Certificate No.: lecex BVS X issue No.:1 Certificate history: Issue No. 1 ( ) Status:

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conform ity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Ex-d luminaire type dklk 23 (V-CG-S) GHG W. Flameproof enclosure 'd', Equipment dust ignition protection by enclosure 't' Dr. F.

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

slra IEC of Gonformity IECEx Cert f cate ü* t4

IECEx Certificate of Conformity

IECEx Certificate of Conformity

INTERNATIONAL ELECTROTECHNICAL COMMISSlON IEC Certification Scheme for Explosive Atmospheres

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Integrated Solutions Low Voltage Systems

srra, of Conformity IECEx Gert f cate ?-ot,b

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

INSTRUCTION MANUAL (ATEX / IECEx)

FLASHLIGHT ANSI STANDARDS

FLASHLIGHT ANSI STANDARDS

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Certificate of Compliance

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

Certificate of Compliance


Guide for hazardous areas

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

UL HAZARDOUS LOCATIONS SERVICES

Certificate of Compliance

Electrical Installations Design, Selection, Erection and Inspection

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Certificate of Compliance

OPTIBAR DP 7060 Supplementary Instructions

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Flameproof Manual Call Points Series MCP

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

Explosion-proof Immersion Heater Type D-8660

INSTRUCTION MANUAL (ATEX / IECEx)

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Australian/New Zealand Standard

INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME)

INSTRUCTION & SERVICE MANUAL

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

Survey of electrical equipment installed in hazardous areas on tankers

Inductive slot sensor

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

manual addendum DELPHI Ex

Dräger Polytron 5700 IR Detection of flammable gases and vapours

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

Certification Supplement Manual

AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection

Main switch current K: with main switch (optional)

Approved by: Document no.: EGT

LTFX Electric Tank Immersion Heaters Installation Instructions

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

User s Manual YTA610 and YTA710 NEPSI Certification

PANELBOARD PROTECTION ON A GLOBAL SCALE

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

OPTIWAVE X500 Supplementary Instructions

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

UL Electrical Equipment for Measurement, Control, and Laboratory Use; Part 1: General Requirements, Second Edition

Manual Power relay SR853

standards: standards:

Operating Instructions

Annubar Flowmeter Series

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Fixed Gas Detection System/Meridian CERTIFICATION

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

Explosion Proof Combination Signal db (A) / 5 Joule

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Transcription:

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx UL 13.0039U issue No.:1 Status: Current Certificate history: Issue No. 1 (2015-3-18) Issue No. 0 (2013-6-7) Date of Issue: 2015-03-18 Page 1 of 4 Applicant: Adalet/Scott Fetzer Co. 4801 W. 150th Street Cleveland, OH 44135 Electrical Apparatus: Optional accessory: Empty Flameproof Enclosures - XJ Series Type of Protection: Flameproof "d", Dust Ignition by Enclosure "tb" Marking: Ex d IIB + H 2 Gb Ex tb IIIC Db IP66-34 C to +100 C Approved for issue on behalf of the IECEx Certification Body: Position: Paul T. Kelly Principal Engineer, Global Hazardous Locations Signature: (for printed version) Date: 2015-03-18 1. This certificate and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body. 3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website. Certificate issued by: UL LLC 333 Pfingsten Road Northbrook IL 60062-2096

Certificate No.: IECEx UL 13.0039U Date of Issue: 2015-03-18 Issue No.: 1 Page 2 of 4 Manufacturer: Adalet/Scott Fetzer Co. 4801 W. 150th Street Cleveland, OH 44135 Additional Manufacturing location (s): Adalet/Scott Fetzer Co. 4300 Windfern Road Suite 200 Houston, TX 77041 This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079-0 : 2011 Edition: 6.0 IEC 60079-1 : 2007-04 Edition: 6 IEC 60079-31 : 2008 Edition: 1 Explosive atmospheres - Part 0: General requirements Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" Explosive atmospheres Part 31: Equipment dust ignition protection by enclosure 't' This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above. TEST & ASSESSMENT REPORTS: A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in Test Report: US/UL/ExTR13.0039/00 US/UL/ExTR13.0039/01 Quality Assessment Report: US/ETL/QAR11.0002/02 US/UL/QAR08.0003/05

