Failure Analysis System Procedure

Similar documents
Failure Analysis System Procedure 8" Z8-ZN8 SUBMERSIBLE PUMPS. Lowara. 1) Pump applications

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

QUICK PRIME INSTALLATION AND SERVICE MANUAL

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

V80-H Multistage Pump Instruction Manual

INSTALLATION, COMMISSIONING AND OPERATING MANUAL

Series 1140 and 1141 Temperature Regulators

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

QUICK PRIME INSTALLATION AND SERVICE MANUAL

LC Series - Light Commercial Pump Station Installation and Operation Manual

Lenntech. Tel Fax bar. Multistage Pumps.

INSTRUCTION AND REPAIR MANUAL

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

OPERATION & MAINTENANCE INSTRUCTIONS

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

Republic Blowers. Ring Blower Side Channel Blower Regenerative Owner s Manual

INSTALLATION MANUAL FOR ROTARY TWIN LOBE (ROOTS) BLOWERS / COMPRESSORS

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Trouble Shooting Guide FAA, 3-phase (D3631)

SELF-PRIMING JET PUMPS

Warranty Details page 2. Pump Description & Technical page 3 Specifications. Transportation, Storage & Installation page 4. Pump Maintenance page 5

TYPE VSM/VSMS VERTICAL SPACE MISER PUMPS

SIHI multi Modular multistage pumps

Submersible. Pumps Motors. 50Hz 12 Submersible Pump. Pumping Solution

CHIPPER PC1 INSTRUCTIONS FOR INSTALLATION OPERATION AND MAINTENANCE. Series 35

DOMINATOR IT - ISTRUZIONI ORIGINALI IN LINGUA ITALIANA

Horizontal Split Case Pumps Type U

Operating Instructions. Rotating Vacuum Filter Type VRF

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y VTP. Vertical Turbine Pump

Vertical Ring-section Pump WKTB. Type Series Booklet

POWER WASHER MODEL NO: JET 9000 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING: Do not use the machine without reading this manual PART NO:

380 Series Multi-Stage Centrifugal Pumps

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual

X1 series Submersible Drainage Pump

NEPTUNE Tubular MI Electric Immersion Heater

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

Turin LED Ceiling Fan

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

SUBMERSIBLE WATER PUMP. Model Nos. CSE1 - CSE1A - CSE2 - CSE2A CSD3- -CSD3A CSV1A - CSV2 - CSV2A - CSW1A OPERATING & MAINTENANCE INSTRUCTIONS

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

HOT WASHER MODEL NO: KING150

SUBMERSIBLE DIRTY WATER PUMP

This label warns for risk of electrical shock when failing to observe.

Pump WaterVISE, FloVISE

Full-line Product Overview

Series P. Installation & Maintenance. Materials: A - CPVC B - Polypropylene C - PVDF

Installation/Instruction Manual

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

MJC Cartridge Filter Unit Operation & Maintenance

Trouble Shooting Guide PWA, 3-phase (D10571)

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

Sethco Division. Polypropylene / PVDF Self Priming and End Suction Magnetic Drive, Seal-less Pumps

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

PENGUIN SERIES HSC PUMPS INTRODUCTION

INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE (GB)

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:

TYPE FSD KYOWA EXHAUST GAS SCRUBBER OPERATION MANUAL

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

ETP Series - Self Priming Pumps

Trouble Shooting Guide RAA, 1-phase (D3627)

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Trouble Shooting Guide PAA, 1-phase (D3731)

SIMSITE. Impellers. & Casing Rings PUMP SIMSITE. Never Corrode. Impellers. & Rings

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

DIRTY WATER SUBMERSIBLE PUMP

Full Range Systems. Mokon Troubleshooting Guide Model 311. Process/Water Loop. Problem Possible Cause Corrective Measure. Process pump will not start

Model T Professional Series 3/4HP 2 YEAR WARRANTY SEWAGE PUMP

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

SuperKlean Washdown Products

Pumps SELECTION OF A PUMP

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

PJ130S High Pressure Cleaner

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y SMF. Vertical Submersible Pump

Family Curve. Submersible Grinder Pumps 1¼" and 2" Discharge. Effluent/Grinder Pumps.

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

RING BLOW VFZ-e Standard Model Series

Turbo Stick Vac. OWNER S MANUAL Model EP V., 60Hz., 7.5 Amps.

SERVICE MANUAL. 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and Model

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges

MARLOW PUMPS RECIRCULATION

STORAGE, ERECTION, OPERATION AND MAINTENANCE MANUAL FOR CENTRIFUGAL FANS MODEL - MXE

Ceiling Sweep Fan Assembly Instructions

470 Series Stamped Stainless Steel Pumps

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S2 S4 S5 SS6 SS7 S8

FAIRBANKS NIJHUIS SOLIDS HANDLING PUMPS.

