Material and rotor description.

Similar documents
THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

PRODUCT CATALOGUE THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

Rotary heat exchangers Product catalogue

EU Air Handling Units with SEMCO EXCLU-SIEVE

Rotary heat exchangers

Submittal Data Performance Data Electrical Data

Enthalpy Wheel and its Application in Air Conditioning

Air is our element. energy recovery our passion. Rotors overview. Quick guide GOST VDI 6022

Economical, Flexible, Advanced Performance. Ventilation and Dehumidification for Healthy IAQ

SUSPENDED AIR HANDLING UNIT WITH ROTARY HEAT EXCHANGER

COOLING and DE-HUMIDIFICATION WITHOUT USING REFRIGERANTS

Principles of Active Desiccant Operation. Presented by Tom Peterson, CEO and Founder. Climate by Design International

INSTALLATION INSTRUCTIONS ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR

Heat Recovery Units. Heat Recovery 1

National Institutes of Health Building 37 Modernization Bethesda, Maryland MECHANICAL DEPTH EXISTING MECHANICAL SYSTEM

PowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois

Rotors overview. Quick guide GOST VDI 6022

39HQM Central Station Air Handling Units AiroVison Guide Specifications

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

Bill McCullough. Director ERV Products. Dallas, TX

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

AIR HANDLING UNITS ZHK 2000

INDUSTRIAL APPLICATIONS THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

GUIDE SPECIFICATIONS FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS

Trane CDQ Desiccant Dehumidification

Adsorption Chillers Energysmart Green Cooling

» WITH REGASORP ROTARY HEAT EXCHANGER

Why should you opt for ENTHALPY. Wheels for your. AHUs. ERVs. (Energy Recovery Ventilators) (Air Handling Units) from

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB

CHAPTER 4. HVAC DELIVERY SYSTEMS

Section 4 of 6 DOAS Core Technologies

Critical Process Food Grade Dehumidifier Series

Efficient energy recovery in AHU. DOHA, Qatar Timo Schreck Enventus AB, Sweden

Heat pump and energy recovery systems

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Refrigeration Systems and Accessories

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

Advanced rotor technology. from the market leader within desiccant dehumidification DESICC ANT WHEELS

Beijing Holtop Artificial Environment Technology Co., Ltd

Desiccants & Driers. By Norm Christopherson

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)

Energy Recovery Ventilation

DEHUMIDIFIERS & VENTILATORS

Portable honeycomb matrix compact dryer, with loading, combines dehumidifying plastic resin and conveying into a single unit.

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3A WGERV-C3A WGERV-A5A WGERV-C5A WGSERV-A5 WGSERV-C5

SOLAR AIR CONDITONING SYSTEM USING DESSICANTS

I-TEC ERV Economizer Ventilator System (Vent Code "E")

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

Desiccant Cooling Analysis Simulation software, energy, cost and environmental analysis of desiccant cooling system

Vapor thermocompressor. Stills

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

XeteX, Inc. All Rights Reserved.

VERSO Air Handling Units

Customers. The core of our innovation. Feeding&Conveying. Drying Dosing Temperature Control Refrigeration Granulation

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WFERV. Bard Manufacturing Company, Inc.

DES CHAMPS PRODUCTS 85% 4,400 CFM

about your house Choosing a Dehumidifier

TEVHR. Heat Recovery Ventilator

By MIKE WEST, PHD, PE Advantek Consulting Inc. Melbourne, Fla.

Indholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL

PGD930DES USER MANUAL. VER

Benefits Offered by Passive Dehumidification Wheel Speed Control

TECHNICAL SERVICE GUIDE

SECTION (15733) - DEDICATED OUTDOOR AIR UNITS

Application Data. Fig. 1 39M Unit with Energy Recovery Section

HOW TO SELECT AN INDIRECT THERMAL TECHNOLOGY FOR INDUSTRIAL MATERIALS PROCESSING

B. A. T. Basic Appliance Training

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

K.F. Fong *, C.K. Lee, T.T. Chow

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

SECTION (15733) - DEDICATED OUTDOOR AIR UNITS

Installation of Glass Lined Equipment

DANVENT CATALOGUE 1999

Temperature Distribution of Rotary Heat Recovery Units

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

Mink MV. Claw Vacuum Pumps for Rough Vacuum Industrial Applications. Claw Vacuum Technology by Busch

VERSO Air Handling Units

OURSE TITLE : MASS TRANSFER OPERATIONS 1 COURSE CODE : 5071 COURSE CATEGORY : A PERIODS/ WEEK : 4 PERIODS/ SEMESTER : 52 CREDIT : 4 TIME SCHEDULE

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST

Munters DesiCool removes excess heat in server room

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

AQUA LOW-MEDIUM SPEED BOTTLE WASHER

For an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure.

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Modeling of a regenerative indirect evaporative cooler for a desiccant cooling system

Energy recovery from exhaust gases using Heat Pipe technology

Liquid Ring Vacuum Pumps, Compressors and Systems

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Recent Advances in Energy, Environment and Economic Development

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4

Double Skin Casing Air Handling Units

THE IMPORTANCE OF THE DESICCANT RESULTS OF CROSS-CONTAMINATION TESTING ON DESICCANTS

Transcription:

Material and rotor description. Why we use aluminum series 8000? Due the very good manufacturing characteristics and resistance against corrosion AMARANT has chosen to use the 8000 series alloy both for rotary heat exchangers produced from plain material and coated material. Different types of surface treatment improve properties as corrosion resistance and absorption of the material. Strong and light, low weight is an advantage during assembly in many applications, and it is great conductor for heat. This makes aluminum the best choice for energyefficient systems. How it works? AMARANT rotary heat exchanger is built up of two layers of foil, where one is corrugated and the other totally flat. The air flows through the channel between the layers, warming up or cooling down the foil. While rotating the heat exchanger part of the heat exchanger are heated or cooled by the air. The channels change place and when entering the opposite side, heating process or cooling process will take place. Efficiency and pressure-drop. Efficiency depends on the rotor size plus well-height, and will increase by using smaller distance. AMARANT offer today 6 different well-heights: 1.3 / 1.5 / 1.7 /1.9/2.0 and 2.4mm Not to forget is that the pressure-drop is then also increasing when using smaller distance. Condensation can occur, and drain-pan is therefor recommended. AMARANT Quality To secure highest standard in quality, no gluing of the layers or welding in AMARANT rotor is used. This results in a repeatable high quality product. Airflow will be uniform through the channels and thereby conformable with the calculated air pressure drop, and superior geometry of the rotor.

Heat terminology. Sensible heat. When an object is heated, its temperature rises as heat is added. The increase in heat is called sensible heat. Similarly, when heat is removed from an object and its temperature falls, the heat removed is also called sensible heat. Heat that causes a change in temperature in an object is called sensible heat. Latent heat. All pure substances in nature are able to change their state. Solids can become liquids (ice to water) and liquids can become gases (water to vapor) but changes such as these require the addition or removal of heat. The heat that causes these changes is called latent heat. Latent heat however, does not affect the temperature of a substance - for example, water remains at 100 C while boiling. The heat added to keep the water boiling is latent heat. Heat that causes a change of state with no change in temperature is called latent heat. Appreciating this difference is fundamental to understanding why refrigerant is used in cooling systems. It also explains why the terms 'total capacity' (sensible & latent heat) and 'sensible capacity' are used to define a unit's cooling capacity. During the cooling cycling, condensation forms within the unit due to the removal of latent heat from the air. Sensible capacity is the capacity required to lower the temperature and latent capacity is the capacity to remove the moisture from the air. In simple words - Sensible heat/latent heat. Sensible heat is the heat due to temperature change and latent heat is the heat due to chase change in phase of the water content in the air

