Advent Home Navigator Product Line Overview Advent Home Navigator Named Best Network Subsystem

Similar documents
PRODUCT CATALOG. Concord Family Product Catalog. December 1999

NetworX NX-548E Receiver Installation Instructions

Product Catalog 2nd Quarter 1997

Concord. Protection for everything you ve worked so hard to build. Concord security systems to safeguard your family and home.

Simplify. Secure. Your Home. Your Life. M1 Security & Automation Controls

P Zone Expandable Hybrid Security System

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

ITI Caretaker Basic Commands

Safewatch Pro 3000 System Manual

Installation Instructions. Contents. Installing Panel Backup Battery(s) About This Manual...1. Powering Up the Panel... 15

All tested. Easy Series Intrusion Control Panel Making security easy featuring wlsn* * wireless Local SecurityNetwork

WIRELESS CONTROLS & DETECTORS

Concord 4 Series Security Systems

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

security timeless design innovative products inspired technology

Concord 4 User Manual

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

Congratulations! This manual consists of four sections: SECTION 1 introduces you to the components of your CareTaker system.

UltraSync Modular Hub

The complete wirefree security alarm solution

Côr Home Automation. The Heart of a Smarter Home

DS7400Xi Addressable Control/ Communicator

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

PowerMaster. Expanding the Boundaries of Security. PowerG. Technology. with

CARETAKER PLUS: MOST FREQUESNTLY ASKED QUESTIONS. Which sensor programming group should I use for a wireless freeze sensor?

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel

VISTA-32FB. Commercial Fire/Burg/CCTV and Access Control Platform FEATURES: Designed to integrate seamlessly with CCTV, access

Integrated Security Solutions

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

Concord 4 Installation Guide

Interrogator 200 Audio Verification Module (AVM)

User s Manual. System Information... 3 Using the Touchpad Buttons... 3 General Operation... 4 Using Systems with Keyswitches... 4

Wireless Sensors. Security unplugged. Interlogix wireless sensors deliver reliable detection and flexible installation for multiple applications.

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

NX-10 wireless keypad. To wire or not to wire?

Wireless Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell s quick-install wireless devices, with their

Installation Instructions

Power Wave LCD Keypads. Users Operating and Programming Guide Version 2.00

GSM RFID VOICE Alarm System

One panel offers everything you want built-in

Simon XTi Quick Operation Guide

Product Recall Notification TX-4200 Wireless Personal Panic Device

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1

Integrated Security Solutions

VISTA 48DLCT HONEYWELL SECURITY

INSTALLATION GUIDE XTLN-WIFI PANEL

Supervised Security System Owner's Guide

Intrusion. Control Panels

OJD ITB No Attachment E Duress Alarm Equipment Specifications

System Overview. PC4020 v3.3

20% Build It Your Way. Flexibility and Control. The Smart Start Kit. Comfort at Your Command

ERS-3600B. PERS-3600B Personal Emergency Reporting System

Description Supervised Wireless Technology PRODUCT SPECIFICATION SHEET

The OmniPro II EN50131 and PD6662 Compliant Controller

Quick Reference Guide

Simon XT User Manual R-11 and R-11-CN P/N REV B ISS 13JAN11

Wireless Security System

/10 Rev A

Area Systems While the alarm bell or siren is sounding, enter your user code. The system silences the alarm bell or siren.

Security System. User Guide for the LED Command Center

Security System With Scheduling. User Guide. N5943-8V4 7/04 Rev A

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

LYNX Touch L5210 Series Security System

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

OmniPro II. Technical Sheet. DESCRIPTION

Easy Series Intrusion Control Panel. Selection Guide

Destiny Destiny Owners Manual

The Omni LTe EN50131 and PD6662 Compliant Controller

DESTINY 6100 SERIES SECURITY SYSTEM OWNER S MANUAL V1 12/01

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

VISTA-32FBPT. Commercial Fire and Burglary Partitioned Security Systems with Scheduling. User Guide /12 Rev. B

DESTINY OWNER S MANUAL

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

The Omni IIe EN50131 and PD6662 Compliant Controller

Rev C December Part Numbers: R Concord. User Instructions

Security designed for your lifestyle

Sintony 60 security meets design

USER'S GUIDE FA1220CV. 2-Partition Security System N7003-1V2 7/98

**** **** A B ARMED FIRE FIRE C D READY OFF AWAY STAY 2 3 MAXIMUM TEST BYPASS PULL INSTANT CODE CHIME. First Alert READY. * 0 # Professional

