CONSULTANT PROCEDURES & DESIGN GUIDELINES ACCESS CONTROL SYSTEM

Similar documents
B. After installation, the Owner shall be able to perform hardware configuration changes as desired without the services of the Integrator.

Card Access Control Specifications

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 28 ELECTRONIC SAFETY AND SECURITY

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE

APPENDIX F: LOCKSETS AND ACCESS CONTROL

Appendix 1 LACCD Districtwide Security Performance Requirements

CARD ACCESS CONTROL SYSTEM

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

END of revision. Update Commentary: Section was updated primarily for the following reasons:

SECTION SECURITY AND ACCESS CONTROL

USD 380 Centralia, Frankfort & Vermillion

UNC100 Integra Manual

SECTION INTRUSION DETECTION

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY

ELECTRONIC SAFETY AND SECURITY SYSTEMS

106. LOCK AND CARD ACCESS GENERAL DESIGN INFORMATION

DOOR HARDWARE SECTION DESIGN REQUIREMENTS GENERAL INFORMATION

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Access Control System - CAAMS. Basis of Design

UBC Technical Guidelines Section Edition Door Hardware Page 1 of 7

Missouri S&T Electronic Access Control Naming Convention

Wayne State University Police Department. Alarm/Card Access Specification s & Standards

16722 ELECTRONIC SAFETY AND SECURITY SYSTEMS

DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY

RFP Addendum 2 March 31, 2016

UBC Technical Guidelines Section Edition Access Control Page 1 of 5

Architect s Specification Guideline:

LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

Addendum 002. Acknowledge receipt of this Addendum in the space provided in the Bid Form. Failure to do so may disqualify the Bidder.

SECTION DOOR HARDWARE

ACCESS CONTROL ENTERPRISE SYSTEM (ACES) CARD ACCESS DIVISION , ISSUE # 6, JANUARY,

DIGI*TRAC Annunciator Guide DTA

The purpose of this addendum is to further clarify the requirements of the plans and specifications.

Electronic Safety and Security

SECTION DOOR HARDWARE

A Beginners Guide to Inner Range Systems

PIV-Enabled. Access Control Solutions for Government Facilities

ONYX FirstVision Specification Interactive Firefighters Display

VertX Access Controllers

Security Considerations for Secure Workplaces

APPENDIX E ACCESS CONTROLS SYSTEM DESIGN GUIDELINES (TAMPA CAMPUS)

UNIVERSITY OF ROCHESTER DESIGN STANDARDS FEBRUARY 2005MARCH 2007

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide

ONONDAGA COMMUNITY COLLEGE FERRANTE HALL RENOVATIONS - PHASE

GARCIA GALUSKA DESOUSA Consulting Engineers

1.1 Ensure the room is in the ACCESS state. Workstation indicates zone is in ACCESS state.

System components portfolio overview. Power supplies, electromagnetic locks, electric strikes and system accessories

Architect s Project Number of 12 Fire Alarm/Smoke Detection Systems District Master Specs 2013 Edition

HRX Technical Manual. Version 1.2

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

SECTION DOOR HARDWARE

Design & Construction Standards, Revised September

Aperio Technology. Wireless possibilities for online access control

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

For Dealers / Integrators / Architects. IS Series. Video Intercom. Building Communication. Controlling Security.

COMBINED CONTRACT Nov. 10, NOTICE TO BIDDERS: Amend the Project Manual and Drawings to the above referenced project as follows: PROJECT MANUAL

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION LOW VOLTAGE LIGHTING CONTROLS

SECTION SECURITY TESTING AND COMMISSIONING

System Design and Overview Document

ARCHITECTURAL AND ENGINEERING SPECIFICATION

Grandstream Networks, Inc. GDS3710 Input/output Connection Guide

Retrofit Solutions Upgrading access control from doors to drawers

Nash Rocky Mount Schools. Specifications for; Upgrades and Additions to Existing Door Access Control System Phase 3

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

OJD ITB No Attachment E Duress Alarm Equipment Specifications

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

DE5300 Delayed Egress System. General Information

University of Texas Project Schedule Narrative February 17, 2009 Page 1

Avigilon Control Center System Integration Guide

DESIGN GUIDELINES AND TECHNICAL STANDARDS

InBio X60 Series Access Control Panel User Manual

The system should also be capable of recording events automatically on any compatible DVR and should be able to retrieve recordings based on events.

