VIESMANN. Operating instructions DIGITAL TIME SWITCH. for the system user. Digital time switch for the Vitodens 100-W, type WB1B

Similar documents
VIESMANN. Operating instructions VITODENS 100-W. for the system user

VIESMANN. Operating instructions VITODENS 111-W. for the system user

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

VIESMANN. Installation and service instructions VITOTROL 300A. for contractors. Vitotrol 300A. Remote control, part no

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

VIESMANN. Installation and service instructions VITOTROL 200 RF. for contractors. Vitotrol 200 RF. Wireless remote control for one heating circuit

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

VIESMANN. Installation instructions. Extension AM1. Safety instructions. for contractors. Part no

VIESMANN. Installation instructions. Extension EA1. Safety instructions. for contractors. Part no

VIESMANN. Installation instructions VITOMAX 200-HW. for contractors

VIESMANN. Installation instructions VITOCROSSAL 200. for contractors. Vitocrossal 200 Type CM2 Gas fired condensing boiler with MatriX radiant burner

VIESMANN. Installation instructions VITODENS 200-W. for contractors

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors

VIESMANN. Installation instructions VITOCROSSAL 300. for contractors. Vitocrossal 300 Type CM3 Gas condensing boiler with MatriX radiant burner

VIESMANN. Datasheet VITOMAX 200-WS. Hot water boiler for permissible flow temperatures up to 110 C 1.75 to MW

VIESMANN. VITOMAX 200-LW Low pressure hot water boiler for permissible flow temperatures up to 120 C Rated heating output 8.0 to 20.0 MW.

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Operating instructions VITOTRONIC 200. for the system user

VIESMANN VITOROND 100. Datasheet Part numbers and prices: see pricelist VITOROND 100. Cast iron low temperature oil and gas fired boiler.

VIESMANN. VITOMAX 200-WS Rated heating output 1.75 to MW. Datasheet. VITOMAX 200-WS Type M250

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Operating instructions VITODENS VITOLADENS VITOPEND. for the system user

VIESMANN VITOLADENS 300-C Oil condensing boiler 12.9 to 28.9 kw

VIESMANN. Installation instructions. Mixer extension kit. for contractors. Mixer extension kit. For one heating circuit with mixer

VIESMANN. Installation and service instructions. Solar-Divicon SR. Safety instructions. Application. for contractors. Part no and

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Installation and service instructions VITOCELL 340-M/360-M. for contractors. Vitocell 340-M/360-M Type SVKA Type SVSA

Operating instructions

VIESMANN VITOLADENS 300-T Oil Unit condensing boiler 35.4 to 53.7 kw

VIESMANN VITOCROSSAL 300 Gas condensing boiler 787 to 1400 kw

VIESMANN. Installation and service instructions. EHE immersion heater. for contractors. EHE immersion heater

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17

VIESMANN VITOCROSSAL 300 Gas condensing boiler 187 to 635 kw

Solar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses.

Operating instructions

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

Operating Instructions. VITODENS r 200 Series With Vitotronic 200 HO1B Controls WARNING WARNING IMPORTANT

VIESMANN VITOVENT 300-F Mechanical ventilation system with heat recovery

VIESMANN VITOLADENS 300-C Oil condensing boilers 12.9 to 28.9 kw

Installation instructions PYROMAT ECO. for contractors PYROMAT ECO GB 8/2012 Dispose after installation.

Operating Instructions for use by heating contractor. VITOTRONIC r 100 VITOTRONIC r 300-K IMPORTANT

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

VIESMANN. Service instructions VITOCROSSAL 300. for contractors. Vitocrossal 300 Type CR3 and CR37, 787 and 978 kw Gas condensing boiler

INSTRUCTION FOR THE USER THC V E OIL BLU

Operating instructions

Operating instructions

VIESMANN. Service instructions. MatriX radiant burner. for contractors

Operating instructions

Operating Instructions

ir-range 8G /03.15 Changes reserved.

for contractors Vitoplex 200 Type SX2A For applicability, see the last page Please keep safe.

