Eclipse AirHeat Burners

Similar documents
Eclipse AirHeat Burner

Design Guide No /01. RatioMatic Burners. RM Series Version 3.10

Design Guide 111 9/25/2008. Eclipse Winnox Burners WX Series Version 1

Design Guide /12/2008. Eclipse RatioAir Burners RA Series Version 1

Eclipse RatioMatic Burners

Eclipse ER Indirect Air Heater

Eclipse AirHeat Burners AH Series version 2.00 (Patent Pending)

Design Guide No. 330, 10/02 Immersion Burners

Eclipse ImmersoJet Burner

ECLIPSE AH-MA BURNERS. Air Make-Up Burners. Designed for trouble-free make-up or process air heating. Ready for the world

ECLIPSE INFORMATION GUIDE

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

INDUSTRIAL MICRODIFFUSION OIL BURNERS

Specifications of V-Line burners

PBG PACKAGED GAS BURNER

ECLIPSE INFORMATION GUIDE

OPERATING AND MAINTENANCE MANUAL

Eclipse PulsePak Burner

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

INDITHERM. Low temperature gas burners

V-Line. Nozzle-mix line burner

"NP" & "RG" AIRFLO. In-duct firing line burner

Series LV AIRFLO. In-duct firing line burner

APX. Nozzle-mix line burner

Lanemark Midco HMA2A Series Air Heating Burner and DB Duct Burner System Application Manual

INDITHERM. Low temperature gas burners

DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

DELTA-TE III. Nozzle-mix line burner

"HC" AIRFLO. In-duct firing line burner

Ecomax. Direct-Fired Self-Recuperative Metallic Gas Burner. Features

Power Flame Incorporated

POWER VENTER. Model: PVE Series

NMC Nozzle Mix Gas/Oil Combination Burners

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

INFRARED RADIANT HEATERS

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

LNB 1000 Series Low Nox Burner

CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

VeriFlame CE Burner Monitoring System

Specifications of MULTIFIRE burners

Series RE Infrared Heater

INSTALLATION AND OPERATION INSTRUCTIONS

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

Weishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA

Multi-Position Gas Furnaces

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Service Parts, Kits and Accessories

S150 S300 CONSTRUCTION HEATERS. Rev: August 15, 2008 SERVICE AND MAINTENANCE MANUAL No PLEASE RETAIN FOR FUTURE REFERENCE PRODUCTS

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

8+* Bulletin No November 1997

NMG NOZZLE MIX GAS BURNERS

Bosch Greentherm T9800 SE 199 Gas Tankless Water Heater

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

CINCINNATI, OH USA

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

Powerful intelligence. Breakthrough functionality. SV2 Series Intelligent Safety Shut-off Valve

MODEL CDB8 INSTALLATION INSTRUCTIONS

PVE SERIES POWER VENTER SYSTEM MANUAL

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

Eclipse 90 UV Scanner Model A Version 1

PACKAGED METALLIC BURNERS

Eclipse ER Indirect Air Heater

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

C1050ES Tankless Water Heater

Multi-Function Cooktop

Design and Application Details

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

WARNING FOR YOUR SAFETY CAUTION. gas-fired indoor gravity and power vented duct furnaces AIR H

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Stoneridge Fire Pit High Dining Table Assembly Instruction

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS

Eclipse Self-Check UV Scanner

GAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES

STR-Series Indirect-Fired Air Turnover Units

Distributed By: M&M Control Service, Inc Building Technologies

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

Installation, Operation & Service Manual

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

TUBE-O-THERM Low Temperature Gas Burners

MULTI POSITION GAS FURNACE

BGH Series Hot Surface Ignition Control

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

OPERATION, MAINTENANCE AND PARTS MANUAL

Ronald Sigmond 26 Oct 2016 FLAME MONITORING, GAS HANDLING SYSTEMS AND BURNERS

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

Installation Instructions

Direct Fired Heater Model AD Specification

Transcription:

Design Guide No. 135, 7/99 L00060 Eclipse AirHeat Burners AH Series Version 2.00 (Patent Pending) Eclipse Combustion

