Sabroe MatchMaster Program COMP1

Similar documents
TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

Compendium DES July 2016, CARN

Pressure Enthalpy Charts

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

IS0 INTERNATIONAL ORGANIZATION FOR STANDARDIZATION IS0 RECOMMENDATION R 916 TESTING OF REFRIGERATING. 1st EDITION. December 1968

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

THE FIVE W s SYSTEMES LMP MECHANICAL SUB-COOLING. I.G.A. GIRARD, TERREBONNE, Qc. INCREASED SYSTEM EFFICIENCY & LOWER ENERGY COSTS

The analysis proceeded by adopting the ASHRAE guideline for conventional HVAC chiller applications. This guideline is summarized in Table II.

HVAC Fundamentals & Refrigeration Cycle

Design, Manufacturing of Chilled Water System for Process Cooling Application

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]

Standard for 2006 Performance Rating Of Positive Displacement Ammonia Compressors and Compressor Units

Green economy with natural refrigerants

TEST REPORT #34. Compressor Calorimeter Test of Refrigerant DR-7 in a R-404A Scroll Compressor

COMMECH SERIES AIR CONDITIONING CSH SEMI-HERMETIC SCREW PACKAGES. ORIGINAL MANUFACTURED EQUIPMENT Commech Series New Models BA AUS

Basic Principals of Air conditioning By Dr. Esam Mejbil Abed

Figure 1: Schematic of internal heat exchanger vapor-injection cycle

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Technical Information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Technical Development Program

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

Specially Designed Waste Water & Sewage Pumps

RAC. Unit 1. Previous year Questions

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Refrigeration Systems


Case 6 Impact of Fouling Factor and Special Material for Heat Exchanger

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

TEST REPORT #32. System Soft-Optimized Test of Refrigerant D2Y60 in Air Source Heat Pump

DIGESTATE DRYER MDB-15 FOR USING UP TO 950 KWTH TO DRY SEPARATED DIGESTATE (OPTIONALLY EXPANDABLE TO KWTH)

Performance of an Improved Household Refrigerator/Freezer

pdfmachine trial version

Technical Information

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Transcritical CO2 Bottle Cooler Development

Thermodynamics: Homework A Set 7 Jennifer West (2004)

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

QUALITY PRODUCTS, INC. OIL-TO-AIR HEAT EXCHANGERS

Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Technical Bulletin (TB-0037)

Air Cooled Oil Coolers

DVU-HP. Integrated Reversible Heat Pump System

Commercial CO 2 Refrigeration Systems

Check valve Types NRV and NRVH

Tube-in-tube heat exchanger Type HE

Figure 1: Overview of CO 2 evaporator types

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec REFRIGERATION & AIR-CONDITIONING (Mechanical Engineering)

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Lecture # 5: SOLVED PROBLEM

EkoAir Heat exchanger selection manual.

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

Air flow management tutorial session. ACC Users Group 8 th Annual Conference Dallas, 4 October 2016 Sander Venema Howden Netherlands

HVAC-CHILLERS Bureau of Energy Efficiency, Indian Renewable Energy Development Agency, Devki Energy Consultancy Pvt. Ltd., 2006

REFRIGERANT CHANGEOVER

OIL SEPARATORS APPLICATIONS

CAP SERIES SEWAGE AND WASTE WATER PUMPS

Technical Information

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

The Refrigeration Cycle

ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER

Cascade Refrigeration System for LPG Subcooling. Related Technical Data and Information for the Case:

[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

A Comparison Between Refrigerants Used In Air Conditioning

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Tube-in-tube heat exchanger Type HE

The Refrigeration Cycle

Technical Papers. 37th Annual Meeting. International Institute of Ammonia Refrigeration. March 22 25, 2015

System Drop-in Tests of R-134a Alternative Refrigerants ARM-42a and R-1234ze(E) in an Air- Cooled Screw Chiller and a Water-cooled Centrifugal Chiller

Dynamic Simulation of Liquid Chillers

Air cooled industrial chillers

GRUNDFOS DATA BOOKLET MTB. Centrifugal machine tool pumps 50/60 Hz

Application Engineering

MODERN TECHNOLOGIES AND LONG - TERM EXPERIENCE

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

MSRW MINI SERIES. Modular Water Cooled Scroll Chiller MSRW075 MSRW085 Nominal Capacity 73 to 1312 kw(r) Issue: 2.0 Date 07/08

