WIO200 Water In Oil measuring instrument

Similar documents
WIO200 Water in oil sensor

WIO 200B and WIOI200B Water in oil sensor

WIO500 and WIOI500 Water in oil sensor

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

Digital Display DS 52 in wall housing. Order no

OPTISENS TUR 2000 Technical Datasheet

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

DR. E. HORN GmbH / Schoenaich, Germany

Process Alarm Module RTA 421

Instructions for the fan motor control system, SILVER C

Snifter ATEX22 VERSION. User Manual. Distributor

METEOROLOGICAL INSTRUMENTS

SCHMIDT LED Measured Value Display MD Instructions for Use

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

HUM-M2 Humidity Sensor Module Description

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

RE-PR3-E-27 3-Phase Panel Mount 27kW

Instructions for the fan motor control system with integrated wiring terminals SILVER C

KM300 Carbon Monoxide Detection System Installation Manual

Technical Data. Dimensions

M-Sens 2. Online moisture measurement for solids. Operating Instructions. SWR engineering Messtechnik GmbH PART OF THE ENVEA GROUP

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

Hygro/hygrothermal transducers (hygrometric)

DOL 31 Speed Controller Technical User Guide

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

S304 and S305 Dust Emission Monitors. User Manual. Distributor

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

MC 31 Speed Controller Technical User Guide Code no GB

testo 315-1/2 Instruction manual 99 Washington Street Melrose, MA Phone Toll Free

Software Version 2.01 LEVEL MONITOR MODEL 220

Electronic Temperature Controller 70304,

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

Certificate: _01 / 22 March 2013

METEOROLOGICAL INSTRUMENTS

I/A Series 716C 1/16 DIN Temperature Controller

EC3-X33 Stand-alone Superheat Controller Technical Data

Dissolved Oxygen Measurement liquisys M COM 223 / 253

Low Temperature Zirconia Oxygen Analyzer

Hygro/hygrothermal transducers (hygrometric)

Vibracon LVL-A* Level limit switch for liquids, compact design

S/601 Controller Installation Manual

Dissolved Oxygen Analyzers

Snifter. User Manual. Distributor

eed quality electronic design USER s MANUAL

Inductive slot sensor

Model 144H. Product Data Sheet , Rev DB February Content

Krypton K CL2. Measuring and control system for free chlorine. applications. description. Low maintenance by automatic sensor cleaning

Inductive Conductivity

Model 144H. Product Data Sheet , Rev DB February Content

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

02/11/2015

M5800 Pressure Transducer with Rotatable Display

UDC 700 Universal Digital Controllers and Indicator Specifications

Danfoss gas detection units

Incident resolution workflow

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

Analog Room Pressure Monitor RPC Series

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Gas cylinder scale Model GCS-1

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

OilSET-1000 (12 VDC)

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

Gas Detection System TOX ALARM DG2000-Garage

PRODUCT CONFORMITY CERTIFICATE

SET-2000 Hi Level/Oil

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Carbon Monoxide Transmitter

Series Temperature Controller Instruction Sheet

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Danfoss gas detection units

INSTALLATION AND OPERATING MANUAL

Temperature Controllers

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

The A-series Eletta Flow Monitor with local indication and analog output

ECO N DATE DESCRIPTION OF CHANGE CHG

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

SCAN200E USER S MANUAL

RS Pro Infrared Temperature Sensor

SET Installation and Operating Instructions. Level switch for one sensor

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

Technical Data. Dimensions

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Technical Data. Dimensions

M2500 Engine Controller Installation Manual

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

02/11/2015

UDC100 Universal Digital Controller Specifications

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Transcription:

WIO200 Water In Oil measuring instrument You have made the right decision by choosing a measuring instrument from PAJ Systemteknik. Many customers buy our high standard products every year. There are at least 7 good reasons for doing so: 1) Cost-performance ratio. Reliable quality at a fair price. 2) Extended warranty times of up to 3 years - depending on instrument. 3) We have the ideal solutions for your measuring tasks based on our expert experience gained over many years. 4) Our high quality standard is confirmed by the ISO 9001 certificate and GL approval (cert. no 75 956 09 HH). 5) Of course, our instruments carry the CE symbol required by the EU. 6) Calibration certificates for all relevant parameters. 7) Our after-sales service. Ask for more details. Page 1 of 12

TABLE OF CONTENTS Introduction... 3 Notes on safety... 3 Description... 3 Normal operation... 4 Failure indication... 5 Self test for alarm functions... 6 Diagram of instrument... 7 Technical data... 10 ordering data... 12 Page 2 of 12

INTRODUCTION NOTES ON SAFETY The conformity certificate confirms that this product fulfils the guidelines in accordance with 2004/108/EC and 2006/95/EC. Please read prior to operation Fuse protection of max. 350 ma by the customer if shield is attached. Do not exceed pressure range of >40 bar. Observe measuring ranges of sensor! The probes are damaged if overheated. Observe max. storage and transport temperature and max. operating temperature (e.g. protect measuring instrument from direct sunlight). Warranty claims no longer apply if the instrument is opened, in the case of inexpert handling or use of force. Adjustments or calibrations should be carried out by PAJ Systemteknik. DESCRIPTION Adherence to specific maximum water content in lubrication oil is required of motors to ensure long-lasting uninterrupted operation. The high quality standards in modern motor construction and operation require non-stop monitoring of water in oil concentration with alarm. Page 3 of 12