COPYRIGHT Copyright I999 by Eclipse Combustion, Inc. All rights reserved worldwide. This publication is protected by federal regulation and shall not be copied, distributed, transmitted, transcribed or translated into any human or computer language, in any form or by any means, to any third parties, without the express written consent of Eclipse Combustion, Inc., Rockford, Illinois, U.S.A. DISCLAIMER NOTICE We reserve the right to change the construction and/or configuration of our products at any time without being obliged to adjust earlier supplies accordingly. The material in this manual is believed adequate for the intended use of the product. If the product, or its individual modules or procedures, are used for purposes other than those specified herein, confirmation of their validity and suitability must be obtained. Eclipse Combustion, Inc. warrants that the material itself does not infringe any United States patents. No further warranty is expressed or implied. We have made every effort to make this manual as accurate and complete as possible. Should you find errors or omissions, please bring them to our attention so that we may correct them. In this way we hope to improve our product documentation for the benefit of our customers. Please send your corrections and comments to our Documentation Manager. LIABILITY AND WARRANTY It must be understood that Eclipse Combustion s liability for its products, whether due to breach of warranty, negligence, strict liability, or otherwise, is limited to the furnishing of such replacement parts and Eclipse Combustion will not be liable for any other injury, loss, damage or expenses, whether direct or consequential, including but not limited to loss of use, income of or damage to material arising in connection with the sale, installation, use of, inability to use or the repair or replacement of Eclipse Combustion s products. Any operation expressly prohibited in this Guide, any adjustment, or assembly procedures not recommended or authorized in these instructions shall void the warranty. 2

About this manual AUDIENCE PURPOSE AIR HEAT V2.00 DOCUMENTS This manual has been written for people who are already familiar with all aspects of a nozzle-mix burner and its add-on components, also referred to as the burner system. These aspects are: design/selection use maintenance. The audience is expected to have had experience with this kind of equipment. The purpose of this manual is to ensure that the design of a safe, effective, and trouble-free combustion system is carried out. Design Guide No. 135 This document AirHeat Data Sheet 135 Available for all AH v. 2.00 models Required to complete design & selection Installation Guide No. 135 Used with Data Sheet to complete installation Air Heat Price List No. 135 Used to order burners RELATED DOCUMENTS EFE 825 (Combustion Engineering Guide) Eclipse Bulletins and Info Guides: 710, 720, 732, 742, 760, 818, 832, 852, 854, 856, 610, 620, 630, 826, 820, 930, I-354. Eclipse AirHeat v2.00 - Design Guide No. 135, 7/99 3

DOCUMENT CONVENTIONS There are several special symbols in this document. You must know their meaning and importance. The explanation of these symbols follows below. Please read it thoroughly. Danger: Indicates hazards or unsafe practices which WILL result in severe personal injury or even death. Only qualified and well trained personnel are allowed to carry out these instructions or procedures. Act with great care and follow the instructions. Warning: Indicates hazards or unsafe pratices which could result in severe personal injury or damage. Act with great care and follow the instructions. Caution: Indicates hazards or unsafe practices which could result in damage to the machine or minor personal injury, Act carefully. Note: Indicates an important part of the text. Read thoroughly. HOW TO GET HELP If you need help, contact your local Eclipse Combustion representative. You can also contact Eclipse Combustion at any of the addresses listed on the back of this document. 4 Eclipse Air Heat v2.00 - Design Guide No. 135, 07/99

Table of Contents About this manual............................. 2 Audience....................................... 3 Air Heat Documents.............................. 3 Related Documents............................... 3 Document Conventions........................... 4 How to Get Help................................ 4 Table of Contents.............................. 5 1 2 3 Introduction................................... 6 Product Description.............................. 6 Safety......................................... 7 Capabilities...................................... 8 Operator Training................................ 8 Replacement Parts............................... 8 System Design................................. 9 Design.......................................... 9 Step 1: Burner Option Selection.................... 10 Step 2: Blower Option Selection.................... 12 Step 3: Control Methodology...................... 13 Step 4: Ignition System............................ 14 Step 5: Flame Monitoring Control System............ 16 Step 6: Main Gas Shut-Off Valve Train................ 17 Appendix...................................... 18 Conversion Factors............................... 18 Key to System Schematics......................... 19 Eclipse Air Heat v2.00 - Design Guide No. 135, 7/99 5