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

VISTA-128BP/VISTA-250BP/ VISTA-128SIA Enhanced Commercial Burglary Partitioned Security System With Scheduling User Guide K5895V5 4/09 Rev C

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216

IC60 Sintony 60 Intrusion Control Panel

Security System. User s Guide for the Text Command Center

SuperBus Hardwire Output Module (HOM) Document Number: Rev. D March 1999

Rev C June 2004 ZZZ*(6HFXULW\FRP. Part Number: Concord Ultra. Installation Instructions

CÔR HOME AUTOMATION HOME COMFORT, SECURITY & LIFE SAFETY

D3D Wi-Fi GSM Smart Alarm System -User Manual

$'(0&2 9,67$ 3DUWLWLRQHG 6HFXULW\ 6\VWHP 8VHU *XLGH N7003V3 5/04 Rev A

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Silencing an Alarm All/Perimeter and Home/Away Systems. Area Systems. What to do when a trouble tone is sounding

VISTA-128BPT/ VISTA-250BPT/ VISTA-128BPTSIA

LYNX Touch DYNAMIC, FULL COLOR TOUCHSCREEN SECURITY SYSTEM AND HOME CONTROLLER. Your Connected Home

System Introduction. 1.1 Specifications S E C T I O N 1

Rev C May GE Interlogix. Part No: R. CareGard. User Guide

CONTENTS. (User s Manual)

9,67$ 6(D 6\VWHP 6HFXULW\ 86(5 *8,'( N7229AUV2 12/99

Transcription:

Product Line Overview Advent Home Navigator Product Line Overview Advent Home Navigator Named Best Network Subsystem

Product Line Overview Advent Home Navigator System Protect the Homestead. Run the Household. Advent has it under control Advent Home Navigator is an integrated security and control system for the most demanding residential applications. The system accepts ITI wireless sensors and standard hardwire sensors, and controls lights and appliances for comfort and convenience. Tailored to Lifestyles Extensive if/then logic and scheduling capabilities allow Home Navigator to be specifically tailored to the homeowner s lifestyle. If a cleaning or gardening staff needs access, create a schedule for their user code to work only on certain days and times. The scheduling function can also be used to create specific lighting scenarios and arming levels for specially created modes such as Vacation or Workday. Advanced Speech Capability The advanced speech capability of Advent reassures the homeowner when the system is armed properly and provides an alert when it isn t. An extensive 800-plus word vocabulary communicates vital information clearly and effectively. It calls out the precise location and nature of any emergency so the homeowner knows exactly how to react. Sophisticated Telephone Control Advent s sophisticated telephone control makes it easy to monitor and control security from any touchtone phone including your cellular phone-at home or anywhere in the world. Any Touch-Tone phone can also serve as a panic button in an emergency. Staying in Contact Home Navigator can contact the homeowner via alphanumeric pager or cellular phone anytime there s an alarm. This feature is also ideal for working parents. They can be notified when children have arrived home safely and disarmed the system...and also if children have not arrived by a scheduled time. Comprehensive Standard Features Standard features such as 4 or 8 partitions, 100 or 250 user codes and 256 X10 device capability make this a complete security system. Voice prompts and a built-in help function reassure the end-user of proper system operation and make Home Navigator easy to set up and change. Home Automation A powerful home control system by itself, Home Navigator s 2-way serial automation interface module make it interoperable with Crestron and other home automation systems. According to Home Automation Association forecasts, the market for home automation sales will average 29% growth per year through 2005. Designed to meet market demand for integrated control of home automation, Advent Home Navigator allows dealers to take advantage of the industry s enormous growth potential.

