The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni

Similar documents
Ultrasonic Switches. Features & Benefits

Electromechanical Temperature Switches

Electromechanical Temperature Switches

Ultrasonic Point Level Switches

Product Guide Registered Quality System to ISO 9001:2008

Temperature Switches. Request Quote

1510 Side Mounted Level Switch

805QS Pressure Switch-Transmitter

Process Instrumentation. Product Guide

Process Instrumentation. Product Guide. Registered Quality System to ISO 9001

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Certificate of Compliance

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Certificate of Compliance

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 7000 Fixed gas detector

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Thermo Scientific Air Cadet

Dräger Polytron 5720 IR Detection of carbon dioxide

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Technical Specification VFD

M7100 Pressure Transducer

Thermal Management Products & Accessories for Enclosures

Description. Applications

ue short form catalog Leaders in Safety, Alarm & emergency Shutdown

Centro-Matic Automated Lubrication Systems System Controls

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Limit Switch Box YT-870/875 SERIES

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Dräger Polytron 5720 IR Toxic Gas Detection

M5200 Industrial Pressure Transducer

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

SELECTION GUIDE SELECTION GUIDE. Pressure, Flow & Liquid Level Products for Aerospace & Military Uses

Dräger PIR 7200 Toxic Gas Detection Transmitter

U5300 Industrial Pressure Transducer

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and vapors

STT700 Temperature Transmitter Lightning Protection Device Specifications 34-TT-03-20, June 2017

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Enclosure Heaters and Fan Heaters

Annubar Flowmeter Series

Ar-Mite TM Low Flow Armored Flowmeter

Electronic Flow Switches

Dräger PointGard 2100 Detection of toxic gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Certificate of Compliance

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

CR 027 PTC Fan Heater W

Dräger PIR 3000 Detection of flammable gases and vapours

Rosemount 3051 Pressure Transmitter Includes Transmitter Option TR ProductDiscontinued. Start

User s Manual YTA610 and YTA710 NEPSI Certification

U5700 Submersible Liquid Level Pressure Transducer

Dräger Polytron 8310 Stationary gas detector (DSIR)

Dräger Polytron 8000 Stationary gas detector (EC)

E C H O T E L C O N T A C T U L T R A S O U N D

Sensall Sapphire. Thermo MeasureTech ULTRASONIC POINT LEVEL SYSTEM

Performance Data. curus Component Recognized; File No. E IP 20

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

Dräger Polytron 8720 IR Detection of carbon dioxide

Sapphire ULTRASONIC POINT LEVEL SYSTEM

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

ue short form catalog Leaders in Safety, Alarm & Shutdown

Dräger Polytron 8000 Stationary gas detector (EC)

180 Dexter Ave, P.O. Box 9143 Watertown, MA USA Phone: Fax: CP031210K

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Cable Glands DB Series: Drain, Breather Valves and Unions

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

ENERGY, OIL & GAS. astsensors.com macrosensors.com. Transducer & Transmitter Capabilities. Your sensor business partner...

Electronic Pressure Digest. Pressure and Temperature Transmitters

Variable Area Flowmeters Ratosight TM Flow Rate Indicators with Optional Ratolarm - 10A2235

3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction

Sitron s CF Line of Flow Switch Monitors

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

3-6VFD Series Combination Flame and Explosion Proof Pilot Valve Enclosure

Genie Heated Regulator Installation & Operation Instructions

MODEL APT 3700N. Smart Pressure Transmitter For Nuclear Service. Duon System Co., Ltd. for Differential / Gauge / Absolute Pressure Measurement

VersaFlow Coriolis 100 Mass Flow Sensor Technical Datasheet. Specification

BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology

Dräger REGARD -1 Control System

Certification Supplement Manual

MICRO SWITCH BX/BX2 Series

MODEL AV2-C1D1M Hazardous Duty Class I. Div 1, Multitone Alarm Station

UNIVERSAL SOLVENT HEATER

Rosemount 2090P Pulp and Paper Pressure Transmitter

CAST-X Circulation Heater. CAST-X 2000 is a very versatile heater, with multiple housing, standoff, control and enclosure options.

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron Pulsar 2 Open Path Gas Detector

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

DIGITAL METERS Large Display Temperature Meters Instruction Manual

BDI-FLX B URST SY STE M BENEFITS BDI-FLX AVAILABLE FOR INDUSTRIAL AND SANITARY APPLICATIONS

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

Oil & Gas Oil & Gas. Control. every move. Directional Control Valves & Regulators Pressure Switches Temperature Switches Level Switches

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

High Pressure Conductivity Monitor

Worcester Controls PS/PM Series UltraSwitch. Switchbox

CAST-X Circulation Heater. With optional built-in controls, CAST-X 1000 is a straightforward solution, perfect for OEMs and end users.

