I.C. Thomasson Associates, Inc. CONSULTING ENGINEERS 2950 KRAFT DRIVE, SUITE 500 NASHVILLE, TN. 37204 PHONE (615) 346-3400 FAX (615) 346-3550 www.icthomasson.com ICT PROJECT # 170647 HODGSON DOUGLAS landscape architecture planning. urban design 120 29th Ave. South, Nashville, Tennessee 37221 t. 615.327.4447 f. 615.321.3004 www.hodgsondouglas.com SYMBOL L L F SD DSD HD SD E FSD DH TS FS AFF AFG ABV ABC CLG EWC EM EX RW FBO GND R UON WH WP DESCRIPTION CHIME/FLASHING LIGHT COMBINATION MANUAL PULL STATION SMOKE DETECTOR DUCT-SMOKE DETECTOR (DAMPER) OR (EXHAUST) AUTOMATIC HEAT DETECTOR (RATE OF RISE TYPE) SYSTEM CONNECTED SMOKE DETECTOR FOR FIREMAN'S RECALL FIRE SMOKE DAMPER SMOKE DOOR HOLDER TAMPER SWITCH FLOW SWITCH L FLASHING LIGHT/HORN SIGNAL STATION 80" FS FACP FAA FLASHING LIGHT SPEAKER SIGNAL STATION CONTROL PANEL REMOTE ANNUNCIATOR 80" DC DOOR CONTACTOR RGA CR EDS MDL RMD RPB PE AV TV EPO KP IC A ARA ABOVE FINISHED FLOOR ABOVE FINISHED GRADE MOUNT ABOVE COUNTER ABOVE CEILING CEILING ELECTRIC WATER COOLER EMERGENCY EXISTING ROOM WIZARD FURNISHED BY OTHERS, INSTALLED BY ELECTRICAL CONTRACTOR GROUND RELOCATED UNLESS OTHERWISE NOTED WATER HEATER WEATHER PROOF, NEMA 3R SYMBOLS GENERAL NOTES: FIRE ALARM SYSTEM A. ALL MOUNTING HEIGHTS GIVEN IN THE LEGEND, SCHEDULES, PLANS, AND DRAWING NOTES ARE TO THE CENTERLINE OF THE DEVICE, UNLESS OTHERWISE NOTED. B. INSTALL ALL SWITCHES AT A CENTERLINE HEIGHT OF A.F.F. UNLESS OTHERWISE NOTED. WHERE SWITCHES OR RECEPTACLES ARE MOUNTED ABOVE CASEWORK OR MILLWORK, LOCATE AT A HEIGHT OF 3'-8" MAX. ABOVE FINISH FLOOR OR 3" ABOVE BACKSPLASH TO CENTERLINE. C. SEE ARCHITECTURAL MOUNTING HEIGHTS. D. ADDITIONAL SYMBOLS MAY BE SHOWN OR DENOTED ON OTHER SHEETS. E. ALL SYMBOLS, NOTES, AND ABBREVIATIONS SHOWN ON THE LEGEND ARE NOT NECESSARILY USED IN THIS SET OF CONTRACT DOCUMENTS. F. NUMERICAL SUBSCRIPT ADJACENT TO DEVICE FIXTURE, EQUIPMENT OR JUNCTION BOX SYMBOL ON THE DRAWINGS DENOTES THE PANELBOARD CIRCUIT NUMBER TO WHICH DEVICE, FIXTURE, EQUIPMENT OR WIRING IN JUNCTION BOX IS CONNECTED. MOUNTING HT TO CENTERLINE UNO FLASHING LIGHT 80" REMOTE GENERATOR ANNUNCIATOR CARD READER ELECTRIC DOOR STRIKE MAGNETIC DOOR STRIKE REQUEST TO EXIT MOTION DETECTOR REQUEST TO EXIT PUSH DETECTOR DATA DUPLEX ABOVE COUNTER DATA DUPLEX WIRELESS ACCESS POINT TELEPHONE OUTLET TELEPHONE DATA OUTLET PHOTOCELL AUDIO/VISUAL CONNECTION TV EMERGENCY POWER OFF SWITCH KEYPAD AREA OF REFUGE INTERCOM AREA OF REFUGE HEADEND Lighting Fixture Schedule MISCELLANEOUS ABBREVIATIONS Type Manufacturer Model Lamp Description 1 LITHONIA DMW2-L24-4000LM-AFL-WD-120-GZ1-35K-80CRI 40W LED STRIP FIXTURE FASTENED TO STRUCTURE 80" CEILING CEILING 6'-0" CEILING M ELECTRICAL LEGEND SYMBOL DESCRIPTION EBP "5" 3 SV PS R T J PB PP S S 2 3R 3R S 3 S 4 S D S M