Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Similar documents
WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

Installation LC800. Patient Care Unit, 47", Fixed Water Closet. Table of Contents

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

LVRD3. Verge Lavatory System LVRD-Series with Evero Natural Quartz Material WARNING

Installation LC840. Patient Care Unit, 40", Fixed Water Closet. Table of Contents

Installation LVRD1 IMPORTANT! Verge Lavatory System LVRD-Series with Evero Natural Quartz Material. Table of Contents

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

Installation LD3060. OmniDeck Series. Table of Contents Rev. R; ECM Bradley Corporation Page 1 of 10 3/30/11

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

WARNING NOTICE. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi. IMPORTANT

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

Installation Instructions

LA90 DISCONTINUED IMPORTANT!

LA45 DISCONTINUED IMPORTANT!

Installation WARNING SXWS9561. Stainless Steel Panel Shower

LA60 DISCONTINUED IMPORTANT!

Terreon Lav Decks WARNING

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

Installation TDB3105 IMPORTANT! Table of Contents. Terreon 36" Circular Deep Bowl Washfountain with Infrared Control

Installation TDB3104 WF3204. Table of Contents. Terreon 54" Semi-Circular Deep Bowl Washfountain with TouchTime

Installation TDB3103 WF3203. Table of Contents. Terreon 36" Semi-circular Deep Bowl Washfountain with TouchTime Control

For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

For Service Only. Installation Instructions EXD-3/WH97. Express Deck Lavatory System EXD Series

DISCONTINUED. Installation. SS-2N/ndt/STD SS-2N/ndt/WH. Express Lavatory System SS-Series. Table of Contents

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

Models: FM FM WARNING

Installation Instructions OBSOLETE

Installation Instructions

Installation IMPORTANT! Bradley Multi-Station Wall Sink

WF2503, WF2504, WF2505, WF2508 Terreon Classic Washfountains

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

Installation Instructions

Installation. S Series Navigator Thermostatic Mixing Valve

Installation Instructions

WF2603, WF2604, WF2605, WF2608 Terrazzo Classic Washfountains

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

Installation LVQD2. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF Model Classic Washfountains Pre-Assembled Semi-Circular and Circular with 9" Deep Bowl

Installation LVQD1. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

Package Content. Decor Star 1 2. PL-011-GS Rev. A

Installation Instructions

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

Installation S

Express Lavatory System SS-Series

MINIATURE THERMOSTATIC VALVE

SN2013, SN2033 Sentry Corner Shallow Bowl Washfountains

Installation & Operation Manual

MERIDIAN MODEL# 3793

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

Installation S

Installation S

WF3204. Extra Height 54" Terreon Semi-Circular Washfountain. Specifications

Installation S

SN2005, SN2008 Sentry Circular Shallow Bowl Washfountain

PAT BASIN MODEL 9121, 9131, & 9141

Installation S

Installation & Operation Manual

INSTALLTION FOR THERMOSTATIC VALVES

INSTALLATION INSTRUCTIONS

Installation S IMPORTANT! Bradley Thermostatic Mixing Valve for Individual Showers. Table of Contents

Installation and Maintenance Instructions

INSTALLATION INSTRUCTIONS

SN2003, SN2023, SN2004, SN2024

Installation & Operation Manual

Installation Instructions

SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER

GRANITE COMPOSITE SINK

WF2613 Classic Corner Washfountain with 9" Deep Bowl

SS-3N Express Lavatory System SS-Series

1/7 SPOUT INSTALLATION

Product Description and Measurements MODEL-FVS-1000 MODEL-FVS-1002 MODEL-KBF-1300 MODEL-FVS Thank You

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV)

LIVIN THE DOG LIFE DRINKING FOUNTAINS INSTALLATION & OPERATION MANUAL

ACRYLIC PEDESTAL TUB

Installation & Operation Manual

Features Luxier SP21-SS

Product Description and Measurements. Thank You. Prior To Installation Steps. Waterfall Faucet Installation

