Data Sheet. Humidity control products. Data Pack K Issued February

Similar documents
Transformer Breathers

Brownell Transformer Breathers

Electron Microscopy Sciences

DESICCANT AIR DRYERS. BD + CD + CD series

DESICCANT AIR DRYERS. BD + CD + CD series

Humidity Indicators CATALOG 95H. Sustaining Member

DRYAIRE DESICCANT SYSTEM MODEL 6760

A-DRY Heatless adsorption compressed air dryers

Instructions Parts List. 150 psi (1.03 MPa, 10.3 bar) Maximum Air Inlet Working Pressure

CD36-3D3M CD418-8D3M CD832-16D4M CD25-2D3M CD38-3D1M CD625-12D3M 09-13

ISO-9001:2008 DESICCATORS CATALOG. Phone: Fax: Web:

Vacmobile 20/2. Instruction manual OPERATION & SERVICE

Safety vacuum drying oven for flammable solvents

COMMERCIAL STRENGTH POLYMER MEDIA FILTER OWNERS MANUAL

Filters & Centrifugal Separators

One-Side Clear Active Barrier Packaging for Moisture Sensitive Medical Devices:

VD 53 - Vacuum drying oven for non-flammable solvents

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

Accessory Products

CD418-8D3M CD832-16D4M CD36-3D3M CD25-2D3M CD38-3D1M C D D 3 M

XL

Adsorption Compressed Air Dryer Heatless or heater regeneration

VAC-U-DRY VACUUM DEHYDRATOR

CLEARPOINT Heater. Compressed Air Filter Heater Based on Ohm Resistance

Dual Column Dehydrating Breather Manual

Instruction Manual April sitrans AS 100

Section 7: Cable Glands & Duct Seals.

SMT450. High Performance TOP LED

Downstream Equipment. Intelligent Air Technology

AQVA ULTRA Faucet Purifier AQ003-1 User s Guide

Desiccant Breathers: A Front Line Defense in the War on Contamination

Instruction Manual. IT20K, IT100, IT300 and IT800 Inlet Traps. A Issue F. ITC800 Inlet Chemical Trap. ITD20K Inlet Desiccant Trap

Desiccant Air Drying System

Product Data Sheet Adsorption Dryer DPS (A)

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

High quality compressed air from generation to application

BINDER Scientific Product Catalog

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Metal, ceramic, plastic package products

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

P-K MACH GAS-FIRED BOILER C1500H C2000H OUTDOOR BOILER KIT GUIDE

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

Commercial product range

Users Manual Pury 250e Gas Purification System

Dual Tower Heat Reactivated Desiccant Air Dryer

Product Data Sheet Adsorption Dryer DPS

Desiccant Air Drying System

Tanis Engine Dehydrator. User s Guide

Data Sheet. Self regulating process heating tapes RS stock numbers ,

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Republic Blowers. Ring Blower Side Channel Blower Regenerative Owner s Manual

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

Portable Purification zf04 Systems Models PVS 185, 600, 1200, 1800, 2700

Instructions. Duct Mount Accessory Q Rev: 11/

Micro/Ultra Filtration System StamoClean CAT 430

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

FCHM Hydromatic Pump Control Module

Installation instructions Air drying unit for Bubble Sensor OTT CBS. English

MC Series Gas-Fired Heating Appliance

Technical Ventilation

New Product Introductions 2011

PORT700CF Portable Fume Collector

IR15 Dual Gas Series Datasheet

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

AIR FORCE EXTREME LITHIUM-ION

IMPORTANT SAFETY INSTRUCTIONS

ADSORPTION DRYERS. For all applications which require perfectly dry compressed air : Advantages of "ALC" dryers :

MN908 No. 282C Replaces 282B LB7013

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION

INSTALLATION GUIDE KT-CDR2 & KT-CDR3. For COOLDOME ENCLOSURE SERIES

Owner s Manual. Terpene Trap CF 1000

Vertical Dryer Owner s Manual

White paper Compressed air drying

Assembly and Maintenance manual according to regulation DIN DV TB 310-MA, DV TB 330-MA DV TB 510-MA, DV TB 530-MA DV TB 560-MA

TECH REPORT 200: Use of Water Traps and Drying Filter with the FX-5000 Tension System. Document: Water Trap and Drying Filter Tech Report, Rev. 8.