Refrigerant Glide and Effect on Performances Declaration

RS-45 (R-434A) R22 REPLACEMENT AT ALL TEMPERATURES. U.S. EPA Certified NON-FLAMMABLE

Brazed heat exchangers

Low GWP Refrigerants for Air Conditioning Applications

Carnot. 2. (a) Discuss the advantages of the dense air refrigeration system over an open air refrigeration system?

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Water Cooled Condenser Using Nano Fluids

Midea VFD Centrifugal Chiller Technology

Summary of Research Activities. Eckhard A. Groll Professor of Mechanical Engineering


Chapter-8 Capacity Control of Refrigeration Systems

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

Impacts of room temperature on the performance of a portable propane air conditioner

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

Refrigeration Systems and Accessories

Suction Line Accumulators

Transcription:

Page 1 of 5 File : 250313Q_1 Ref : CMAD Page : 1 Prog : COMP1/104509 Print : MIE ver. 6.0.2900.2180 SINGLE STAGE COMPRESSOR compressor type SAB 233 S male drive refrigerant R 717 number of compressors 2.00 evaporating temperature 6.0 deg.c compressor load 100.0 % condensing temperature 53.0 deg.c drive shaft speed 2985.0 RPM (list) total suction superheat 0.0 K internal volume ratio optimal suction line superheat 0.0 K suction line loss 1.0 K total liquid subcooling 2.0 K discharge line loss 1.0 K total cooling capacity 3118.9 kw total shaft power req. 841.9 kw total heating capacity 3531. kw cooling cap./shaft power ratio 3.70 cooling cap./line power ratio 3.45 economiser type none side load none oil cooling system water cooling oil specifications PAO 68 354 oil cooler type XPSH 3HH- oil inlet temperature 69.0 deg.c 116/2/1 total oil flow 41.0 m3/h oil cooler load - actual 429.8 kw oil density 804.5 kg/m3 oil cooler load - min. cap. 12.0 % 284.9 kw oil specific heat capacity 2.27 kj/kgk oil separator (SC): OHU 07629 oil kinematic viscosity 38.9 cst number of oil 2.0 oil heat conductivity 0.139 W/m.K separators: oil weight percentage 100.00 % number of coalescers: 6 total charge of oil 720.0 litre oil separator load: 51.7 % oil separator speed: 0.32 m/s oil separator max. speed: 0.63 m/s discharge check valve 5in_Danfoss_Cold_Sta (1) (s): motor: Leroy/500kW/400V/50Hz/IP23/355M operating conditions: suction pressure 5.11 bar_a discharge pressure 22.67 bar_a suction temperature 5.87 deg.c discharge temperature 88.76 deg.c suction specific volume 0.2464 m3/kg disch. temp. at min. load 82.22 deg.c enthalpy difference (ref.) 1025.30 kj/kg discharge specific volume 0.0683 m3/kg suction side mass flow 3.0419 kg/s liquid density 561.1 kg/m3 swept volume 2972.0 m3/h pressure ratio (p2/p1) 4.44 NB: no sound level computation - sound "box" dimensions in error NB: user defined oil data! NB: motor efficiency is approximate only NB: non standard motor for this compressor - select adapter flange NB: design limits check OK Oil cooler notes: NB: selected oil cooler may be non-standard! Full load performance data for chillers and other refrigeration systems are according to ISO-R916. Measurement tolerances according to ISO-917. Data subject to change without notice.

