UVC/T-AR UVC/T-M-AR UVT-S-AR

Similar documents
UVC/T-AR UVC/T-M-AR UVT-S-AR

UVC/T-M-AR stainless steel UV cabinet

PCR UV cabinets DNA/RNA

PCR UV Cabinets. PCR UV cabinet workstation UVT-S-AR PCR UV workstation

PCR UV cabinets DNA/RNA

UVT-B-AR. DNA/RNA UV-cleaner box. Operating Manual Certificate. Medical Biological Research & Technologies

1. About this edition of the operating manual

Scientific Equipment. Catalogue Precision temperature control, sample preparation and life sciences products for the world s laboratories

Operating Instructions Temperature Controller R38

SD-06AG Laboratory Scale Spray Dryer

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

The Growing Viability of UV LED for Wide Web Coating Applications. Tuesday, October 11, 2016

Installation, Operation & Maintenance Instructions Annealing Ovens TLD models

solo detectortesters single testing system. complete range of testing tools. detectortesters testing technology from No Climb

Biological Safety Cabinet

The Grant water baths are one of the most essential pieces of equipment in our kitchens. Ashley Palmer-Watts - Group Executive Chef, The Fat Duck

BORA SAFETY GOGGLE DESCRIPTION APPLICATIONS. PART CODES Product Code Article Number Description/Pk Size EAN/BAR Code

Ductless Fume Hoods, Chambers & Drying Cabinets

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

STANDARD SINGLE UV GERMICIDAL CLEANING DELUXE DUAL UV GERMICIDAL CLEANING PREMIUM DUAL UV GERMICIDAL CLEANING

Equipment specifications (D6)

Model KBF 240 Constant climate chambers with large temperature / humidity range

Dräger Polytron 7000 Fixed gas detector

LABORATORY CABINETS 103

Centrifuge/Vortex for PCR plates CVP-2

Thermo-Sealer. Manual Heat Sealer. User Manual

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

for Drinking Water Systems

Plant growth chambers

Version: 1603 UV Accelerated Weathering Testers Weice Testing Instrument Co., Limited

o Clear instruction for operation o Measurement and control of o Stationary sensor for o Programming capabilities of o Countdown timer selectable

HF Series R_RevB

ASSEMBLY & OPERATING INSTRUCTIONS

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Microtherm Heat Stress WBGT

Fitoclima Pharma. Stability and Photostability Chambers for the pharmaceutical industry

INSTRUCTION MANUAL AMS WATER MANAGEMENT SYSTEM (AMS-WMS 230V) INSTRUCTION MANUAL AMS WMS 230V Manual Issue 1 15/10/09 Page 1 of 15

Forma 1400 Series Class II, Type A2 Biological Safety Cabinet. Superior Ergonomics, Uncompromising Safety

Inline measuring of UV LED & conventional UV lamps

OLS26 Aqua Pro Orbital / Linear shaking bath. Offering ultimate flexibility and usability for all applications

DOUTHITT HEAVY DUTY PLATEMAKER

UVP, Inc. Ultra-Violet Products Ltd., Unit W 11th Street, Upland, CA Trinity Hall Farm Estate, Nuffield Road

UV Weather Resistance Test Chamber Technical Data

A Chiller is equipment to control temperature of customers heating sources. Application Examples

Effect of the Electro Breeze Air Filter on Airborne Particles in a Recirculating Air Duct

INCREASE YOUR LAB EFFICIENCY

Customized Drinking Water

OPERATING INSTRUCTIONS FOR LEEC AUTOMATIC CO2 INCUBATORS. MODELS GA2000 and GA2010 MODELS GA3000 and GA3010 With Infrared CO2 detectors CONTENTS

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

1020 Industrial Drive, Orlinda, TN fax

Model KBWF 720 Growth chambers with light and humidity

GRU-V Air Purifier. Product Manual

IWASAKI ELECTRIC CO., LTD

Dry Bath Heating Systems

Dräger Polytron 8000 Stationary gas detector (EC)

Gas detector tubes are most effective as a reference device for conducting spot checks, which gives an idea of present gas at that moment in time.

CLEAN AIR SYSTEM.

PHOTOSTABILITY CHAMBERS

Dräger Polytron 8310 IR Detection of flammable gases and vapour

VWR symphony CO 2 INCUBATORS

ES-20 Orbital Shaker-Incubator

Model gffoz Process Ozone Sensor (In-Line)

Ultraviolet Air Disinfection Equipment

CURE ZONE 2 (#A )

Open Liquid Calibration Baths

WASTEWATER Online UV%Transmission Analyzer

Steril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax:

CYBAS-i Cone High Performance Cone Crushers

Zareba System Overview

Dry Block Heaters. Dry Block Heaters. 2 Block Dry Block Heaters with Lid.

s ter k Hea y Bloc Dr

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR. Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand.

Professional Amalgam Non-regulated

Real-time Monitoring Technology for Preservation Environment of Archives

Sieger Apex. Flexibility that meets your requirements

Dry Block Heaters. Dry Block Heaters 2 Block Dry Block Heaters with Lid.

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Model KBWF 240 Growth chambers with light and humidity

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS

FastGene Plate Centrifuge. Instruction Manual. Catalog No. NG

PHOTOSTABILITY CHAMBERS

DOUTHITT HEAVY DUTY DIRECT METHOD SCREENMAKER

uv and ozone for commercial pools

HEPA/UV3 Sterilizing PCR Workstation and Cabinet

Photo Stability Chamber

UV-Ozone Technology and Applications

Air Showers The Safety Solution for Animal Research Laboratories. Viva Air Shower, Model - EAS-1B.