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

MT4 MAX/MT4 MAX + Infrared Thermometer

ERGOMAX 7 INSTALLATION

IR25 Dual Gas Series Datasheet

INSTRUCTIONS & PARTS LIST FOR NO. 658, 660, 690, 697 SIOUX AIR RANDOM ORBITAL SANDER INCLUDES B, V, VV, & X SUFFIXES (SERIAL E )

ASPIRE Laboratory Aspirator

500 EX Fusion Compressor Series

BARRACUDA DUAL MOTOR VACUUM OWNERS MANUAL. IMPORTANT: READ OWNERS MANUAL CAREFULLY Please fill out & return your warranty card! CUDA26 MODEL# SERIAL#

The leader in gas dehydration & filtration

R.I.S. (Remote Intelligent Sensor)

Snifter. User Manual. Distributor

P/N CC-100. Coolant Circulator. Operation manual

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

Model gffoz Process Ozone Sensor (In-Line)

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION

CORPORATE. Compressed Air Treatment Process Water Chillers Aluminum Pipe Systems ULTIMATE ENERGY SAVING TECHNOLOGY

AIR SENTRY DESICCANT BREATHERS

Vacuum requirements and Beamline interface at the VUV-FEL User Facility

USER MANUAL. Jumbo series

DELTA FILTER. G 3/8 to G 2

Aeronex Gas Purification System Z2 Series

Transcription:

Data Pack K Issued February 2004 1502324768 Data Sheet Humidity control products Introduction A comprehensive range of humidity control products primarily intended for use in electrical/electronic enclosures etc. Due to variations in temperature, considerable amounts of humidity can occur within sealed enclosures. This can be a serious condition causing malfunction of equipment and, in extreme cases, internal moisture can cause an enclosure to rust from the inside. RS offers a large range of products to prevent or indicate the presence of humidity within an enclosure including desiccators, enclosure heaters, humidity indicators, differential relief valves, immersion proof breathers and drain plugs. Complementary to the very large range of RS moulded and steel sealed enclosures, these products will find many applications for solving humidity problems, thus preventing expensive down-time and servicing difficulties. Silica gel panel mounting indicating desiccators Figure 1 10g silca gel desiccator RS stock no. 838-726 Ø48 52 15 Ring Nut 50 Ø35 M38 x 1.5-6g Slot 3 wide x 3 deep 46 A range of panel mounting desiccators containing silica gel for protection against corrosion, dampness and contamination in electronic, electrical, telecommunications and computer equipment etc. The desiccators incorporate indicator papers which are blue when the desiccator is dry and turns pink when the maximum amount of moisture has been absorbed. They are available in 10g, g or 50g sizes. Ideally suited to prevent damage or malfunction in equipment subject to humidity or temperature variations. A powerful absorbing agent reduces and absorbs ingressed or in-built moisture to acceptable levels. A humidity indicator monitors saturation and indicates when reactivation is required. The desiccators can be reactivated for re-use at 120 C for four hours in a ventilated oven. Caution: They should be allowed to cool in a sealed container. Ø39 ±0.5