Certificate No.: IECEx UL 13.0039U Date of Issue: 2015-03-18 Issue No.: 1 Page 3 of 4 Schedule EQUIPMENT: Equipment and systems covered by this certificate are as follows: The XJ Series of cast enclosures constructed of Aluminium or 316 Stainless Steel for use with threaded covers, containing specifications ofr threaded conduit entries and other threaded entries for various sized auxiliary operators. The covers are flat and may also include a glass viewing window that is cemented and mechanically retained in place. Please see Annex for Nomenclature and Schedule of Limitations for Ex Components. CONDITIONS OF CERTIFICATION: NO

Certificate No.: IECEx UL 13.0039U Date of Issue: 2015-03-18 Issue No.: 1 Page 4 of 4 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above): Issue 1: Addition of manufacturing location. Annex: Annexe for IECEx UL 13.0039U.pdf

Annex for IECEx UL 13.0039U Type Variants Covered By the Approval: XJ D HX 6 N4 I II III IV V I. Enclosure Material and Type XJ-Series Designation II. III. IV. Enclosure Cover D, DF, DA, HA, HB, HC, K, KA, L, M, MA, MC, N6, N12, S, T, WH, WT, X, DFGC, DGC, HAGC, HBGC, HCGC, KGC, KAGC, LGC, MGC, MAGC, MCGC, NGC6, NGC12, TFGC, TGC, WHGC, WTGC, XGC. Marking Designation HX- (Class I, Groups B, C, and D; Class I, Zone 1, IIB+H 2 ) Enclosure Size Blank- Standard 6 6 inch (only available on XJN and XJNGC) 12 12 inch (only available on XJN and XJNGC) V. Environmental Designation N4- Type 4 Rating N4X- Type 4X Rating Temperature Range The ambient temperature range is -50 C to +100 C for use with a silicone o-ring and a solid cover. The ambient temperature range is -34 C to +100 C for use with a Nitrile Buna N o-ring and either Adaseal or Adaseal II. Installation Instructions No temperature tests were conducted as the enclosure is certified as an empty Ex component. The service temperature of the enclosures is based off the ambient temperature range of -50 C to +100 C for silicone o-rings. The service temperature of the enclosures with glass windows is based off the ambient temperature range of -34 C to +100 C for Nitrile Buna N o-rings, Adaseal window cement, and Adaseal II window cement.

Schedule of Limitations for Ex Components The approval applies to equipment without cable glands. Only cable glands certified for protection types d, tb, and have an IP66 rating may be used. For enclosure outline dimensions, conduit/cable layout, and conduit/cable drilling and tapping instructions, refer to supplied datasheet. To minimize the risk of electrostatic charge, provisions shall be made for adequate grounding and equipment shall be installed in such a manner so that accidental discharge shall not occur. Refer to supplied enclosure drawing for conduit/cable entry locations and sizes. Additional copies may be obtained from the factory. Include the enclosure serial number with any request. Oil-filled circuit breakers and contactors shall not be used. Rotating machines, or other devices which create turbulence, shall not be incorporated. The Hazardous Location Solutions reducers shall not be used for the direct inter-connection of enclosures. Only one Hazardous Location Solutions reducer shall be used with any single cable entry on the associated equipment. All conduit sealing fittings must be certified as flameproof d, dust ignition protection tb, and have a minimum IP66 rating equal to the marking on the enclosure. All unused device openings must be fitted with a certified close-up plug with protection types d, tb, and have an IP66 rating. The content of the Ex component enclosure equipment may be placed in any arrangement provided that an area of at least 40% of each cross-sectional area remains free to permit unimpeded gas flow and therefore, unrestricted development of an explosion. Enclosures shall be installed to a flat rigid surface using the mounting means provided. The end user shall provide earthing/bonding means as necessary.