SHENZHEN LAMPLIC TECH CO., LTD UV LED SPOT CURING SYSTEM TECHNICAL MANUAL

Start Saving with VWR Laboratory Benchtop Equipment!

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

Uniclass L725111:D4 EPIC H32. CI/SfB 4 (53.9) X. thermostatic tap specification manual OPTITHERM

Dräger X-plore 8000 Powered Air-Purifying Respirator (PAPR)

The Hydrim C51wd Washer Disinfector. Perfectly prepares instruments for sterilisation in as little as 19 minutes.

Corporate Overview. April

INCREASE YOUR LAB EFFICIENCY

AMERICAN AIR & WATER, INC.

Dräger Polytron 8310 Stationary gas detector (DSIR)

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

Transcription:

UV cabinets DNA/RNA» UV cabinets DNA/RNA Range of advanced benchtop UV cabinets providing aseptic conditions for a variety of biomedical and biochemical procedures. The innovative built-in UV-air recirculator provides constant decontamination of the air volume within the cabinet, making it suitable for working with DNA/RNA, infectious and viral materials including prions. General purpose UV cabinets with UV cleaner/recirculator Double PCR workstation with UV cleaner/recirculator UVC/T-AR economy UV cabinet UVC/T-M-AR stainless steel UV cabinet UVT-S-AR double PCR workstation 5.1 Grant Instruments (Cambridge) Ltd

UV cabinets DNA/RNA» UVC/T-M-AR general purpose UV cabinet UVC/T-M-AR stainless steel UV cabinet Robust general purpose stainless steel UV cabinet designed to provide a convenient workspace. UV surface irradiation via dual 15 W 254 nm UV lamps High intensity UV air cleaner 25 m 3 /hour cleaner-recirculator continuous air flow with 1 cm UV irradiation distance UV protection UV-protective film on glass panels UV exposure control 24 hour digital timer Convenient, easy to use digital timer for accurate control of UV exposure Temperature control by microprocessor plus forced heated air circulation ensure a constant and even temperature within the chamber Automatic switch off of irradiated UV light when door opened Built-in patented UV cleanerrecirculator both increases the maximum density of UV light and generates 25 m 3 /h air flow exchange prevents unwanted contamination and protects the user from direct UV light during manipulation Front opening with three adjustable positions for ease of access

UV cabinets DNA/RNA» UVC/T-AR economy UV cabinet UV cabinet UVC/T-AR economy UV cabinet General purpose UV cabinet with a lighter, more basic and economical design than UVC/T-M-AR. UV surface irradiation single 15 W 254 nm UV lamp High intensity UV air cleaner 25 m 3 /hour cleaner-recirculator continuous air flow with 1 cm UV irradiation distance UV exposure control 24 hour digital timer Convenient, easy to use digital timer for accurate control of UV exposure White lamp provides local illumination of the workplace to optimise visual control during operations Built-in UV cleaner-recirculator prevents unwanted contamination and protects the user from direct UV light during manipulation Automatic switch of of irradiated UV light when door opened

UV cabinets DNA/RNA» UVT-S-AR double PCR workstation UVT-S-AR double PCR workstation stainless steel Large capacity stainless steel UV cabinet with additional space for equipment and accessories to allow for more comfortable and convenient working in PCR applications. Robust construction with large, 1.2 m x 0.52 m UV surface irradiation dual 30 W 254 nm UV lamp High intensity UV air cleaner 25 m 3 /hour cleaner-recirculator continuous air flow with 1 cm UV irradiation distance UV protection UV-protective film on glass panels UV exposure control 24 hour digital timer Convenient, easy to use digital timer for accurate control of UV exposure Front opening with three adjustable positions for ease of access Automatic switch off of irradiated UV light when door opened Built-in UV cleaner recirculator both increases the maximum density of UV light and generates 25 m 3 /h air flow exchange prevents unwanted contamination and protects the user from direct UV light during manipulation Ample additional space for equipment and comfortable working

UV cabinets DNA/RNA» Models and specifications UV cabinets models and specifications = standard General purpose General purpose economy PCR workstation UVC/T-M-AR UVC/T-AR UVT-S-AR Construction 34.7 kg h: 555 mm d: 515 mm w: 690 mm stainless steel frame and 27 kg h: 555 mm d: 515 mm w: 690 mm painted steel frame and 58 kg h: 585 mm d: 580 mm w: 1245 mm stainless steel frame and Panels glass with UV-protective film Plexiglass glass with UV-protective film Front opening with three adjustable positions UV lamp, 15 W, long life (up to 8000 hrs), ozone free 2 1 UV lamp, 30 W, bacteriocidal, ozone free 2 Bacteriocidal air recirculator, 25 m 3 /h air flow exhange UV recirculator, 30W (efficiency >99% per cycle) White lamp for workplace illumination 15 W 1 1 30 W 1 Digital timer 0 to 24 hours Power supply 220/240 volts (50/60 Hz)

Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK Office, using the details below. UK Office Keison Products, P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: +44 (0)330 088 0560 Fax: +44 (0)1245 808399 Email: sales@keison.co.uk Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.