Figure 2 g silca gel desiccator RS stock no. 838-732 Figure 3 50g silca gel desiccator RS stock no. 838-748 Ø60 40 Ø82 37 15 Ring Nut 15 Ring Nut 50 50 Ø69 M72 x 1.5-6g Slot 3 wide x 3 deep 31 Ø73 ±0.5 Ø47 M50 x 1.5-6g Slot 3 wide x 3 deep 34 Ø51 ±0.5 Parameter RS stock no. 838-726 RS stock no. 838-732 RS stock no. 838-748 Desiccant content 10g g 50g Operating temperature -40 C to +70 C, reactivation +120 C Environmental protection Resistant to alcohols, ethers, hydrocarbons, weak acids and bases Typical application volume IP67 enclosure 10 litres litres 50 litres approx approx 6-9 months approx 6-9 months 6-9 months IP55 enclosure 10 litres litres 50 litres approx 3-6 months approx 3-6 months approx 3-6 months Reactivation 4 hours in a ventilated oven @ 120 C Caution: Allow to cool in a sealed container Maximum pressure 1 bar gauge Maximum vacuum 500 Torr (-5 psi) Maximum leak rate 1 3 10-2 cc/sec Humidity indicating level % RH @ 20 C and 50% RH @ 20 C 2Nm Packaging Metal foil laminate - do not open until required for use 2

Molecular sieves panel mounting indicating desiccators Ideally suited to prevent damage or malfunction in equipment subject to humidity or temperature variations. A powerful absorbing agent reduces and absorbs ingressed or in-built moisture to acceptable levels. The molecular sieves absorbing agent maintains an ultra low relative humidity for extremely sensitive applications. Molecular sieves desiccators cannot be reactivated. Figure 4 50g molecular sieves desiccator RS stock no. 838-776 Ø82 37 15 Ring Nut In certain types of equipment water vapour condensation may result in immediate equipment failure due to electrical short circuiting, visibility loss, insulation breakdown and construction material instability. The use of a molecular sieves desiccant is recommended when an equipment may be subject to immediate failure as a result of water vapour condensation. Molecular sieves desiccators are most suitable for applications where equipments and enclosures are subject to operation at low temperatures and water vapour condensation must not occur. An integral dual level humidity indicator signals when the desiccant is reaching and has achieved its absorption capacity by turning from blue to pink. RS offers two panel mounting desiccators for protection against corrosion, dampness and contamination in optical, electro-optical and high voltage equipment etc.. 15 Slot 3 wide x 3 deep 31 Ø73 ±0.5 Ø69 M72 x 1.5-6g Parameter RS stock no. 838-776 Desiccant content 50g Operating temperature -50 C to +110 C Environmental protection Resistant to alcohols, ethers, hydrocarbons, weak acids and bases Typical application volume IP67 enclosure 10 litres 50 litres approx approx 5-8 months approx 5-8 months IP55 enclosure 10 litres 50 litres approx 2-5 months approx 2-5 months Reactivation Reactivation not possible with molecular sieve desiccators Maximum pressure 1 bar gauge Maximum vacuum 500 Torr (-5 psi) Maximum leak rate 1 x 10-2 cc/sec Humidity indicating level 15% RH @ 20 C and % RH @ 20 C 2Nm Packaging Metal foil laminate - do not open until required for use 3

Humidity indicators Figure 5 Humidity indicators Ø27 24 Sight Window 3 Ring Nut 50 M16 x 1-6g Med Dia Knurl 14 M12 x 1-6H x 7 deep Two types of humidity indicators which can be used with the standard range of desiccators or when; desiccant, desiccant bags or dry gas is selected to maintain the internal humidity within an equipment or enclosure. The /50% RH indicator (RS stock no. 838-798) is suitable when silica gel is being used to control the internal humidity. The 15/% RH indicator (RS stock no. 838-782) is suitable when molecular sieves or dry gas is being used to control the internal humidity. The indicators are intended to be panel mounted and require a 17mm Ø clearance hole. Ø17 ±0.5 Parameter RS stock no. 838-782 RS stock no. 838-798 Humidity indicating level 15/% RH /50% RH Operating temperature -40 C to +70 C Environmental protection Resistant to alcohols, ethers, hydrocarbons, weak acids and bases Maximum pressure 1 bar gauge Maximum vacuum 500 Torr (-5 psi) Leakage Rate 1 x 10-2 cc/sec 2Nm Packaging Metal foil laminate - do not open until required for use 4