TDB3104. Terreon 54" Semi-Circular, Deep Bowl Washfountain

WF2613 Classic Corner Washfountain with 9" Deep Bowl

INSTALLATION INSTRUCTIONS

Heat Exchanger Block Replacement Instructions

? Teflon Tape? 9/16 Fixture Wall Anchors and. ? 9/32 Fixture Wall Anchors and

Ligature Resistant. ADA Compliant

Decor Star 1. Decor Star PL-037-SS

ONE PIECE TOILET LT3. Model: MPN: B0940 INSTALLATION INSTRUCTIONS. Version: 1.0

Features Luxier SP21-SS

ACRYLIC CLAWFOOT TUB

Transcription:

MF2922 - TouchTime Terreon orner-fount Washfountain with TouchTime (Standard, Juvenile and O Height) Table of ontents Supplies Required by Installer.... 2 Pre-Installation Information... 2 Parts included with the orner-fount... 3 Rough-Ins... 4 ssemble Pedestal... 4 Install Pedestal... 5 Install Solenoid ssembly... 5 ssemble and Install owl... 6 Electrical and Supply onnections... 7 djusting the TouchTime Module... 7 heck Operation... 8 Install Top over and Front Panel... 8 leaning and Maintenance for Terreon... 9 leaning and Maintenance for Stainless Steel... 9 rand Names.... 9 Troubleshooting Solenoid Valve... 10 Thermostatic Mixing Valve Troubleshooting... 11 WRNING Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi. Make sure that all water supply lines have been flushed and then completely turned off before beginning installation. Debris in supply lines can cause valves to malfunction. Hardware supplied by installer must be appropriate for wall construction. Wall anchors used must have a minimum pull-out rating of 1,000 lbs. IMPORTNT Read this entire installation manual to ensure proper installation. When finished with the installation, file this manual with the owner or maintenance department. Separate parts from packaging and make sure all parts are accounted for before discarding any packaging material. If any parts are missing, do not begin installation until you obtain the missing parts. Product warranties may be found under "Products" on our website at www.bradleycorp.com. 215-1536 Rev. G; EN 16-00-004L 2017 radley Page 1 of 11 6/9/2017 P.O. ox 309 Menomonee Falls, WI 53052 US 800 RDLEY (800 272 3539) +1 262 251 6000 bradleycorp.com

MF2922 - TouchTime ctivation Installation Supplies Required by Installer (2) 3/8" diameter bolts with washers and (2) wall anchors appropriate for your installation (2) 3/8" diameter bolts with washers and (2) floor anchors appropriate for your installation 1/2" nominal copper tubing for hot and cold water supply lines 1-1/2" NPT drain trap and waste connection Pipe sealant and plumber s putty 110 V power source for 120V/12V D plug in adapter supplied OPTIONL: radley recommends installing an electrical cut-off switch to the unit. This feature allows no accidental water delivery during regular maintenance and service. Pre-Installation Information Terreon Material The orner-fount is constructed of Terreon, a densified solid surface material composed of bio based resin. Terreon is resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleaners or fine-grit abrasives. Terreon is Home Innovation Lab certified to meet S 45.5/IPMO Z124. Touch Time and Solenoid Valve Each TouchTime mechanical pushbutton/piezo switch activates a flow of water. Each nozzle is controlled by a separate solenoid valve, allowing each user to activate a flow of tempered water from one spray nozzle with a pushbutton or piezo switch for 15 seconds. Each valve uses less than half the maximum amount of hot water allowed by the NSI/SHRE/IES 90-1980 Standard. ctivation time can be adjusted in the field. Solenoid Valve: n electronically controlled solenoid valve serves as the metering mechanism. Few moving parts provide reliable metering performance and the solenoid is unaffected by chemicals and minerals often present in municipal water supplies. 2 6/9/2017 radley 215-1536 Rev. G; EN 16-00-004L

MF2922 - TouchTime ctivation Parts included with the orner-fount Separate all parts from packaging materials and ensure you have all the parts required for assembly. If any parts are missing, do not attempt to assemble the radley Terreon orner-fount Washfountain until you obtain all parts. Mechanical Pushbutton Shown (S83-368) Piezo Switch Similar (S83-369) TouchTime Module with Mouting racket (S83-405) Individual TouchTime Module (S83-360) (Nut Included) 2 Way Splitter (251-027) MOUNTING PNELS Hose-Stop Prepack - TM S45-2730 120/12VD Plug-In dapter (261-147) Hose Solenoid ssembly (S08-2412TM shown, S08-2412TL similar) Hose-Stop Prepack - TL S45-2731 (optional) Hose LOWER RKET Stop Stop radley 215-1536 Rev. G; EN 16-00-004L 6/9/2017 3