Introduction 1 PRODUCT DESCRIPTION Eclipse AirHeat v2.00 Burners are line type burners ideal for generating large volumes of clean, hot air. Applications include ovens, dryers, fume incinerators, and similar industrial equipment. Burners are constructed of aluminum burner bodies and diverging stainless steel air wings. The burner bodies supply fuel to the center of the air wings. The air and fuel mixture inside the burner is controlled to optimize emissions and efficiency. AirHeat v2.00 Burners are assembled from straight sections allowing for customized inputs. An integral combustion air blower can be ordered mounted on the back of the burner s steel case. By supplying the correct air volume and pressure to the burner, the blower allows stable operation over a wide range of duct velocities without installing a profile plate around the burner. Brackets are available for slot firing or duct mounting and flanges are available for continuous flange mounting. Right hand or left hand gas piping can be supplied with BSP or NPT connections. A reduced port fuel control valve can be supplied with a variety of control motor and linkage options. Ignition can be by direct spark or by spark ignited pilot. Flame rod flame supervision can be from either or both ends. Several air flow switches are also available factory mounted on the burner. AirHeat v2.00 Burners Burner with blower Burner less blower with inlet gas piping and fuel control valve and continuous mounting flanges. Burner less blower with inlet gas piping and fuel control valve and spark ignited pilot. 6 Eclipse Air Heat v2.00 - Design Guide No. 135, 7/99

Safety 2 INTRODUCTION SAFETY This section is provided as a guide for the safe operation of the AirHeat burner system. All involved personnel should read this section carefully before operating this system. Danger: The AirHeat burners, described herein, are designed to mix fuel with air and burn the resulting mixture. All fuel burning devices are capable of producing fires and explosions if improperly applied, installed, adjusted, controlled, or maintained. Do not bypass any safety feature; fire or explosion could result. Never try to light a burner if it shows signs of damage or malfunction. Warning: The burner might have HOT surfaces. Always wear protective clothing when approaching the burner. Note: This manual provides information in the use of these burners for their specific design purpose. Do not deviate from any instructions or application limits described herein without written advice from Eclipse Combustion. Read the entire manual before attempting to start this system. If you do not understand any part of the information contained in this manual, contact your local Eclipse representative or Eclipse Combustion before continuing. Eclipse Air Heat v2.00 - Design Guide No. 135, 7/99 7

CAPABILITIES OPERATOR TRAINING REPLACEMENT PARTS Only qualified personnel, with good mechanical aptitude and experience on combustion equipment, should adjust, maintain, or troubleshoot any mechanical or electrical part of this system. The best safety precaution is an alert and trained operator. Train new operators thoroughly and have them demonstrate an adequate understanding of the equipment and its operation. A regular retraining schedule should be administered to ensure operators maintain a high degree of proficiency. Order replacement parts from Eclipse Combustion only. All Eclipse Combustion approved, customer supplied valves or switches should carry UL, FM, CSA, CGA, and/or CE approval, where applicable. 8 Eclipse Air Heat v2.00 - Design Guide No. 135, 07/99

System Design 3 DESIGN Design structure The design process is divided into the following steps: 1. Burner Option Selection including: Burner Model / Size Selection Burner Style Air Supply Fuel Type Manifold Type Mounting Flange Burner Configuration Gas Pipe Connection Control Valve Ignition Type Flame Supervision Control Motor Air Flow Switch 2. Blower Option Selection including: Power Supply Frequency Blower Motor Type Blower Inlet Motor Orientation 3. Control Methodology including: Burner Control 4. Ignition System including: Ignition Transformer Trial For Ignition Ignition Gas Piping 5. Flame Monitoring Control System including: Flame Sensor Flame Monitoring Control 6. Main Gas Shut-Off Valve Train including: Component Selection Valve Train Size Eclipse Air Heat v2.00 - Design Guide No. 135, 7/99 9