Double differential relief valve, (RS stock no. 838-811) Figure 6 Double differential relief valve 24 1502324768 Manual Overide Button 20 M x 1-6g Ø36 Flow Direction Slot 3 wide x 1.5 deep 14 max 1.5 min Washer Ring Nut A double differential relief valve for protecting enclosures from imbalance of internal or external pressure. Manufactured from polycarbonate and stainless steel, a manual override facility enables any pressure or vacuum imbalance to be equalised before enclosure entry or cover plate removal. They are ideal for the protecting of sealed enclosures that would otherwise be subjected to damage due to differential pressure from within or without. Typical applications are in airborne equipment, air cargo containers and other equipment subject to altitude or temperature change. The valve requires a.5mm Ø clearance hole. Parameter RS stock no. 838-811 Humidity 5 to 90% non-condensing Operating temperature -40 C to +70 C Opening pressure Outward 1 psi Inward 1 psi Nominal flow rate 200 l/min @ 0.5 psi above opening pressure Max. reverse leakage Less than 1cc per hour Environmental protection Resistant to alcohols, ethers, weak acids and bases 5Nm Ø.5 5

Immersion proof breather, (RS stock no. 838-805) Figure 7 Immersion proof breather Ø27 24 Breather Inlet 3 Ring Nut M16 x 1-6g Med Dia Knurl 14 M12 x 1-6H x 7 deep An immersion proof breather for use in enclosures, sealed keyboards, pressure sensitive instruments or equipment subject to driving rain and water. Membrane keyboards and similar pressure sensitive equipments are often required to operate under adverse environmental conditions such as temperature cycling, changes in altitude, driving sand and dust and even immersion under water. This has resulted in a requirement for a device which allows pressure equalisation but still enables the equipment to remain sealed against liquid water ingress. The immersion proof breather is able to withstand immersion up to 1 metre for 15 minutes provided the temperature differential between the head and the water does not exceed 15 C. Immersion breathers, by nature of their construction, only allow a maximum flow rate of approximately 150cc/minute @ 1 psi differential. They should not therefore be considered for rapid decompression applications. Parameter RS stock no. 838-805 Operating temperature -40 C to +75 C Environmental protection Resistance to alcohols ethers, hydrocarbons, weak acids and bases Technical performance Flow rates 10cc/min @ 3.5wg 50cc/min @ 11.0wg 100cc/min @ 18.5wg 150cc/min @ 29.0wg Max applications volume Typically 60 litres (bases on 20 C chnage) 2Nm Max. immersion depth 1 metre for 12 hours Filtration Protection against dust (0.5µm nominal) Ø17 ±0.5

Drain plug and panel bush adaptor (RS stock no. 838-827) A simple plastic drain plug which prevents the accumulation of liquid water which may encourage corrosion, mould, growth or obstructions if the accumulated water freezes. Ideally suited for enclosures as the panel bush adaptor enables the drain plug to be mounted and demounted from outside the equipment. An integral filter prevents limited dust ingress and insect intrusion. Typical applications are: where pneumatic controls are within an enclosure, giving rise to moisture formation due to the expansion from valve exhausts. Parameter RS stock no. 838-827 Operating temperature -40 C to +70 C Typical flow rate cc/min Environmental protection Resistant to alcohols, ethers, weak acids and bases Adaptor thread size M16 x 1-6g 2Nm (drain plug) Figure 8 Drain plug and panel bush adaptor Ø27 24 Breather Inlet Med Dia Knurl 14 4 Holes Ø3.5 on 37 PCD Adaptor Bush Gasket M12 x 1-6H x 7 deep M16 x 1-6g 38 M16 x 1-6g Ø27 38 3 1 12 7

RS Components shall not be liable for any liability or loss of any nature (howsoever caused and whether or not due to RS Components negligence) which may result from the use of any information provided in RS technical literature. RS Components, PO Box 99, Corby, Northants, NN17 9RS Telephone: 01536 201234 An Electrocomponents Company RS Components 1998