DIGI*TRAC Annunciator Guide

Networked Access Control Panel. Installation Guide

Electronic Solutions for Education

Installation, Operating and Maintenance Manual

Why Should You Invest In An Access Management System?

SECTION NURSE CALL SYSTEM

Upgrade Your Solution: Mechanical to Electrical

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

BSD Technical Standard. Division 28: Electronic Safety & Security

DIRECTORATE OF ESTATES

E-PLEX 5x70 Series Stand-Alone Access Controller. Installation Instructions

Wireless Access Control Light Commercial Lockset. WIACCOCAT - Wireless Access Control Light Commercial Lockset Catalogue_

Standards and Procedures. Installation of Cameras and Camera Systems At University of North Carolina at Wilmington UNCW

LaserFOCUS VLF-250 Engineering Specification

HARDwired Installation/ Owner s Manual

EPlex 5000 Series MONACO LOCK COMPANY, INC. TEL (800) FAX (800)

Monarch Electrified Series

Your partner for security solutions

Grandstream Networks, Inc. GDS3710 Input/output Alarms Configuration Guide

PART 1 GENERAL Quality Assurance A. Fire Alarm Contractor Qualifications:

DIAMOND II. DARM Delayed Alarm Reporting/Masking. Manual Number AV Revision - A.1 September 3, 2004

Mechanical to Electrical Making the Jump

Advisor Advanced Mobile Application User Manual

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

Transcription:

GENERAL: To provide minimum standards for Access Control Systems. PART 1 Common Work Results for Access Control System 1.1 Owner will provide server and software for connecting control panels through the use of the owner provided TCP/IP network. 1.2 Owner shall provide necessary means for Access Control System Integrator to configure all controllers using Owner s server and existing control software installation. The Access Control System Integrator shall configure all controllers and doors in the Owner provided software. 1.3 The system shall be capable of utilizing the existing LAN / WAN connecting the buildings or a dedicated security Ethernet network for controller and client communications. 1.4 After installation, the Owner shall be able to perform hardware configuration changes as desired without the services of the Integrator. 1.5 Control panel usernames and passwords shall not remain the default username and password. Upon Contractor s request, Owner will provide Contractor usernames and passwords for all hardware requiring passwords. 1.6 Owner shall utilize existing campus ID cards. Integrator shall not provide cards for use with the system. 1.7 Integrator must provide Authorized Dealer Certificate and Certified Training Certificates of Integrators who will be working on this project. 1.8 Integrator shall provide shop drawings to include: 1.8.1. Drawings showing layout of equipment 1.8.2. Field controller equipment location wall layouts, including size requirements 1.8.3. Detailed wiring diagrams of field controllers, door details, and head-end devices 1.8.4. Load calculations of all security equipment for proper sizing of electrical and standby emergency generator circuits 1.9 Integrator shall provide as-built drawings prior to final acceptance by Owner. 1.10 Integrator shall be a Company specializing in intrusion detection and access control systems with a minimum of three years experience on systems of similar size and scope. Technicians performing installation, configuration, and final terminations on the access control system shall have been certified by the manufacturer of the controller and software used for this project in accordance with the manufacturer s requirements. 1.11 All equipment, materials, and labor shall be warrantied for a period of 12 months from the date of final acceptance by the Owner. During the warranty period, the Contractor shall repair any fault in the system or hardware failure within 72 hours of the Owner reporting an issue to the contractor. Revised 7/1/16 Page 1 of 7 281300

