Similar documents
FIRE ALARM: BY OTHERS, IF REQUIRED.

FIRE ALARM: BY OTHERS, IF REQUIRED.

SINGLE CONVENIENCE OUTLET, WALL MOUNTED RECESSED +18" AFF

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL

Ho-Chunk Gaming THUNDERBIRD ENGINEERING, INC. MILWAUKEE: (414) MADISON: (608)

ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED

Leviton Combination Switch And Tamper Resistant Outlet Wiring Diagram

GARCIA GALUSKA DESOUSA Consulting Engineers

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS


SECTION LIGHTING CONTROLS

The following information shall become and form part of the contract documents.

PROJECT NO. CWA SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER

UBC Technical Guidelines Section Edition Access Control Page 1 of 5

LIGHT LEVEL REQUIREMENTS MINIMUM ACCEPTABLE FOOT CANDLES

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Renovate MCRC Facilities Great Lakes, IL

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

Library stacks and records storage 150 LB/SF live load

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

SECTION LOW VOLTAGE LIGHTING CONTROLS

Electrical System (N) PANELBOARD "L1" VOLTAGE: 208/120 A, 3P :MAIN C/B PHASE: 3 A :BUSSING WIRE: 4 :MOUNTING

CHAPTER 20 SERVICE EQUIPMENT

HMC ARCHITECTS 2495 Natomas Park Drive, Studio 100 Sacramento, California ADDENDUM NO. 3

PHOTOS. December 8, 2017

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

DEMOLITION GENERAL NOTES As-built conditions have been determined from Record Drawings (if they exist), field investigations (accessible areas and

A. This Section includes the following lighting control devices:

F. GENERAL REQUIREMENTS Electrical Design Criteria 2006 Edition 4/3/06 School District Palm Beach County Page-1 of 15

Electrical Design Guidelines Table of Contents

The following narrative outlines a conceptual electrical Scope of Work for converting the Phase 2 TRW Building to an Exhibition Hall.

Building Electrical System Overview

SECTION LIGHTING CONTROL DEVICES

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

L04 X01 X03 X01 R21A R21A F09 L27 R18 R16A R18 R21A KING 107 F09 F09 L27 D03A Z-38 KING 109 R21A R18 R16A R18 R21A F09 F09 X03 L27 F09 R21A R18 R18

SOUTHVIEW MEDICAL CENTER

Element D Services Electrical

POWER SOURCES MODEL NO. DESCRIPTION PRICE

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

A. This Section includes the following lighting control devices:

SECTION AUTOMATIC TRANSFER SWITCHES

Brighton Area Fire Authority

SECTION (16140) - WIRING DEVICES

Lindsay Frederick. Lighting + Electrical. Ron Dodson Faculty Advisor. Native American Cultural Center Arizona. Technical Report 2

Port of Portland Conveying Equipment Guidelines

Memphis Housing Authority High Rise Fire Alarm Upgrades. Questions from Contractors (Through Addendum #2) Communications Systems, Inc.

RFP Addendum 2 March 31, 2016

ENGINE GENERATORS AND ACCESSORIES

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

Related Sections: TBD. Effective Date: January 1, 2016

SECTION INTRUSION DETECTION SYSTEM

SECTION INTRUSION DETECTION

IN2 Lighting Control Devices

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

INDEX. Page 2 to 7 Electrical Specifications. Page 8 Electrical Schemes: Basement Plan. Page 9 Electrical Schemes: First Floor Plan

COUNTY OF KINGS KINGS COUNTY JAIL EXPANSION PHASE III

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS

F. GENERAL REQUIREMENTS Electrical Design Criteria 2009 Edition 11/23/2009 School District Palm Beach County Page-1 of 17