Step 1: Burner Option Selection Step 1 describes how to select burner options to suit an application. Use the AirHeat Price List 135 and Data Sheet, 135 when following this selection process. Caution: Consult EFE-825, Eclipse Combustion Engineering Guide, or contact Eclipse Combustion if you have special conditions or questions. Burner Model / Size Selection Consider the following when selecting the burner size: Heat Input. Calculate the required heat input to achieve the required heat balance. Combustion Chamber Pressure. Consider the effects that large or varying chamber pressures have on burner performance. Altitude. Data supplied is based on burner operation at sea level. Combustion Air Supply. Combustion air should be fresh (20.9% O 2 ) and clean (without corrosives). Combustion Air Temperature. Changes in air supply temperature can affect the burner performance. The combustion air supply temperature should not exceed 250 F. Fuel Type. Variation in calorific value and density will affect burner performance. Burner Style AH v2.00 Burners are available in straight sections only. Air Supply AirHeat Version 2.00 burners can be ordered with or without a combustion air blower directly mounted to the burner. For remote blower applications, see page 12, Remote Blower Sizing. Fuel Type Gross Heating Value Btu/ft 3 (MJ/m 3 ) Specific Gravity Fuel Symbol Nat. gas CH 4 90%+ 1000 (40 ) 0.60 Propane C 3 H 8 2570 (103) 1.52 Stoichiometric Air/Gas Ratio ft 3 (m 3 ) air / ft3 (m 3 ) gas 10 25 Butane C 4 H 10 3250 (130) 1.95 33 BTU/ft 3 @ standard conditions (MJ/m 3 @ normal conditions) If using an alternative fuel supply, contact Eclipse Combustion with an accurate breakdown of the fuel components. Manifold Type AH v2.00 Burners are available with aluminum burner manifolds only. 10 Eclipse Air Heat v2.00 - Design Guide No. 135, 07/99

Mounting Flange Select the mounting hardware best suited to your application. Hardware is available for Duct Mounting, Slot Firing and Continuous Flange Mounting. Burner Configuration Select configuration. Left hand or right hand piping is available. Configuration is based on viewing the burner from the air inlet. Gas Pipe Connection Select the gas pipe connection. The piping, burner gas inlet, and fuel modulating valve (if selected) are threaded using the customer selected pipe thread option. Control Valve AirHeat Burners can be supplied with the following control options: Reduced Port Packaged. The control valve is sized based on burner input and fuel type. (See pages 3 & 4 of Data 135) Reduced Port Separate. Order when fuel control valve cannot be mounted directly to the burner due to system considerations. Less Control Valve. If not supplied by Eclipse, customer must supply a suitable fuel control valve capable of suppling fuel in accordance with the burners operating range. Ignition Type Ignition can be by direct spark or spark ignited pilot. Flame Supervision Flame supervision is by flame rod or UV scanner. Depending on configuration selected, flame sensor can be mounted at either or both ends of the burner. (Page 5, Data 135) Control Motor Select a control motor. Standard control motor options include various models which Eclipse will mount to the burner. Burners can be ordered with control motor bracket and mounting hardware only. Customer supplied control motors must conform to the these specifications: rotation not to exceed 2 rpm. minimum torque of 25 in-lb. (2,8 Nm) 90 stroke. continuous modulating or high/low modulating control. reversible direction of rotation. certain applications may require control motors with a limit switch or switches if: - the burner capacity is to be limited to fit an application. - there is a need to indicate a high and/or low fire butterfly valve (BV) position. Eclipse Air Heat v2.00 - Design Guide No. 135, 7/99 11