S OC S 3D S T S TWP S TP S LV ELC S WP J J J HH MH PP J PDM OC E TV E GFI AV AV AV BPI AFM SR USB IG IG IG WP CONDUIT CONCEALED IN WALL OR CEILING. CONDUIT CONCEALED IN FLOOR CONDUIT EXPOSED ON WALL OR CEILING. HOMERUN CONDUIT CONDUIT TURNING UP CONDUIT TURNING DOWN SURFACE MOUNTED LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT SURFACE MOUNTED FIXTURE ON EMERGENCY BRANCH CIRCUIT SURFACE MOUNTED FIXTURE ON CRITICAL BRANCH CIRCUIT RECESSED LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT RECESSED LIGHT FIXTURE ON EMERGENCY BRANCH CIRCUIT SURFACE MOUNTED WALL LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT SURFACE MOUNTED WALL LIGHT FIXTURE ON EMERGENCY BRANCH CIRCUIT SURFACE MOUNTED WALL LIGHT FIXTURE ON CRITICAL BRANCH CIRCUIT RECESSED WALL LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT RECESSED MOUNTED WALL LIGHT FIXTURE ON EMERGENCY BRANCH CIRCUIT RECESSED MOUNTED WALL LIGHT FIXTURE ON CRITICAL BRANCH CIRCUIT SURFACE/SUSPENDED MOUNTED LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT SURFACE/SUSPENDED MOUNTED LIGHT FIXTURE ON EMERGENCY BRANCH CIRCUIT SURFACE/SUSPENDED MOUNTED LIGHT FIXTURE ON CRITICAL BRANCH CIRCUIT RECESSED LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT RECESSED LIGHT FIXTURE ON EMERGENCY BRANCH CIRCUIT RECESSED LIGHT FIXTURE ON CRITICAL BRANCH CIRCUIT EXIT LIGHT, CEILING MOUNTED EXIT LIGHT, WALL MOUNTED TWO HEAD BATTERY POWERED EMERGENCY EGRESS LIGHT REMOTE EMERGENCY BATTERY PACK LIGHTING FIXTURE TYPE DESIGNATION-SEE LIGHTING FIXTURE SCHEDULE AREA OR STREET LIGHT FIXTURE AREA OR STREET LIGHT FIXTURE DISCONNECT SWITCH, NON-FUSIBLE DISCONNECT SWITCH, FUSIBLE DISCONNECT SWITCH, NON-FUSIBLE RT DENOTES NEMA-3R DISCONNECT SWITCH, FUSIBLE RT DENOTES NEMA-3R MOTOR CONNECTION WITH APPROXIMATE HORSE-POWER SHOWN SOLENOID VALVE PRESSURE SWITCH RELAY TRANSFORMER JUNCTION BOX - NOT WALL MOUNTED JUNCTION BOX - WALL MOUNTED PUSH BUTTON HAND HOLE MAN HOLE ENCLOSED CIRCUIT BREAKER POWER POLE CEILING MOUNTED DUAL TECHNOLOGY OCCUPANCY SENSOR SINGLE POLE SWITCH-(WHITE) TWO POLE SWITCH-(WHITE) THREE-WAY SWITCH-(WHITE) FOUR WAY SWITCH-(WHITE) SINGLE POLE DIMMER SWITCH WALL MOUNTED OCCUPANCY SENSOR SWITCH (WHITE) THREE-WAY DIMMER SWITCH THERMAL MOTOR SWITCH-(FBE) THERMAL MOTOR SWITCH, WEATHERPROOF-(FBE) THERMAL MOTOR SWITCH, WITH PILOT LIGHT (FBE) LOW VOLTAGE SWITCH POWER PACK EMERGENCY LIGHTING CONTROLLER - FUNCTIONAL DEVICES ESRB SINGLE POLE SWITCH, WEATHERPROOF 20A 120V. DUPLEX RECEPTACLE 20A 120V. DUPLEX RECEPTACLE ABOVE COUNTER 20A 120V. DUPLEX RECEPTACLE ABOVE COUNTER ON EMERGENCY BRANCH CIRCUIT (RED) 20A 120V. DUPLEX RECEPTACLE FOR TV POWER 6" TO CENTERLINE BELOW FINISH CEILING 20A 120V. QUADRAPLEX RECEPTACLE SINGLE RECEPTACLE, AMPERAGE, VOLTAGE, NEMA CONFIGURATION AS REQUIRED BY