SECTION ADDRESSABLE FIRE ALARM SYSTEM

2009 ELECTRICAL CODE REQUIREMENTS

Technical II Report Electrical Systems

PART 4 ELECTRICAL STANDARDS

SPACE TYPE: JUDICIAL CHAMBER

RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS

CADDY CORPORATION. Utility Distribution Systems

UNIFIED FACILITIES GUIDE SPECIFICATIONS

LIGHTING CONTROL DEVICES

Architect s Project Number of 12 Fire Alarm/Smoke Detection Systems District Master Specs 2013 Edition

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Commercial Remodel/ Add On Rules and Regulations

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

DIVISION 16 BASIC MATERIALS, METHODS, AND REQUIREMENTS SECTION 16A-1

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

CARD ACCESS CONTROL SYSTEM

BASIC ELECTRICAL ENGINEERING FOR CE

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

Commercial Rules and Regulations

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Michigan State University DESIGN GUIDELINES. ELECTRICAL DESIGN Page 1 TABLE OF CONTENTS 1

DIVISION 16 - ELECTRICAL

SECTION FIRE ALARM SYSTEMS

Page 1 of General

NOTICE TO ALL FIRMS. Bid RFI Questions and Answers

ALBUQUERQUE PUBLIC SCHOOLS Facility Design & Construction / Maintenance & Operations ELECTRICAL STANDARDS DESIGN CHECKLIST

Town of Cicero Local Code Amendments

SECTION EXTERIOR LIGHTING

Changes to this Division since the last issuance are indicated with yellow highlighted text.

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST

Fire Sprinkler Plan Submittal Form

MEDICAL OFFICE BUILDING

Transcription:

I.C. Thomasson Associates, Inc. CONSULTING ENGINEERS 2950 KRAFT DRIVE, SUITE 500 NASHVILLE, TN. 37204 PHONE (615) 346-3400 FAX (615) 346-3550 www.icthomasson.com ICT PROJECT # 170647 HODGSON DOUGLAS landscape architecture planning. urban design 120 29th Ave. South, Nashville, Tennessee 37221 t. 615.327.4447 f. 615.321.3004 www.hodgsondouglas.com SYMBOL L L F SD DSD HD SD E FSD DH TS FS AFF AFG ABV ABC CLG EWC EM EX RW FBO GND R UON WH WP DESCRIPTION CHIME/FLASHING LIGHT COMBINATION MANUAL PULL STATION SMOKE DETECTOR DUCT-SMOKE DETECTOR (DAMPER) OR (EXHAUST) AUTOMATIC HEAT DETECTOR (RATE OF RISE TYPE) SYSTEM CONNECTED SMOKE DETECTOR FOR FIREMAN'S RECALL FIRE SMOKE DAMPER SMOKE DOOR HOLDER TAMPER SWITCH FLOW SWITCH L FLASHING LIGHT/HORN SIGNAL STATION 80" FS FACP FAA FLASHING LIGHT SPEAKER SIGNAL STATION CONTROL PANEL REMOTE ANNUNCIATOR 80" DC DOOR CONTACTOR RGA CR EDS MDL RMD RPB PE AV TV EPO KP IC A ARA ABOVE FINISHED FLOOR ABOVE FINISHED GRADE MOUNT ABOVE COUNTER ABOVE CEILING CEILING ELECTRIC WATER COOLER EMERGENCY EXISTING ROOM WIZARD FURNISHED BY OTHERS, INSTALLED BY ELECTRICAL CONTRACTOR GROUND RELOCATED UNLESS OTHERWISE NOTED WATER HEATER WEATHER PROOF, NEMA 3R SYMBOLS GENERAL NOTES: FIRE ALARM SYSTEM A. ALL MOUNTING HEIGHTS GIVEN IN THE LEGEND, SCHEDULES, PLANS, AND DRAWING NOTES ARE TO THE CENTERLINE OF THE DEVICE, UNLESS OTHERWISE NOTED. B. INSTALL ALL SWITCHES AT A CENTERLINE HEIGHT OF A.F.F. UNLESS OTHERWISE NOTED. WHERE SWITCHES OR RECEPTACLES ARE MOUNTED ABOVE CASEWORK OR MILLWORK, LOCATE AT A HEIGHT OF 3'-8" MAX. ABOVE FINISH FLOOR OR 3" ABOVE BACKSPLASH TO CENTERLINE. C. SEE ARCHITECTURAL MOUNTING HEIGHTS. D. ADDITIONAL SYMBOLS MAY BE SHOWN OR DENOTED ON OTHER SHEETS. E. ALL SYMBOLS, NOTES, AND ABBREVIATIONS SHOWN ON THE LEGEND ARE NOT NECESSARILY USED IN THIS SET OF CONTRACT DOCUMENTS. F. NUMERICAL SUBSCRIPT ADJACENT TO DEVICE FIXTURE, EQUIPMENT OR JUNCTION BOX SYMBOL ON THE DRAWINGS DENOTES THE PANELBOARD CIRCUIT NUMBER TO WHICH DEVICE, FIXTURE, EQUIPMENT OR WIRING IN JUNCTION BOX IS CONNECTED. MOUNTING HT TO CENTERLINE UNO FLASHING LIGHT 80" REMOTE GENERATOR ANNUNCIATOR CARD READER ELECTRIC DOOR STRIKE MAGNETIC DOOR STRIKE REQUEST TO EXIT MOTION DETECTOR REQUEST TO EXIT PUSH DETECTOR DATA DUPLEX ABOVE COUNTER DATA DUPLEX WIRELESS ACCESS POINT TELEPHONE OUTLET TELEPHONE DATA OUTLET PHOTOCELL AUDIO/VISUAL CONNECTION TV EMERGENCY POWER OFF SWITCH KEYPAD AREA OF REFUGE INTERCOM AREA OF