BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

Similar documents
BS EN ISO : 2010

BS EN ISO : 2010

BS EN ISO : 2010

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions

BS 476: Part 6: 1989+A1:2009

BS 476: Part 6: 1989+A1:2009

BS EN : 2001 & IEC :2000

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

NF X : Parts 1, 2, 3, 4 & 5

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Review Fire Test Report

IMO Resolution MSC 61(67): Annex 1: Part 2

EN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 13 th October Test Sponsor: Tapco Europe Limited

BS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions.

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.

Title: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Smoke Seals in Accordance with BS 476: Part 31, Section 31.

Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy

The Fire Resistance Performance Of Timber Or Mineral Composite Based Insulated Doorsets When Fitted With D & E Architectural Hardware Spring Hinges

Title: Indicative fire test. WF Report No: /A. Prepared for: Hoody Speaker Hoods Ltd

25 th November Title:

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

Fire Test Reports for Interpon D Powder Coatings

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

Analysis Report

BCTC CARPET TECHNICAL CENTRE

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

Title: Fire resistance test utilising the general principles of BS 476: Part 20: 1987 on four specimens of Uninsulated Air Valves.

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

CERTIFICATE OF APPROVAL No ME 5085

CERTIFICATE OF APPROVAL No CF 5236 EMVER PAINTS INDUSTRIES LLC

Test Report: ICL/CR15/11/087

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy

Test Report: ICL/H18/9039 Rev 1

Analysis Report

EN 1155:1997 TESTS OF : PERKO R106 FS CONCEALED FIXED ELECTRICALLY POWERED FREE SWING DEVICES FOR SWING DOORS. Leopold Street, Birmingham.

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

ASSESSMENT REVIEW. Review of Assessment Report WFRA C91415

TFI Report Classification

Classification of Fire Performance of Wall and Ceiling Lining Materials

TFI Report Reaction to fire test

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

Report VNLF Test Report

Exova Warringtonfire - Expert Witness Directory 2018

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

CERTIFICATE OF APPROVAL No CF 5635 P3 SRL

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

Test Report No: ICL/H17/7967

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Australian Standard. Methods for fire tests on building materials, components and structures

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

The Train Now Arriving At... Harmonised Fire Safety For European Rolling Stock

TEST REPORT DATE: TEST NUMBER: DESCRIPTION OF TEST SAMPLE

Test report. NanoPhos coating system EPR and EEN. Name of client: NanoPhos SA. Date: Pages: 5 Encl.: 1 Ref: BP / KTO

New European Fire Testing Classification for Construction Products

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

FTSG RESOLUTIONS. This document of FTSG resolutions was issued by the Company Secretary 20 July 2012.

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Web:

Test Report No. AJD Date: JUN.09, 2013 Page 1 of 6

EU DECLARATION OF CONFORMITY (Doc) issued in accordance with the MARINE EQUIPMENT DIRECTIVE (MED) and EU/US MRA

Loss Prevention Standard

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Additional reaction to fire classification report No H

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

PUBLIC SUMMARY REPORT OF THE EGOLF EN 13823

Centrum stavebního inženýrství a.s.

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

CAN/ULC-S102 Surface Burning Characteristics of "Digitally Printed Aluminum Siding" Coated Aluminum

Abrasion Resistance of Fluoropolymer and polyester Coatings

ISO 5657 INTERNATIONAL STANDARD. Reaction to fire tests Ignitability of building products using a radiant heat source

Testing coated fabrics

Reaction to fire classification report No C-rev.1

+ = FIRE LABORATORY INTRODUCTION. APPLUS+ LGAI - Our company history. High Technology Knowledge. Customer Confidence. Branding

~ 0."0... DESCRI PT ION OF TEST SAM PLE

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Reaction to fire classification report No C

Report on Public Input June 2014 NFPA 101

ASTM E662 TESTING FOR COLE MOTORSPORTS/CM RACING PRODUCTS ON WINDSHIELD TEAROFFS ON ¼ GLASS VTEC # TESTED: MARCH 27, 2009

ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process

BUSHFIRE TEST ON GLAZED VERTICAL ELEMENTS

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

ISO INTERNATIONAL STANDARD

CERTIFICATE OF APPROVAL No CF 136

SHAW CONTRACT DESCRIPTION OF TEST SAMPLE

ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

Transcription:

Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com BS EN ISO 92391: 2002 Fire Tests For Determination Of The Burning Behaviour of Floorings WF Report Number 185968 Date: 16 th November 2009 Test Sponsor: Altro Limited

Page 2 of 9 Exova Warringtonfire Test Report No. 185968 BS EN ISO 92391: 2002 Reaction To Fire Tests For Floorings Part 1: Determination Of The Burning Behaviour Using A Radiant Heat Source Sponsored By Altro Limited Works Road Letchworth Herts SG6 1NW

Page 3 of 9 CONTENTS PAGE NO. TEST DETAILS...4 DESCRIPTION OF TEST SPECIMENS...6 TEST RESULTS...7 SIGNATORIES...8 Table 1...9

Page 4 of 9 Test Details Purpose of test To determine the performance of specimens of a product when they are subjected to the conditions of the test procedure defined in the document BS EN ISO 92391:2002 Reaction To Fire Tests For Floorings Part 1: Determination Of The Burning Behaviour Using A Radiant Heat Source. The test was performed in accordance with the procedure defined in BS EN ISO 92391:2002 and this report should be read in conjunction with that Standard. Scope of test BS EN ISO 92391:2002 describes a European test procedure for assessing the burning behaviour, spread of flame and smoke development of horizontally mounted floorcovering systems exposed to a radiant heat gradient in a test chamber, when ignited with a pilot flame. The measurements provide a basis for estimating one aspect of fire exposure behaviour of floor covering systems. The imposed radiant flux simulates the thermal radiation levels likely to impinge on the floors of a building whose upper surfaces are heated by flames or hot gases or both, from a fire in an adjacent room or compartment. This method is applicable to all types of floorcoverings such as textile carpet, cork, wood, rubber and plastic coverings as well as coatings. Results obtained by this method reflect the performance of the total floor covering system as tested. Modifications of the backing, bonding to a substrate, underlay, or other changes to the system may affect the test results. The test is intended for regulatory purposes, specification acceptance, design purposes, classification, or development and research. Fire test study group/egolf Instruction to test Provision of test specimens Conditioning of specimens Certain aspects of some fire test specifications are open to different interpretations. The Fire Test Study Group and EGOLF have identified a number of such areas and has agreed Resolutions which define common agreement of interpretations between fire test laboratories which are members of the Groups. Where such Resolutions are applicable to this test they have been followed. The test was conducted on the 26th August 2009 at the request of Altro Limited, the sponsor of the test. The specimens were supplied by the sponsor of the test. Exova Warringtonfire was not involved in any selection or sampling procedure. The specimens were received on the 14 th August 2009 Prior to test the specimens were conditioned to constant mass at a temperature of 23 ± 2 C and a relative humidity of 50 ± 5%.

Page 5 of 9 Number of specimens tested Exposed face Substrate A total of four specimens were tested. Initial tests were carried out on one specimen in the production direction and one specimen in a direction perpendicular to that direction to establish the worse case condition. The results of these tests indicated that the worse case was with the specimens in the production direction and the formal test was then completed with the specimens in that direction. The results given in this report relate to the formal test only. The decorative face of the specimens was exposed to the radiant heat of the test when the specimens were mounted in the test position. The specimens were tested with a 6mm thick fibre cement board substrate present.