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

SAM TURBO INDUSTRY LIMITED

Transcription:

Failure Analysis System Procedure 6" Z6-ZN6 Submersible Electric Pump 1) Pump applications Water distribution; industrial washing; pressurization; irrigation; industrial system; fire fighting; reverse osmosis 2) Critical items of application 21) Liquid Max liquid temperature: from 20 C to 30 C depending from installation conditions and motor power - if liquid temperature is greater than limits, motor overheats Max amount of sand in water: 50 g/m^3 - excessive presence of sand generates wear of impellers and wear rings, so a decrease of performances Liquid must not be brackishwater, seawater or corrosive - corrosions are caused by incorrect applications (inadequate ground system, leakage current, stray current, unsuitable pumped liquid) and they cannot be inputed to product or constructive materials 1 1

22) Installation: Max depht of immersion: 150 m (OS6 motors), 250 m (L6C motors), 350 m (F6 motors): - an excessive depht of immersion causes over heating of motor Installation of non return valve at 10 m from delivery and another nonreturn valve for anyone of 30 50 m of pipeline: - lack or insufficient presence of nonreturn valve, generates a great water hammer, so damaging of pump It must be guarantee a minimum distance of 1 m between pump and bottom of well: - if pump is too near the bottom, it can suck deposited solid parts, witch obstruct the filter and damages the pump 23) Motor cupling Pump can be cupled with 6" encapsulated motors or oil filled motors with power from 3 kw to 37 kw 3) Inspection of defected product 31) Preliminary information To receveing of defected product, require of Customer: purchase date (if possible, confirmed by bill or sale slip); installation date; conditions of installation 32) External visual inspection External aspect of product Corrosion on metal surface or on welds (with little holing) are an indication of incorrect or unsuitable use (see 21, 22, and 23) and exclude an acknowledgment of technical warrant Product analyse stop and repair (if required) is made for a fee If there are not elements of objection, go on with inspections in 43 33) Preliminary inspections Data in plate: - type of product and code; - series number; - manufacturing date; Welds and dents in the jacket Integrity of lower suction casing 4) Disassembly and analysis Remove the filter: - check presence of sand or earth deposits 2 2

Unscrew sleeve lock screws, remove external sleeve and check: - upper head; - non return valve Unscrew impellers lock screw, so check conditions of: - upper support with bush bearing; - diffuser cover (if present) with wear ring; - diffusers and impellers Check the possible presence of foreign matters Remove initial spacer and lower support Remove the thrust washer and check his conditions Examine condition of shaft and coupling 3 3

5) Check list Type of problem Does not delivery water Low performance Noisy Further: Pump data Type: Code: Series number: Installation date: Manufacturing date: Liquid pumped: Temperature: Note: 6" submersible pump failure causes required for claim opening Where What Why 300 Total hydraulic 300 Low performance 106 Uncorrect assembly/testing of components 300 Wrong rating plate/packing 300 Total hydraulic 104 Noisy / locked / vibrate 106 Uncorrect assembly/testing of components 114 Hydraulic rotating part locked 403 Pump sleeve 400 Leak 106 Uncorrect assembly/testing of components 404 OR/Mechanical seal 400 Leak 106 Uncorrect assembly/testing of components 408 Pump shaft/joint 401 Broken/cracked 106 Uncorrect assembly/testing of components 600 Product 600 Wrong rating plate 106 Uncorrect assembly/testing of components packing 601 Wrong product document 200 Lack of technical / commercial information 602 Not acknowledgment of warranty 600 Out of legal warranty period 601 Product tampering 4 4

7) Faq Problem founded Pump does not start Possible causes of the problem Power supply problems: no power; unconnected cable or damaged; supply voltage too low; starting drop voltage too high; Fuses burnt Circuit breaker not calibrated 2 phases powered Mechanical seal stuck Stator slot interrupted Activation of level probes Excessive operating depht Hydraulic locked Faulty stator Pump does not delivery water Low performance Does not stops Noisy Starts and stops too frequently Runs slowly Depht of installation too low Delivery outlet clogged Clogged filter Delivery outlet clogged Clogged non return valve Wrong connections in the motor System leaks Dirty filter Wear of hydraulic part Wear of wear ring Pump run in the opposite way Wrong pump, undersized Level probe defected Leaks in system Motor bearings damaged Unbalanced hydraulic Impellers slides on diffusers Pump oversized Pressure switch not calibrated Liquid temperature too high Excessive power input Leaks in system Wrong windings connections inside the motor 5 5

Execessive power input Hydraulic locked Uncorrect voltage Windings defected Motor supplied with 2 phases instead of 3 Presence of sand or other foreign matters inside of pump Wrong pump Pump defected Motor bearings and/or thrust washer defected Liquid unsuitable Presence of foreign matters in pump 6 6

6) Failure tree (6" submersible pump) PUMP DOES NOT DELIVERY WATER LOW PERFORMANCE Uncorrect supply voltage Depht of installation too low Delivery outlet clogged Clogged non return valve Pump run in the opposite way Wrong pump undersized Clogged delivery outlet Clogged non return valve Wrong connections in motor System leaks Dirty fliter Wear of hydraulic part Wear of wear ring NOISY Motor bearings damaged Thrust washer damaged Unbalanced hydraulic Impellers slide on diffusers 7 7