MF2922 - TouchTime ctivation Installation 1 Rough Rough Rough-Ins in 1/2" nominal copper tubing for hot and cold supply lines through wall or floor at dimensions shown. in 1-1/2" NPT drain waste connection through wall or floor at dimensions shown. ompliance and conformity to local codes and ordinances is the responsibility of the installer. Multi-fount models available with various mounting heights. efore beginning rough-ins, verify if the unit is a Standard, Juvenile or Ontario uilding ode model and rough-in accordingly. WRNING Flush the supply lines before making connections. Debris in supply lines will cause the valves to malfunction. WRNING Wall anchors need to withstand 1000 lbs. pull force. 1-1/2" NPT Waste onnection For Use With 1-1/2" Tubular P-Trap, Stub Out Min. 1-1/2" 110V GFI Electrical Outlet Recommended Location (Refer to Local odes efore Rough-In) 1/2" Nominal opper Tubing For Supplies - Stub Out Min. 1-1/2" From wall 1-1/2" NPT Waste onnection Through Floor (Optional) Stub Up 3" 1/2" Nominal opper Tubing For Supplies (Optional) - Stub Out Min. 1-1/2" From Floor 15-1/2" (394) 6" (152) 4" (102) 3-7/8" (98) 15-1/2" (394) 3-1/2" (89) 24" (610) STD 23" (584) O 20" (508) JUV 4-1/2" 13" (330) STD (114) 12" (305) O 9" (229) JUV (2) ppropriate nchors and 3/8" olts (Supplied y Installer) To Mount owl To Wall Note: Drain, supply and electrical wall rough-in may be installed on either wall. 28" (711) STD 27" (686) O 24" (610) JUV Finished Floor 4" (102) 3-7/8" (98) 9-1/4" (235) 4" (102) Top View Square orner 9-1/4" (235) 3-7/8" (98) 2 ssemble Pedestal Washers are not utilized on back of mounting panels. Fasten the mounting panels to the pedestal with four pan head 1/4"- 20 x 1/2" screws supplied. LEFT PEDESTL PNEL UPPER RKET MOUNTING PNEL 5/16" I.D. WSHER 1/4"-20 x 1/2" PN HED SREW 1/4"-20 x 1/2" PN HED SREW Install the upper and lower brackets to the pedestal panels with two pan head 1/4"- 20 x 1/2" screws and 5/16" I.D washers supplied. RIGHT PEDESTL PNEL ENTERLINE OF FIXTURE LOWER RKET 4 6/9/2017 radley 215-1536 Rev. G; EN 16-00-004L

MF2922 - TouchTime ctivation 3 Install Pedestal Measure efore Remove molding strips or tiles which could prevent a flush mounting to the wall. and mark the centerline of the washfountain on the wall and floor. mounting the pedestal to the floor, make sure the floor is level. If it is not level, be prepared to install shims when positioning the pedestal in Step. MOUNTING PNEL With someone to assist you, move the pedestal assembly to the corner using appropriate lifting procedures, and align the locating notches on the lower bracket with the centerline marked on the floor. If the floor is not level, install shims under the left and/or right pedestal. ENTERLINE D Drill holes in the floor through the two 1/2" diameter holes in the lower bracket and install two anchors (supplied by installer) for 3/8" bolts. 4 E fter ttach onnect floor anchors are installed, secure the pedestal assembly to the floor anchors using two 3/8" bolts and washers (supplied by installer). Install Solenoid ssembly the stops to hot and cold water rough-ins. one end of each supply hose to the stops. Inside the pedestal, install the two 1/4" - 20 x 1/2" screws (supplied with solenoid assembly) in the mounting holes on the side of the left pedestal panel. Do not thread the screw completely into the panel, but allow 5/16" of the screw to be exposed. LOWER RKET PEDESTL SSEMLY Pedestal Panel Module The letter "H" on the Navigator mixing valve ssembly indicates hot water supply inlet. 1/4" - 20 x 1/2" Mounting Screws Valve ssembly (TMV Shown - TL Similar) D onnect E Mount the other end of each supply hose to the Navigator TMV valve assembly (one on the hot side, one of the cold side). the valve bracket and module assembly to the left side of the pedestal. F For optional single tempered supply: attach the stop to the 1/2" tempered supply line. onnect the stop to the solenoid assembly with the flexible supply hose. Supply Hose Hot Supply Inlet old Supply Inlet Stop radley 215-1536 Rev. G; EN 16-00-004L 6/9/2017 5