Page 6 of 9 Description of Test Specimens The description of the specimens given below has been prepared from information provided by the sponsor of the test. All values quoted are nominal, unless tolerances are given. General description Poly vinyl (PVC) floor covering loose laid upon a 6mm thick fibre cement board substrate Product reference Altro XpressLay Generic type Polyvinyl chloride (PVC) Name of manufacturer Altro Limited Overall thickness 2.2mm (stated by sponsor) 2.43mm (determined by Exova Warringtonfire) Floor covering Overall weight per unit area 2.6kg/m 2 (stated by sponsor) 2.7kg/m² (determined by Exova Warringtonfire) Colour reference Black Flame retardant details See Note 1 Trade name NT D4 604 Generic type Fibre cement board Substrate Name of manufacturer Scheerders van de Kerkhove (SVK) Overall thickness 6mm Overall weight per unit area 1800kg/m³ Flame retardant details The product is inherently flame retardant Brief description of manufacturing process of Spread Coating Of PVC Plastisol the floor covering Note 1 The client is unwilling to provide this information.

Page 7 of 9 Test Results The test results relate to the behaviour of the test specimens of a product under the particular conditions of test; they are not intended to be the sole criterion for assessing the potential fire hazard of the product in use. The test results relate only to the specimens of the product in the form in which they were tested. Small differences in the composition or thickness of the product may significantly affect the performance during the test and may therefore invalidate the test results. Care should be taken to ensure that any product which is supplied or used is fully represented by the specimens which were tested. The distance between the flame front and the zero point at 10 minute intervals together with the observations recorded during the tests in respect of each specimen tested, are given in Table 1. In accordance with the procedure defined in BS EN ISO 92391:2002, the following results were obtained: Average maximum flame front distance = 12.7cm Average critical radiant flux = 11.0kW/m 2 Average smoke development = 210.67% min Average maximum light attenuation = 56.47% Validity The specification and interpretation of fire test methods are the subject of ongoing development and refinement. Changes in associated legislation may also occur. For these reasons it is recommended that the relevance of test reports over five years old should be considered by the user. The laboratory that issued the report will be able to offer, on behalf of the legal owner, a review of the procedures adopted for a particular test to ensure that they are consistent with current practices, and if required may endorse the test report. This report may only be reproduced in full. Extracts or abridgements shall not be published without permission of Exova Warringtonfire.

Page 8 of 9 Signatories Responsible Officer D. J. Owen * Approved T. Mort * Senior Technical Officer Authorised C. Dean * Operations Manager * For and on behalf of Exova Warringtonfire. Report Issued: 16 th November 2009 This version of the report has been produced from a.pdf format electronic file that has been provided by Exova Warringtonfire to the sponsor of the report and must only be reproduced in full. Extracts or abridgements of reports must not be published without permission of Exova Warringtonfire.

Page 9 of 9 Table 1 SPECIMEN NO. 1 2 3 DISTANCE (cm) TIME TO TRAVEL TO INDICATED DISTANCE (minutes : seconds) 5 2:08 2:09 2:09 10 2:34 2:32 2:34 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 Maximum flame front distance (cm) 13.0 13.0 12.0 Critical radiant flux (kw/m 2 ) 10.9 10.9 11.1 Smoke Development (%.min) 196.32 219.04 216.65 Maximum light attenuation (%) 52.40 60.64 56.37 Specimen Number 1 2 3 Flame front distance at 10 min (cm) 3.0 3.0 3.0 Flame front distance at 20 min (cm) Flame front distance at 30 min (cm) Radiant flux at 10 minutes, Rf 10 (kw/m 2 ) 11.3 11.3 11.3 Radiant flux at 20 minutes, Rf 20 (kw/m 2 ) Radiant flux at 30 minutes, Rf 30 (kw/m 2 ) Observations of the burning characteristics of the specimens during the testing exposure In the case of each specimen flash flaming occurred up to a maximum distance of 210mm.

Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0) 1925 655 116 F : +44 (0) 1925 655 419 E : warrington@exova.com W: www.exova.com Registered Office: Exova (UK) Ltd, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Reg No.SC 70429