Transcription:

OEM Pressure Sub-Mini-Hermet and Omni Factory Set Sub-Mini-Hermet The Sub-Mini Hermet has the ability to be externally adjusted without disconnecting electrical service or tamperproof. These field mounted instruments are suited for compact areas and hostile environments. A UL Listed, CSA Certified, and SAA Approved hermetically sealed explosion proof switch capsule is provided in a rugged 316 stainless steel housing for harshest service in hazardous locations. Adjustable Sub-Mini-Hermet Omni pressure switches are environmentally sealed pressure switches that can be externally adjusted without disconnecting electrical service. Diaphragm type switches are recommended for most process applications. Pivot Seal type switches are recommended for fluid power (hydraulic) applications where high-shock pressures and high-cycle rates are expected, and where industrial clean hydraulic fluid is used. Omni 913-888-2630 Registered Quality System to ISO 9001:2008 913-888-2630 1/6

Sub-Mini-Hermet Pressure Product Specifications Enclosure housing contains explosion proof hermetically sealed switching element (See Agency Approvals) NEMA 4X, IP65 Primary Diaphragm O-Ring Viton Pressure Port 1/4 NPT(F) Ambient Temperature Range -40 to 167 F (-40 to 75 C) Process Temperature Range 32 to 400 F (0 to 204 o C) Electrical Connection** 1/2 NPT(M); 18 stranded wire leads, 18-AWG color-coded and marked Electrical Rating 250VAC, 5 amp 30VDC, 5 amp* 125VDC,.5 amp* Weight Approximate 1 lb (0.5 kg) Dimensions Dimensions are for reference only. Contact the factory for certified drawings for a particular model number. (Linear = mm/in.) Adjustable Design and specifications are subject to change without notice. * DC electrical ratings are for resistive loads only. DC ratings are not agency approved or listed but have been verified by testing or experience. ** Change model number from 9013-00_to 9013-10_ for 6 foot leads. Drawing 0091356 The hermetically sealed switching element capsule is UL Listed, CSA Certified and SAA Approved as an explosion proof snap switch per the following table: Agency Hazardous Location Conditions Consult factory for availability of special product configurations: gold contact snap switches for dry circuits; 1/2 NPT(F) or 1/4 BSP(F) process connections; alternate pressure port, diaphragm, or o-ring materials, etc. How to Order UL Listed CSA Certified SAA Approved Class I, Groups A, B, C & D Class II, Groups E, F & G; Divisions 1 & 2 Ex s Zone 2 IIC T4 IP65 Ex td A22 T105ºC IP65 Electical Contact Form 9013-001 SPDT 3 0.2 8-30 0.55-2 9013-002 DPDT 6 0.4 9013-003 SPDT 5 0.35 15-60 1.0-4.1 9013-004 DPDT 10 0.7 9013-005 SPDT 2.8-25 1.7 40-200 9013-006 DPDT 13.8 50 3.5 1500 100 2500 170 2500 170 6000 410 Notes 1. Dead band values are expressed as typical expected at mid-range. 2. Metric bar values are conservative. They are practical equivalents of the reference English values: not necessarily exact mathematical conversions. Safety Certified to IEC 61508 (SIL) SOR products are certified to IEC 61508 for non-redundant use in SIL1 and SIL2 Safety Instrumented Systems for most models. For more details or values applicable to a specific product, see the Safety Integrity Level Quick Guide (Form 1528). 2/6 Registered Quality System to ISO 9001:2008 913-888-2630

Sub-Mini-Hermet Pressure Product Specifications Enclosure housing contains explosion proof hermetically sealed switching element (See Agency Approvals) NEMA 4X, IP65 Primary Diaphragm O-Ring Viton Pressure Port 1/4 NPT(F) Ambient Temperature Range -40 to 167 F (-40 to 75 C) Process Temperature Range 32 to 400 F (0 to 204 o C) Electrical Connection** 1/2 NPT(M); 18 stranded wire leads, 18-AWG color-coded and marked Electrical Rating 250VAC, 5 amp 30VDC, 5 amp* 125VDC,.5 amp* Weight Approximate 1 lb (0.5 kg) Design and specifications are subject to change without notice. * DC electrical ratings are for resistive loads only. DC ratings are not agency approved or listed but have been verified by testing or experience. ** Change model number to _SM-EF -M4-C1A for 6 foot leads. Consult factory for availability of special product configurations: DPDT switch assemblies; gold contact snap switches for dry circuits; 1/2 NPT(F) or 1/4 BSP(F) process connections; alternate pressure port, diaphragm, or o-ring materials, etc. How to Order Dimensions Dimensions are for reference only. Contact the factory for certified drawings for a particular model number. (Linear = mm/in.) Drawing 0090131 Factory Pre-set Non-adjustable The hermetically sealed switching element capsule is UL Listed, CSA Certified and SAA Approved as an explosion proof snap switch per the following table: Agency UL Listed CSA Certified SAA Approved Hazardous Location Conditions Class I, Groups A, B, C & D Class II, Groups E, F & G; Divisions 1 & 2 Ex s Zone 2 IIC T4 IP65 Ex td A22 T105ºC IP65 Accessories Electical Contact Form 6AT - EF19 - M4 - C1A SPDT 6-18 0.4-1.2 3 0.2 6AT - EF20 - M4 - C1A SPDT 18-30 1.2-2 3 0.2 1500 100 2500 170 5AT - EF19 - M4 - C1A SPDT 15-50 1.0-3.5 5 0.35 5AT - EF20 - M4 - C1A SPDT 50-75 3.5-5 6 0.4 9AT - EF19 - M4 - C1A SPDT 35-175 2.4-12 25 1.7 2500 170 9AT - EF20 - M4 - C1A SPDT 175-230 12-16 25 1.7 6000 410 1AT - EF19 - M4 - C1A SPDT 100-315 7-22 50 3.5 5000 340 1AT - EF20 - M4 - C1A SPDT 315-500 22-35 50 3.5 Description Fiber tag with customer specified tag information 304SS nameplate wired to unit with customer specified tag information 304SS nameplate permanently affixed to housing with customer specified tag information. Designator (add after C1A) PP RR TT Safety Certified to IEC 61508 (SIL) SOR products are certified to IEC 61508 for non-redundant use in SIL1 and SIL2 Safety Instrumented Systems for most models. For more details or values applicable to a specific product, see the Safety Integrity Level Quick Guide (Form 1528). 913-888-2630 Registered Quality System to ISO 9001:2008 3/6