REFUGE HEADEND Lighting Fixture Schedule MISCELLANEOUS ABBREVIATIONS Type Manufacturer Model Lamp Description 1 LITHONIA DMW2-L24-4000LM-AFL-WD-120-GZ1-35K-80CRI 40W LED STRIP FIXTURE FASTENED TO STRUCTURE 80" CEILING CEILING 6'-0" CEILING M ELECTRICAL LEGEND SYMBOL DESCRIPTION EBP "5" 3 SV PS R T J PB PP S S 2 3R 3R S 3 S 4 S D S M S OC S 3D S T S TWP S TP S LV ELC S WP J J J HH MH PP J PDM OC E TV E GFI AV AV AV BPI AFM SR USB IG IG IG WP CONDUIT CONCEALED IN WALL OR CEILING. CONDUIT CONCEALED IN FLOOR CONDUIT EXPOSED ON WALL OR CEILING. HOMERUN CONDUIT CONDUIT TURNING UP CONDUIT TURNING DOWN SURFACE MOUNTED LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT SURFACE MOUNTED FIXTURE ON EMERGENCY BRANCH CIRCUIT SURFACE MOUNTED FIXTURE ON CRITICAL BRANCH CIRCUIT RECESSED LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT RECESSED LIGHT FIXTURE ON EMERGENCY BRANCH CIRCUIT SURFACE MOUNTED WALL LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT SURFACE MOUNTED WALL LIGHT FIXTURE ON EMERGENCY BRANCH CIRCUIT SURFACE MOUNTED WALL LIGHT FIXTURE ON CRITICAL BRANCH CIRCUIT RECESSED WALL LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT RECESSED MOUNTED WALL LIGHT FIXTURE ON EMERGENCY BRANCH CIRCUIT RECESSED MOUNTED WALL LIGHT FIXTURE ON CRITICAL BRANCH CIRCUIT SURFACE/SUSPENDED MOUNTED LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT SURFACE/SUSPENDED MOUNTED LIGHT FIXTURE ON EMERGENCY BRANCH CIRCUIT SURFACE/SUSPENDED MOUNTED LIGHT FIXTURE ON CRITICAL BRANCH CIRCUIT RECESSED LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT RECESSED LIGHT FIXTURE ON EMERGENCY BRANCH CIRCUIT RECESSED LIGHT FIXTURE ON CRITICAL BRANCH CIRCUIT EXIT LIGHT, CEILING MOUNTED EXIT LIGHT, WALL MOUNTED TWO HEAD BATTERY POWERED EMERGENCY EGRESS LIGHT REMOTE EMERGENCY BATTERY PACK LIGHTING FIXTURE TYPE DESIGNATION-SEE LIGHTING FIXTURE SCHEDULE AREA OR STREET LIGHT FIXTURE AREA OR STREET LIGHT FIXTURE DISCONNECT SWITCH, NON-FUSIBLE DISCONNECT SWITCH, FUSIBLE DISCONNECT SWITCH, NON-FUSIBLE RT DENOTES NEMA-3R DISCONNECT SWITCH, FUSIBLE RT DENOTES NEMA-3R MOTOR CONNECTION WITH APPROXIMATE HORSE-POWER SHOWN SOLENOID VALVE PRESSURE SWITCH RELAY TRANSFORMER JUNCTION BOX - NOT WALL MOUNTED JUNCTION BOX - WALL MOUNTED PUSH BUTTON HAND HOLE MAN HOLE ENCLOSED CIRCUIT BREAKER POWER POLE CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR SINGLE POLE SWITCH-(WHITE) TWO POLE SWITCH-(WHITE) THREE-WAY SWITCH-(WHITE) FOUR