Advent Home Navigator Advent Home Navigator Control Panels Zones Choice of panels: 132 or 250 zones 8 standard hardwire zones, expandable with SnapCards or Input/Output Modules Hardwire Expansion Expandable with the 8-Zone Input SnapCard, the 4-Zone Output SnapCard and the Combo Input/Output SnapCard Expandable with the SuperBus 2000 8 Zone Input Module and the 4 Relay Output Module Touchpads Two hardwire SuperBus 2000 Alphanumeric Touchpads are available, with liquid crystal or vacuum fluorescent displays (LCD or VFD). Also available are 2- and 4- Button Keychain Touchpads and HiTech Hand Held and Wall Mount Wireless Touchpads. Markets Custom installations Large applications New construction Approvals UL 985: Household Fire Warning System Units UL 1023: Household Burglar Alarm System Units UL 1637: Home Health Care Signaling Equipment 2 Standard Features Powerful 25 MHz, 16 bit processor with over 1 megabyte of RAM 4 partitions/8 partitions 100 user codes/250 user codes Up to 256 X10 devices Up to 32 event schedules per partition for lighting and arming User code validation by schedule True alphanumeric paging for latchkey and other functions Built-in Help function for user operation Network Buddy system Over 800-word vocabulary for voice and display Relay output programming Over 3 megabytes of flash memory, allowing downloadable upgrades Up to 62 bus devices 2,048 event buffer Supervised power LORRA header Seamless integration with Creston home automation system 25-watt voice status reports Extensive if/then programming On- and off-site telephone control with digitized voice feedback Individual light control Programmable from on-site alphanumeric touchpads or offsite using Advent Downloader software 2- and 4-wire smoke compatible Attack-proof metal enclosure Compatible with ITI s Learn Mode wireless sensors

User-Oriented Features 4 partitions (8 partitions in 250 zone model) Partitions can act as high-security independent systems, or as a global system divided into individual areas, such as in guest homes or apartments Schedules 32 weekly or one-time channel schedules per partition Multiple schedules can be established for a busy household User validation by schedule Access code levels Designate one of 8 appropriate access code authority levels for determined by user each system user, or create a global access code Voice and built-in help function The improved user interface provides ease of use User can hear or read directions for system operation (synchronized voice and text) Flexible system operation 4 arming levels with modifiers Light Control Up to 256 individual lights can be controlled via X10 System provides event and scheduled activation Can be turned on and off or dimmed using touchpad or telephone System can turn lights on automatically during an intrusion or fire Latchkey paging by user code and keychain touchpad Keychain touchpads can be designated as latchkey fobs (the lock button on the touchpad can initiate latchkey arming) Provide children a keychain touchpad and enable code-free notification of latchkey events 800-plus word vocabulary Detailed zone descriptions allow user to pinpoint exact locations Voice zone descriptors synchronize voice and display Attack-resistant enclosure Creates peace of mind Phone Control Monitor and control security from any phone, remotely or on-site Turn lights or appliances on and off remotely 3

Dealer-Oriented Features Automatic bus addressing Eliminates the need to manually set dip switches or enter the bus address on the keypad Avoids bus address conflicts and helps prevent errors Shortens installation time Improved device polling Increases the overall communication rates on the bus, allowing more modules (up to 62) Improves device response times 132 or 250 zones Fits virtually any size home 4 partitions/8 partitions Partitions can act as high-security independent systems, or as a global system divided into individual areas in common dwellings such as duplexes, triplexes or fourplexes. Each partition can have its own touchpad, sensors, sirens, etc. Wireless or hardwire Serves new installations or retrofits existing installations capability Large event history 2048 event history buffer allows data to be viewed at a later time, uploaded or printed out. Time and date are stamped. Plug-in Long Range Radio Provides plug and go connectivity for AlarmNet or SafetyNet header (LORRA) systems Network Buddy System Provides fully supervised reporting to another Advent system in case of communication failure provides redundancy A neighbor s panel can be added to the network for increased security Supervised power AC source and battery fully supervised and tested by panel at regular intervals Flash memory No more chips or boards to pull to upgrade software Download new operating system Voice prompts Voice prompts when programming Multiple levels of tamper protection Multiple levels of tamper protection touchpad access, remote phone access, phone line, antenna and equipment/sensor tampering Provides additional security benefits Phone control Remotely program using a PC and Advent downloader software Monitor and control security from any phone, remotely or on-site SnapCards Easy expansion cards snap in easily to panel 4