EQUIP. SUPPLIER OR AS NOTED 20A 120V. QUADRAPLEX RECEPTACLE ABOVE COUNTER 20A 120V. QUADRAPLEX RECEPTACLE ABOVE COUNTER ON EMERGENCY BRANCH CIRCUIT 20A GROUND FAULT TYPE RECEPTACLE 20A GROUND FAULT RECEPTACLE WEATHERPROOF TWO GANG WITH ONE DUPLEX RECEPTACLE AND ONE DATA OUTLET TWO GANG WITH ONE QUAD 20A RECEPTACLE AND ONE DATA OUTLET TWO GANG WITH ONE HARD CONNECTION 20A RECEPTACLE, & ONE DATA OUTLET THREE GANG WITH TWO DUPLEX 20A RECEPTACLES, & ONE TELEPHONE OUTLET THREE GANG WITH ONE QUAD 20A RECEPTACLE AND ONE DATA OUTLET AND ONE AV CONNECTION THREE GANG WITH ONE DUPLEX 20A RECEPTACLE AND ONE DATA OUTLET AND ONE AV CONNECTION THREE GANG WITH ONE HARDWARE CONNECTION AND ONE DATA OUTLET AND ONE AV CONNECTION WALL MOUNTED FURNITURE BASE POWER FEED POWER DISTRIBUTION MODULE ACCESS FLOOR MODULE 20A DUPLEX RECEPTACLE AND SINGLE POLE SWITCH UNDER COMMON PLATE 20A 120V. DUPLEX USB TYPE 20A DUPLEX RECEPTACLE, ISOLATED GROUNDING, 20A DUPLEX RECEPTACLE, ISOLATED GROUNDING, INSTALL ABOVE COUNTER 20A QUADRAPLEX RECEPTACLE, ISOLATED GROUNDING 20A WEATHERPROOF DUPLEX RECEPTACLE 120V DUPLEX RECEPTACLE, CEILING MOUNTED WITH (1) SINGLE RECEPTACLE - AMPERAGE, VOLTAGE, NEMA CONFIGURATION AS REQUIRED BY EQUIP. SUPPLIER OR AS NOTED WITH (1) DUPLEX RECEPTACLE WITH (1) QUADRUPLEX RECEPTACLE WIREMOLD #3000 WITH HUBBELL 5352 DUPLEX 20A RECEPTACLES 24" ON CENTER PLUGMOLD #2000 WITH 20A DUPLEX RECEPTACLES 24" ON CENTER PUSHPAD FOR AUTOMATIC DOORS (F.B.O.) MOUNTING HEIGHT TO CENTERLINE UON AS NOTED CEILING NO. Date Issues/Revisions STAMP PROJECT NAME PRESERVATION PARK AMPHITHEATER Stage Thompson's Station, Tennessee PROJECT NO.: 171868 DRAWN BY: CHECKED BY: DRAWING TITLE ELECTRICAL LEGEND AND SCHEDULES DATE: April Dec. 2, 01, 2018 2017 SCALE: DRAWING NUMBER E0.01
I.C. Thomasson Associates, Inc. CONSULTING ENGINEERS 2950 KRAFT DRIVE, SUITE 500 NASHVILLE, TN. 37204 PHONE (615) 346-3400 FAX (615) 346-3550 www.icthomasson.com ICT PROJECT # 170647 HODGSON DOUGLAS landscape architecture planning. urban design 120 29th Ave. South, Nashville, Tennessee 37221 t. 615.327.4447 f. 615.321.3004 www.hodgsondouglas.com Branch Panel: P1 Location: Exterior Volts: 120/240 Single A.I.C. Rating: 10000 Supply From: Utility Transformer Phases: 1 Mains Type: MCB Mounting: Surface Wires: 3 Mains Rating: 60 A Enclosure: Type 3R MCB Rating: 60 A Notes: UTILITY TRANSFORMER N Demand A B Demand CKT Circuit Description Code TRIP P P TRIP Code Circuit Description CKT 1 Lighting Lighting 20 A 1 160 180 1 20 A Recepta... Receptacle 2 3 Receptacle Recepta... 20 A 1 180 320 1 20 A Lighting Lighting 4 5 Receptacle Recepta... 