WAY SWITCH-(WHITE) SINGLE POLE DIMMER SWITCH WALL MOUNTED OCCUPANCY SENSOR SWITCH (WHITE) THREE-WAY DIMMER SWITCH THERMAL MOTOR SWITCH-(FBE) THERMAL MOTOR SWITCH, WEATHERPROOF-(FBE) THERMAL MOTOR SWITCH, WITH PILOT LIGHT (FBE) LOW VOLTAGE SWITCH POWER PACK EMERGENCY LIGHTING CONTROLLER - FUNCTIONAL DEVICES ESRB SINGLE POLE SWITCH, WEATHERPROOF 20A 120V. DUPLEX RECEPTACLE 20A 120V. DUPLEX RECEPTACLE ABOVE COUNTER 20A 120V. DUPLEX RECEPTACLE ABOVE COUNTER ON EMERGENCY BRANCH CIRCUIT (RED) 20A 120V. DUPLEX RECEPTACLE FOR TV POWER 6" TO CENTERLINE BELOW FINISH CEILING 20A 120V. QUADRAPLEX RECEPTACLE SINGLE RECEPTACLE, AMPERAGE, VOLTAGE, NEMA CONFIGURATION AS REQUIRED BY EQUIP. SUPPLIER OR AS NOTED 20A 120V. QUADRAPLEX RECEPTACLE ABOVE COUNTER 20A 120V. QUADRAPLEX RECEPTACLE ABOVE COUNTER ON EMERGENCY BRANCH CIRCUIT 20A GROUND FAULT TYPE RECEPTACLE 20A GROUND FAULT RECEPTACLE WEATHERPROOF TWO GANG WITH ONE DUPLEX RECEPTACLE AND ONE DATA OUTLET TWO GANG WITH ONE QUAD 20A RECEPTACLE AND ONE DATA OUTLET TWO GANG WITH ONE HARD CONNECTION 20A RECEPTACLE, & ONE DATA OUTLET THREE GANG WITH TWO DUPLEX 20A RECEPTACLES, & ONE TELEPHONE OUTLET THREE GANG WITH ONE QUAD 20A RECEPTACLE AND ONE DATA OUTLET AND ONE AV CONNECTION THREE GANG WITH ONE DUPLEX 20A RECEPTACLE AND ONE DATA OUTLET AND ONE AV CONNECTION THREE GANG WITH ONE HARDWARE CONNECTION AND ONE DATA OUTLET AND ONE AV CONNECTION WALL MOUNTED FURNITURE BASE POWER FEED POWER DISTRIBUTION MODULE ACCESS FLOOR MODULE 20A DUPLEX RECEPTACLE AND SINGLE POLE SWITCH UNDER COMMON PLATE 20A 120V. DUPLEX USB TYPE 20A DUPLEX RECEPTACLE, ISOLATED GROUNDING, 20A DUPLEX RECEPTACLE, ISOLATED GROUNDING, INSTALL ABOVE COUNTER 20A QUADRAPLEX RECEPTACLE, ISOLATED GROUNDING 20A WEATHERPROOF DUPLEX RECEPTACLE 120V DUPLEX RECEPTACLE, CEILING MOUNTED WITH (1) SINGLE RECEPTACLE - AMPERAGE, VOLTAGE, NEMA CONFIGURATION AS REQUIRED BY EQUIP. SUPPLIER OR AS NOTED WITH (1) DUPLEX RECEPTACLE WITH (1) QUADRUPLEX RECEPTACLE WIREMOLD #3000 WITH HUBBELL 5352 DUPLEX 20A RECEPTACLES 24" ON CENTER PLUGMOLD #2000 WITH 20A DUPLEX RECEPTACLES 24" ON CENTER PUSHPAD FOR AUTOMATIC DOORS (F.B.O.) MOUNTING HEIGHT TO CENTERLINE UON AS NOTED CEILING NO. Date Issues/Revisions STAMP PROJECT NAME PRESERVATION PARK AMPHITHEATER Stage Thompson's Station, Tennessee PROJECT NO.: 171868 DRAWN BY: CHECKED BY: DRAWING TITLE ELECTRICAL LEGEND AND SCHEDULES DATE: April Dec. 2, 01, 2018 2017 SCALE: DRAWING NUMBER E0.01