Operating instructions

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

Operating Instructions VITOCROSSAL 300 WARNING WARNING IMPORTANT. Read and save these instructions for future reference. for use by heating contractor

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

Operation Manual NOVA LIVE S

USERS MANUAL FOR GAS BOILERS

User manual. Logano GC 124 II. Gas boiler

End User Manual ACO 35 MFFI COMBI

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

USER'S INFORMATION MANUAL

Installation and user manual

TABLE OF CONTENTS. IMPORTANT Please read this manual carefully.

Operating Instructions and User s Information Manual VITOROND 200 WARNING WARNING IMPORTANT. Read and save these instructions for future reference.

VIESMANN. Operating and service instructions VITOMAX 200-HW. for contractors

Operating instructions Oil condensing boiler

VIESMANN. Service instructions VITODENS 200-W. for contractors

Users manual. Buderus /29/43/60 and Buderus T25/29T25 H/V. Wall-mounted condensing gas boiler. For the user

ecotec pro Operating instructions Operating instructions For the operator GB, IE Gas-fired wall-hung high-efficiency boiler

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit

Instruction manual. Aluminium radiator with ceramic heart. Smart Electric Heaters

Drayton Digistat +3RF

MURELLE EV HE 25/55-30/55

CEM-24 Series. Owner's Manual - Installation and Operating Instructions

MAKING MODERN LIVING POSSIBLE. FP975 7-Day Electronic Programmer. User Guide. Danfoss Heating

CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ

Operating Instructions VITOTRONIC 200 VITOTRONIC 300-K IMPORTANT. Read and save these instructions for future reference. for use by heating contractor

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

VIESMANN. Installation and service instructions VITODENS 100. for heating engineers

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

AVANT DGi. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

ST 53.1 User s manual

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

/2005 GB(EN) For the user. Wall-mounted condensing gas combi boiler Buderus /C, /C

User s Information Manual

ECL Comfort 210 / 296 / 310

Installation & User s Instructions

Clima Infrared Radiant & Convection Panel

GB24 & GB30. User Manual

Operation manual. Wall-mounted condensing boiler D2CND024A1AA D2CND024A4AA D2TND012A4AA D2TND018A4AA D2TND024A4AA

multimatic Operating instructions AT, BE (de), CH (de), DE VRC 700f/4

Electronic timeswitch

Panel Convector Heater User Instructions

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

Transcription:

Operating instructions for the system user VIESMANN Digital time switch for the Vitodens 100-W, type WB1B DIGITAL TIME SWITCH 5/2008 Please keep safe.

Safety instructions For your safety Please follow these safety instructions closely to prevent accidents and material losses. Safety instructions explained! Danger This symbol warns against the risk of injury. Please note This symbol warns against the risk of material losses and environmental pollution. Details identified by the word "" contain additional information. Target group These operating instructions are for the heating system user. This unit is not designed to be used by persons (including children) with limited bodily, sensory or mental capacities, or lacking experience and/ or lacking knowledge, unless they are supervised by a person responsible for their safety, or have received instructions from such a person as to howtousetheunit.! Please note Childrenshouldbesupervised. Ensure that children do not play with the unit. Danger Incorrectly executed work on the heating system can lead to life-threatening accidents. & Work on gas appliances must only be carried out by a registered gas fitter. & Work on electrical equipment must only be carried out by a qualified electrician. If you smell gas Danger Escaping gas can lead to explosions which may result in serious injury. & Do not smoke. Prevent naked flames and sparks. Neverswitchlightsorelectrical appliances ON or OFF. & Close the gas shut-off valve. & Open windows and doors. & Remove all people from the danger zone. & Notify your gas or electricity supplier and your heating contractor from outside the building. & Shut off the electricity supply to the building from a safe place (outside the building). 2