% Excess Air 10000 1000 100 10 Step 1: Burner Option Selection (continued) Step 2: Blower Option Selection Right hand blower motor. Control & Operational Zone 0.6"w.c. 1.5mbar 0.8"w.c. 2.0mbar Typical Fixed Air Control 1.0"w.c./2.5mbar 1.2"w.c. 3.0mbar 0 200 400 600 800 1000 Input (x 1000 BTU/hr/lineal ft.) 200 400 600 800 1000 Input (kw/lineal meter) Air Flow Switch The air flow switch provides a signal to the monitoring system when there is not enough air pressure from the blower. If a switch is selected, it will be factory mounted. Warning: Eclipse Combustion supports the NFPA regulation requiring, as a minimum standard for main gas shut-off systems, the use of an air pressure switch in conjunction with other system components. Note: Standard blower options are listed in Price List 135, additional blower options are available through Eclipse Combustion. Price and leadtime may vary. Power Supply Frequency Blowers are available with 60Hz motors. Motors have NEMA frames. Blower Motor Type Motor types include various options: voltages, single or three phase. Blower Inlet When selecting an inlet, consider the following: amount and size of particles in the air. cleanliness requirements of the process. Motor Orientation All AirHeat v2.00 Burners are assembled with a right-hand blower motor orientation. Remote Blower Sizing For remote blower applications, the blower should be sized to supply sufficient flow and pressure to the burner to ensure proper burner performance. Example Fire an AH0200 burner on natural gas at 800,000 Btu/hr/ lineal ft. resulting in maximum input of 1,600,000 Btu/hr at an air pressure drop of 1 w.c. In the chart at left, locate 800,000 Btu/hr/LF and read up to the 1 w.c. P curve and then left to determine the excess air percentage. In this case, 44% excess air. Step 1: Determine Air Factor (1+ excess air %) = 1.44 Input Step 2: Determine Fuel Flow ( Gross Heating Value* ) 1,600,000 = = 1,600 scfh 1000 Step 3: Determine Air Flow (Air Factor x Stoichiometric Air Requirement* x Fuel Flow). 1.44 x 10 x 1,600 = 23,040 scfh air flow. (* See Fuel Type Table on page 10.) 12 Eclipse Air Heat v2.00 - Design Guide No. 135, 07/99

Step 3: Control Methodology Turndown Method Input is normally controled by a motorized butterfly valve in the gas line to the burner. Heat Control Motor Combustion Air Blower Gas Flow BV Valve Gas Flow A control signal is sent from a process temperature controller (sold separately) to the control motor. (Refer to Bulletin 818C or contact Eclipse Combustion for further information on temperature controllers.) Set Point Process Controller Control Signal Control Motor Temperature Mechanical Linkage Process Gas Flow Gas BV The control motor modulates the gas butterfly valve (BV) which controls the fuel flow to the burner. Air pressure and flow in the burner body remain fixed throught the operating range. Modulation of fuel flow only, provides turndowns of 40:1 Warning: Do not use other control methods without prior approval from Eclipse Combustion. Eclipse Air Heat v2.00 - Design Guide No. 135, 7/99 13

Step 4: Ignition System Ignition Transformer For the ignition system, use a transformer with: secondary voltage 6,000 to 8,000 VAC. minimum secondary current 0.02 amps continuous. full wave output. DO NOT USE the following: twin outlet transformer distributor type transformer. Trial For Ignition It is recommended that low fire start be used. However, under certain circumstances AirHeats are capable of direct spark ignition at higher gas inputs. Most local safety codes and insurance requirements limit the maximum trial for ignition time (the time it takes for a burner to ignite). These requirements vary from one location to another; check your local codes and comply to the strictest codes applicable. The time it takes for a burner to ignite depends on the following: the distance between the gas shut-off valve and the burner. the gas flow conditions at start-up. The possibility exists where the low fire is too low to ignite the burner within the maximum trial for ignition time. The following options must be considered under these conditions: start at higher gas input levels. resize and/or relocate the gas controls. use spark ignited pilot. 14 Eclipse Air Heat v2.00 - Design Guide No. 135, 07/99

Step 4: Ignition System (continued) Ignition Gas Piping AirHeats are capable of ignition with either direct spark or spark ignited pilot. Direct Spark Ignition: Main Gas shut-off valve train Spark Ignited Pilot: When ordered, the pilot is packaged with the burner and includes an adjustable flow gas cock and pressure regulator. Main Gas shut-off valve train Pilot NC Caution: It is not possible to use a continuous or intermittent pilot. The pilot fuel flow should be interrupted after the trial for ignition period has expired. Eclipse Air Heat v2.00 - Design Guide No. 135, 7/99 15

