoreLine Panel the clear choice for LED

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

Tek-SAFE Area of Rescue Assistance System

ChurchSafety InfoSheet: New Fire Regulations Regulatory Reform (Fire Safety) Order 2005

WEMBLEY WINDOWS. Upvc & Aluminium Windows, Doors & Conservatories

\ Page 1

YOUR SINGLE SOURCE FOR EMERGENCY RESPONSE CLOSURE PRODUCTS

Advisor Advanced User Guide

ES 200. Sliding door operator

LAYOUT The system requires no data network. Very simple installation. Only 220V ac power supply indispensable. LEGEND P ET C P COIN BAR PAN KIT CAP

HRX Technical Manual. Version 1.2

CALL FOR A FREE SURVEY

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

Transcription:

SkySas BA The all-in-one Manual Attack Resistance Ballistic Resistance Access Flow Recyclable product Energy savings Eco-design Models: SkySas BA9S, SkySas BA9L

ALL-IN-ONE AIRLOCK The SkySas BA has been designed to extend security perimeter and so ensure that vulnerable premises remain protected, combining control and easy transition Its rectangular shape and the small footprint mean that the SkySas BA can fit easily into all spaces. The SkySas BA is delivered assembled and ready to install on a finished floor, minimising installation and commissioning. The slim design simply integrates into any type of environment, whether installed inside or on a building s facade. The SkySas BA is resistant to vandalism and can optionally feature manual attack or ballistic resistance. It can be used in free access mode or can be integrated with access control also single-person detection and/or identification and therefore can meet most of your requirements. Benefits 1. Rectangular single-unit, transparent and sleekly designed. 2. Effective filtering of people flow and resistance to attacks. 3. Economic solution with minimal installation and commissioning.

Design Construction Gunnebo patented aluminium section side hung doors and walls Laminated glass security panel Melamine ceiling. Opening system Manual electrical locking side hung door using fail-safe electropiston. Finish Powder coated paint. Colour Light Grey RAL 7035 Dusty Grey RAL 7037 Aluminium RAL 9006 White RAL 9010 Other RAL colours Resistance level Vandalism resistance (EN 356) P2A Manual attack resistance (EN 356) P6B Manual attack resistance (EN 1627) 1 RC3 Ballistic resistance (EN 1063) BR3-S and BR4-NS 1. Door mounted into either the facade or the brickwork. Structure Operation In standby mode, both doors are closed and the outer door is unlocked (locked if access by external card reader). Entry The user opens the outer door and enters into the. The door closes once the user has entered. The detection system checks that someone is present in the (using the 1-zone contact mat) or that only one person is currently using it (using the 2-zone contact mat). Once these checks have been carried out and as soon as the opening request has been received, the outer door locks and then the inner door unlocks. The user then opens the door and exits the. The door closes and locks once the user has exited. Exit Once the opening request has been received, the outer door locks and the inner door unlocks. The user opens the door and enters into the. Once the door is closed and checks have been carried out, the inner door locks and the outer door unlocks. The user then opens the door and exits the. The door closes and remains unlocked. Control and Detection User checks are carried out by a combination of tried and tested access and detection systems built around simple technologies. REQUEST AND Detection systems Request by pushbutton Request by card reader 2 (not supplied) Identification by biometric reader inside Presence detection by 1-zone contact mat Single person detection by 2-zone contact mat Free access Controlled access Identified access 2. Compatibility with most access control systems by using dry contacts. Standard Optional Not available

User Safety In the event of an emergency, If the locks are fail-safe type, the doors can be electrically unlocked and the evacuated by an external command (via the central unit) or a break-glass unit. When located in a secure zone, the break-glass unit can be used to unlock both doors. When located within the, it can be used to unlock the door that leads to the outside. If the locks are fail-secure type, a cylinder (maybe a knurled button - optional) is used to mechanically open the door. In the event of a power failure, the can be operated by battery backup for up to 2 hours (depending on how often it is used). Optional Equipment Control console Intercom Voice synthesizer 24 hour battery backup Additional door contact for alarm Break glass unit Mechanical lock High security cylinder Pre-cabling for access control Lighting Technical data Structural opening H+10mm, W+10mm Floor Finished floor Floor level +/ 5mm External facade installation Yes Airlock delivery Assembled 1 Panel delivery Assembled 1 Maintenance accessibility 500mm clear above Power supply 2 110/230Vac, 50/60Hz Operating voltage 24Vdc Consumption 100W Ambient temperature 0 C/+40 C Relative humidity <90% with no condensation Cable routing From top on the lock side Control unit located On the ceiling 1. Can optionally be delivered dismantled. 2. Power supply provided by the client with protection system in compliance with regulations (10A/30mA).

Functional Data and Dimensions Flow Disability access Emergency exit 4 people/minute No No Dimensions (mm) W-Overall Width PW-Passage Width H-Overall Height PH-Passage Height D-Depth Weight (Kg) SkySas BA9S 877 1 725 250 1170 2270 2045 SkySas BA9L 930 2 1125 280 1. Opening to 90 2. Opening to 180

PS-AIRL-SKYSAS BA-062012-2-ENG The data given in this material may be subject to change without further notice. The Gunnebo logo and Gunnebo For a safer world are registered trademarks of Gunnebo AB. See www.gunnebo.com for more information.