Materials. Pure aluminum rotor. (Mainly sensible heat recovery) Pure aluminum rotor from AMARANT is called condensation rotor, or thermal wheel, a cost-efficient solution for heat recovery, and is the most suitable choice for standard heat recovery applications. Mainly sensible heat recovery is taking place inside the rotor, but when condensation occur latent heat recovery is also taking place. Epoxy coated aluminum rotor. (Mainly sensible heat recovery) AMARANT epoxy coated aluminum rotor is also called condensation rotor or thermal wheel, also a cost-efficient solution for heat recovery. Most suitable choice for standard heat recovery applications where corrosion resistance is required. Epoxy coating protects aluminum from outside environment and is used mostly close to cost areas, swimming halls, heavy industry, ships and where high pollution can be expected. Mainly sensible heat recovery is taking place inside the rotor, but when condensation occur latent heat recovery is also taking place. Hygroscopic Rotor. (Sensible and latent heat recovery) AMARANT hygroscopic rotor, also called enthalpy rotor is also made of aluminum, but the hygroscopic surface of this foil, supports humidity transfer, either by adsorption or absorption. Typically used for standard applications in comfort ventilation systems to recover humidity, capable of recovering both heat and humidity. Absorption rotor. (Sensible and latent heat recovery) AMARANT absorption rotor is made from aluminum alloy, coated with molecular sieve material, also called desiccant wheel, adsorb moisture more then silica gel. Absorption rotors are especially designed for summer season, cooling recovery and dehumidification of supply air. This rotor keeps a high rate of humidity recovery from the exhaust air, but also very efficient dehumidification of supply air in hot and humid summer conditions. High dehumidification of supply air in this conditions, results in much lower needs of cooling load. Savings become both economically and mechanically. Cooling units can be smaller and this way more cost-efficient. High adsorption capacity at low relative humidity.

Housing. AMARANT housing is made of galvanized steel. Geometry of the housing depends on the size of the rotor. All rotors can be delivered in either galvanized or painted casings (corrosion protecting paint). All casings are sealed with brush-profiles Geometry according below table. Rotor diameter mm Standard casing (W x H), mm Depth mm Well-height 500-1085 Rotor diameter +100mm 270 1.3/1.5/1.7/1.9/2.0/2.4 1086-1550 Rotor diameter +100mm 320 1.3/1.5/1.7/1.9/2.0/2.4 1551-2700 Rotor diameter +150mm 320 1.3/1.5/1.7/1.9/2.0/2.4 IMPORTANT! Always transport the rotor in housing vertically Purge sector. To avoid cross contamination, (waist air to fresh air), a purge sector can be mounted on the cross beam of the rotor. Purpose of the purge sector is to clean the rotor channels before they enter fresh air area from waist air, this minimize the cross contamination in the rotor. Works only when the air streams are opposite to each other, and according below working conditions. Supply air Supply air Purge sector Exhaust air rotation Exhaust air

Description according AMARANT product key description Rotor in housing

Drive sets and Control units. Our drive systems and control units comes form well reputed companies as: IBC Automatic and Emotron / CG DRIVES & AUTOMATION Both constant speed drives, drive sets and control units are adapted to fit with requested rotor size and function. Drives are chosen depending on rotating speed and rotor size. All drives are secured as standard by a thermal contact and as option can be equipped with rotating sensor. The rotation sensor stops the control unit and alarms if the wheel stops rotating. Input signal 0 10 V The speed of the heat exchanger and its efficiency is regulated stepless by the control unit so that the speed of the wheel is in proportion to the input signal from the central control. If the input signal is below the set up threshold value, the wheel will stop. Cleaning function When the wheel has been stopped for 10 or 30 minutes, the cleaning function is activated and the wheel rotates, to keep it clean. Working conditions from -30ºC up to +40ºC Emotron / 45ºC IBC Automatic Constant speed - VP0500VKCEE VP3000VKCEE Made by IBC Automatic Drive sets and control units - VariMax series 25, 50 and 100 by IBC Automatic MicroMax series 25, 90, 180, 370 and 750 by IBC Automatic EMX-R series 15, 25 and 35 by Emotron IMPORTANT! All electrical work must be performed by qualified electrician.