1.12 Doors shall be controlled by control panels located on the same floor as the door itself. Controlling doors from control panels located on floors above or below the connected door is not permitted unless approved by the Project Manager. 1.13 All doors shall be equipped with a card reader, request to exit device (REX), and a door position switch. 1.14 Control wiring shall be installed in conduit until above ceiling level; above ceiling level, cable may be installed in cable tray or J-hooks. Contractor shall label all cables. 1.15 Controls panels shall be located in a lockable room, typically the telecommunications closet. 1.16 All control panels and door hardware power supplies shall be connected to emergency power. 1.17 A backup battery shall be provided for all control panels, and runtime on batteries shall be a minimum of 30 minutes. 1.18 All doors shall fail secure. 1.19 Install wiring for detection and signal circuit conductors in conduit. Use 22 AWG minimum size conductors. 1.20 All Hardware, Channels and Access Levels shall be named in access control software upon creation in accordance Owner s convention. Integrator shall follow naming conventions documented in Missouri S&T Electronic Access Control Naming Convention. This document can be found on the Missouri S&T Design & Construction Management s Contractor webpage at http://designconstruction.mst.edu/contractors/. 1.21 Where electric panic is specified, do not allow mechanical latching (unlocking) of panic device to override the access control system (do not include method for dogging down of panic hardware). 1.22 Electric strikes must accept pre-load. 1.23 As part of the ordering process of the custom HID Multiclass SE readers, all vendors order must be pre-authorized by the Owner before HID will allow a purchase. Upon award of contract, the Integrator shall submit the following information to the Owner for ordering authorization: 1.23.1. Vendor/Company Name 1.23.2. HID Customer ID (if available) 1.23.3. Company Address 1.23.4. Contact info for vendor/company point of contact PART 2 Acceptable Door Hardware Configurations 2.1 Single doors not requiring panic hardware 2.1.1. Electric strike, door position switch, motion detector, smart card reader 2.2 Single doors requiring panic hardware 2.2.1. Electric panic hardware with RQE integrated into panic, door position switch, smart card reader 2.3 Double doors Revised 7/1/16 Page 2 of 7 281300

2.3.1. Electric panic hardware with RQE integrated into panic (each door), door position switch (each door), smart card reader (operates one door). Card reader shall operate one of the two doors. Other doors to be monitored and unlocked/locked through input/outputs. 2.4 Exterior entrance locations having a bank of doors: 2.4.1. Electric panic hardware with RQE integrated into panic (each door), door position switch (each door), smart card reader (operates one door of the bank of doors). Other doors in bank to be monitored and unlocked/locked through input/outputs. PART 3 Operation 3.1 Doors requiring automatic door operators 3.1.1. Locked mode 3.1.1.1. Pressing secure side automatic door opener actuator opens door. 3.1.1.2. Pressing unsecure side automatic door opener actuator without presenting valid card performs no action. 3.1.1.3. Presenting valid card unlocks door. Pressing unsecure side automatic door opener actuator within unlock timeframe activates automatic door opener. 3.1.2. Unlocked mode PART 4 Products 4.1 Control Software 3.1.2.1. Pressing automatic door opener actuator on either side activates automatic door operator 4.1.1. RS2: Software and licenses provided by owner. RS2 system shall be specified unless otherwise noted. 4.1.2. Hirsch Velocity: Software and licenses provided by owner. Hirsch Velocity system shall only be specified upon specific instruction by Owner. 4.1.3. CBORD Access: for use with Residential Life facilities only. 4.2 Controllers 4.2.1. Mercury Security Hardware 4.2.1.1. EP1502 4.2.1.2. EP1501: Permitted only upon Owner s approval 4.2.1.3. MR-52 4.2.1.4. MR-16 4.2.1.5. MR-51e: Permitted only upon Owner s approval 4.2.2. CBORD Squadron Hardware: for use with Residential Life facilities only 4.2.3. No Substitutions Revised 7/1/16 Page 3 of 7 281300

4.3 Smart Card Readers 4.3.1. Custom HID Multiclass SE (for use with RS2 system only) 4.3.1.1. R10 Form Factor Manufacturer s Part Number: 900NWNNEKE00KG 4.3.1.2. R15 Form Factor Manufacturer s Part Number: 910NWNNEKE00KG 4.3.1.3. R40 Form Factor Manufacturer s Part Number: 920NWNNEKE00KG 4.3.1.4. RK40 Form Factor Manufacturer s Part Number: 921NWNNEKE00NN 4.3.2. Custom HID Multiclass SE (for use with Hirsch Velocity system only): 4.3.2.1. R10 Form Factor Manufacturer s Part Number: 900NWNNEKE0535 4.3.2.2. R15 Form Factor Manufacturer s Part Number: 910NWNNEKE0535 4.3.2.3. R40 Form Factor Manufacturer s Part Number: 920NWNNEKE0535 4.3.2.4. RK40 Form Factor Manufacturer s Part Number: 921NWNNEKE0535 4.3.3. Custom HID Multiclass SE (for use with CBORD system only); applies only to Residential Life facilities: 4.3.3.1. R10 Form Factor Manufacturer s Part Number: 900NWNNEKE00GK 4.3.3.2. R15 Form Factor Manufacturer s Part Number: 910NWNNEKE00GK 4.3.3.3. R40 Form Factor Manufacturer s Part Number: 920NWNNEKE00GK 4.4 Magnetic Stripe Readers 4.4.1. Not permitted 4.5 Door Position Switches 4.5.1. Schlage flush mount magnetic switches 4.5.2. Substitutions permitted upon Owner approval. 4.6 Electric Strikes 4.6.1. Von Duprin 4.6.2. HES 4.6.3. Substitutions permitted upon Owner approval. 4.7 Electrified Panic 4.7.1. Von Duprin QEL/RX 99-L 4.7.2. Sargent 80 Series 4.7.3. No Substitutions 4.8 Motion Detectors Revised 7/1/16 Page 4 of 7 281300