MF2922 - TouchTime ctivation Installation 5 ssemble and Install owl WRNING Do not leave the bowl on the pedestal unsupported, as it may fall and cause personal injury or damage to property. Discard rubber gasket included with drain spud. It cannot be used in this application. Install two 3/8" wall anchors (supplied by installer) which will be used to mount the bowl to wall (see rough-ins on page 4). ack View of Washfountain owl arefully remove the sprayhead cover. Lock Washer nchor Plate arefully lift the bowl onto the pedestal frame using appropriate lifting procedures. Ensure bowl remains 3-4 from the wall. Hex Nut D Install the two wall anchor brackets to the back of the bowl using the 3/8"- 16 x 1-1/2" hex-head bolts, 13/32" I.D. plain washers, anchor plates, 3/8" I.D. lockwashers, and 3/8"- 16 hex nuts provided. E Uncoil the mechanical pushbutton/piezo switch and plastic tubing from the rear of the backsplash. Make sure not to pinch or crimp the sprayhead supply tubing or sensor leads. Wall racket Guide Tubing Drain ssembly Plain Washer Hex Head olt F Slide the bowl back to the wall and secure the bowl s wall brackets to the wall anchors with two 3/8" bolts and washers (supplied by installer). Dome Strainer #10-24 x ½" Screws for Strainer G Fasten the bowl to the upper bracket on the pedestal assembly with the two 1/4"- 20 x 1/2" round-head screws and 5/16" I.D. washers supplied. Drain Spud H Install I the drain spud in the bowl using plumber s putty. From beneath bowl, thread the spud washer and spud locknut onto the drain spud and tighten the locknut against the bowl. Spud Washer Spud Locknut Washfountain owl Discard this washer; it is not used on washfountains J Install strainer in the bowl drain using the two #10-24 x 1/2" flat socket head screws supplied. K onnect the drain trap (supplied by installer) to the drain spud and drain line. 6 6/9/2017 radley 215-1536 Rev. G; EN 16-00-004L

MF2922 - TouchTime ctivation 6 Electrical and Supply onnections WRNING The TouchTime activation must be connected with a 12V D plug in adapter. onnections to 110 V can cause personal injury and will result in damage to the electronics. Mechanical pushbutton shown, piezo switch similar. ctivation of the push button takes place only when it is released, thereby preventing hold open activation. Left utton Right utton TouchTime Module Loosen the compression nuts. Push the sprayhead supply tubes firmly into the tube connectors until they are fully seated. Tighten the compression nuts by hand. Green Supply Tube (From Sprayhead) Red Supply Tube (From Sprayhead) onnect plug-in D adapter to splitter. ompression Nut onnect splitter connector to TouchTime module. onnect button connector to TouchTime module. Plug-In dapter (261-147) Splitter onnect valve connector to D TouchTime module. 7 djusting the TouchTime Module The TouchTime module is set at the factory with the selector switch in position 5. This provides a 15 second time out period. The 24 hour flush function will activate water flow for a period of 60 seconds any time there has been no activation within the past 24 hours. This function is used to help clear stagnant water from the plumbing system and can provide some measure of prevention against the formation of bacteria in supply pipes. LED Indicator To adjust the TouchTime module to a different time out period, turn the selector switch to the desired time out setting (4 through 9 for no flush, though F for 24 hours flush) as indicated on the module label. Pushbutton onnectors (an use either one or both) Selector Switch Power onnection radley 215-1536 Rev. G; EN 16-00-004L 6/9/2017 7