20 A 1 180 180 1 20 A Recepta... Receptacle 6 7 Spare -- 20 A 1 0 0 1 20 A -- Spare 8 9 Spare -- 20 A 1 0 0 1 20 A -- Spare 10 11 Spare -- 20 A 1 0 0 1 20 A -- Spare 12 13 Spare -- 20 A 1 0 0 1 20 A -- Spare 14 15 Spare -- 20 A 1 0 0 1 20 A -- Spare 16 17 Spare -- 20 A 1 0 0 1 20 A -- Spare 18 19 Spare -- 20 A 1 0 0 1 20 A -- Spare 20 21 Spare -- 20 A 1 0 0 1 20 A -- Spare 22 23 Spare -- 20 A 1 0 0 1 20 A -- Spare 24 25 Spare -- 20 A 1 0 0 1 20 A -- Spare 26 27 Spare -- 20 A 1 0 0 1 20 A -- Spare 28 29 Spare -- 20 A 1 0 0 1 20 A -- Spare 30 Total Load: 694 VA 494 VA Total Amps: 6 A 4 A Legend: GROUNDED SERVICE CONDUCTOR (SIZE PER NEC TABLE 250.66 AND 12-1/2% RULE) GROUNDING ELECTRODE CONDUCTOR (SIZE PER NEC TABLE 250.66) N G SERVICE ENTRANCE BREAKER MAIN BONDING JUMPER (SIZE PER NEC TABLE 250.66 AND 12-1/2% RULE) Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Lighting 480 VA 100.00% 480 VA Receptacle 720 VA 100.00% 720 VA Total Conn. Load: 1186 VA Total Est. Demand: 1186 VA Total Conn. Current: 5 A Total Est. Demand Current: 5 A Notes: SERVICE ENTRANCE RATED Branch Panel: P2 Location: Exterior Volts: 120/240 Single A.I.C. Rating: 10000 Supply From: Utility Transformer Phases: 1 Mains Type: MCB Mounting: Surface Wires: 3 Mains Rating: 60 A Enclosure: Type 3R MCB Rating: 60 A SERVICE ENTRANCE GROUNDING DETAIL No Scale WATER PIPE, BUILDING STEEL & GROUND LOOP TO LOAD EQUIPMENT GROUNDING CONDUCTOR (SIZE PER NEC TABLE 250.122) 2 NO. Date Issues/Revisions Notes: Demand A B Demand CKT Circuit Description Code TRIP P P TRIP Code Circuit Description CKT 1 Lighting Lighting 20 A 1 480 180 1 20 A Recepta... Receptacle 2 3 Receptacle Recepta... 20 A 1 180 160 1 20 A Lighting Lighting 4 5 Receptacle Recepta... 20 A 1 180 180 1 20 A Recepta... Receptacle 6 7 Receptacle Recepta... 20 A 1 180 180 1 20 A Recepta... Receptacle 8 9 Spare -- 20 A 1 0 0 1 20 A -- Spare 10 11 Spare -- 20 A 1 0 0 1 20 A -- Spare 12 13 Spare -- 20 A 1 0 0 1 20 A -- Spare 14 15 Spare -- 20 A 1 0 0 1 20 A -- Spare 16 17 Spare -- 20 A 1 0 0 1 20 A -- Spare 18 19 Spare -- 20 A 1 0 0 1 20 A -- Spare 20 21 Spare -- 20 A 1 0 0 1 20 A -- Spare 22 23 Spare -- 20 A 1 0 0 1 20 A -- Spare 24 25 Spare -- 20 A 1 0 0 1 20 A -- Spare 26 27 Spare -- 20 A 1 0 0 1 20 A -- Spare 28 29 Spare -- 20 A 1 0 0 1 20 A -- Spare 30 Total Load: 1007 VA 694 VA Total Amps: 8 A 6 A Legend: Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Lighting 640 VA 100.00% 640 VA Receptacle 1080 VA 100.00% 1080 VA Total Conn. Load: 1700 VA Total Est. Demand: 1700 VA Total Conn. Current: 7 A Total Est. Demand Current: 7 A UTILITY TRANSFORMER P1 60A 120/240 1 PHASE NEMA 3R UTILITY TRANSFORMER P2 60A 120/240 1 PHASE NEMA 3R STAMP PROJECT NAME PRESERVATION PARK AMPHITHEATER Thompson's Station, Tennessee Notes: SERVICE ENTRANCE RATED 3#4,#8GND,1"C. 3#4,#8GND,1"C. Stage ELECTRICAL RISER DIAGRAM N.T.S. PROJECT NO.: 171868 DRAWN BY: CHECKED BY: DRAWING TITLE ELECTRICAL DETAILS DATE: April Dec. 2, 01, 2018 2017 SCALE: DRAWING NUMBER E1.01