Comparison Chart Advent Home Navigator 132 Advent Home Navigator 250 Concord UltraGard Standard Hardwire 8 8 8 6 Zones Maximum Wireless 132 132 76 76 Zones Hardwire 124 242 68 70 Expansion Zones Partitions 4 8 2 1 5 User Codes 100 250 60 24 Number of Bus 62 62 16 8 Devices Word Vocabulary 800+ words 800+ words 220 words 41 words Standard Outputs/ 6/112 6/124 2/64 2/32 Max Outputs Event Log 2048 2048 100 32 Backup Battery 12 V, 7 or 17 Ah 12 V, 7 or 17 Ah 12 V, 4 or 7 Ah 12 V, 4 or 7 Ah Backup Battery 24 hrs 24 hrs 24 hrs 24 hrs Time Phone Numbers 25 25 9 2 SuperBus 2000 Compatible 2 & 4 Wire Smoke Compatibility Alphanumeric Paging Hot Plug Service Touchpads Automatic Bus Addressing Two-Way Voice Interrogator PN 60-471 Interrogator PN 60-471 Crestron Compatible Phone Control Lighting or Appliance Control SAW and Crystal Sensor Compatibility Interrogator 200 PN 60-677 w/phone Control & Voice Module w/line Carrier Trans. and PLC Card Interrogator 200 PN 60-677 w/line Carrier Transformer Crystal Only Crystal Only SAW or Crystal Crystal Only

6 Home Navigator Equipment Operational Equipment Radio Transceiver Module Batteries and transformers SnapCards Input or Output Modules Hardwire touchpads Wireless touchpads Advent Home Navigator Optional Equipment Printer Module Dual Phone Line Module Voice Siren 25/70 Volt Converter Card Interrogator compatibility for two-way voice listen-in/talk-back to a Central Station Radio Transceiver Module Adds wireless zone capability Up to 5 modules per panel 2500 open air range (plastic housing) 3500 open air range (metal housing) Can be located near panel or up to 4000 away Dual antennas provide spatial diversity Compatible with all Learn Mode crystal sensors Printer Module Allows connection of a parallel printer Prints out events as they occur SuperBus 2000 digital data bus technology provides fast and reliable data transfer Module also includes a UL 864 fire-rated zone input Dual Phone Line Module Allows the panel to switch panel event and alarm reporting between two telephone lines If the primary line fails, the panel instructs the module to switch to the second line Monitoring available on both lines Tamper protection can be added Voice Siren 25/70 Volt Converter Card Enables addition of 25 or 70 volt voice siren audio output Converts the panel s output to a 25 or 70 volt, 25 watt supervised audio output Card mounts inside panel enclosure and is powered from the panel voice siren signal

Advent Home Navigator System P/N: 60-562-02 132 Zone P/N: 60-562-05 250 Zone 7 Hardwire Touchpads Transceiver SuperBus 2000 2x20 LCD P/N: 60-803-01 SuperBus 2000 2x20 VFD P/N: 60-804-01 Transceiver P/N: 60-821-95 Transceiver P/N: 60-821-95 Closed View Wireless Touchpads Power 2-Button Keychain Touchpad P/N: 60-607-319.5 4-Button Keychain Touchpad P/N: 60-606-319.5 Class II Transformer P/N: 60-823 12 VDC 17.2 Ah Backup Battery P/N: 60-781 HiTech Hand Held Touchpad P/N: 60-597-95 HiTech Wall Mount Touchpad P/N: 60-453-10-95 Class I Transformer P/N: 60-830 12 VDC 7 Ah Backup Battery P/N: 60-680

8 Converter Cards Communication Options Voice/Siren 25/70V Converter Card P/N: 60-773 SuperBus 2000 Dual Phone Line Module P/N: 60-768 Interrogator Two-Way Voice P/N: 60-471 SnapCards Printer Module 8Z Input Snap Card P/N: 60-757 Combo Input/ Output SnapCard P/N: 60-756 4 Zone Output SnapCard P/N: 60-758 SuperBus 2000 Printer Module P/N: 60-783 Input/Output Modules X10 Modules SuperBus 2000 4 Relay Output Module P/N: 60-770 SuperBus 2000 8 Zone Input Module P/N: 60-774 X10 Lamp Module P/N: 13-403 X10 Appliance Module P/N: 13-079 X10 Universal Module P/N: 13-399 Advent Home Navigator Product Line Overview, 2001 Interlogix, Inc.