Page 2 of 5 File : 250313Q_1 Ref : CMAD Page : 2 OIL COOLER (high stage) oil cooler type XPSH 3HH-116/2/1 number of oil coolers 2.00 total capacity 424.0 kw logarithmic mean temperature diff. 36.90 K total transfer coefficient 668.0 W/m2K inlet velocity - shell side 1.10 m/s outlet velocity - shell side 1.10 m/s inlet velocity - tube side 2.44 m/s outlet velocity - tube side 2.44 m/s primary side (temp.drop): plate-side refrigerant (354) PAO 68 percentage by weight 100.0 % inlet temperature 88.8 deg.c outlet temperature 68.6 deg.c total flow 41.0 m3/h pressure loss 9.00 m.b.g. fouling factor.000000 m2.k/w velocity 2.44 m/s density 798.9 kg/m3 specific heat capacity 2.306 kj/kg.k dynamic viscosity 23.737 Cpoise thermal conductivity 0.138 W/m.K secondary side (temp. rise): shell-side inlet temperature 30.0 deg.c outlet temperature 50.0 deg.c total flow 18.4 m3/h pressure loss 0.24 m.b.g. fouling factor.000098 m2.k/w velocity 1.10 m/s density 992.3 kg/m3 specific heat capacity 4.179 kj/kg.k dynamic viscosity 0.652 Cpoise thermal conductivity 0.629 W/m.K Oil cooler notes: NB: selected oil cooler may be non-standard!

Page 3 of 5 File : 250313Q_1 Ref : CMAD Page : 3 EVAPORATOR evaporator type EPSH 7HH-308/2/1 number of evaporators 1.00 primary side: primary refrigerant R-717 total capacity 3119.0 kw evaporating temperature 6.0 deg.c mean temperature diff. 10.70 K fouling factor 0.000035 m2.k/w connections in/out DN150 /DN250 inlet velocity - prim. side 0.20 m/s outlet velocity - prim. side 5.55 m/s secondary side: inlet temperature 30.0 deg.c outlet temperature 10.0 deg.c total flow 134.4 m3/h pressure loss 5.72 m.b.g. velocity 1.87 m/s density 998.3 kg/m3 specific heat capacity 4.184 kj/kg.k dynamic viscosity 1.003 Cpoise thermal conductivity 0.600 W/m.K inlet velocity - sec. side 1.87 m/s outlet velocity - sec. side 1.87 m/s min. wall temperature N/A connections DN150 special PHE output: no. of cassettes and type 1*154 H service transfer coefficient 2144.0 W/m2K design/rating mode design clean transfer coefficient 2465.6 W/m2K plate material AISI-316 refrigerant pressure loss 0.98 mbg plate thickness 0.7 mm margin 5.00 % max. pressure loss sec. side 10.00 mbg available liquid head 1.05 mbg primary side connection - in/out 1/2 quality of vapour 0.85 secondary side connection - in/out 1/1 excessive area 8.00 % NB: PAC - oversize liquid separator selected!

Page 4 of 5 File : 250313Q_1 Ref : CMAD Page : 4 CONDENSER condenser type CPSH 7HH-244/2/1 number of condensers 1.00 primary side: primary refrigerant R-717 total capacity 3531.0 kw condensing temperature 53.0 deg.c mean temperature diff. 11.80 K condenser liquid subcooling 2.0 K fouling factor 0.000020 m2.k/w secondary side: inlet temperature 30.0 deg.c outlet temperature 50.0 deg.c total flow 153.2 m3/h pressure loss 9.66 m.b.g. velocity 2.14 m/s density 992.3 kg/m3 specific heat capacity 4.179 kj/kg.k dynamic viscosity 0.652 Cpoise thermal conductivity 0.629 W/m.K inlet velocity - sec. side 2.14 m/s outlet velocity - sec. side 2.14 m/s special PHE output: no. of cassettes and type 1*122 H service transfer coefficient 2908.0 W/m2K design/rating mode design clean transfer coefficient 3344.2 W/m2K plate material AISI-316 refrigerant pressure loss 0.18 mbg plate thickness 0.7 mm margin 5.00 % max. pressure loss sec. side 10.00 mbg primary side connection - in/out 1/1 superheated vapour temp. 88.76 deg.c secondary side connection - in/out 1/1 excessive area 10.00 %

Page 5 of 5 File : 250313Q_1 Ref : CMAD Page : 5 plant load percentage 100.0 % plant cooling capacity 3118.9 kw plant heating capacity 3531.0 kw totalt shaft power consumption 841.9 kw total line power consumption 905.3 kw capacity/shaft power ratio 3.70 capacity/line power ratio 3.45 PLANT DATA