36'' I.C. Thomasson Associates, Inc. CONSULTING ENGINEERS 2950 KRAFT DRIVE, SUITE 500 NASHVILLE, TN. 37204 PHONE (615) 346-3400 FAX (615) 346-3550 www.icthomasson.com ICT PROJECT # 170647 HODGSON DOUGLAS landscape architecture planning. urban design 120 29th Ave. South, Nashville, Tennessee 37221 t. 615.327.4447 f. 615.321.3004 www.hodgsondouglas.com 12'' 28'' 20'' 50'' OAK 54'' OAK SHED TRANFORMER BY MTEMC AND THOMPSON STATION NEW 60A 240V 2P, 3W, 3R SERVICE ENTRANCE PANELBOARD 'P2' T (1) 2" CONDUIT BY MTEMC AND THOMPSON'S STATION. GENERAL NOTES: A. THE EXISTING UTILITY LOCATIONS ARE SHOWN FOR GENERAL INFORMATION ONLY AND ARE NOT GUARANTEED TO BE EITHER ACCURATE OR ALL INCLUSIVE. PRIOR TO EXCAVATION IN ANY AREA, OBTAIN THE AID OF ALL UTILITY OWNERS TO IDENTIFY AND LOCATE THEIR RESPECTIVE FACILITIES. ANY UTILITY DAMAGE CAUSED BY THE CONSTRUCTION ACTIVITIES SHALL BE REPAIRED OR REPLACED AT NO EXPENSE TO THE OWNER. B. EXISTING UTILITIES, WHICH ARE NOT SHOWN, THAT ARE DISCOVERED DURING EXCAVATION SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVES FOR PROPER COORDINATION. REMOVE, REWORK AND/OR REROUTE THE EXISTING UTILITIES, AS DIRECTED BY THE OWNER'S REPRESENTATIVES. C. FULLY COORDINATE ALL REQUIREMENTS WITH MIDDLE TENNESSEE ELECTRIC MEMBERSHIP CORPORATION (MTEMC). NO. Date Issues/Revisions D. REFERENCE MTEMC GUIDELINES FOR ADDITIONAL DETAILS. TRANFORMER BY MTEMC AND THOMPSON STATION NEW 60A 240V 2P, 3W, 3R SERVICE ENTRANCE PANELBOARD 'P1' T (1) 2" CONDUIT BY MTEMC AND THOMPSON'S STATION. STAMP (1) 2" CONDUIT BY MTEMC AND THOMPSON'S STATION. TRANSFORMER BY MTEMC AND THOMPSON'S STATION T (1) 2" CONDUIT BY MTEMC AND THOMPSON'S STATION. PROJECT NAME PRESERVATION PARK AMPHITHEATER Thompson's Station, Tennessee Stage 100% CHECKSET PROJECT NO.: 171868 DRAWN BY: CHECKED BY: DRAWING TITLE ELECTRICAL - SITE PLAN 1 SITE PLAN ES.01 1" = 50'-0" DATE: April Dec. 2, 22, 01, 2018 2017 SCALE: DRAWING NUMBER ES.01
I.C. Thomasson Associates, Inc. CONSULTING ENGINEERS 2950 KRAFT DRIVE, SUITE 500 NASHVILLE, TN. 37204 PHONE (615) 346-3400 FAX (615) 346-3550 www.icthomasson.com ICT PROJECT # 170647 HODGSON DOUGLAS landscape architecture planning. urban design 120 29th Ave. South, Nashville, Tennessee 37221 t. 615.327.4447 f. 615.321.3004 www.hodgsondouglas.com P2-7 P1-3 P1-2 P2-8 P1-6 WP P1 P1-1 P1-4 WP P1-5 P2-3 WP P2-1 P2 P2-2 NO. Date Issues/Revisions P2-6 WP P2-5 STAMP P2-4 2 ENLARGED SITE PLAN A ES.02 3/64" = 1'-0" 1 ENLARGED SITE PLAN B ES.02 3/64" = 1'-0" PROJECT NAME PRESERVATION PARK AMPHITHEATER Thompson's Station, Tennessee Stage PROJECT NO.: 171868 DRAWN BY: CHECKED BY: DRAWING TITLE ELECTRICAL - ENGLARGED PLANS DATE: April Dec. 2, 01, 2018 2017 SCALE: DRAWING NUMBER ES.02