SuperBus 2000 2x20 Alphanumeric Touchpad Touchpads SuperBus 2000 Touchpads SuperBus touchpads provide complete on-site programming and operational control of the Advent system. Alphanumeric Displays The Alphanumeric Touchpads show a 2x20-character display (2 lines of text with 20 characters per line). The display, LCD or VFD, spells out in plain English whether the system is on or off and the level of protection it is armed to. The system has a large, 800-plus word vocabulary to communicate vital information clearly and allows you to program custom words to fit your customer s needs. Instead of giving a vague zone number, the display can show POLICE ALARM, PAT S BEDROOM WINDOW. SuperBus 2000 Enhancements SuperBus 2000 Alphanumeric Touchpads feature the enhanced ITI SuperBus standard. They automatically identify themselves to the control panel so the panel knows the touchpad type and capabilities. This eliminates the need for the installer to program device addresses and enables the panel to easily support a greater variety of peripheral modules. SuperBus 2000 also has better information throughput allowing peripheral devices to operate at faster speeds. 9 Adjustable Display and Volume The buttons on the touchpad light up when pressed and stay on for 15 seconds after the last one is pressed. The user can control the brightness of the display and also change the volume of the status voice messages from the system. Touchpad Features Built-in speaker to sound alarms, status sounds and button-press beeps. Panic buttons for police, fire, and auxiliary emergencies. Telephone touchpad format with backlit keys. Built-in Help feature Keychain Touchpad Keychain Touchpad The unique ITI Keychain Touchpad gives your customers the power to arm and disarm their Advent system from outside their home or business. Instead of racing out the door to beat an exit delay, the user can leave the alarm system off, casually exit, and then press the arming button on the Keychain Touchpad. When the user returns, he or she can simply press the disarm button on the Keychain Touchpad to turn the alarm system off. The convenient 4-Button Keychain Touchpad also allows remote light control, so the user never has to enter a dark house or building. Features include Recessed buttons to help prevent false alarms LED to confirm RF transmission Keychain ring The Keychain Touchpad is available in Crystal 2-Button Keychain Touchpad (no light control) Crystal 4-Button Keychain Touchpad

Sensors Advent s flexible design makes it compatible with most hardwire sensors and ITI s patented Learn Mode sensors. Each Learn Mode sensor has its own factory programmed identification code that is learned by the control panel, eliminating programming errors in the field. Burglary To protect against intrusion, theft, and violence, hardwire sensors and ITI Learn Mode wireless sensors can be added to the Advent system. Hardwire Surface Mount Magnetic Contact Mini-Surface Mount Magnetic Contact Rollerball Switch Contact Recessed Magnetic Contact Overhead Door Switch Glass Break Detector PIR/Microwave Motion Detector Wireless Standard Door/Window Sensor Micro Door/Window Sensor Long-Life Door/Window Sensor Slim Line Door/Window Sensor Recessed Micro Door/Window Sensor Shock Sensor Glass Break Sensor Sound Sensor PIR Motion Sensor Quik Bridge Repeater 10 Life Safety Sensors can also protect against the dangers of fire, carbon monoxide, and medical emergencies. Hardwire 2-Wire Smoke Detector 4-Wire Smoke Detector Wireless Smoke Sensors Heat Sensors Fire Pull Station Carbon Monoxide Sensor Water-Resistant Pendant Panic Sensor Pendant Panic Sensor Environmental Your customers can be warned of furnace failure before costly damage is done. Wireless Freeze Sensor Home Control Lights can come on automatically at scheduled times during the day, the system can be controlled from any touchtone phone, and appliances can be managed while your customer is away from home. Light Control Module Appliance Control Module Universal Module

SECURITY & LIFE SAFETY G ROUP CADDX ESL GBC ITI KALATEL SENTROL 2266 Second Street North North Saint Paul, MN 55109 800-777-5484 www.interlogixinc.com 2001 Interlogix, Inc. ITI, Advent, SuperBus, Learn Mode, SnapCard and Quik Bridge are trademarks of Interlogix, Inc. All other trademarks are property of their respective owners. Specifications subject to change. Some features are optional. Part Number 466-1882 Rev. A (Spec. sheets available in quantities of 50)