Drive and control option rotor size Ø 500 Ø 3900 mm Unit Rotor size in mm IBC Varimax 25 Alu/Epoxy 500-1500, Hygro 500-1200 3 x 230 V, 110 W IBC VariMax 50 Alu/Epoxy 500 2500, Hygro 500 2000 3 x 230 V, 240 W IBC VariMax 100 Alu/Epoxy 500 3900, Hygro 500-3000 3 x 230 V, 500 W IBC MicroMax 25 Alu/Epoxy 500 800 IBC MicroMax 90 Alu/Epoxy 800 1500 IBC MicroMax 180 Alu/Epoxy 1500-2500 IBC MicroMax 370 Alu/Epoxy 2500 3500, IBC MicroMax 750 Alu/Epoxy 3500-3900 3 x 230 V, 25 W 3 x 230 V, 90 W 3 x 230 V, 180 W 3 x 230 V, 370 W 3 x 230 V, 750 W IBC Constant 25 Alu/Epoxy/Hygro 500 800 IBC Constant 90 Alu/Epoxy/Hygro 800 1500 IBC Constant 180 Alu/Epoxy/Hygro 1500-2500 IBC Constant 370 Alu/Epoxy/Hygro 2500-3000 3 x 230 V, 25 W 3 x 230 V, 90 W 3 x 230 V, 180 W 3 x 230 V, 370 W Emotron EMX 15 500-1500 Emotron EMX 25 1500-2500 Emotron EMX 35 2500-3500 40 W 100 W 160 W

Drive belts. AMARANT use two types of belts: Round belt Our round belt is hollow and made from polyurethane. This belt can quickly and easily be joined with metal connectors, so that there is no welding required. This belt provides excellent abrasion resistance, high elasticity, and is also self-tensioning. Belt tension should be ca: 5% *. Tension of the belt should be re-examine after the first 48 hour of action. 8, 10 and 12mm diameter belts are used. Power-belt Power-belt is made from composite polyester/polyurethane, proven to outlast and outperform rubber belts, especially on curves. Unaffected by extreme temperatures, water, steam, oil, grease, and common industrial chemicals and solvents, an operating temperature range, with no loss of performance, of -40º C to +66º C. Conventional SBR/chloroprene brand V belts simply can't compete. Tension of the belt should be re-examine after the first 48 hour of action. Belt tension should be 1-2%.* *All belts require adjustment, some once other a couple of times, depending on the environment they work in. Belt should be shorter then calculated length. When it comes to the power-belt, 1% is equal to 1 link per meter belt. Shaft Shaft can be supplied in various lengths. Standard size: from 220mm to 250mm. Other lengths on request. Bearing Standard bearing is ball-bearing. Other bearings on request.

When receiving the goods. AMARANT work only together with logistic companies that has a long experience of our products, but sometimes accident happens. Please check the pallets and rotors strict and critical for any external damages, before signing the documents. If you see a damage, don't forget to make a note about it on the CMR or packing list and ask the forwarder to sign it. All damages must be notified AMARANT immediately, either by e-mail or letter. Please check arrived goods correspond to your order. Hidden damages can be notified up to 7 days after receiving. Storage. The rotary heat exchanger either in casing or without, should be stored in a dry place, due to material and electric components. Rotors in casing, standing / or during maintenance in vertical position, should be secured so they can't fall. Rotor in casing can have a weight of up to 600 kg, an accident can cause serious health injury. Please store the rotors in a way so external damage impact is minimized. The rotor itself is quite fragile if hit by external impact. Lifting instructions. When lifting make sure no one is standing close to the rotor, hand, foot or body crashing injury can result in long term disablement. Hook and lift the exchanger in the bended gables that constitute front and back of the heat exchanger. Lift careful and make sure no electrical wires or belts are in clamp. Please see the pic. below.

For any questions regarding our heat exchanger or its components please contact us at: E-mail: info@amarantindustri.com or Andrzej.Krugly@amarantindustri.com You can also contact us by phone: +46 (0)705565723 or visit us at: AMARANT Industri AB Tommarpsvägen 46 23165 Trelleborg Sweden WWW.AMARANTINDUSTRI.COM