I.C. Thomasson Associates, Inc. CONSULTING ENGINEERS 2950 KRAFT DRIVE, SUITE 500 NASHVILLE, TN. 37204 PHONE (615) 346-3400 FAX (615) 346-3550 www.icthomasson.com ICT PROJECT # 170647 HODGSON DOUGLAS landscape architecture planning. urban design 120 29th Ave. South, Nashville, Tennessee 37221 t. 615.327.4447 f. 615.321.3004 www.hodgsondouglas.com Branch Panel: P1 Location: Exterior Volts: 120/240 Single A.I.C. Rating: 10000 Supply From: Utility Transformer Phases: 1 Mains Type: MCB Mounting: Surface Wires: 3 Mains Rating: 60 A Enclosure: Type 3R MCB Rating: 60 A Notes: UTILITY TRANSFORMER N Demand A B Demand CKT Circuit Description Code TRIP P P TRIP Code Circuit Description CKT 1 Lighting Lighting 20 A 1 160 180 1 20 A Recepta... Receptacle 2 3 Receptacle Recepta... 20 A 1 180 320 1 20 A Lighting Lighting 4 5 Receptacle Recepta... 20 A 1 180 180 1 20 A Recepta... Receptacle 6 7 Spare -- 20 A 1 0 0 1 20 A -- Spare 8 9 Spare -- 20 A 1 0 0 1 20 A -- Spare 10 11 Spare -- 20 A 1 0 0 1 20 A -- Spare 12 13 Spare -- 20 A 1 0 0 1 20 A -- Spare 14 15 Spare -- 20 A 1 0 0 1 20 A -- Spare 16 17 Spare -- 20 A 1 0 0 1 20 A -- Spare 18 19 Spare -- 20 A 1 0 0 1 20 A -- Spare 20 21 Spare -- 20 A 1 0 0 1 20 A -- Spare 22 23 Spare -- 20 A 1 0 0 1 20 A -- Spare 24 25 Spare -- 20 A 1 0 0 1 20 A -- Spare 26 27 Spare -- 20 A 1 0 0 1 20 A -- Spare 28 29 Spare -- 20 A 1 0 0 1 20 A -- Spare 30 Total Load: 694 VA 494 VA Total Amps: 6 A 4 A Legend: GROUNDED SERVICE CONDUCTOR (SIZE PER NEC TABLE 250.66 AND 12-1/2% RULE) GROUNDING ELECTRODE CONDUCTOR (SIZE PER NEC TABLE 250.66) N G SERVICE ENTRANCE BREAKER MAIN BONDING JUMPER (SIZE PER NEC TABLE 250.66 AND 12-1/2% RULE) Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Lighting 480 VA 100.00% 480 VA Receptacle 720 VA 100.00% 720 VA Total Conn. Load: 1186 VA Total Est. Demand: 1186 VA Total Conn. Current: 5 A Total Est. Demand Current: 5 A Notes: SERVICE ENTRANCE RATED Branch Panel: P2 Location: Exterior Volts: 120/240 Single A.I.C. Rating: 10000 Supply From: Utility Transformer Phases: 1 Mains Type: MCB Mounting: Surface Wires: 3 Mains Rating: 60 A Enclosure: Type 3R MCB Rating: 60 A SERVICE ENTRANCE GROUNDING DETAIL No Scale WATER PIPE, BUILDING STEEL & GROUND LOOP TO LOAD EQUIPMENT GROUNDING CONDUCTOR (SIZE PER NEC TABLE 250.122) 2 NO. Date Issues/Revisions Notes: Demand A B Demand CKT Circuit Description Code TRIP P P TRIP Code Circuit Description CKT 1 Lighting Lighting 20 A 1 480 180 1 20 A Recepta... Receptacle 2 3 Receptacle Recepta... 20 A 1 180 160 1 20 A Lighting Lighting 4 5 Receptacle Recepta... 20 A 1 180 180 1 20 A Recepta... Receptacle 6 7 Receptacle Recepta... 20 A 1 180 180 1 20 A Recepta... Receptacle 8 9 Spare -- 20 A 1 0 0 1 20 A -- Spare 10 11 Spare -- 20 A 1 0 0 1 20 A -- Spare 12 13 Spare -- 20 A 1 0 0 1 20 A -- Spare 14 15 Spare -- 20 A 1 0 0 1 20 A -- Spare 16 17 Spare -- 20 A 1 0 0 1 20 A -- Spare 18 19 Spare -- 20 A 1 0 0 1 20 A -- Spare 20 21 Spare -- 20 A 1 0 0 1 20 A -- Spare 22 23 Spare -- 20 A 1 0 0 1 20 A -- Spare 24 25 Spare -- 20 A 1 0 0 1 20 A -- Spare 26 27 Spare -- 20 A 1 0 0 1 20 A -- Spare 28 29 Spare -- 20 A 1 0 0 1 20 A -- Spare 30 Total Load: 1007 VA 694 VA Total Amps: 8 A 6 A Legend: Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Lighting 640 VA 100.00% 640 VA Receptacle 1080 VA 100.00% 1080 VA Total Conn. Load: 1700 VA Total Est. Demand: 1700 VA Total Conn. Current: 7 A Total Est. Demand Current: 7 A UTILITY TRANSFORMER P1 60A 120/240 1 PHASE NEMA 3R UTILITY TRANSFORMER P2 60A 120/240 1 PHASE NEMA 3R STAMP PROJECT NAME PRESERVATION PARK AMPHITHEATER Thompson's Station, Tennessee Notes: SERVICE ENTRANCE RATED 3#4,#8GND,1"C. 3#4,#8GND,1"C. Stage ELECTRICAL RISER DIAGRAM N.T.S. PROJECT NO.: 171868 DRAWN BY: CHECKED BY: DRAWING TITLE ELECTRICAL DETAILS DATE: April Dec. 2, 01, 2018 2017 SCALE: DRAWING NUMBER E1.01