Omni Pressure Product Specifications Enclosure Aluminum with corrosion resistant, chromate conversion coating. Environmentally sealed. NEMA 4 Primary Diaphragm (Diaphragm type) Piston (Pivot Seal Type) O-Ring Buna-N Design and specifications are subject to change without notice. Pressure Port (Diaphragm Type) Pressure Port (Pivot Seal Type) Electrical Rating 1/4 NPT(F) carbon steel electroless nickel plated 1/4 NPT(F) brass 250 VAC, 10amps 30 VDC, 5 amps 125 VDC,.5 amps Dimensions Dimensions are for reference only. Contact the factory for certified drawings for a particular model number. (Linear = mm/in.). Diaphragm Type Pressure are suitable for a wide variety of process applicaitons. They are not recommended for high-pressure fluid power applications where highshock pressure and high cycle rates are expected. Drawing 0090179 Set Point Adjustment Under Weathertight Cap Screw 26.4 1.04 52.3 2.06 31.8 1.25 Factory Sealed Leads, Color Coded and Marked 457.2 Minimum Length 18.00 157.0 6.18 30.2 1.19 28.7 1.13 Hex 1/2 NPT(M) Electrical Connection Pivot Seal Type Pressure are disigned for fluid power (hydraulic) applications where highshock pressure and high-cycle rates are expected, and where industrial-clean hydraulic fluid is used. They are not recommended for process applications as the piston requires lubrication for proper operation. Process Connection 4/6 Registered Quality System to ISO 9001:2008 913-888-2630

Omni How to Order Diaphragm Type Pressure Switch Pivot Seal Type Pressure Switch 6AC - AD2 - M2 - F1A 7-30 0.5-2 1.5 0.10 6AC - AD3 - M2 - F1A 12-100 0.8-7 2.4 0.17 5AC - AD45 - M2 - F1A 45-550 3.1-38 10 0.7 1500 100 2500 170 9AC - AD45 - M2 - F1A 200-1750 14-120 40 2.8 2500 170 6000 410 2AC - AD3 - P1 - D1A 100-1900 7-130 125 8.6 2AC - AD5 - P1 - D1A 500-3000 35-205 145 10 3AC - AD45 - P1 - D1A 1000-7000 70-480 290 20 8000 550 10,000 690 Accessories Description Fiber tag with customer specified tag information 304SS nameplate wired to unit with customer specified tag information Factory set and potted to prevent future adjustment of pressure switch Designator (add after F1A or D1A) PP RR TP Test Certificates Certificates C1 C2 C3 C4 C5 C6 C8 B1 B4 B5 B6 B7 A1 A2 A3 A4 A5 A6 A7 A8 Sub-Mini-Hermet Non-Adjustable Omni Calibration Hydrostatic Pressure Test Inspection Report Compliance / Conformance Dielectric Test Insulation Resistance Typical Material of Wetted Parts Safety Certified to IEC 61508 (SIL) SOR products are certified to IEC 61508 for non-redundant use in SIL1 and SIL2 Safety Instrumented Systems for most models. For more details or values applicable to a specific product, see the Safety Integrity Level Quick Guide (Form 1528). 913-888-2630 Registered Quality System to ISO 9001:2008 5/6

SOR offers a full line of commercial-grade process instruments. echosonix Level Transmitters Level Level Temperature Pressure Temperature Pressure Flow Flow Process Instrumentation We Deliver Quality On Time SOR Inc. 14685 West 105th Street Lenexa, Kansas 66215 Phone 913-888-2630 Toll Free 800-676-6794 Fax 913-888-0767 SOR Europe, Ltd. Farren Court Cowfold West Sussex RH13 8BP United Kingdom Phone +44 (0) 1403 864000 Fax +44 (0) 1403 864040 SOR - China Room 903, No. 10 Building Wan Da Plaza No. 93 Jian Guo Road Chao Yang District Beijing, China 100022 Phone +86 (10) 5820 8767 Fax +86 (10) 58 20 8770 Registered Quality System to ISO 9001:2008 (03.12) 2012 SOR Inc. 6/6 Registered Quality System to ISO 9001:2008 913-888-2630