H MF2922 - TouchTime ctivation Installation 8 heck Operation heck Turn Turn D Loosen to make sure both stops are fully open (see page 5). on the main water supply to the orner-fount and check for leaks. on electrical power and depress each mechanical pushbutton/piezo switch until air is purged from the lines. ap Screw about ¼" (4-6 turns) and lift up cover (do not remove). WRNING This valve is NOT factory preset. Upon installation, the temperature of this valve must be checked and adjusted to ensure delivery of a safe water temperature. Water in excess of 110 F (43 ) may cause scalding. E Using cover, turn cartridge gently until desired water temperature is reached. Do not turn past stops as this may damage unit. Push cover down and tighten screw. 9 Install Top over and Front Panel arefully place the top cover with threaded rods on top of washfountain sprayhead. Inside the pedestal assembly of the washfountain (use front access), slide the anchor plate onto the threaded rods and secure anchor plate against bowl using the wing nuts provided. UPPER RKET To D Secure install front panel, slip slot in bottom of front pedestal panel over the lip on the lower bracket. panel to upper bracket with attached screw. SREW FRONT PNEL LOWER RKET 8 6/9/2017 radley 215-1536 Rev. G; EN 16-00-004L

MF2922 - TouchTime ctivation leaning and Maintenance for Terreon Material Description: Terreon is a densified solid surface material composed of bio based resin and is resistant to chemicals, stains, burns and impact. Surface can be easily repaired with everyday cleansers or fine grit abrasives. ecause Terreon is a unique cast material, its aggregate flow and distribution, and shades of color can vary from product to product creating natural characteristics. Routine leaning: For regular cleaning, use mild neutral base cleaners. Stubborn Stains: Remove tough stains with Soft-Scrub and a green Scotch-rite pad or lightly sand in a circular motion with 240 grit wet/dry sandpaper. The finish can then be renewed with a maroon Scotch-rite pad. Scratches: Remove scratches with a green Scotch-rite pad. The finish can then be renewed with a maroon Scotch-rite pad. Hard Water Deposits: Remove hard water deposits with a mild solution of vinegar and water. lways rinse the unit thoroughly after cleaning. Restoring the surface: Use Hope s Perfect ountertop to refresh and protect the Terreon Solid Surface material. Dark Terreon colors may require additional care and maintenance. For complete instructions on this additional maintenance, visit bradleycorp.com. Repair Kits: Terreon repair kits are available. ontact your radley representative or distributor for part numbers and pricing. Repair kits are made to order and have a shelf life of 30 days. NOTIE! Do not use strong acid or alkaline chemicals and cleaners to clean Terreon. If these chemicals come in contact with the surface, wipe them off immediately and rinse with soapy water. void contact with harsh chemicals such as paint remover, bleach, acetone, etc. void contact with hot pans and objects. leaning and Maintenance for Stainless Steel Material Description: Stainless steel is extremely durable, and maintenance is simple and inexpensive. Proper care, particularly under corrosive conditions, is essential. lways start with the simplest solution and work your way toward the more complicated. Routine cleaning: Daily or as often as needed use a solution of warm water and soap, detergent, or ammonia. pply the cleaning solution per the manufacturer's instructions and always use a soft cloth or sponge to avoid damaging the finish. Stubborn Stains: To remove stains from stainless steel use a stainless steel cleaner and polish such as all stainless steel cleaner or a soft abrasive. lways follow the manufacturer's instructions and apply in the same direction as the polish lines. NOTIE! Never use ordinary steel wool or steel brushes on stainless steel. lways use stainless steel wool or stainless steel brushes. Fingerprints and Smears: To remove fingerprints or smears use a high quality stainless steel cleaner and polish in accordance with the manufacturer's instructions. Many of these products leave a protective coating that helps prevent future smears and fingerprints. Grease and Oil: To remove grease and oil use a quality commercial detergent or caustic cleaner. pply in accordance to the manufacturer's instructions and in the direction of the polish lines. Precautions: void prolonged contact with chlorides (bleaches, salts), bromides (sanitizing agents), thiocyanates (pesticides, photography chemicals, and some foods), and iodides on stainless steel equipment, especially if acid conditions exist. NOTIE! Do not permit salty solutions to evaporate and dry on stainless steel. The appearance of rust streaks on stainless steel leads to the belief that the stainless steel is rusting. Look for the actual source of the rust in some iron or steel particles which may be touching, but not actually a part of the stainless steel structure. NOTIE! Strongly acidic or caustic cleaners may attack the steel causing a reddish film to appear. The use of these cleaners should be avoided. rand Names Use of brand names is intended only to indicate a type of cleaner. This does not constitute an endorsement, nor does the omission of any brand name cleaner imply inadequacy. Many products named are regional in distribution, and can be found in local supermarkets, department and hardware stores, or through your cleaning service. It is emphasized that all products should be used in strict accordance with package instructions. radley 215-1536 Rev. G; EN 16-00-004L 6/9/2017 9