Step 5: Flame Monitoring Control System Flame Rod The flame monitoring control system consists of two main components: Flame Sensor Flame Monitoring Control Flame Sensor Two types can be used on an AirHeat Burner: flame rod U.V. scanner Flame rods are available for all AirHeat Burner sizes. Further information can be found in: Info Guide 832 U.V. Scanner A U.V. scanner can be used on all AirHeat Burner sizes. Further information can be found in: Info Guide 852; 90 U.V. scanner Info Guide 854; straight U.V. scanner Info Guide 856; self-check U.V. scanner Flame Monitoring Control The Flame Monitoring Control processes the signal from the flame rod, or U.V. scanner, and controls the start-up sequence and the main gas shut-off valve sequence. Eclipse Combustion recommends the use of flame monitoring control systems which maintain a spark for the entire trial for ignition time when using U.V. scanners. Some of these flame monitoring models are: Veri-Flame; see Bulletin / Info Guide 610, 620, 630 Bi-Flame series; see Instruction Manual 826 Multi-Flame series 6000; see Instruction Manual 820 DO NOT USE: PCI Automatic flame monitoring Honeywell RM7890 series flame monitoring Flame monitoring relays which interrupt the trial for ignition when the flame is detected. Flame sensors which supply a weak signal. Flame monitoring relays with low sensitivity. 16 Eclipse Air Heat v2.00 - Design Guide No. 135, 07/99

Step 6: Main Gas Shut-Off Valve Train Component Selection Eclipse Combustion can help in the design of a main gas shutoff valve train that satisfies the customer and complies with all local safety standards and codes set by the authorities within that jurisdiction. Contact Eclipse Combustion for further information. Note: Eclipse Combustion supports NFPA regulations (two gas shut-off valves as a minimum standard for main gas shut-off systems). Valve Train Size Fuel pressure supplied to the burner inlet (Tap B ) must be 10 w.c. The valve train should be sized sufficiently to provide the specified pressure. Eclipse Air Heat v2.00 - Design Guide No. 135, 7/99 17

Appendix CONVERSION FACTORS Metric to English. From To Multiply By cubic meter (m 3 ) cubic foot (ft 3 ) 35.31 cubic meter/hour (m 3 /h) cubic foot/hour (cfh) 35.31 degrees Celsuis (ºC) degrees Fahrenheit (ºF) (ºC x 1.8) + 32 kilogram (kg) pound (lb) 2.205 kilowatt (kw) BTU/hr 3414 meter (m) foot (ft) 3.28 millibar (mbar) inches water column ( w.c.) 0.401 millibar (mbar) pounds/sq in (psi) 14.5 x 10-3 millimeter (mm) inch (in) 3.94 x 10-2 MJ/m 3 (normal) BTU/ft 3 (standard) 2.491 x 10-2 Metric to Metric. kilopascals (kpa) millibar (mbar) 10 meter (m) millimeter (mm) 1000 millibar (mbar) kilopascals (kpa) 0.1 millimeter (mm) meter (m) 0.001 English to Metric. From To Mulitply By BTU/hr kilowatt (kw) 0.293 x 10-3 cubic foot (ft 3 ) cubic meter (m 3 ) 2.832 x 10-2 degrees Fahrenheit (ºF) degrees Celsius (ºC) (ºF 32) 1.8 foot (ft) meter (m) 0.3048 inches (in) millimeter (mm) 25.4 inches water column ( wc) millibar (mbar) 2.49 pound (lb) kilogram (kg) 0.454 pounds/sq in (psi) millibar (mbar) 68.95 BTU/ft 3 (standard) MJ/m 3 (normal) 40.14 18 Eclipse RatioMatic v3.00 - Design Guide No. 110, 4/98

KEY TO SYSTEM SCHEMATICS These are the symbols used in the schematics. Symbol Appearance Name Remarks Bulletin/ Info Guide AirHeat Burner Main Gas Shutoff Valve Train Eclipse Combustion, Inc. strongly endorses NFPA as a minimum 756 Gas Cock Gas cocks are used to manually shut off the gas supply on both sides of the main gas shut-off valve train. 710 NC Solenoid Valve (normally closed) Solenoid valves are used to automatically shut off the gas supply on a bypass gas system or on small capacity burners. 760 Pressure Regulator A pressure regulator reduces gas pressure to a stable, usable pressure. 684 Automatic Gas Control Valve An automatic gas control valve adjusts gas flow to the burner based on control system requirements. 720 Eclipse AirHeat v2.00 - Design Guide No. 135, 7/99 19

Litho in U.S.A.