NORMAL OPERATION Water activity (a w ) provides the relative availability of water in oil where pure oil has an activity of zero and oil saturated with distilled water has an activity of exactly one. Under normal operation the WIO200 continuously supplies an output analogue signal of 4 to 20 ma corresponding to 0.01 to 1.00 a w. Alarm indications with 0.03 a w hysteresis via 2 relays are provided for each sensor. These alarm values were specified upon ordering can be found on the sensor serial label. Default alarm values are 0,5 a w and 0,9 a w. Assumes these alarm values: High alarm on at 0,50 a w (12 ma). High alarm off at 0,47 a w (11,5 ma) High high alarm on at 0,90 a w (18,4 ma). High high alarm off at 0,87 a w (17,9 ma). High high alarm will disable high alarm, thus only one alarm can be active. Page 4 of 12

FAILURE INDICATION Internal function failure will be indicated by activating both alarm relays at the same time, or indicated as defined in the NAMUR NE43. Internal failures includes: Sensor reading out of range. Sensor reading CRC error. Unstable Sensor reading. NAMUR NE43 is a German fault detection standard for 4-20mA analogue signals. It allows the user to know if there is a fault within the instrument, by sending analogue signal below 4mA and/or above 20mA. In accordance with NAMUR NE, the failure is indicated if: Fault indicated by analogue output =<2,0 ma Fault indicated if both relays are activated simultaneously Page 5 of 12

SELF TEST FOR ALARM FUNCTIONS On the WIO Sensor there is a button for testing the alarm functions. By pushing the button for 5 sec the high alarm relay turns on, and by pushing the button for 10 sec the high high alarm turns on. The alarms turn off 5 sec after they are activated. Test Button Mode Output Relay Analogue Output Un-pressed Normal operation Normal Normal Pressed >5 sec Test of high alarm Relay 1 high Relay 2 low Normal Pressed >10 sec Test of high high alarm Relay 1 low Relay 2 high Normal Page 6 of 12

DIAGRAM OF INSTRUMENT All measures are in mm. Page 7 of 12

INSTALLATION Screw in probe with ISO 228-1 G ¾ thread pressure-tight directly in the centre of the oil pipe where the measurement is to take place. The threads should be sealed with Loctite 271. The sensor should be mounted with max. 35 Nm momentum. Connect the cables from the WIO sensor to the Terminal box. Page 8 of 12

Connections (Electrical) : Connectors on Terminal Box: 2 x Connectors. 2 x metal Cable gland for 4,5 10mm Cables. Connectors on WIO Sensor: 2 x Connectors To sensor Outputs and Power To Terminal Box Inside the terminal box: Notice : It is allowed (but not nessasary) to connect screw terminal 13-4-20 ma to screw terminal 15 GND, thus creating common ground for the output and the power. Page 9 of 12

TECHNICAL DATA Measuring range: Accuracy: Resolution: Analogue output: 0,01 to 1,00 a w water content. ±0,03 a w for the range 0...1 a w water content. < 0,004 a w 4 to 20 ma (galvanic isolated) 0,01 to 1 a w water content linear. Max. Load (analogue outp.) < 500Ω. Alarm indications. Alarm indication via 2 x Alarm relays (NC). Relay Maximum DC Load breaking capacity: Self test: Protection class: Cables: Calibration: On the WIO Sensor there is a button for testing the alarm functions. By pushing the button for 5 sec the high alarm relay turns on, and by pushing the button for 10 sec the high high alarm turns on. The alarms turn off 5 sec after they are activated. IP66. 2 x Shielded cables with plugs on both ends, 2 meter long. Calibration made by manufacturer, in accordance to new oil, type Grade SAE 30/TBN 5-10. Re-calibration recommended with maximum 3 years interval. Power supply: Nominal supply 24 VDC ± 20%, max. ripple 10%. Page 10 of 12

Media for measurement: Lubrication oil: Grade SAE 30/TBN 5-10 Service temperature of media: Pressure range: 10 to 80 ºC. 0 to 40 bar. Ambient temperature: 0 to 85 ºC Storage/transport -20 to 85 ºC ambient temperature: Connection (mechanical): ISO 228-1 G ¾ male thread. After installation: The sensor has to be fully covered in oil for more than 5 minutes, before secure measurement is achieved. Startup time: Reaction time: Warranty: Approvals: 30 seconds. 10 minutes for 10% to 90% rise in water concentration. 2 years. The warranty expires if the device has been opened. Germanischer Lloyd (cert. no 75 956 09 HH). EC Declaration of conformity PAJ Systemteknik, Grundtvigs Allé 163, 6400 Sønderborg, herewith declares that the product of type WIO200 complies with the following directives: 2004/108/EC Electromagnetic compatibility 2006/95/EC Low voltage directive I/O: Level: Precision: Power Nominal 24 V DC ±20%, max. ripple 10% RMS. 2x Relay NC 1A 230VAC none Measurement out 4-20mA/ DC ±0,1mA max load < 500Ω. Button On/off none Page 11 of 12

Order item no: WIO Sensor system Order nr: A01-110-0100-00 Consists of: WIO Sensor Order nr: A01-110-0101-00 Terminal Box Order nr: A01-110-0102-00 Sensor cables 2 pcs. Order nr: A01-110-0103-00 Manual Order nr: D80-105-0008-00 Test certificate Order nr: Serial number on the sensor ORDERING DATA PAJ Systemteknik Grundtvigsallé 163 DK-6400 Sønderborg Tel: (0045) 74437181 Mail: paj@paj.dk Instruction manual en 111197-920 Rev. 1.09 Page 12 of 12