MF2922 - TouchTime ctivation Installation Troubleshooting Solenoid Valve: Part nos. S07-068-D (closed body) & S07-068-D (thru body) Turn off water supplies to the unit before troubleshooting. Item Qty. Part No. Description 1 1 118-334 Valve ody, ¼" losed 1 1 118-334 Valve ody, ¼" Thru 2 1 S27-352 artridge 3 1 125-165 O-Ring, #2-013 4 1 125-460 Flow Restrictor,.5 GPM 2 4 1 3 Problem ause Solution n individual operating station fails to shut off and drips. n individual operating station fails to turn on. Internal cartridge failure. failed cartridge for the valve or loose electrical connection to the terminal. Replace cartridge S27-352. Test the station to determine the cause. 1. Disconnect the wires from the cartridge of an adjacent valve. Disconnect the wires from the problem valve and reconnect to the adjacent valve. 2. Turn on electrical and water supplies to the unit. ctivate the pushbutton/piezo switch on the problem station and the adjacent station should turn on. If the adjacent station turns on and cycles normally, replace the cartridge on the problem valve. If the adjacent valve fails to turn on, inspect the wires from the sensor cable and do the following: make sure there are no breaks and that the fully insulated disconnect terminals are firmly crimped in place; turn off the electrical and water supplies; reconnect to the adjacent valve and turn on the water supplies to the unit; activate the pushbutton/piezo switch. If the station still fails to turn on, replace the pushbutton or piezo switch assembly. 10 6/9/2017 radley 215-1536 Rev. G; EN 16-00-004L

MF2922 - TouchTime ctivation Thermostatic Mixing Valve Troubleshooting efore attempting to troubleshoot the valve or disassemble the components, check for the following conditions: If stop valves are used, make sure that they are fully open. Make sure that the hot and cold inlet pipes are connected properly, and that there are no crossconnections or leaking stop valves. heck the hot water heater output to make sure that it is at least 10 F above the set temperature. e sure to close the appropriate shut-off valves prior to disassembly of the valve and reopen the valves after inspection and repair is complete. Problem ause Solution External leaks. Damaged cartridge or O-rings. Replace cartridge with part number 269-1927 Improper water temperature or temperature fluctuation. Hot water supply is not 10 above desired set point. Increase hot water supply temperature Valve temperature is not properly set. djust the temperature as shown on page 19, step 10. Limited water flow. Dirt and debris have built up in the valve or strainer. 1. heck to make sure both hot and cold supplies are connected to the Navigator mixing valve and that they have water flow. 2. Remove cover and U-clip. Remove the cartridge and clean the strainer. It is not required to grease cartridge, however if desired, use silicone grease only. Do not use grease on check valves. 2 3 1 Parts List Item Part No. Description Quantity S59-4000 1 160-463 ap Screw 1 2 107-582 over 1 3 269-1927 Thermostatic artridge 1 4 198-014 heck Valve* 2 5 132-051 Retaining Ring* 2 6 118-319 Valve ody 1 7 146-079 U-lip 1 * Included with Prepack S65-326 4 5 Tempered Line dapter Option Part no. S39-804 (replaces S59-4000 if tempered line is used) Strainer (173-028) 5 4 6 7 radley 215-1536 Rev. G; EN 16-00-004L 6/9/2017 11