Safety instructions For your safety (cont.) If you smell flue gas Danger Flue gas can lead to life-threatening poisoning. & Shut down the heating system. & Ventilate the boiler room. & Close all doors in the living space. In case of fire Danger Fire creates the risk of burning and explosions. & Shut down the heating system. & Close the shut-off valves of the fuel lines. & Use a tested fire extinguisher, class ABC. Boiler room requirements! Please note Incorrect ambient conditions canleadtodamagetothe heating system and put the safe operation at risk. & Ensure ambient temperatures above 0 ºC and below 35 ºC. & Prevent air contamination by halogenated hydrocarbons (e.g. as contained in paints, solvents or cleaning fluids) and excessive dust (e.g. through grinding/polishing work). & Avoid continuously high humidity levels (e.g. through frequent drying of washing). & Never close existing ventilation apertures. Ancillary components, spare and wearing parts! Please note Components that are not tested with the heating system mayleadtodamagetothe heating system, or may affect their various functions. Installation or replacement work must only be carried out by qualified personnel. 3

Wheretofindthecontrols Summary of controls and indicators On the time switch, different start and stop times can be set for DHW and central heating. Central heating r is controlled via time switch channel 1 (CH1) and DHW heating w via time switch channel 2 (CH2). The display shows the current time and day of the week. The display alternately shows the switching states (ON/OFF) of both channels and the set switching times. F Time format display G Summertime display H Time K Display, switching times for the day. The display alternates regularly between central heating (CH1) and DHW heating (CH2) L Time switch channel display (programming mode: Number of a switching point) M DHW heating display: ON A User interface B Manual mode Automatic mode C Central heating display: ON OFF D Programmingmodedisplay E Day (programming mode: Validity of a switching point) OFF Controls + Set key and changeover to central heating r in manual or automatic mode Set key and changeover to DHW heating w in manual or automatic mode Menu Input/display switching times (individual time programs) OK Confirmation Res. Change the default time programs (initial installation) +1h Summertime/winter time changeover 4

Settings Commissioning (setting the time and switching program) The current day of the week, time and required switching program are set during the initial installation. There are 3 switching programs preset. You can accept one of the programs or alter it to suit your requirements. You can also create an individual program. Select the switching program that most closely matches your requirements. Individual switching points can still be changed, added and deleted later via the menu. A switching program can contain up to 10 start times and 10 stop times. Theswitchingpointscaneachbe valid for a single day, every day or a group of days (weekdays, weekend): & Single day & Monday to Friday & Monday to Saturday & Saturday and Sunday Overview of the preset programs The switching times apply to every day of the week. Central heating and DHW heating take place in the specified periods. P01 Daily from 06:00 to 22:00 h P02 Daily from 07:00 to 12:00 h and from 14:00 to 20:00 h P03 Daily from 07:00 to 12:00 h, 14:00to18:00hand20:00to 22:00 h Accepting a preset program Press the following keys 1. Res. Date format "24h" flashes. 2. +/ Select date format "24h" or "AM/PM" 3. OK "00" (hour) flashes 4. +/ Set the current hour Winter time is entered here. You can change over to summertime later by pressing "+1h" in the main menu. 5. OK "00" (minute) flashes 5

Settings Commissioning (setting the time and switching... (cont.) 6. +/ Set the current minute 7. OK The setting for the current day appears 8. +/ Select the current day (1= Monday, 7 = Sunday) 10. +/ Select preset program "01", "02" or "03" 11. OK Confirm entry 12. Menu Finish setting 9. OK "P 01" (program 1) appears. "01" flashes Adapting a preset program Press the following keys 1. Res. Date format "24h" flashes. 2. +/ Select date format "24h" or "AM/PM" 10. +/ Select preset program "01", "02" or "03" 11. OK "prog" appears. "01" (first start time of program set in step 10) flashes. 3. OK "00" (hour) flashes 4. +/ Set the current hour Winter time is entered here. You can change over to summertime later by pressing "+1h" in the main menu. 5. OK "00" (minute) flashes 6. +/ Set the current minute 7. OK The setting for the current day appears Example: Central heating starts daily at 06:00 h. The program number is no longer displayed. 8. +/ Select the current day (1= Monday, 7 = Sunday) 9. OK "P 01" (program 1) appears. "01" flashes 6