36'' I.C. Thomasson Associates, Inc. CONSULTING ENGINEERS 2950 KRAFT DRIVE, SUITE 500 NASHVILLE, TN. 37204 PHONE (615) 346-3400 FAX (615) 346-3550 www.icthomasson.com ICT PROJECT # 170647 HODGSON DOUGLAS landscape architecture planning. urban design 120 29th Ave. South, Nashville, Tennessee 37221 t. 615.327.4447 f. 615.321.3004 www.hodgsondouglas.com 12'' 28'' 20'' 50'' OAK 54'' OAK SHED TRANFORMER BY MTEMC AND THOMPSON STATION NEW 60A 240V 2P, 3W, 3R SERVICE ENTRANCE PANELBOARD 'P2' T (1) 2" CONDUIT BY MTEMC AND THOMPSON'S STATION. GENERAL NOTES: A. THE EXISTING UTILITY LOCATIONS ARE SHOWN FOR GENERAL INFORMATION ONLY AND ARE NOT GUARANTEED TO BE EITHER ACCURATE OR ALL INCLUSIVE. PRIOR TO EXCAVATION IN ANY AREA, OBTAIN THE AID OF ALL UTILITY OWNERS TO IDENTIFY AND LOCATE THEIR RESPECTIVE FACILITIES. ANY UTILITY DAMAGE CAUSED BY THE CONSTRUCTION ACTIVITIES SHALL BE REPAIRED OR REPLACED AT NO EXPENSE TO THE OWNER. B. EXISTING UTILITIES, WHICH ARE NOT SHOWN, THAT ARE DISCOVERED DURING EXCAVATION SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVES FOR PROPER COORDINATION. REMOVE, REWORK AND/OR REROUTE THE EXISTING UTILITIES, AS DIRECTED BY THE OWNER'S REPRESENTATIVES. C. FULLY COORDINATE ALL REQUIREMENTS WITH MIDDLE TENNESSEE ELECTRIC MEMBERSHIP CORPORATION (MTEMC). NO. Date Issues/Revisions D. REFERENCE MTEMC GUIDELINES FOR ADDITIONAL DETAILS. TRANFORMER BY MTEMC AND THOMPSON STATION NEW 60A 240V 2P, 3W, 3R SERVICE ENTRANCE PANELBOARD 'P1' T (1) 2" CONDUIT BY MTEMC AND THOMPSON'S STATION. STAMP (1) 2" CONDUIT BY MTEMC AND THOMPSON'S STATION. TRANSFORMER BY MTEMC AND THOMPSON'S STATION T (1) 2" CONDUIT BY MTEMC AND THOMPSON'S STATION. PROJECT NAME PRESERVATION PARK AMPHITHEATER Thompson's Station, Tennessee Stage 100% CHECKSET PROJECT NO.: 171868 DRAWN BY: CHECKED BY: DRAWING TITLE ELECTRICAL - SITE PLAN 1 SITE PLAN ES.01 1" = 50'-0" DATE: April Dec. 2, 22, 01, 2018 2017 SCALE: DRAWING NUMBER ES.01

I.C. Thomasson Associates, Inc. CONSULTING ENGINEERS 2950 KRAFT DRIVE, SUITE 500 NASHVILLE, TN. 37204 PHONE (615) 346-3400 FAX (615) 346-3550 www.icthomasson.com ICT PROJECT # 170647 HODGSON DOUGLAS landscape architecture planning. urban design 120 29th Ave. South, Nashville, Tennessee 37221 t. 615.327.4447 f. 615.321.3004 www.hodgsondouglas.com P2-7 P1-3 P1-2 P2-8 P1-6 WP P1 P1-1 P1-4 WP P1-5 P2-3 WP P2-1 P2 P2-2 NO. Date Issues/Revisions P2-6 WP P2-5 STAMP P2-4 2 ENLARGED SITE PLAN A ES.02 3/64" = 1'-0" 1 ENLARGED SITE PLAN B ES.02 3/64" = 1'-0" PROJECT NAME PRESERVATION PARK AMPHITHEATER Thompson's Station, Tennessee Stage PROJECT NO.: 171868 DRAWN BY: CHECKED BY: DRAWING TITLE ELECTRICAL - ENGLARGED PLANS DATE: April Dec. 2, 01, 2018 2017 SCALE: DRAWING NUMBER ES.02