4.8.1. Bosch 4.8.2. Securitron 4.8.3. Substitutions permitted upon Owner approval. 4.9 Power Transfer Hinges 4.9.1. Von Duprin EPT-10 4.9.2. Von Duprin EPT-2 4.9.3. Securitron CEPT 4.9.4. No Substitutions 4.10 Power Supplies 4.10.1. Altronics 4.10.2. Von Duprin 4.10.3. Allegion 4.10.4. Securitron PART 5 Commissioning 5.1 Pre-Function Tests 5.1.1. Complete Electronic Access System Hardware Form to Owner to obtain IP addresses for system hardware. Form shall be submitted to the owner 3 business days prior to the Contractor s need for system IP addresses. This document can be found on the Missouri S&T Design & Construction Management s Contractor webpage at http://designconstruction.mst.edu/contractors/. 5.1.2. Contractor shall obtain login information to server and locks control software for programming and testing. Request login information from Owner s Access Control Specialist. 5.1.3. Test and document security device connections with a multi-meter to verify proper termination and operation. 5.2 Operational Field Test 5.2.1. System Channel, Hardware, and Access Level naming shall be completed prior to Operational Field Testing with Owner. Owner must approve naming 72 hours prior to start of operational field testing. 5.2.2. Electronic as-built drawings shall be provided to the Owner 72 hours prior to the start of the Operational Field Test. 5.2.3. Complete Contractor section of Electronic Access Door Commissioning Form for each door connected to the electronic access system, and submit one copy to Owner 72 hours prior to Operational Field Test. This document can be found on the Missouri S&T Design & Construction Management s Contractor webpage at http://designconstruction.mst.edu/contractors/. Revised 7/1/16 Page 5 of 7 281300

5.2.4. Operational Field Testing can be scheduled once the communications cabling contractor has completed the portion of the voice and data network which supports the electronic access system. 5.2.5. Conduct a system test of each alarm point and door. Owner shall document results on Electronic Access Door Commissioning Form. While conducting this test, the Contractor shall be in direct communication with Owner s Access Control Specialist as he/she observe the signals in the software. The following functions shall be tested for every door in the system: 5.2.5.1. In card-only mode: a. Access granted with card b. Access denied with card c. Door forced open (simulate by using physical key) d. Exiting from secure side (no alarms should be present) e. Door held open f. Power fail test g. For doors with automatic opener: 1) Access granted with card, then automatic operator button pressed from unsecure side: door should unlock then automatic operator open door 2) With no card presented, automatic operator button pressed on unsecure side: no operation should be observed 3) Operator button pressed on secure side: automatic opener should operate 5.2.5.2. In unlocked mode: a. Open door from secure side: observe door opened in system, then door closed b. For doors with automatic opener: 1) Operator button pressed on unsecure side: automatic opener should operate 2) Operator button pressed on secure side: automatic opener should operate 5.2.6. If any function fails in the Operational Field Test, failures must be noted and a full test (only on doors that failed Operational Field Test) must be performed at a later date to ensure compliance. 5.2.7. The Owner s Access Control Specialist must be present for all Operational Field Tests and re-tests. 5.3 Integrated Systems Test 5.3.1. Test critical system interfaces such as fire alarm and elevators. 5.4 Substantial Completion Requirements Revised 7/1/16 Page 6 of 7 281300

5.4.1. All devices and alarm points must pass operational field test Revised 7/1/16 Page 7 of 7 281300