Settings Commissioning (setting the time and switching... (cont.) 12. +/ Select the start time to be changed A start time (odd number and circle symbol filled in) is always followed by a stop time (even number and circle symbol blank). For the preset programs, the central heating switching points r (CH1) are followed by the DHW heating switching points w (CH2). To add a new switching point, select the highest number (" : " is displayed). 13. OK The time (hour) of the start time flashes 14. +/ Change the hour If you want to delete the start time and corresponding stop time, select " " and proceed from step 27. 15. OK Minute flashes 16. +/ Change the minute of the start time 17. OK The setting for the days of the week appears 18. +/ Select the day or group of days (1= Monday, 7 = Sunday) 19. OK The time switch channel flashes ("CH1" for central heating; "CH2" for DHW heating) 20. +/ Change the time switch channel 21. OK The display changes to the stop time (circle symbol blank). The time (hour) of the stop time flashes 22. +/ Change the hour 23. OK Minute flashes 24. +/ Change the minute of the stop time 25. OK The setting for the days of the week appears 26. +/ Accept the start time setting (switching OFF on the same day) or postpone by a day (switching OFF the following day). 27. OK The next start time flashes. To change further switching points, proceed from step 12. 28. Menu Finish setting 7

Settings Commissioning (setting the time and switching... (cont.) Entering an individual program Theprocedureisthesameasfor "Adapting a preset program". In step 10, select the program " " and enter the required switching times. Setting the summertime/winter time Press "+1h". The display shows "+1h". The hour changes to summertime. Setting the time and day Time and day are usually set during commissioning. You can correct the settings as follows: Press the following keys 1. Menu Date format "24h" flashes. 2. +/ Select date format "24h" or "AM/PM" 3. OK Hour flashes 4. +/ Set the current hour 5. OK Minute flashes 6. +/ Set the current minute 7. OK The setting for the current day appears 8. +/ Select the current day (1= Monday, 7 = Sunday) 9. OK Confirm entry 10. Menu Finish setting Changing, adding and deleting switching times You can change the set time program to suit your requirements. You can add, change or delete switching points. 8

Settings Changing, adding and deleting switching times (cont.) Press the following keys 1. Menu Date format "24h" flashes. 2. OK "00" (hour) flashes 3. OK "00" (minute) flashes 4. OK The setting for the current day appears 5. OK "prog" appears. "01" (first start time) flashes. 8. +/ Change the hour If you want to delete the start time and corresponding stop time, select " " and proceed from step 21. 9. OK Minute flashes 10. +/ Change the minute of the start time 11. OK The setting for the days of the week appears Example: Central heating starts daily at 06:00 h. 6. +/ Select the start time to be changed A start time (odd number and circle symbol filled in) is always followed by a stop time (even number and circle symbol blank). To add a new switching point, select the highest number (" : " is displayed). 7. OK The time (hour) of the start time flashes 12. +/ Select the day or group of days (1= Monday, 7 = Sunday) 13. OK The time switch channel flashes ("CH1" for central heating; "CH2" for DHW heating) 14. +/ Change the time switch channel 15. OK The display changes to the stop time (circle symbol empty). The time (hour) of the stop time flashes 16. +/ Change the hour 17. OK Minute flashes 18. +/ Change the minute of the stop time 19. OK The setting for the days of the week appears 9

Settings Changing, adding and deleting switching times (cont.) 20. +/ Accept the start time setting (switching OFF on the same day) or postpone by a day (switching OFF the following day). 21. OK The next start time flashes. To change further switching points, proceed from step 6. 22. Menu Finish setting Manual start-up/shutdown You can intervene in the active switching program. Central heating OFF, DHW heating ON Central heating ON, DHW heating OFF Central heating r can be changed over with "+". DHW heating w can be changed over with " ". The time switch returns to automatic mode next time the key is pressed or at the next switching point. 10

11

Printed on environmentally friendly, chlorine-free bleached paper Your contact Contact your local contractor if you have any questions regarding the maintenance and repair of your system. You may, for example, find local contractors on the internet under www.viessmann.com. 12 Viessmann Werke GmbH&Co KG D-35107 Allendorf Telephone: +49 6452 70-0 Fax: +49 6452 70-2780 www.viessmann.com Viessmann Limited Hortonwood 30, Telford Shropshire, TF1 7YP, GB Telephone: +44 1952 675000 Fax: +44 1952 675040 E-mail: info-uk@viessmann.com Subject to technical modifications.